Inside a cheap eBay fridge freezer thermostat

Ғылым және технология

A look at how capillary thermostats work and how to use them.
Capillary thermostats are a simple electromechanical thermal switch that uses a very thin metal tube to sense temperature at another location, by using the thermal expansion/contraction of liquid or gas to activate an adjustable switch.
The search keywords for finding a wide range of units on eBay are:-
"refrigerator thermostat"
Note that there are quite a few similar looking versions and a massive price range for the same thing.
If you enjoy these videos you can help support the channel with a dollar for coffee, cookies and random gadgets for disassembly at:-
www.bigclive.com/coffee.htm
This also keeps the channel independent of KZread's advertising algorithms allowing it to be a bit more dangerous and naughty.

Пікірлер: 404

  • @CanadairCL44
    @CanadairCL443 жыл бұрын

    "This is where it bursts and squirts unknown chemicals everywhere"! Carry On Clive!

  • @olipito

    @olipito

    3 жыл бұрын

    I once cut one of those tube-wires, the fluid was pretty much reactive with humidity and almost set my lab on fire!

  • @CanadairCL44

    @CanadairCL44

    3 жыл бұрын

    @@olipito Alcohol based.

  • @fallknight5405

    @fallknight5405

    3 жыл бұрын

    Sounds like the title of a 70's movie 'carry on Clive'

  • @olipito

    @olipito

    3 жыл бұрын

    @@CanadairCL44 thanks for the answer. Do you have more details on the chemistry of the fluid?

  • @aaronshapiro2542

    @aaronshapiro2542

    3 жыл бұрын

    same, but it was an oven one.

  • @Namirred
    @Namirred3 жыл бұрын

    6:14 because it's cold it will be retracted in, said every man.

  • @pear7777

    @pear7777

    3 жыл бұрын

    Clive doesn't, he starts working below 10°C

  • @chrishartley1210

    @chrishartley1210

    3 жыл бұрын

    3:35 and then Clive pulls Simon's knob off.

  • @spokehedz
    @spokehedz3 жыл бұрын

    BigCliveDotCom: Causing shipping managers everywhere to scream when they find out how much it costs to ship to the Isle of Man.

  • @bluerizlagirl

    @bluerizlagirl

    3 жыл бұрын

    It costs more to ship goods to the UK mainland from Europe now we have reintroduced customs formalities, though .....

  • @snigwithasword1284
    @snigwithasword12843 жыл бұрын

    "We don't know what it is, but here it is!" --99% of all online redistributers

  • @jkobain

    @jkobain

    3 жыл бұрын

    Well, not every Chinese seller is even this sincere!

  • @tomschmidt381

    @tomschmidt381

    3 жыл бұрын

    I've found that out. Makes explaining and resolving problems very difficult. eBay tends to favor buyers but I sometimes think sellers get the sort end of the stick.

  • @jkobain

    @jkobain

    3 жыл бұрын

    @@tomschmidt381 hahah, currently one seller on Ali ignores my messages after sending me the wrong item labelled as the one I ordered. Opening a dispute can help, maybe, but their immediate response was refusal explained like «delivered, ask your local post office or relatives about it». I mean… WTF? How could my local post office be responsible for a warehouse error?!

  • @IrishSkruffles
    @IrishSkruffles3 жыл бұрын

    Slightly unrelated: my father found previous work done on a commercial fridge, where the owners got a local handyman to fix it.. The handyman cut and joined a capillary pipe with a strip connector because he thought it was a wire and couldn't figure out why it still wasn't working...

  • @bostedtap8399

    @bostedtap8399

    3 жыл бұрын

    Brilliant!, You get what you pay for.

  • @Ivorbiggin

    @Ivorbiggin

    3 жыл бұрын

    That’s gold 👍

  • @DerMarkus1982

    @DerMarkus1982

    3 жыл бұрын

    I've witnessed sooo many people joining coaxial antenna cables that way, wondering why the signal's gotten even worse after their "repair"... But the capillary tube thing is new to me.

  • @christiangeiselmann

    @christiangeiselmann

    3 жыл бұрын

    How can people be that dumb?

  • @jlucasound
    @jlucasound3 жыл бұрын

    His name is "Nowis", Clive!! You wrote it right on the side of the device!! ;-)

  • @theskett

    @theskett

    3 жыл бұрын

    I was also troubled by this, for the first minute or two :-)

  • @CanadairCL44
    @CanadairCL443 жыл бұрын

    This brings back memories of when I was a quality manager, setting up inspection section procedures at a domestic gas boiler manufacturer, in the mid 1980's. Best job I've had in years!

  • @BRUXXUS
    @BRUXXUS3 жыл бұрын

    Pretty "cool"! I'd never really thought about these before, but the engineering is really pretty elegant. I also really love the tiny metal accordion.

  • @bigclivedotcom

    @bigclivedotcom

    3 жыл бұрын

    Just a few pounds/dollars on eBay if you want one for the bits.

  • @darkmann12

    @darkmann12

    3 жыл бұрын

    heh hey there bruxxus

  • @BRUXXUS

    @BRUXXUS

    3 жыл бұрын

    @@darkmann12 Howdy!

  • @arty1799

    @arty1799

    3 жыл бұрын

    The tiny metal accordion is a bellows ( en.wikipedia.org/wiki/Metal_bellows ). The processes for making them are pretty cool. For long lived thermostats they can be made by hydroforming ( kzread.info/dash/bejne/homVz5aMeMW0eto.html ) or electrodeposition ( kzread.info/dash/bejne/gYiGlrWDgrnJc9I.html ). The bellows in Clive's video were most likely hydroformed as they are much cheaper. Hats off to Clive for educating and entertaining us!

