Air Compressor Conversion! Out With Old, In With the New!! 120v to 240v motor and new pump!

Тәжірибелік нұсқаулар және стиль

Gutting out an air compressor that is extremely weak, loud and inefficient for a better motor and pump. Utilizing Harbor Freight for the new pump and motor. And fabricating from scratch all the custom work necessary to make this happen.

Пікірлер: 100

  • @lrod1966
    @lrod19666 ай бұрын

    That fitting is JIC 14. Take it to anyone that makes hydraulic hoses and get a rubber hose to go from the compressor to the tank. Put a check valve in the tank inlet. Also to make slots you can put an end mill in your drill press, use a fence as a guide and push the plate, slowly with light pressure. Make sure to only drill a start hole, no end hole. You can put an amp meter on 1 leg of the power to see how fast you can spin the compressor without going over the rated amps on the motor.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    Nice! A great amount of information. Thank you.

  • @TF856
    @TF85617 күн бұрын

    You don't have to mount those items on to the tank if you don't want to. My dad's first big air compressor was in two separate units. The motor and pump were on one platform and only connected to the tank with a hose sitting side-by-side.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    4 күн бұрын

    Thank you for the comment

  • @richardportelli1983
    @richardportelli198310 ай бұрын

    Belt should be at the back of the tank away from your fittings etc.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    10 ай бұрын

    Thanks for the comment Richard!

  • @TF856
    @TF85617 күн бұрын

    The pulies should be on the back not on the front. I would also highly recommend moving the whole manifold setup farther away from the moving parts bringing them outward using pipe elbows. And you must be missing a check valve going into the tank. That's why it is leaking backwards through the pump and coming out of that vent. You may also want to add an unloader to that system. It will make it easier for the pump to start up in cold weather.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    4 күн бұрын

    Thank you for the comment

  • @user-nv2co2pe3y
    @user-nv2co2pe3y3 ай бұрын

    Good job! I enjoyed your work. Thank you for sharing!

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    3 ай бұрын

    Thank you for the comment!

  • @mpowersmedia3219
    @mpowersmedia3219Ай бұрын

    Sure you have already figured this out but just for future reference. There are different types of threading used. NPT and what I call straight threads cause I can't remember the abbreviation but if you have compression style it won't be NPT cause NPT are tapered, just research it and it will be explained and will save you much frustration in the future, this was my dilemma also and how I learned it. Also you can make any size V belt you need by splicing it together and it works great for your application. I spliced a belt for my drill press 5 years ago and it's still going strong. I watched a you tube video to figure out the best method . Great video btw

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    Ай бұрын

    Thanks for the comment.

  • @Fordcertian
    @Fordcertian6 ай бұрын

    Dude, I'm a pipefitter, shipfitter, grade a #1 struckuall Steele fitter, there's a difference between NPT and tubing, pipe inside measurements tubing outside measurements! You just need a coupling to join them. Those people at the store ain't stupid but they can't tell you what they don't know! God Bless you and yours!

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    Its fine. thnx for the comment

  • @gergemall

    @gergemall

    3 ай бұрын

    God bless you. Beautiful music. Love the video

  • @jamesbrady2156
    @jamesbrady21566 ай бұрын

    I am looking at this video and seeing that my next compressor will be purchased as a complete unit rather than modified using my old tank. Thanks for the lesson.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    Do not let watching me fumble around with this project discourage you. Anybody with more skill and practice than me might make this look easier. I try to portray what it looks like for the average person. Each individual situation is going to be different. It is going to depend on the amount of motivation of the person, amount of time to finish the project, compatibility of the new equipment and condition of the old equipment. Plus the cost. Can not remember how much I discussed it, but the cost of new 220v, belt driven, oil cooled compressors has skyrocketed. So off to the project i went.

  • @wmjohnson7063
    @wmjohnson7063Ай бұрын

    I would switch pump and motor and you’d have more clearance for everything. Oh well life goes on.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    Ай бұрын

    Thanks for the comment

  • @williamsmith3872
    @williamsmith3872Ай бұрын

    It sure looks like the big pulley is either mounted backwards on the pump or the pump is supposed to run in the other direction. I surmised that fact due to the fan blades should be blowing toward the pump motor.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    Ай бұрын

    Your a little bit late to the party. Hope you catch up watching the next 2 videos in this series. Thanks for the comment.

