MULTIPLE YORK PACKAGE UNIT'S NOT COOLING
The complaint was that they had an ac not working but while on the roof I found another one that was down too.
HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com
Please consider supporting my channel by
Becoming a Patreon member - Patreon / hvacrvideos
Becoming a KZread channel member / @hvacrvideos
By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
Visiting my website and purchasing merch www.hvacrvideos.com
HVAC OVERTIME CHANNEL LINK - / hvacovertime
Social Media
Facebook / hvacr-videos
Instagram / hvacrvideos
For any inquiries please contact me at chris@hvacrvideos.com
Mailing Address
HVACR VIDEOS
12523 LIMONITE AVE.
440 - 184
MIRA LOMA, CA. 91752
Пікірлер: 148
"no wonder that one's missing, it's in my hand. Duh" Holy moly I feel that one 😂
Those units have definitely lived their life, and they’re still working decently well considering how old they are. They sure don’t build things of the same quality that they once did. Thank you for another awesome video Chris! I’m learning more and more from you with every new video I watch. Keep up the great work! 👍🏻👍🏻👍🏻
@dotcom624
2 ай бұрын
Maybe I wasn’t paying attention, but I don’t remember hearing about PMs by this company on these units. From the looks of it, they must do at least some PM to keep old units working as well as they do. Might not be as efficient, but as others have mentioned, they don’t make them like they used to! Know what I mean, Vern?
@HVACRVIDEOS
2 ай бұрын
@@dotcom624 I know exactly what you mean
This old piece of junk is still working better than the new pieces of junk one third of its age...
@Extremely_crazy_toaster_light
2 ай бұрын
i had a old Philips 55 inch tv it could survive a fast plushie to the screen no matter what!
you know, sometimes the engineer part of my brain thinks i could make an absolutely ballin refridgeration unit and then i see these absolute tanks that are still happily running and i get humbled. great work as always!
@HVACRVIDEOS
2 ай бұрын
Thanks
Welcome to Ontario Weather... Here you need a T-Shirt, Fall Jacket, Snowsuit and Umbrella all in the same day... We have a saying: If you don't like the Weather...Wait 5 minutes... 😄😁😆😅😂🤣
Those units absolutely suck to replace the heat exchanger...if you haven't replaced one...count yourself lucky. They are simple units in form and function...probably why it's lasted so long. Very nicely done as always Chris.
@johnhaller5851
2 ай бұрын
He said at the end that most of the units have had the heat exchanger replaced and that it was a nightmare to get all the parts.
@TheGhettoLobster
2 ай бұрын
As someone who deals with mostly York in their area, yes, these sunline yorks suck BALLS to replace the heat exchanger.
Calling that unit old is an understatement, it is very rusted. Suggesting it was either a cheaper model, or perhaps 80s. Either way, I'm unsure. However, I agree with the rest of the comments, this thing has lived its life and done well.
@HappilyHomicidalHooligan
2 ай бұрын
He said at the beginning it's from the 90's... So it's 30+ years old and still working...sort of...
@VannBergHVAC
2 ай бұрын
Bristol compressors with metal tags instead of stickers. 1994 at the latest.
Preventative Maintenance is always Money well spent but those Paying your Bill don’t look at it the same way. Keep up the Strong 💪 Efforts servicing customers.👍
Lock tight is great for vibration issues. Things don't tend to vibrate off when they are secured with Lock tight.
@HVACRVIDEOS
2 ай бұрын
True
If you can't get any Electrical Conduit that will fit the space, try a piece of PEX water pipe...the 1/2" PEX pipe is big enough to take a single length of 14/2 ROMEX house wire so the individual wires for one of your Fan Motors will fit with room to spare with little to no chance of overheating the wires...that will keep the wires away from the blades as well as protect them from rubbing out on the fan grill...
A trick i do to remove really stuck fan blades off bad motors is cut the shaft and drill out the shaft, never couldn't get one off doing that hardest part is drilling the hole dead center of the shaft.
Was hoping I'd see one of these units in one of your videos. I have 2 of them on my building and it was built in the late 80s so I'm pretty sure they're original since we've been here since 94 and we've never replaced them. One of them finally needs to be replaced but the other unit works like a champ. I have a Rheem and Trane on another building, those are about 10 years old and have needed more work this this unit has since 94.
I have 3 Yorks units on a building I work at . Plus I keep the fully cleaned, oiled, belts , coils cleaned, I also buy new replacement parts . I also listen to the units for any problems. I love your KZread channel I learned many things, on the different units you repair, Thanks
York made good units and they seem to have stood the test of time. I think Ford used York compressors in their cars many years ago and I heard they could be rebuilt.
