Replacing the Fan Speed Control Switch in a Downdraft Vent

Тәжірибелік нұсқаулар және стиль

This video from Sears PartsDirect shows how to replace the fan speed control switch in a downdraft vent. The speed control switch is located on the upper right side of the air vent. It activates the fan motor and controls the blower speed, allowing you to change how fast or slow the fan is blowing. If your control switch won’t change the fan speed anymore, replace it using the steps in this video.
Visit us at:
www.searspartsdirect.com?sid=soc:youtube:replacing-the-fan-speed-control-switch-in-a-downdraft-vent
Or call 1-800-437-1673 to speak with a parts specialist.
The video includes these parts and tools. Look up your model to make sure you get the right parts for your vent.
Fan Speed Control Switch
www.searspartsdirect.com/part...
Find parts for your vent at:
www.searspartsdirect.com/part...
Transcript:
The speed control switch is located on the upper right side of the air vent. It activates the fan motor and controls the blower speed. If the speed control switch stops working, replace it using the steps in this video. Wear work gloves to protect your hands. Unplug the cooktop and the downdraft vent. Remove the cooktop from the counter. Remove the downdraft vent from the counter and lay it down on a padded work surface. With the power disconnected, remove the mounting nuts from the clamp channels and pull the channels off. Remove the screws from the gear motor cover. Disconnect the motor wires and then pull the cover off. Carefully tilt the top of the blower housing up and disconnect the blower motor wire harness. Remove the blower housing assembly. Remove the mounting screws from the air box cover and pull it off. Unplug the wire harness for the speed control switch. Cut the wire tie that secures the speed control switch wire harness to the green ground wire. Pull the air vent out to access the speed control switch. Remove the mounting screws and pull the switch cover off. Remove the screws from the switch bracket. Slide the switch bracket down and then pull the bracket out. Pull the knob off the speed control switch stem. Remove the mounting nut. Pull the speed control switch out of the switch bracket. Disconnect the activating switch wires. Cut off the wire tie from the switch bracket to release the wires. Remove the speed control switch. Secure the new speed control and activating switch wires to the switch bracket using a wire tie. Connect the activating switch wires. Reinstall the speed switch on the switch bracket and secure it using the mounting nut. Reinstall the knob on the stem of the speed control switch. Slide the switch bracket into the vent. Adjust the switch bracket so that the activation switch lightly touches the membrane pad. Tighten the bracket screws firmly. Tip: Mounting the switch bracket up too high will keep the switch depressed and the vent will raise and lower continuously when power is restored. Reinstall the switch cover and secure it using the mounting screws. Push the air vent back into the air box. Plug in the speed control switch wire harness. Connect it to the green ground wire with a wire tie. Position the cover over the air box and thread the gear motor wires through the grommet. Reinstall the mounting screws. Put the blower housing assembly in position. Plug in the blower motor wire harness. Lower the blower motor housing assembly into place. Thread the wires through the gear motor cover and reconnect them. Put the gear motor cover in position and reinstall the screws. Reinstall the clamp channels and secure them with the nuts. Reinstall the downdraft vent and cooktop in the counter and reconnect power.

Пікірлер: 2

  • @johnapplianceguy9317
    @johnapplianceguy93175 жыл бұрын

    It's usually installed in countertop behind a cooktop. Laying it on a flat service is pretty much out of the question. Show us how you get inside the cabinet below it working on your knees and elbows and then diagnose and fix it.

  • @searspartsdirect

    @searspartsdirect

    5 жыл бұрын

    You can shut off electrical power and complete the repair as shown in the video without removing the downdraft vent from the counter if the cooktop doesn't prevent you from accessing downdraft vent components. You may need special tools to access fasteners if you don't pull the downdraft vent out of the counter. For many downdraft blowers installed behind cooktops, it's difficult or impossible to safely access the vent fan control switch without pulling the downdraft vent out of the counter so we show the repair with the downdraft vent on a flat surface. If you need to remove the downdraft vent from the counter to complete the repair, you can use the installation instructions for your model as a guide for removing and reinstalling the downdraft vent. Here's a link to the installation manual for the downdraft vent shown in our video: www.searspartsdirect.com/partsdirect/user-manuals/273003-broan-parts-manual . We hope this information helps. If you need further assistance, let us know.