  • @williamsmith3872

    @williamsmith3872

    Ай бұрын

    I want to compliment you on the great work your doing. Thanks for sharing👍

  • @Myrddraalfade
    @MyrddraalfadeАй бұрын

    I did a similar conversion myself, I found out half way through that altering the handle and mounting the pump/motor assembly facing the handle was a lot safer than having moving belts above the power switch and air outlet. Cut the handle and used some heavy conduit L's and pipe to bring it out about 6"-7" for safety, with a cage.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    Ай бұрын

    Thanks for the comment. I have a part 2 and 3 follow up if you would like to watch. Thanks.

  • @dontblameme6328
    @dontblameme6328Ай бұрын

    Your paw paw's old homemade compressor is made from an antique refrigerator. Common thing to do back in the day. I have one that was my dad's.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    Ай бұрын

    Thank you for the comment.

  • @cordelleustache9031
    @cordelleustache9031 Жыл бұрын

    You have to change the direction that the motor spins .The pulley on the pump works as a fan so it should spin in the opposite direction.And you need to put a check valve on the tank input.That's why air is leaking from the pump.

  • @PaulThomas-qo9vy

    @PaulThomas-qo9vy

    Жыл бұрын

    Yes Flywheel/Fan rotation MUST be Counter-clockwise (viewing flywhl/Fan from Flywhl. side). The fan blades always need to blow cooling air into & across the pump cooling fins! (Look for small Arrow cast into a fin & mark with white paint for easy reference.) 2nd)Splash-lube systems must "bounce" the splashed oil off of engineered internal angles to direct the oil to the necessary lube & cooling points. Running it bass-ackwards will starve something for oil & cause premature failure. 3rd) Finally, Running a pump bass-ackward will cause low pressure or volume performance. I have an HF 3hp pump like yours & and have great service from it. Now, I want to finish my 5hp HF V-twin 30 gal. gas powered portable comp. For the best hobby sized near-passive aftercooler moisture removal system info. on YT,, See engineer Doug Kronemeyer's "DIY #9", 3 video series, loaded with engineers logic & knowledge at budget prices. Copy everything & get clean, super dry air BEFORE it rusts your tank out! Also a shoutout to Bud Stiner, THE Compressor Guru for tutorial DIY repair, diagnostic & parts. Good teaching, these guys! Good luck & learning Sir! Oh, yes also to a larger pilot/unloader valve to drain the air off the pump to stop leaks & make startups easy on the motor! Paul from S. Central Tx. (Temp was 102°F yesterday!

  • @mod_incllc3235

    @mod_incllc3235

    11 ай бұрын

    Great info here! I was going to add a similar comment but this covers it and more! It's been awhile and this is the first video of yours to show up in my feed. You're earned my sub just going through all that you did to make this compressor. After doing all that you did to fabricate/modify this compressor do you think it was worth all of the time, effort, and expense? I'd love to see a breakdown of each! Nice work. I'll check out some of your other videos.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    10 ай бұрын

    Thanks for the comment Cordell. I will be fixing this problem soon!

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    10 ай бұрын

    Thank you for the comment!

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    10 ай бұрын

    Thank you for the comment!!

  • @tonyash8080
    @tonyash80803 ай бұрын

    Do you have a check valve at the tank? Back feeding into the compressor head?

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    3 ай бұрын

    Stay tuned for my next video. I address the issue further. There is also a 2nd video to this project already on my channel. Thnx for the comment.

  • @ericschulze5641
    @ericschulze56413 ай бұрын

    I'm about to do the same thing with a craftsman, however I have decided to mount the pump and motor separately, the small bracket is designed for the lightweight small pump and motor, putting a longer mount will cause stress cracks and possible explosion, so unless you weld the bracket to the tank, like you see on similar compressors with sepeate pump and motor, your taking a big risk , so is welding to the tank ,I'd recommend mounting them separately from the tank

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    3 ай бұрын

    While I would assume this is a possibility to occur, I would think it is a mistake to assume this is the case for all situations. It is something to consider. In the situation of mine, the bracket is heavy and welded well. The tank is also in brand new condition. All situations will be different.

  • @ericschulze5641

    @ericschulze5641

    3 ай бұрын

    I wouldn't chance it, your old enough to remember putting 8 cyl. Engines in 6 cyl. Cars yea they were in perfect condition yea they worked. . . For a while. . . & then stress cracks developed and frames and suspension broke , putting double or triple the weight and vibrations on that bracket isn't a good idea, it WILL cause a stress crack

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    3 ай бұрын

    Once again, the condition of each situation is different and all the manufacturers and quality is different. I will chance it. It will out live me. Thanks for the comment.