When using generic fan motors I like to use a piece of 3/4 pvc to run the wires through if there is no existing conduit. I normally fasten the pvc to the guard with zip ties, but even when those break off the pvc holds itself in place. Those plastic insulators around the reversing wire terminals have a habit of cracking off in the sun and shorting out, especially on roofs with no tree cover.
You're saying about the high subcool (always with the discharge), but I see the same on my 2-3 ton condensers, too. I'm used to seeing 20 to 30 degrees of subcool........but that's when I'm hitting the 100 to 105 ODT range. The condensers are from 2005 and 10 SEER. Eh? Fuck it. If it rejects heat, it rejects heat.
@garypoplin4599
Ай бұрын
“Liked” comment, except for the SMUT.
I’ve worked on one of these before for PM work and on my last visit, on the blower wheel shaft, i spied grease zerts🧐. Never saw them before or was shown it has them.. just a quick eye out for the next one you come across
Those older units really out live the new units. Some the new units come flat or don’t even last a year before something major happens.
Another awesome video man! Thank you for sharing!
Great video. Thank you for sharing. Have a nice weekend
Am I wrong or did you start a more step by step process approach on your videos. I'm loving it!
Good video Chris. Most customers are usually happy with JUST getting it fixed. Like an old car, as long as it starts and runs, they don’t care about economy, emissions or whether it has satnav, as long as it gets them from a to b. Them old units still blowing cold ish air? Jobs a good one. All the best.
love your videos man, keep up the good work!
Just putting this out there for anyone starting in the business... Just because you turn off the disconnect switch DOES NOT MEAN you don't have power going to the unit. In my very green days, I turned off the disconnect thinking I was safe to work on the unit, but heard my schooling in my ear about "always check for power". I checked inside the unit just before I put my hands in there and had 460v. This was because the monkeys that were there before me straight bypassed the disconnect inside the disconnect switch. To say I was upset doesn't come near what I was feeling in that moment. Always check for power.
I agree with you, those old Yorks aren't going to last too many more California summers. You bought them some time, but replacement is inevitable. Full refurbishment, when factoring in parts and labor (assuming you can find all the parts) would probably be close to replacement cost. The phrase "diminishing returns" once again rears its ugly head... I fully expect you to experience more "Band-Aid Solutions" in the future. Cali's new $20 minimum wage for fast food workers will have such a financial impact to restaurants' operating costs that your clients will HAVE to cut corners to stay solvent. Sadly, this also means an increased potential of having to troubleshoot and/or repair work done by untrained/unlicensed individuals ("I know a guy that could fix that for ya much cheaper!").
Yeah this time of year is tricky.. need an extra chiller during the day here.
Great video! I work on a lot of those same York units.
@HVACRVIDEOS
2 ай бұрын
Thanks
Thanks for the sunday drops. Its my Monday and it makes work sooooo much better.
@HVACRVIDEOS
2 ай бұрын
Thanks for watching
Great job Chris old units are good for business especially when customer want change them out. You know you will be working on them. it is what it is. lol
I use electrical conduit to protect the wires then zip tie it to the shroud.
Once you replace the units sell them and label them as true vintage hvac equipment and people will instantly buy these because they like buying and keeping or restoring old things
Corporations frequently have policies that require doing the same thing over and over again which in the long run costs more. There should be a spread sheet where it determines the time to replace rather then fix. Every motor or compressor has a mean time before failure. As you get close to that MTBF you schedule a replacement it should be on a calendar. This failed approach to management looses money.
loving that intro music
Shocked it wasn't due to low charge, that unit is beat to all hell but god damn it just wont quit
The man the legend
Another great job Chris
@HVACRVIDEOS
2 ай бұрын
Thanks
It's crazy how slow they look on video. Also it always looks like it runs backwards on video. Probably because some cameras run mirrored while others look normal.
You've got to give these old units some credit, by the visible condition they're real old and there obviously hasn't been a load of major, new parts fitted.
Yea the electrical section is usually about 5 to 6 inches at the most.
Boy, this brings back memories... The McDonald's I was a maintenance man at had these York units & every week I'd pull & clean the air filters (They had the type of air filters that were washable -- Just spray 'em down with degreasing solution, rinse 'em out, let 'em dry then put them back in) and clean the condenser coils. Every year we did PM on them where we'd take 'em apart, clean them out thoroughly & put them back together. If anything malfunctioned, we called in a local HVACR tech to fix it.
It's all about giving the customer the information so they can make an informed decision. And I hate that model of York. They've lived a great life time to go lol
Y1 Wy isn't it cooling 👌 great words 👏
High superheat, high subcooling. I guess low mass flow through the metering device. High load with only moderate outdoor temp, plus some restriction.