  • @johndododoe1411
    @johndododoe14113 жыл бұрын

    The capillary full length sensing fridge thermostat is designed to be installed entirely inside the fridge, turning the knob only with the door open.

  • @Mtematiks

    @Mtematiks

    7 ай бұрын

    Thats true, but MOSTLY if you have a freezer inside, the eond of the tube is IN CONTACT wirh the wall of the freezer!

  • @johndododoe1411

    @johndododoe1411

    7 ай бұрын

    @@Mtematiks Thermostat regulates compressor runtime to keep main fridge compartment at the set point , Supplemental freezing box gets whatever it gets by thermal design, not by touching any sensor .

  • @peregrine1970
    @peregrine19703 жыл бұрын

    "so you can't RAM IT RIGHT PAST THE END STOP." Gig-gi-ty.

  • @CanadairCL44

    @CanadairCL44

    3 жыл бұрын

    Shades of Quagmire LOL !

  • @sootikins

    @sootikins

    3 жыл бұрын

    "Ouch!" said her cervix.

  • @jumboegg5845
    @jumboegg58453 жыл бұрын

    Love your work Clive. The last thermostat you pull apart you refer to its calibration screw. I think that screw is actually the "differential" temp setting, it works like a sensitivity setting, by adjusting the tension on the spring mechanism. The user-adjustable knob sets the temp at which the thermostat turns off . The sensitivity setting adjusts the temp at which the thermostat turns on, which for fridges and freezers is fixed at about 3 - 5 degrees above the temperature set by the user.

  • @PaulSteMarie
    @PaulSteMarie3 жыл бұрын

    The sleeving on the capillary tube is probably to avoid getting kinks. That's a very common failure mode for these things. Most of the waterbed heaters that I've owned over the last too many years have used those stupid bulbs and capillaries. I was really happy to get one that had a thermistor to put underneath the mattress and nice flexible wires instead of that damn bulb. As far as prying up tabs goes, you should get yourself one of the chiplifters from Wiha. They are essentially a miniature crowbar with an end that's maybe 1/8 inch across and curved so that you get leverage to bend things up.

  • @glenn1524

    @glenn1524

    3 жыл бұрын

    the isolation provided by the sleeving is a fine tune for the system

  • @billssolarpowerandgardenin1016

    @billssolarpowerandgardenin1016

    3 жыл бұрын

    Mostly they are insulated to avoid shorting on bare electrical and objects running into it rubbing a hole. Forgot to unplug a unit on a repair and got too close to the terminals inserting the capillary tube and pop! Off to see the wizard for another one.

  • @obelixer9751

    @obelixer9751

    3 жыл бұрын

    Yes, it's purely for electrical insulation, the center screw is for calibration. It's just a run o the mill thermostat. High temperature regulators could "explode" at the moment you cut it like he just did.

  • @tomhoehler3284
    @tomhoehler32843 жыл бұрын

    The little "diaphragm" on the second unit is typically called a bellows.

  • @AndrewGillard
    @AndrewGillard3 жыл бұрын

    Ah! So that's what those things in my oven are! I've had to remove our oven from the fitted kitchen cabinet four times¹ in the past year to replace the mode selector switch and then one of the heating elements, and I saw these two metal tubes leading from the thermostat dials to each of the two ovens, so they were clearly for temperature sensing but, only being familiar with thermistors, thermocouples, PT100s, and similar *electronic* temperature sensors, I was expecting something like that (i.e. at least 2 wires), so only seeing a single metal tube totally confused me! ¹ Removing it twice per replaced item: once to get the details of the broken part that needed ordering, then later to actually replace it. The heating element was less than £10 from Amazon, so I was a bit doubtful about it, but it's been working fine for a few months already. Although with the amount of time it takes to replace the heating element on my oven, it'd *definitely* be better to buy the ~£30 version if this £10 part fails in short order!

  • @zh84

    @zh84

    3 жыл бұрын

    Since I was a child I have imagined that the thermostatic control in an oven works by means of a bimetallic strip. I am fascinated to learn that I was completely wrong and ovens use an entirely different principle.

  • @snigwithasword1284

    @snigwithasword1284

    3 жыл бұрын

    Likewise I would have been dumbfounded! Good on you for knowing the value of your labor!

  • @bluerizlagirl

    @bluerizlagirl

    3 жыл бұрын

    @@zh84 You don't need the amplifying effect of two different metals with the temperature difference between an oven and ambient. Now, the hob controls _do_ use a bi-metallic strip; only it is not actually sensing the temperature of the cooking ring, but a separate little heating element which just heats the bi-metallic strip. This and the ring are wired to come on together, so the rate at which energy is delivered to the food (i.e., the mean power output) is proportional to the mean power output of the thermostat's own little private heater, which you adjust with the knob. It's an example of a feed-forward control system.

  • @zh84

    @zh84

    3 жыл бұрын

    @@bluerizlagirl Interesting! I had no idea that's how it worked. Thank you. I took a lot of things to pieces in my childhood, but never a stove.

  • @SimonPain
    @SimonPain3 жыл бұрын

    I've learned a new excuse: "I didn't drop it, those are calibration dents"

  • @JuanJose-tn8yd

    @JuanJose-tn8yd

    3 жыл бұрын

    Nop, thoses are "speed holes" xD

  • @WineScrounger

    @WineScrounger

    3 жыл бұрын

    Dent tuning waveguide is a thing. Kinda alarming the first time you see it done but it’s very effective.

  • @andreasu.3546

    @andreasu.3546

    3 жыл бұрын

    I'll try this next time retuning a rental car.