  • @halfstep67
    @halfstep678 ай бұрын

    Do you have a check valve at the tank where the inlet line enters? If not, that is probably why you are leaking air thru the pump.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    8 ай бұрын

    I am currently trying to find a good check valve to use. Please watch my 2nd part of this video series!! kzread.info/dash/bejne/eqyLqNylnJvInLA.html

  • @EricHeran

    @EricHeran

    7 ай бұрын

    💯 the check valve would save your tank pressure, and relieve yourself of the backpressure. I am doing a twin pump conversion on my old husky I got almost 20 years ago. My single pump has made it for this long. I beat the tar out of that pump! Love the platform conversion, and I was so excited for you to discover the 3/4 npt! It really cleaned up the plumbing! Outside of the check valve this is a really fantastic model, and your skills and improvisation is apparent. I feel like I found my kind of people.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    4 ай бұрын

    Thank you for the comment!

  • @DesertSurfer
    @DesertSurfer8 ай бұрын

    I don't see a check valve in there or pressure bleed.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    7 ай бұрын

    Hopefully coming soon!!

  • @chrisjacobs1566
    @chrisjacobs15662 ай бұрын

    Don’t matter which side the motor is on. Clockwise is clockwise.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    2 ай бұрын

    What about if your in the southern hemisphere standing on your head Thnx for the education

  • @a.c.m.e.ink.4568
    @a.c.m.e.ink.45683 ай бұрын

    No more 'oilless' compressors for me. I learn my lesson after a nearly $300.00, purchase failed. Within 2 years time it died. It had replaced an old '1978' Sears lubricated compressor. The motor had failed on that one. That same compressor, just got a new motor & is working again.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    3 ай бұрын

    Sometimes you get a good one. Sometimes you get a dud. A guy i worked for, had a pancake style compressor of the same brand as I am renovating out. He had that thing for years and years. Who knows how many hundreds of hours of use.

  • @grahammctygue724
    @grahammctygue724 Жыл бұрын

    Can you change orientation of manifold to match you input ,hard line to tank should be fine pictured in strucktion,s be safe Peace

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    Жыл бұрын

    Possible. I think it might be obstructed by the electric box on the motor tho.

  • @thisone.

    @thisone.

    Жыл бұрын

    @@englishcustomworkshop6503 I have seen some suggest reversing the head of the pump so the outlet is on the opposite side, if it is symmetrical that is. Also if you want to reduce the db''s try adding an intake muffler. When I added one to mine it reduced it a good deal. Also adding sound deadener like rattletrap to the tank in a few spots can reduce the vibration/ the noise it creates. Kinda like a bell tinging sound.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    10 ай бұрын

    Thank you for the comment!

  • @alandavis4885
    @alandavis48856 ай бұрын

    I need a new head for that exact same pump! Any idea where to pick one up? Nice build btw! ... 😁👍

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    Sorry. I do not. Thank you for the comment.

  • @ericschulze5641

    @ericschulze5641

    3 ай бұрын

    Scrap metal guys, you have to keep stopping them and ask give them your phone number

  • @ericschulze5641

    @ericschulze5641

    3 ай бұрын

    Hey ! HE has one what's the deal ? He's probably going to throw it in the scrap pile, maybe he lives within driving distance or would take $50. For the pump

  • @christophersherratt7299
    @christophersherratt72994 ай бұрын

    You could of used a reinforced bath water pipe know soldering and put a check valve on to 80bar

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    4 ай бұрын

    Thnx for the comment

  • @mafed451
    @mafed4517 ай бұрын

    Your fitting is not npt. It’s an AN. You need to flare a piece of tubing then slide the coupling nut and a ferrule on and torque it down. Or get an AN hose with a 90 degree fitting on it to route under your platform.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    7 ай бұрын

    Thank You for the comment.

