Hello my name is Chris and I will be posting videos about the cool stuff I see out in the field of HVACR. A little bit about my self, I've been involved in the trade for over 15 years and I will tell you right now that I do not know it all, this trade is constantly evolving and new technology is coming out every day. I am based out of Southern California and I mainly work in restaurants. If you have any questions or even suggestions for videos please don't hesitate to email me at [email protected].

To support my channel please visit Patreon at www.patreon.com/Hvacrvideos


For Optimizing my videos I use Tube Buddy
www.tubebuddy.com/HVACRVIDEOS

THE WALK IN WONT GET COLD

THE WALK IN WONT GET COLD

I LIKE WORKING ON EXHAUST FANS

I LIKE WORKING ON EXHAUST FANS

THE FAMILY DINNER HAD TO WAIT

THE FAMILY DINNER HAD TO WAIT

EXHAUST FAN PROBLEMS

EXHAUST FAN PROBLEMS

THE BEER WALK IN IS TOO WARM

THE BEER WALK IN IS TOO WARM

I DID EVERYTHING I COULD

I DID EVERYTHING I COULD

Пікірлер

  • @jaymesrod4209
    @jaymesrod420913 сағат бұрын

    Chris, im gonna shave my beard so I can look like im 18 and then apply! Wish I could have apprenticed under you

  • @sirblake3
    @sirblake314 сағат бұрын

    I hate dealing with ems

  • @coreyr8870
    @coreyr887016 сағат бұрын

    About the conversion to 407c. Thought that was the solution for r22 systems that people dont want to replace, but doesn't work qith fixed orifice vs changing txvs?

  • @necessities-1235
    @necessities-123517 сағат бұрын

    How to casually shit on your coworkers schrader removal tool.

  • @0Tweaky0
    @0Tweaky021 сағат бұрын

    To protect the solenoid Valve and head pressure control valve from getting hot when braising, you could bolt them on like the liquid line dryer and then no more Wet rag.

  • @peterhall8051
    @peterhall8051Күн бұрын

    Socket Wrench ASMR

  • @derrickharney6750
    @derrickharney6750Күн бұрын

    where are you at in the desert with all that sand

  • @dyl4446
    @dyl4446Күн бұрын

    do more ac vids

  • @HVACRVIDEOS
    @HVACRVIDEOS20 сағат бұрын

    I will do that

  • @glenjones4404
    @glenjones44042 күн бұрын

    I think all refrigeration condensing units should anti short cycle timer put in when the system is on a pump down and auto reset head pressure switches 💯

  • @mysticknight9711
    @mysticknight97112 күн бұрын

    Having Y1 & Y2 jumpered can totally explain why the original fuses were blowing - both compressors starting at the same time is a huge inrush current and the circuit was never sized for concurrent startup on those motors

  • @mysticknight9711
    @mysticknight97112 күн бұрын

    Instead of longer “chase nipples” how about using a regular threaded rigid conduit nipple and placing a nut and a plastic bushing on both ends.

  • @EGCMomentslater
    @EGCMomentslater2 күн бұрын

    Loving the return to the old intro 😊

  • @KingSchmandmann
    @KingSchmandmann2 күн бұрын

    Here in germany the law! says, you have to usw for non solid copper wire these 'nuts' (google says: "wire nuts" -lol ) (you have to crimp on ) - cable shoes?

  • @kathyfoss3832
    @kathyfoss38322 күн бұрын

    At 4:40 - Like a good neighbor HVACR is there!

  • @wurthmannd024
    @wurthmannd0242 күн бұрын

    TXV's with the flare fittings like some line dryers have would be too good to be true, especially for scenarios like this

  • @dannygonzalez5844
    @dannygonzalez58442 күн бұрын

    I didn't see if you test the fan motor amp if this consuming more amp or running low , maybe the speed of those fan can be changed , i think the Air flow issue is because the fan motor is was running low like a have to be .., the package was Cooling properly before so why to blame the duct ??

  • @nathang.1744
    @nathang.17442 күн бұрын

    Have any of you ever worked on digital compressors? Do you guys think they are a good concept?

  • @mattmorisseau8392
    @mattmorisseau83922 күн бұрын

    Man's living in 2025

  • @gumaroalcocer9923
    @gumaroalcocer99233 күн бұрын

    I not expert but I’m handyman some times I recibe a Coll s from local restaurants I have fix many tings to them I did change a motor on. One exhaust fan on the kitchen but I have tink that I under charge for all I do Like you said they Coll on emergency so I like to know how moch to charge I did all you just did there check for any problems on wires or sensors or bad contacts took me like 5 hrs to do it because it the shaft on the motor was very stock and it was 100 degree temperature on the roof So can you give me one idea of charging. Price on hrs Im in Texas I will very tankful

  • @gumaroalcocer9923
    @gumaroalcocer99233 күн бұрын

    I di like your videos they made perfect and clear awesome 👍

  • @wurthmannd024
    @wurthmannd0243 күн бұрын

    Lennox units always give me crazy problems 😅

  • @REC379
    @REC3793 күн бұрын

    Someday your channel is going to have millions of subscribers! Keep doing what your doing and your going to get there. You are my #1 favorite channel to watch and you are amazing!