  • @BrendanPerkins
    @BrendanPerkins3 жыл бұрын

    Those big bulbous knobs would look good on my steam punk electric guitar. 🎸 Especially going up to 110, it'll make it louder. 😉

  • @RedwoodRhiadra

    @RedwoodRhiadra

    3 жыл бұрын

    If you put on the -30 to 30 knob, does the guitar start sucking sounds from the air, making it quieter as you play?

  • @BrendanPerkins

    @BrendanPerkins

    3 жыл бұрын

    @@RedwoodRhiadra That's got to be worth a try. 😂 I need a new guitar amp, my old one definitely sucks!

  • @soranuareane
    @soranuareane3 жыл бұрын

    "Panty rings for extra security while horse-riding." There's so much to unpack in that little sentence.

  • @BRUXXUS

    @BRUXXUS

    3 жыл бұрын

    😂🤣😂

  • @jindivik321

    @jindivik321

    3 жыл бұрын

    i laughed out loud at this :D taking the piss out of the panty liner adverts but delivers it so deadpan like. love it :D

  • @jamesplotkin4674

    @jamesplotkin4674

    3 жыл бұрын

    Today's "liberated" female rides "free bleeding" as well as runners. Eww...

  • @bluephreakr

    @bluephreakr

    3 жыл бұрын

    wings*

  • @ChrisD4335
    @ChrisD43353 жыл бұрын

    almost a half hour of big c pulling his knob, thats hot!!!

  • @Taristin
    @Taristin3 жыл бұрын

    Look up the MSDS (material data safety sheet) for a Honeywell aqua stat. They list their capillary liquid as a mix of Mineral oil, lithium hydrostearate, Zinc Alkyldithiophosphate, and a few other aluminum components, and stearates. I looked it up on a job one day when I had gotten it all over me. Wanted to know if it was carcinogenic. They say it isnt.

  • @tncorgi92

    @tncorgi92

    3 жыл бұрын

    Similar thing happened to me with a barrel of MEK. Isn't it great that everything can be found online? Whereas before shops had to keep volumes of paper.

  • @tin2001

    @tin2001

    3 жыл бұрын

    They say it's not carcinogenic, but I bet when they sell it in California it has that famous cancer sticker on it 😂

  • @RicoElectrico

    @RicoElectrico

    3 жыл бұрын

    @@tin2001 Known in the state of Cancer to cause California ;]

  • @zh84
    @zh843 жыл бұрын

    16:11 "This has little wings that fold round, little pantie-wings that fold round, for extra security when you're horse-riding." And those who watched ITV in the 90s may understand why this makes me think immediately of "UUUAAAAARRGH, BAAHDYFORM!"

  • @nixxonnor

    @nixxonnor

    3 жыл бұрын

    LOL :D

  • @minkymootwo

    @minkymootwo

    3 жыл бұрын

    I wonder if those little wings stick to hemp panties?

  • @WineScrounger

    @WineScrounger

    3 жыл бұрын

    I haven’t heard it in years and you made it play back perfectly in my head. God punish you.

  • @jindivik321

    @jindivik321

    3 жыл бұрын

    There's a Mr.Bean episode where he can't sleep. He puts the TV on and there's a chess tournament, he's about to nod off and the Bodyform ad comes on and scares the crap out of him :D

  • @jkobain
    @jkobain3 жыл бұрын

    A couple of days ago I had to explain how thermostats like these work. I reckon I preformed not really bad, but now that Clive has emerged on topic, I can get back to the discussion again and demonstrate this video. Because it should help even more. Thank you, as always.

  • @alunthomas3789
    @alunthomas37893 жыл бұрын

    I always wondered how these thermostats worked. Thanks for the video it was very informative.

  • @joaoliduario
    @joaoliduario3 жыл бұрын

    The 1st time I dealt with one of these I thought that tubing was an encapsulation for the sensor(that I thought was a thermocouple, thermal transistor, etc). I opened the vial and, to my huge surprise, it came out an oily fluid. I washed my hand several times, because I didn't know if that could be poisonous. It turns out that the oven was 100% electro-mechanical. I remember taking some time to understand what was going on, but eventually came out with the conclusion(that was correct). I love these mechanisms... they are like puzzles.

  • @ferrumignis

    @ferrumignis

    3 жыл бұрын

    _"was 100% electro-mechanical"_ Quickly converted to 100% dysfunctional 😁

  • @davida1hiwaaynet
    @davida1hiwaaynet3 жыл бұрын

    Hi Clive. I'm heavy into antique and vintage refrigeration equipment. The ones with the saturated vapor capillary tube are very common with the old fridges. They depend on the sensing tip of the tube to be cooler than the body and diaphragm of the switch. The vapor pressure of the working fluid is what really gives these their accuracy. I've made several videos of rebuilding these when the sensing line gets broken. Depending on the temperature range the control was designed to work at, they used different working fluids. Some of them used sulphur dioxide; methyl chloride, Freon-12, isobutane, or propane. When rebuilding the fridge thermostats, if you can determine the temperature it is supposed to switch it, you can apply gas pressure and determine what pressure triggers the switch. With that information, you can consult pressure-temperature charts and find a suitable refrigerant gas to use for a working fluid. One of the original manufacturers of the vapor type thermostats is Ranco company. They have been in it for decades and have published quite a lot of repair info in the past decades. Ranco are still around and still very high quality. I think the second one you had in this video was a Ranco knock-off. Many of the ones I've rebuilt recently ended up with butane being the correct gas. Back in the old days, they referred to the ones with the expanding fluid (like the first one you worked on) as "hydraulic" thermostats. The ones with saturated vapor were called "gas" or "vapor" thermostats. I've been wanting to study and learn to repair the "hydraulic" type of controls. There are few who repair them when the capillary tube gets broken. The secret (as you said) is in the thermal expansion coefficient of the working fluid. Here's an isobutane thermostat getting repaired: kzread.info/dash/bejne/iXyqm7etZ8rbp6g.html This one was originally methyl chloride, but I used 1,1,difluoroethane for it. It's almost like your second one you showed. In spite of being very similar, it's from back in the War of the Currents era in the States. Back when AC and DC were both competing technologies. Love the old stuff! Repair video: kzread.info/dash/bejne/emuKs9usYcq2ms4.html Thanks for the teardown video! I enjoyed it a lot. I hope you enjoy seeing my repair videos on these.