I want the old intro back please 👉🏻👈🏻😌
The intro music is from this music video. ELFL - Zero Gravity
Jaw-dropping!!, you didn't reclaim and weigh in the charge. You're slacking!!
@HVACRVIDEOS
2 ай бұрын
lol, Ill do it twice on the next one to make up for it
I hate the design of York equipment I find its difficult to work on for no reason especially their electrical sections , the newer large units have a much larger electrical section but the smaller ones (10t or less) are still brutal
You could actually use 1/2 inch electrical seal tite to replace the wire conduit going to the motor it is the same thing
Sadly most of the units I work on looks like those. We just have to bandaid them and move on. Very rarely will the customers accept our recommendations.
Thank you very much for the amazing videos. I love to watch them. Your channel is like a criminal TV show, and I always want to know "who" the "killer" is. I have one question about capacitors for condenser motors. Seeing that this is a 3 phase unit, it wouldn't be better for the manufacturer to connect the motor as 3 phase. Then you will not need the capacitor. Also considering that the capacitor is next to the contactor, you don't save any cost on wires. Even with a capacitor it looks to me like it's more expensive. Radek PS: I know only 3 phase systems in Europe, don't know if it's similar in the US. 3 legs, each shifter by 120°.
@HVACRVIDEOS
2 ай бұрын
Thats a good question, Ill see If I cant talk about that on my next live stream
@ThunderClawShocktrix
2 ай бұрын
I think it was jsut so the OEMS couls stock fewer motors using the smae ones for both singe phase home ACs and commeircal 3phase units and yes its dumb
I'm buying that bag!
thanks for the code i needed some new veto's. $40 savings vs veto's website
@HVACRVIDEOS
2 ай бұрын
Money well spent
I'll use a piece of 1/2 or 3/4 pvc for conduit on those Condenser Fan Motor electrical connections where you can't find it from the dealer. Raintight works good too.
@HVACRVIDEOS
2 ай бұрын
Great idea
Chris, I noticed that the return air temperature was very low on the first unit that you checked vitals on. The condenser approach was also at 0. Is it possible that the unit was just underperforming due to the cold conditions it was running in? I believe that if you had a higher load both indoor and outdoor, we might see better performance. For the second unit, I believe it looked better because the outside air temp had risen to 70.
I like to use a small piece of liquid tight zip tied to the fan guard for the wires
Apart from being old, what was wrong with the units? You mentioned a few times it was junk (definitely looks it!) but what's actually wrong with it as it seems to be working? I'm not in this field so just curious to learn and have been loving your videos for ages now. Thank you!
120 nice and warm 🥵 uk so anything above 80 and i start to melt.😃
Hey Chris, I had a question. I’m about to swap a 15 ton package unit in a roof and I have never done it. Would it be possible to make a video describing what all goes into it? 👍👍
Maybe the customer hopes the contactors kill a compressor so they can convince corporate to buy replacements 😉
The pistons like to plug up on those units
i mean if the unit is not discharging the heat at the condenser you wouldnt have a sub cooling not to high of a subcool so probably a restriction
I see they added "stable volume" to video playback options. hopefully no more doing backflips over the chair when watching? 🤣 not so much here, but some across "the tube" have very extreme volume changes from quiet to blown out audio loud. lol
@garypoplin4599
Ай бұрын
Thanks for that ‘tube trick. I hadn’t noticed it before your comment. Much appreciated. I agree: some vids have extreme amplitude swings! Not so much Chris’ posts. The only swings in his is pitch when he needs to talk over ambient noise of running units. No noticeable volume changes.
You know what you could of done is the dead motor capacitor how 10uf and it good and replace the good motor but bad capacitor.
What about the cooler you have in the van, is that also on TrueTechTools? Yeti, I think you said anyway, what's your review? Awesome videos!!
Question on the other unit that you replaced the entire unit. Roughly how much total time was that job to swap out the entire unit with the crane?
I hate dealing with ems
If we could build equipment to last 30 years in the 1990s, todays stuff should last double that. Sadly the trend is opposite. Too many people have blinders on now, and replace working units all because of the green new scam. Great repairs Chris.. ❄️
how is the condensor fan motor suppose to run with no cap hooked up?
Hey Chris , I thought R to Y1 should be 0v as t-stat switch is closed , Y1 To C(x) should have 24v…or is that just with residential , I’m not familiar with commercial, thanks a lot man.
What iPad holder do you use, is it magnetic so you can stick it to the RTU? Also, ugh sometimes I think we are actually professional turd polishers, not technicians.