  • @halfstep67

    @halfstep67

    4 ай бұрын

    @@englishcustomworkshop6503 Both the AN and JIC are the same sized fittings. AN is Army/Navy fittings and have tighter thread tolerances than JIC. But both are cross-compatible. A lot of the AN fitting are aluminum and should not be used for hydraulics but the JIC can be used for anything that AN is used for. AN are often used for fuel/brake lines. AN sizes are in numbers like -6 or -8 or -10. Those number represent 1/16" so a -6 is 6/16 which is 3/8", -8 is 8/16 which is 1/2", -10 is 10/16 which is 5/8". There are smaller and larger sizes as well. Copper TUBING is measured from the OUTSIDE diameter. 1/2" copper tubing would have an outside diameter of 1/2" and an inside diameter of 3/8". Copper PIPE is measured from the INSIDE diameter. 1/2" copper pipe would have an outside diameter of 5/8" and an inside diameter of 1/2". If using 1/2" copper tubing, you would use an AN-8 size fitting or a JIC 1/2" fitting. If using 1/2" copper pipe, you would use an AN-10 size fitting or a JIC 5/8" fitting. Copper tubing and copper pipe comes in different types. Type K, Type L, Type M. Type K is the thickest walled and is mainly used when buried underground. Type L is a medium thickness and is commonly used for water lines for houses. Type M is used for light pressure applications. Even though these different Types will have different wall thickness, the outside diameter will remain the same, but the inner diameters will slightly change to accommodate the change in wall thickness. That way, the same fittings will fit the different Types. This applies for both tubing and pipe. Type L is 40% thicker walled than Type M. Type L has .40 thick wall and Type M has .28 thick wall. When using cooper pipe for air/water lines, use the Type L as it is stronger and is better for flaring. Standard plumbing uses a 45-degree flare but the AN and JIC use a 37 degree. So, when using AN and JIC, you will need to use a flaring tool that is 37 degrees. These 37-degree flaring tools are less common and more expensive. A cheap one runs about $50 and a good one runs about $140. Check Home Depot website for the good one. Som people will use a 45-degree flaring tool for the 37-degree flare and claim it will self-correct once the nut is tightened. AN fittings come is aluminum, steel, stainless steel. JIC comes in steel. Both the AN and JIC come in a lot of different configurations and adapters so there are many different options for reducing/expanding or going from NPT thread to AN/JIC. They will fit both tubing and pipe and flare fittings and compression fittings.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    4 ай бұрын

    Obviously took a long time to type all of that out. Appreciate the info. Thanks for the comment.

  • @alanshaw4655
    @alanshaw46553 ай бұрын

    pump is spinning the wrong way, fan blades should force air over the pump, not away from it, pump pully needs to spin counter clockwise sir.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    3 ай бұрын

    Thanks for the comments Alan! Hope you watch the follow on videos! New video coming soon. Please consider subscribing.

  • @mafed451
    @mafed4517 ай бұрын

    NAPA can make you a hose.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    7 ай бұрын

    Thank you.

  • @rayjones463
    @rayjones4633 ай бұрын

    on 1/4 inch like you have their it would have been faster to drill the 4 corner holes and use an angle grinder to cut 1 slot all the way between holes...oh well

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    3 ай бұрын

    Did not want a slot that long. Thanks for the comment.

  • @Fordcertian
    @Fordcertian6 ай бұрын

    When copper ages it turns brittle!

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    Its fine. Thnx for the comment

  • @denniscasey4967
    @denniscasey49676 ай бұрын

    😮😮😮. DiD YOU PUT PNE WAU VALVE FROM M

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    What??

  • @Fordcertian
    @Fordcertian6 ай бұрын

    How is compressed air possibly leaking through an oil breather for the pump, this is a red flag!

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    Who knows. Its foreign made. Thnx for the comment

  • @MarkK01
    @MarkK014 ай бұрын

    You should have broken in the pump by letting it run with no load for 30 minutes.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    4 ай бұрын

    Hello Mark Did you just make this information up? Do you have anything from a Harbor Freight manual that says this? Mine does not. Only that you change the oil after 1 hour of use. Which i did off camera.

  • @MarkK01

    @MarkK01

    4 ай бұрын

    @@englishcustomworkshop6503Any new compressor needs 1/2 hr of no load to break in the air compressor. This is not made up. In fact I watch another video where the guy got the pump from HF and he even confirmed that it needs 1/2hr no load break in.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    4 ай бұрын

    @@MarkK01 Not that its a bad idea. But just because someone on youtube says it, or a commenter says it, does it mean its true. It is NOT in my manual. Carry on Mark.

  • @MarkK01

    @MarkK01

    4 ай бұрын

    @@englishcustomworkshop6503I have had many compressors over the years and they all need a no load break in period. Whether it has been 15 -30 minutes. I do not want to start a argument with you. I am just going on my experience. And I have had some high end Makita compressors. You do what you want with this info. I am just trying to help you out.

  • @alanshaw4655
    @alanshaw46553 ай бұрын

    that is a compression nut, trying to screw onto a flare !..lol. its china..go figure !!. remove the flare crap all the way out of the air exhaust, install a reducer down to what ever size pipe you want to go into the tank.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    3 ай бұрын

    Thanks for the comment. Hope you watch the follow on video!