  • @jmc1771

    @jmc1771

    3 жыл бұрын

    You are spot on. Glad I read through and didn't repeat your comment.

  • @jabroski69

    @jabroski69

    6 ай бұрын

    I do HVAC cold and hot side equipment repair you got yourself a sub good sir I love old equipment your living my dream homie I'll be there one day

  • @davida1hiwaaynet

    @davida1hiwaaynet

    6 ай бұрын

    @@jabroski69 Thank you, much appreciated!

  • @PhilipLeitch
    @PhilipLeitch Жыл бұрын

    Big Clive for the save! Helped me confirm my freezer thermostat was working perfectly

  • @Somanathan-hj7ge
    @Somanathan-hj7ge Жыл бұрын

    You are practical as well as theoretical, very good sir

  • @amorphuc
    @amorphuc Жыл бұрын

    Fascinating! Thanks Big Clive! It's kind of wild that so little movement will control our appliances. The gas one seemed pretty simple until you delved into its inner workings. Such seemingly simple little pressed metal bits and springs creating something of fairly complex actuation. I think those engineers have earned their keep!

  • @lathiat
    @lathiat3 жыл бұрын

    This was very helpful i was trying to figure this out after watching HVACR videos. A quick google was failing me but explained in the first 30 seconds. Sometimes the capillary connects to the system or to a bulb but either way the point of the capillary is to transfer the pressure with a small impact of the volume of the capillary.

  • @K2teknik.
    @K2teknik.3 жыл бұрын

    The two with a vial are for sensing the room/box temperature, the last one is made to sense on the evaporator, and it matters a lot to get the right type for your application.

  • @deepblueskyshine
    @deepblueskyshine3 жыл бұрын

    Over the years I've changed lots of these - ovens, water boilers, water and oil filled heaters. I've never seen any fault different from spring relaxation of the switch mechanism caused by faulty contacts overheating it. Expanding sensor-actuator part might be a dark sciense for a lazy person, but the spring mechanism of the switch is a real engineering voodoo. Changing heater thermostats in my very old apartment, however, became a very difficult task - they were made in England, but apparently no more so getting new one is a quest of walking through all spare parts shops without websites in criptic parts of the town.

  • @scorchio70
    @scorchio703 жыл бұрын

    Love all your content Clive, please don't ever stop, I could watch and listen to you explain just about anything. (Loved your hot dog video, watched it from start to finish, were they friends , family or both?)

  • @nixxonnor
    @nixxonnor3 жыл бұрын

    You do it like Dave. You take it apaat... Awesome analysis of the thermostats at hand.

  • @68pishta68
    @68pishta68 Жыл бұрын

    @15:28 the knob does not rise and fall to the case, the red rotating wedge increases or decreases the force on the diaphragm lever changing its position and/or resistance to movement creating a manually variable switch on/off state. @20:31, you got it!

  • @stridermt2k
    @stridermt2k3 жыл бұрын

    A delightful exploration! In our scrap area at work I'm always finding rolls of copper capillary tubing that have been cut. Always wanting to find a use other than a magnetic loop antenna. LOL

  • @bigclivedotcom

    @bigclivedotcom

    3 жыл бұрын

    You could wrap it round a heating element to make a simple smoke machine. Not sure how long it would last though.

  • @stridermt2k

    @stridermt2k

    3 жыл бұрын

    @@bigclivedotcom that just sounds like me getting in trouble at work... I'll get right on it! LOL

  • @jaymartinson3236
    @jaymartinson32366 ай бұрын

    The last thermostat you took apart is indeed for a freezer. My Arctic King 5 cubit foot chest freezer has the exact same thermostat. It's so cheaply made that over time, the small vibrations of the compressor cause the set screw to turn, which causes the freezer to to stop getting as cold after a few years. Most people just throw the whole unit away, but it can be fixed by simply adjusting the set screw on the side. Mine is especially bad and has had to be adjusted twice in 3 years. Meanwhile, the freezer on my fridge from the 1970s has been holding 0°F for 40 years and hasn't missed a beat. It's sad how cheaply things are made now.

  • @lefty5349
    @lefty53493 жыл бұрын

    The last thermostat you showed is a typical fridge variety, it is nearly always mounted inside the fridge, at the back right next to the evaporator. So the whole of the unit is essentially in the conditioned space.

  • @pleasecho2
    @pleasecho23 жыл бұрын

    These "hydraulic" thermostats had to be calbrated for use in high altitudes. Also if you can find an old Cutler-Hammer thermostat, they not only have a method of calibration but separate screws for adjusting the cut-in and cut-out.

  • @davidv1289
    @davidv12893 жыл бұрын

    The capillary only thermostat is designed to be mounted inside the conditioned space (frig or freezer) and as you said uses the tube and bellows for temperature sensing. The screw and attached spring assembly make up the span adjustment - the difference in temperature between on and off - and the other screw is the calibration adjustment.