  • @HVACRVIDEOS
    @HVACRVIDEOS3 күн бұрын

    Thanks for the nice words

  • @AngelHVACR
    @AngelHVACR3 күн бұрын

    What kind of hose do you use to de ice those coils , also do you use an adaptar for kitchen sinks ?

  • @HVACRVIDEOS
    @HVACRVIDEOS2 күн бұрын

    I'm going to discuss this a bit further on my live stream this coming Monday

  • @zekenzy6486
    @zekenzy64863 күн бұрын

    Great video. Thank you for sharing

  • @HVACRVIDEOS
    @HVACRVIDEOS2 күн бұрын

    Thanks for watching

  • @ebuzek3648
    @ebuzek36483 күн бұрын

    you could have relocated the valve just outside the evaporator and made it easier to work with.

  • @ed6837
    @ed68373 күн бұрын

    The fan blade with the set screw that wouldn't tighten. Could abandon the set screw and drill and tap a new hole new set screw. Probably a 1/4 20 tap and a37 drill bit. But you got it thats what counts

  • @oldtimefarmboy617
    @oldtimefarmboy6173 күн бұрын

    A little bit of never-seize on the set screw and the shaft will prevent them from rusting and make removal in the future far far easier.

  • @HVACRVIDEOS
    @HVACRVIDEOS2 күн бұрын

    Good tip, thanks

  • @damianorsini6468
    @damianorsini64683 күн бұрын

    @ 2:44 Ahhh Chris, my dude, you forgot to thaw out a little “ice” on that beard bud. Lol😅 😂 Big picture diagnoses might include some Just For Men aka soy sauce on the old face fuzz. I tease bud, I tease…. Thanks for all the great vids

  • @Portuguese-linguica
    @Portuguese-linguica3 күн бұрын

    Question. I have a Goodman 2.5 Ton, 13.4 SEER2 Self-Contained Packaged Air Conditioner . If i use the ac portion to cool the house ( 1,450 square feet ) and then dont use for a day or two . It snells horrible when i use it again. It smells like rotten fish . Any idea what causes this ?

  • @glenjones4404
    @glenjones44043 күн бұрын

    Yeah the compressor had been in the wars that scroll looked well cooked looking at the black paint work it was like a matt finish instead of a nice shiny finish 🥵

  • @glenjones4404
    @glenjones44043 күн бұрын

    It didn't pick up trough the contactor because u had system off which you would then press the contactor manually to know you had a down control fault on that compressor I think chris

  • @glenjones4404
    @glenjones44043 күн бұрын

    It should really be a no brainier changing all contactors I agree 💯

  • @markae0
    @markae03 күн бұрын

    Too much ice behind the fans and the manager can't figure it out? That companies going down if the manager is in charge.

  • @MrPhantomPC
    @MrPhantomPC3 күн бұрын

    Wow. I worked at a certain red head’s and had similar where dudes climbed the outside of the building on top of roof and stole copper everywhere visible and even the exhaust fans they tore off and I guess scrapped. Crazy how they’d probably get paid more if they rough demo’d as a job lol. Like the amount of work put in to… what couple hundred max?

  • @warialinth
    @warialinth4 күн бұрын

    Seeing wirenuts everywhere makes me hope that your costumer won't burn down.

  • @user-vf7qq3ie8q
    @user-vf7qq3ie8q4 күн бұрын

    How does a dishwasher even have an exhaust I'm confused

  • @spacemanwithraygun3933
    @spacemanwithraygun39334 күн бұрын

    Those caps pop when the valve is bad. Sometimes working the valve down then back open with a new cap will fix it.

  • @freefunky830
    @freefunky8304 күн бұрын

    Yummmmmmmm

  • 4 күн бұрын

    All that oil is from no oil return trap problem.😵

  • @addilovsmattyb
    @addilovsmattyb4 күн бұрын

    Next thing I know which motor is the working. The one that has ice on it

  • @skunkworks9-3
    @skunkworks9-34 күн бұрын

    I know pigeons are the "rats" of the sky but they're here and so close because of our ancestors. They used them for messaging and they used to be real close to us like dogs. Once Morse code and the telegram settled in we threw pigeons to the curb and they've been here like this since. It's a funky situation but even Nikola Tesla felt bad and took care of some there at the end of his life.

  • @alantorrance6153
    @alantorrance61534 күн бұрын

    That roof needs cleaning -- urgently. There is widespread rubbish.