Hey there Chris! Keep up the good work! I wanted to ask why you still use your smartphone to film? Why are you not using a GoPro(or another brand) with a belt from which you can film from you chest? Would be easier to work for you since you would have both hands free. Just a suggestion, dont get me wrong. 😄
At some point all you're saving is the sheet metal because everything inside them needs to be replaced ... no real benefit to keep the old units going, unless maybe the new units have poor quality but I don't think that's the case.
Just to let you know, I hate remote EMS controls. No local control.
Add a little gas. Pressure a little low
@hackendan1921
2 ай бұрын
Already has high subcooling. Liquid building up in the condenser.
go pro with a band, it can go over a hat for hands free work
EMS System Energy Management System System A bit of RAS Syndrome 🤣
What's the name of the song in the beginning I like it
You polish her well chris
@HVACRVIDEOS
2 ай бұрын
Thanks bud
The real problem is York
@mangoisback
2 ай бұрын
Yeah and their tech support, you gotta go through loopholes to get a representative
Those units are going to be late 1990s....like 97 or 98. Do you have a serial number?
They would be better off fixing those if the parts were built the same.
I noticed on that first unit you had a 61 degree liquid line . Wonder if you had a restricted drier
@dipley3771
2 ай бұрын
Good video nonetheless, I’m ready for the season
Do you charge the customer travel time? Is there a distance where overtime is cheaper than a second trip charge? I know it gets hard to work overtime, and on the hottest days, nearly impossible. Or is it just some customer policies that they won't pay for overtime?
@HVACRVIDEOS
2 ай бұрын
Ill see if I cant elaborate on that during my next live stream this coming Monday
Yummmm
" Polishing a Turd" is a term you use with your clients or just with your fan base?
@HVACRVIDEOS
2 ай бұрын
Just on the videos, the customers hear a more professional description
Mojave motors like MacOS Mojave
What app is that that he uses when he gauges up?
@HVACRVIDEOS
28 күн бұрын
The app is called MeasureQuick
why dose the spare belt not fly up into the blower? 13:49
@HVACRVIDEOS
2 ай бұрын
The suction is not nearly that strong
@Funthingstowatch
2 ай бұрын
@@HVACRVIDEOS thank you so much I watch your vids every time you uploade
Could have been a great trailer from 17:47 to 17:57
UNIT'S = UNIT IS.
Grab a scrap of sealtight for those wires next time and can tuck the reversing wires inside too
@HVACRVIDEOS
2 ай бұрын
That’s a good idea thanks Joe!
@joeshearer1247
2 ай бұрын
@@HVACRVIDEOS yea man and harbor freight has some decent stainless zip ties if you want to get some
If there is no conduit left, I pull the condenser fan leads through 1/2" liquid tight and call it a day.
Do not take in a negative way just commenting fore engagement and question. Started your video 5 minutes in I am thinking just replace all 4 fans before spending time to figure out what is wrong with them. Cheaper to replace cheap parts than spend the time figuring out why a rusty fan motor is not working properly.
@drewc7479
2 ай бұрын
Lol is that a serious comment? Replace all the fan motors rather than get your customer cooling from a possible bad capacitor? Could be bad fan cycling etc . Most techs are like what you commented , and it keeps guys like us so busy
@jonleiend1381
2 ай бұрын
@@drewc7479 From what I saw in the video it took him about 30 seconds to figure out that the one with a quarter inch of play was bad. So he is already going to have to make a trip to the supply house and get new motors. Already going to have his tools out. If all 4 motors are about the same age why turn it in to 4 separate calls to replace one motor at a time. I am not the expert but if the capacitor goes bad it is a good indication that the motor is going bad also.
@jonleiend1381
2 ай бұрын
Before you reply that the supply house did not have 4 motors I did hear that and would have made his job easer if they had what he needed.
@drewc7479
2 ай бұрын
@@jonleiend1381 I've changed many capacitors in the past and never went back to replace the fan motor. I can see your point , but sometimes to a customer that doesn't seem logical and they just need what's not working to be fixed
@johnhaller5851
2 ай бұрын
You must have clicked out before the end of the video. The customer doesn't want to pay for the extra motors. He just follows the customer direction.
The main issue here is that you’re working on York brand equipment. I’ve always thought York was straight trash and a waste of money for anyone to purchase.
What’s the name of the song on your new intro?
@HVACRVIDEOS
2 ай бұрын
Shoot me an email to remind me to look up the song name for you HVACRVIDEOS@GMAIL.COM
if a york unit was a food it is a *broken egg York*
To walk the road my forefathers walked.
This intro just ain’t doing it for me😭
@Floofie_boi
Ай бұрын
I like it
This unit might be using R12.
@ryanisaacson118
2 ай бұрын
No its not that old of unit this is 90s 2000 unit most likely a 22 unit
79 thumbs uP