  • @redlock4004
    @redlock40043 жыл бұрын

    The Opening Things Up Channel.

  • @user-jy5ff3zo3u
    @user-jy5ff3zo3u3 жыл бұрын

    Love the commentary brother 😁

  • @why_do_you_want_to_know
    @why_do_you_want_to_know Жыл бұрын

    The third type (without bulb but with big bellow diaphram) is used in 5 gallon bottled water dispensers which usually have two thermostats. One for chilling side of dispenser and second for heating side so you can get hot water for tea/coffee or cold water for drinking. The capillary tube of each is wrapped around respective small insulated heated or chilled water holding tanks. Temperature setting shaft for chilled water tank is either inside dispenser case (for factory adjustment only) or extends outside but without any knob or dial scale for user adjustment.

  • @mickpress6718
    @mickpress67183 жыл бұрын

    movement of the drum has to be slight as it is magnified by the armature due to its closeness to the pivot

  • @TechTheGamer
    @TechTheGamer3 жыл бұрын

    On the freezer thermostats I’ve seen that are mounted inside, they have all been filled with some type of refrigerant. Interesting to see one that is just oil. I believe you can tell the difference by not only the diaphragm but also the expansion bulb. The oil ones appear to have a much larger surface area for the expansion bulb whereas the ones with a refrigerant have extremely small, almost non-existent expansion bulbs. Probably due to the thermal sensitivity of refrigerants.

  • @stufish4040
    @stufish40403 жыл бұрын

    Fantastically entertaining. I've irretrievably broken SO many things , over the years, by taking them apart to " see how it works" :D

  • @phils4634
    @phils46343 жыл бұрын

    Dead simple (and remarkably reliable) mechanism! Able to (reliably) switch decent current too, so an example of excellent (although nowadays decidedly "legacy") engineering. As you say, almost "everything" these days will be electronically controlled (pre-programmed PID controllers) which (though offering far closer control ranges) do seem to be far less reliable, despite "no moving parts inside".

  • @davidrichardson376
    @davidrichardson3763 жыл бұрын

    The volume of the bellows/diaphram is much larger than the capiliary and is therefore gas operated, since the diaphram movement is large enough to operate a microswitch. The refrigerant in the system is presurised and boils at a certain pressure (set by the setpoint dial spring pressire on the diaphram) thus increasing it's volume and operating the microswitch.

  • @graemezimmer604
    @graemezimmer6043 жыл бұрын

    I think the "gas" would be something like Freon, and it's transition from liquid to gas depends on the temperature and pressure (the state transition giving much more decisive action). Plus the two adjustments are to set the amount of Hysteresis as well as the Temperature.

  • @TuttleScott
    @TuttleScott3 жыл бұрын

    'it could be some oil or...." me waiting for him to taste it....

  • @blun5734
    @blun57343 жыл бұрын

    Love your channel! You're accent sounds just like Scott Manley of KSP fame!

  • @cyberhornthedragon
    @cyberhornthedragon3 жыл бұрын

    i worked in a valve manufacturer several years ago an i had the job of putting thermal switches on the valves with electronics an comtrolers valve positioners 'most' of the thermostats i had to work with it was a highly refined mineral oil as it wont freeze an has a high boiling vapor point

  • @deathlydarkness
    @deathlydarkness3 жыл бұрын

    Clive, I also see this style of thermostat in Boilers for coffee and other dispensing equipment.

  • @bigclivedotcom

    @bigclivedotcom

    3 жыл бұрын

    Similar units.

  • @richiep7812
    @richiep78126 ай бұрын

    Still in common use all of this. The square one is a simmer stat used for catering trolleys. Some say there temperature range on the side.

  • @getyourkicksagain
    @getyourkicksagain3 жыл бұрын

    The unit you disassembled after 13:00 looks almost _exactly_ like the thermostat used in my 1986 Suzuki Samurai's A/C system. Mine only has 2 contacts, though.

  • @dimitar4y
    @dimitar4y3 жыл бұрын

    you're good at making stuff up as you go :0

  • @mendaliv
    @mendaliv3 жыл бұрын

    The MSDS I found for one remote bulb thermostat said it contained toluene. A Honeywell datasheet for a different unit said the bulb fill could be toluene or silicone oil. These both appeared to be for HVAC applications.

  • @Nono-hk3is
    @Nono-hk3is3 жыл бұрын

    "A chap called Nowis"

  • @IanSlothieRolfe

    @IanSlothieRolfe

    3 жыл бұрын

    I'm glad it wasn't only me who wondered who "Nowis" was in the opening seconds of the video... :D

  • @tweed532
    @tweed5323 жыл бұрын

    Others have mentioned the last one used in fridges, 'Off and then numbers', no specific temperature setting. I like a cold, cold fridge and on mine, the two screws going into the springs I've tweaked before now to set the low and high temp it cycles at, making it narrower hysteresis band than stock. (Usual disclaimer in case yours wasn't like mine. 😉)

  • @dariandelparte9720
    @dariandelparte97203 жыл бұрын

    its common for the capillary type to be embedded in the evaporator coil to sense to temperatures of the coil itself, another reason why the temperature range is so low. the contacts that stay closed all the time are for your evaporator fan motor to run 100% of the time, the other contacts switch your compressor and condenser fan on. from what i've been told by industry, most of these liquids are a refrigerant of sorts.

  • @heavydiesel
    @heavydiesel3 жыл бұрын

    Remember the old Teddington QR stats, they used sulphur dioxide as the sensing gas!

  • @WineScrounger

    @WineScrounger

    3 жыл бұрын

    Just to be extra manly? Seems reasonable. I’ll take three.