  • @alanshaw4655

    @alanshaw4655

    3 ай бұрын

    @@englishcustomworkshop6503 yep..watched it, you did great !.

  • @Fordcertian
    @Fordcertian6 ай бұрын

    Do not hook that copper up without a flex at top and bottom! Take a fools advice!

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    Its fine. thnx for the comment

  • @stuartnevins8098
    @stuartnevins80982 ай бұрын

    The money you spent on the motor and the pump you could have just bought a new compressor. What u did was bought two sandborne blackmax 3 hp belt driven compressors for seventy bucks each. I got a 60 gal tank and a 33 gallon tank for 125 for both. I synchronized to cut in and out and run them at the same time. For about 300 bucks i got 93 gallons of air and about 16 cfms. The set up works great and because its two it keeps the water to a minimum.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    2 ай бұрын

    I’ve got a great idea for you. Create your own youtube channel where you make your own videos. Film this masterpiece project of yours. Then let the internet tell you how you did everything wrong and spent too much money. And no, its not even close to the same amount as a new compressor. Thnx for the comment.

  • @MrMac5150
    @MrMac51506 ай бұрын

    Dislike the music, be better without it.

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    Some like it. Some dont. Cant make everyone happy. Not gonna try.

  • @denniscasey4967
    @denniscasey49676 ай бұрын

    😮😮😮,,,I DON'T THINK DIS GUY KNOWS WHAT DAY IT IS ,,,🤪🤪. VOTE BLUE FOREVER STAND TALL 🎉🎉🎉

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    6 ай бұрын

    Not sure?

  • @denniscasey4967

    @denniscasey4967

    6 ай бұрын

    @@englishcustomworkshop6503 😇😇. ,,WELL The QUESTION IS DO YOU KNOW WHAT HE IS OR IS .NOT DOING ❓ THIS CAT,,SURE PUTIN OUT THE TIME ,,, HE SEEMS TO DO THING ONLY ONE WAY. ,,,LOTS OS EXTRA WORK. ,,I've DONE THINGS JUST LIKE THIS YEARS AGO ,,, NICE JOB BHE DID IN KINDA FINISHING UNIT ,,, ONLY TIME WILL TEACH SOME FOLKS ,, HE DID WELL. SHOWING EACH STEPS ,,,,👍. No SURE BUT ONE POST VIDEO CHANGED LEFT OUT TANK ONE WAY CHECK VALVE OUT. ,,FINISH ,,, 140 PSI N TANK SHUT OFF ,,, AIR LEAKING BIG TIME THRU CRANK CASE VENT. , TANK PRESSURE Bleeding OFF BACK THRU COMPR. TANK BELEAF DOWN TO ZERO. ,,CHECK VALVE IN TANK. ,,, HIS LACK OF KNOLAGE OF TANK PRESSURE 140 OR 275 PSI THATS NOT THE TANK RATING. 2 TYPES OF TANKS ,, 1 NON CERTIFIED 2 IS CERTIFIED THEY WILL HAVE A WELDED INFO TAG ON TANK. ,,, THEY WILL TELL YOU # LIKE 250 AREA ,,WHAT HE SAYING IS THE RATING OF UNIT WHAT THE PIMP OUT PUT IS ,,NOTHING TO DO WITH TANK RATING ,,, DID NICE VIDEO BUT SOME THINGS NOT REAL ,,,MADE MY FIRST AIR COMP. GRAND DAD ,,,FATHER AND ME STILL HAVE IT TODAY,, FROM A TIME WHEN THERE WERE None TO BE HAD ONLY REAL UNITS ,,,NOW I HAVE 3 ,,SELL THEM ON THE SIDE ,,THANKS

  • @LouisDePalma-id8yy
    @LouisDePalma-id8yy4 ай бұрын

    Simple solution, get an lp flexable gas line to fit

  • @englishcustomworkshop6503

    @englishcustomworkshop6503

    4 ай бұрын

    Thank you for the comment.

  • @denniscasey4967
    @denniscasey49676 ай бұрын

    😮😮😮,, FROM COPPER TO TANK ❓ IF NOT PUMP HEAD CRANK CASE AIR LEAK. (( ONE WAY VALVE. )) AT TANK 140 PSI PUISH BACK THRU VALES PAST RINGS TO CRANK CASE VENT ,, NEEDEDTO SET UP DOFFERENT ,,, VOTE BLUE FOREVER STAND TALL 🎉🎉