  • @heavydiesel

    @heavydiesel

    3 жыл бұрын

    @@WineScrounger probably 40 years ago now i think about it, used to help dad out at work on school holidays!

  • @WineScrounger

    @WineScrounger

    3 жыл бұрын

    @@heavydiesel cool stuff. I can’t see sulphur dioxide passing the sniff test these days. Although I do wonder if some thermostats would rely on a phase change for temperature sensing. Maybe that’s the reason?

  • @Mtematiks
    @Mtematiks7 ай бұрын

    Hi Clive, The small thermostat is full with ether!

  • @RedFathom
    @RedFathom3 жыл бұрын

    the small tube one uses vapor. the liquid-vapor change doesn't need much contact area, and the pressure inside changes the temperature at which it condenses/evaporates.

  • @davejordan6922
    @davejordan69223 жыл бұрын

    The last one with the coppery diaphragm is almost certainly out of a mini fridge. I had to replace one just the other day. it has the same diaphragm, three terminals, and the gray plastic section attached to the aluminum section. the form factor appears to be identical. although the guts are slightly different.

  • @phils4634
    @phils46343 жыл бұрын

    Might be a nice contrast to take apart one of those Chinese electronic thermostats (such as the ever-popular Willhay WH360, which seems to be everywhere on the "usual sites"!) They work pretty well, seem reliable enough (ours have lasted 10+ years with zero problems), and have enough added functionality to be of use in heating and cooling applications.

  • @Gold63Beast
    @Gold63Beast3 жыл бұрын

    14:30 I’m still working on my carefulness lol. Always have little scrapes, cuts on my fingers from tinkering.

  • @RedaReda-uk9lm
    @RedaReda-uk9lm3 жыл бұрын

    I think that liquid is called a refrigerant it could be HFC example R134a. Thanks Sir

  • @throttlebottle5906
    @throttlebottle59063 жыл бұрын

    at 2:55 that type is common in many refrigeration uses, the other mistake is not winding the excess sense tube into a coil and making sure to place it away from the refrigerant tubing (suction or pressure) with will skew it greatly, especially in the sense of a deli display case (learned the hard way)

  • @bigclivedotcom

    @bigclivedotcom

    3 жыл бұрын

    Likewise with a fat fryer when the tube touched the element.

  • @eddybash1342
    @eddybash13423 жыл бұрын

    Thank you Sir Big Clive ! ;)

  • @Aengus42

    @Aengus42

    3 жыл бұрын

    If knighted he would be Sir Clive of Big. ⚔️

  • @Peter_A1466
    @Peter_A14663 жыл бұрын

    You really got me shouting at my screen this time 😁 The gassy one might have been liquid within it's operating temperature range... And the more narrow the diaphragm, the bigger the travel for a given expansion of the medium used.

  • @ferrumignis

    @ferrumignis

    3 жыл бұрын

    That type tends to use a small amount of a low boiling point refrigerant such as butane or freon in the bulb,which is gaseous under the relatively low pressure within the capillary. Since the temperature coefficient of expansion is much higher for a gas, but the force that can be applied it much lower (since gas is compressible) the bellows is constructed to deal with much more movement than the liquid based thermostat.

  • @Peter_A1466

    @Peter_A1466

    3 жыл бұрын

    @@ferrumignis I was thinking it would be most effective during it's transition fase...

  • @chrisw1462
    @chrisw14623 жыл бұрын

    The two screws on the front are for calibration - they set the depth of the stem (the first thermostat).

  • @k4be.
    @k4be.3 жыл бұрын

    I have disassembled multiple water heater thermostats years ago, and all of them contained ether, with Li-ion electrolyte smell and instant evaporation.

  • @zlatkojurkovac6981
    @zlatkojurkovac69813 жыл бұрын

    Hey Mr. Clive! Thanks for your great videos, really like them 110% and watching almost every one - one sentence - you are a genius at your filming and knowledge about almost everything that comes to your bench... Being a handyman myself, i only would like you to return to your "dark and dodgy" videos about some strange invention that you came across on ebay or your old projects that you made. If you could "return" to some older stuff, i personally would be very happy :) Thanks and best regards, Zlatko

  • @zlatkojurkovac6981

    @zlatkojurkovac6981

    3 жыл бұрын

    Thanks for liking my comment! Coming from you, i take it as an honor if you like :) I humbly noticed that your videos from 3 or 4 years ago, like with your boiler house oil heating cutting off in the middle of winter, ended with a pocket heater disassembly, repairing some strange emergency light, auto power generator switch from china from tomzn, leaking house copper heating pipes that have potholes from manufacturing and stuff like that was, at least to me personally much more interesting. I personally would like more videos along those iffy lines if you know what i mean :) There are so many blend videos about ordinary things, and i think that you can and know how to do it better :) This is my humble opinion, by the way, NOT a critic in any way... Thanks for your videos, they take my day up, watching every one :) Sorry for my chinglish... :) Thanks and keep it up! BR Zlatko Jurkovac

  • @nomusicrc
    @nomusicrc3 жыл бұрын

    I love this video he wasn’t slurping a drink or masticating

  • @ShadowzGSD
    @ShadowzGSD3 жыл бұрын

    3:33 i will be pulling my knob off later 🤔😬

  • @jayer898
    @jayer8983 жыл бұрын

    who else thought it was from a person called nomis. lol love the videos clive keem em comming.

  • @soupflood
    @soupflood3 жыл бұрын

    A single 555 or an op-amp can also be used to make a fridge thermostat (if you don't have a microcontroller based one). The only trouble is that a 3...5 minutes pause should be implemented between turn-on and turn-off.

  • @Peter_S_

    @Peter_S_

    3 жыл бұрын

    That's why you use a 556.

  • @soupflood

    @soupflood

    3 жыл бұрын

    @@Peter_S_ good point, Peter: use a 555 as timer for another 555

  • @Peter_S_

    @Peter_S_

    3 жыл бұрын

    @@soupflood long delays with the 555 get a bit random, but that's tolerable for a compressor delay. I was recently looking at the oscillators of the Roland Jupiter-4 synthesizer who's arpeggiator was made famous by Duran Duran in Rio, and the oscillators actually use a 555 to trigger a reset of each oscillator period. What a great chip.

  • @soupflood

    @soupflood

    3 жыл бұрын

    @@Peter_S_ i was still thinking about the one 555 delaying another 555, but that only works at power-up, not between each disconnect of the compressor after it reaches set temperature. I guess only 555 can't maintain a delay between compressor cycles too, for example to avoid premature turn-on if the door has been opened right after compressor shut down.

  • @Peter_S_

    @Peter_S_

    3 жыл бұрын

    @@soupflood Hmmm.. As a digital nerd, my first thought is usually, "is it cheating to add a couple 4000 series chips?", but I don't think it's necessary here. I think if you use the first 555 as a comparator where the output provides a little hysteresis via a feedback resistor and the discharge pin is otherwise floating, and then use the output of that 1st timer to trigger the 2nd timer wired as a delay where the discharge pin on the first timer is actually used to discharge the cap on the 2nd timer and the 2nd timer's discharge pin is left floating, you can end up with a comparator with hysteresis that triggers an RC delay to finally start the compressor after a delay which is retriggered any time its called to start. Maybe the connections for the delay would be a resistor from 555-A pin 3 to 555-A pin 7 and 555-B pin 6 to the cap to ground. If I had a 556 handy I would breadboard it.

  • @robbatley
    @robbatley3 жыл бұрын

    Commonly use toluene as the working fluid in most of the displacement type of thermostats.

  • @johndododoe1411
    @johndododoe14113 жыл бұрын

    Many freezers have a fast freezing mode that runs the compressor continuously when freezing large amounts of fresh produce.

  • @getyourkicksagain
    @getyourkicksagain3 жыл бұрын

    I was today years old when I learned NOWIS is SIMON upside down.

  • @stephenbrown5927
    @stephenbrown59273 жыл бұрын

    It is a freezer stat the reason for the the extra terminal is it brings on a red warning light about 10 degrees above the set temperature so you can see there might be a problem. The capillary only need about 80mm in the cold area to work as the pressure will change even if only a small amount is cold area.

  • @eDoc2020

    @eDoc2020

    3 жыл бұрын

    That makes sense. My family's old freezer has a neon on the front which has gotten disconnected sometime in the past several decades. A warning light makes more sense to me than a 'plugged-in' light.

  • @TheWhiteAfghan
    @TheWhiteAfghan3 жыл бұрын

    the 3rd contact is just a line jumper that sends 120v to board for the "fast cool" feature. All it does is bypass the thermostat and power the unit to start cooling when you hit the button

  • @jimlagraff4989
    @jimlagraff49893 жыл бұрын

    So you after you got your fingers messy, you peeled back the protective wings, crushed the diaphragm and the lost your mind for minute as stuff sprung out? That's more fun than I had last night!

  • @carlosmolina3850
    @carlosmolina38503 жыл бұрын

    we use silicon oil or glycerine as transmission liquid in diaphragm seals :)

  • @samoljubesic6275
    @samoljubesic62752 жыл бұрын

    Great!!!

  • @barryjackson2351
    @barryjackson23513 жыл бұрын

    the capillary is usually filled with refrigerant r22 or butane

  • @bigclivedotcom

    @bigclivedotcom

    3 жыл бұрын

    This was an oil that lit when heated.

  • @barryjackson2351

    @barryjackson2351

    3 жыл бұрын

    @@bigclivedotcom the refigerant is under pressure with a minute bit of oil in

  • @paulspaws1521
    @paulspaws15213 жыл бұрын

    While repairing appliances I noticed that when some of these are broken the contents of the probes sometimes ignite quite spectacularly when exposed to air, shame you didn't get one like that, I always found it amusing.

  • @bigclivedotcom

    @bigclivedotcom

    3 жыл бұрын

    I lit the liquid one. It took a lot of heat, but then burned.

  • @markdavies794
    @markdavies7943 жыл бұрын

    Typical, I spent 2 hours today diagnosing why my fridge/freezer was not working. I figured out it was the thermostat then figured out the diaphragm was not working. I could have saved myself a lot of time if I had watched this vid first!

  • @phonotical
    @phonotical3 жыл бұрын

    In the stream tonight, could you maybe explain how a mercury rectifier actually makes current dc? (and he never did)

  • @willi-fg2dh
    @willi-fg2dh3 жыл бұрын

    reminds me of the sensor that shuts off the gas to the pilot light on older gas appliances (the water heater and furnace in my folks house, for instance) those were almost bulbless.

  • @bigclivedotcom

    @bigclivedotcom

    3 жыл бұрын

    That was possibly a thermocouple. Generating just enough current to keep a magnetic valve engaged.

  • @willi-fg2dh

    @willi-fg2dh

    3 жыл бұрын

    @@bigclivedotcom thanks, sounds about right. there was an odd setup in the controls, tried to replace the old mercury tilt-switch thermostat with a programmable thermostat . . . the system put such a low voltage on the line that the new t-stat couldn't switch it without so much loss that the furnace would never come on . . . i think i measured it at less than 1v. might have worked with a relay type t-stat but all i had was a transistor(?) switched one. the system would switch on and off even when the power was out . . . i wonder if the installer used a thermocouple source for power?

  • @eDoc2020

    @eDoc2020

    3 жыл бұрын

    @@willi-fg2dh Yes, I believe those systems usually use a thermopile (several thermocouples in series). It's called a 'millivolt' control system.

  • @ILikeStyx
    @ILikeStyx3 жыл бұрын

    Ugh... I've a similar kind of thermostat in my HVAC heat pump, line voltage mechanical thermostat... its temperature range fluctuates so it's terrible to manage, getting it replaced with a digital thermostat this spring :)

  • @bunnykiller
    @bunnykiller3 жыл бұрын

    the few Ive broken open had mineral oil in them, also some contain alcohol.

  • @TheRockeye007
    @TheRockeye0073 жыл бұрын

    the second one is for a heating and cooling window unit.

  • @Roy_Tellason
    @Roy_Tellason Жыл бұрын

    I've seen things of this sort also used to regulate the temperature of an oven...

  • @TheJunky228
    @TheJunky2283 жыл бұрын

    TIL! I guess I assumed they worked off of electronics like using a thermistor or something to that effect. This makes more sense for a low-cost thermostat, like in a mini-fridge

  • @eDoc2020

    @eDoc2020

    3 жыл бұрын

    I presume units with a digital temperature control use thermistors. I've only had 'old-fashioned' fridges with the temperature knob and you can hear these click even when unplugged. If you notice conventional refrigerators also have a motorized defrost timer. If the compressor is off but you hear a slight ticking coming from the thermostat area chances are it's defrosting.

  • @roygrafton6322
    @roygrafton63223 жыл бұрын

    I'm sitting here yelling "press the middle"! :-)

  • @johnsenchak1428
    @johnsenchak14283 жыл бұрын

    Could that liquid be mineral oil used in heat transfer in power transformers

  • @aaronbrandenburg2441
    @aaronbrandenburg24413 жыл бұрын

    That second thermostat I've seen something similar at least in design of the sensing tube/capillary tube. I'd call it more like a bulb or tube since it's both. Really a capillary per se because it's kind of bigger than that what would someone call that as well comments on that one might call it a sensing tube but that would imply just a tube going between something to be sensed and the sensor maybe? But anywho carrying on where I've seen these or something very similar probably not the same unit. I have seen something like this in a few different applications one of them was something similar but different Oh and by the way I think I remember what you would call that type of thermostat with that sensing tube as well. Again I'm still referring to the second one he took apart. I believe it's something or other linear sensing or something like that or linear sensing to something something linear. Pretty sure linear is usually in the name. Had to get apart like that once years and years ago. The time was something or other B.I. Before the internet! But the time at least the first time I changed out something like that it was a safety high limit switch that would have used the same type of sensing tube. It was in a electric baseboard heater. I also replaced a similar one in what look like one of those baseboard heaters except it was a portable electric heater. I've not seen one like that and years and years don't even know if they make them anymore. Also pretty much. The internals were the same as what would have been the fixed in place for a electric baseboard heater except with slight modifications mostly in caps it seemed which also had the legs for the heater as well. I suspect it was made by the same company and perhaps using the same parts? And yes these were a hundred twenty volt electric baseboard heaters as well. I do believe it was the same exact part that I replaced in both of them and I think it was somewhere between a year or so between those repair projects? This is something I had done for a friend. Daycare electric baseboard in just a few rooms where it would get chili since the HVAC was not up to Snuff! Also they used a window unit ac is the summer as well. Also fix to bathroom heaters in that same area the house as well possibly like a 2 or so years later. By the way in one of their neighbors places that I know had a weird system for electric heat with baseboard heating. The thermostats were three wire. But it was the same sort of system that would be used for hydronic Heat at least the thermostats except that there was a control unit in each electric baseboard heater. And each one was interconnected with the one before it. Where the thermostat wiring came in at the first one is for the first in the circuit for that room. The idea is that these were thermal relays essentially bimetallic strip and a heating element and a built-in Transformer as well. And when the thermostat was on it would apply power to the heating element on the bar metallic strip. Which would apply for an hour at some point to the heating element of the baseboard heaters it would be on for about 20 seconds at a time roughly. And then the other contact or one of them would trigger another one and so on and so forth. It was something rather troll something something he troll? Or something something. I've only run across this a few times or something similar. My guess was It was supposed to be more even heating or perhaps to reduce the maximum electrical load I don't know possibly both it's just weird and complicated as well as too complicated wiring as well. it took me just about forever to figure out what was going on and what the problem was because it was nothing like I've ever seen you previously that's the first time I dealt with that. But the idea with that long thermostat sensing tube is that it would it sends over a large area I can't think of too many applications for that other than say it like delinear safety control I was speaking about with baseboard instant water heaters. although one type of thing might be some sort of hidden camera that for something or where you're controlling the temperature not this early of an oven but you're keeping something at a constant temperature or warming cabinet or something like that

  • @MrRdmiller
    @MrRdmiller2 жыл бұрын

    Could you explain the extension spring at 20:08? I turned mine whilst trying to calibrate and I don’t know where it should be😮

  • @bren106
    @bren1063 жыл бұрын

    Quite a lot of domestic freezers have that bulb in the cabinet, so the mystery oil would have to be food safe. Your fingers aren't likely to rot off from exposure to it.

  • @danielmusat597
    @danielmusat597 Жыл бұрын

    Hi, As far as I know, the liquid inside the capillary tube is paraffin. Cheers!

  • @nathanwallace7072
    @nathanwallace7072 Жыл бұрын

    I cut one of those open once and the liquid bust into smoke and flames as it dripped on to my tile floor.🥰

Келесі