In this episode of Artisan Electrics, Jordan takes you on a deep dive into how we install electric vehicle chargers. This install includes a channel first appearance from The Indra Smart Pro! Smart by name. Smart by nature, and possibly the smartest charger currently on the market? Stay tuned to find out what makes this charger so smart!
🌐Find out more about INDRA here - bit.ly/33sQwrW-INDRA
Make sure to check INDRA out on all social platforms - linktr.ee/IndraRenewableTechn...
INDRA Smart Pro - Product Description
The Smart PRO is the smartest electric vehicle charger available on the market. Chock-full of the latest smart features, this innovative EV charger brings you cheaper, faster and more advanced home charging. The British-made Smart PRO EV charger enables you to take advantage of the lowest-cost electricity from your supplier and free power from your rooftop solar without having to buy an add-on kit.
Subscribe to our KZread Channel for more great electrical content: kzread.info...
Get more from Artisan Electrics here!👇
linktr.ee/artisanelectrics
⏱️Timestamps
00:00 Is this the smartest EV Charger
00:15 Welcome to the episode
00:42 Meeting the customer
01:00 Plan for the install
01:30 Consumer Unit
03:54 Main cut out fuse
06:19 Gas Pipe
07:13 INDRA Charger unboxing
09:25 Lining up the drill
10:43 Angle Drilling
11:33 EV Ultra Cable
12:40 EV height regulations
13:27 Mounting the bracket
14:31 Rawl plug hunt
16:09 Mounting the charger
17:48 Clipping the cable
18:45 Doughnut time
19:17 Cable stripping tools
19:38 Wiring up the charger
22:09 Wiring the consumer unit
23:50 R1 & R2 Testing
24:59 Double check
25:25 Charger Internet Connection
26:57 Putting the cover on
27:27 Sorting the tails
28:42 Checking connections
29:11 Data cable
31:09 WiFi Pairing
31:22 Charger commissioning
33:31 Charger B-Roll
33:58 We’re all set up
34:23 INDRA Smart features
35:53 Find out more
🧰🛠️ Tool Of The Day 👇
Klein Tools Pass-Thru Modular Wire Crimper - amzn.to/3HV22eJ
🔦Unilite Work Lights:
Get 25% off all Unilite Products using our code "ARTISAN25"
UK Store - bit.ly/UNILITE
Europe Store - bit.ly/UNILITE-EU
USA Store - bit.ly/UNILITE-NA
Australia Store - bit.ly/UNILITE-AUS
🏷️😱 Big Boots - get 5% off our amazing work boots when you use our discount code "ARTISAN" at checkout here bit.ly/BIGBOOTS
🎵 Use music the Artisan Way - Sign up to Epicmedic Sound here 👇🏼
www.epidemicsound.com/referra...
🔔 Become a Channel Member To Get Access To Exclusive Perks 👇
➤ / @artisanelectrics
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
-----Electricians Business Course-----
📩 Sign Up To My Electricians Business Course Here And Get The First 4 Lessons Free 👇
➤ bit.ly/2Z582zI
🔔 Subscribe to TOOLS4SPARKS KZread Channel 👇
I Also Have A Dedicated KZread Channel About Tools:
➤ / tools4sparks
-----MY ENERGY PROVIDER-----
🐙 Get £50 credit when you switch to Octopus Energy 👇
➤ share.octopus.energy/zappy-sh...
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB?tag=ar...
📈Make the most of your KZread analytics with TubeBuddy - Sign up here👇
➤www.tubebuddy.com/ARTISAN
-----TRADES INSURANCE DISCOUNT-----
If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote
📞 or call 01162437904.
📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
⏰ Artisan Electrics TikTok Account
➤ / artisanelectrics
💼 Artisan Electrics Linkedin
➤ / artisan-electrics
🎥 Get in touch with the Media Team
➤media@artisanelectrics.co.uk
This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
#sparkylife #electricianlife #artisanelectrics

Пікірлер: 343

  • @artisanelectrics
    @artisanelectrics2 жыл бұрын

    Let us know your thoughts on the Indra Smart Pro Charger. Make sure you’re subscribed to our Channel with Notifications on - bit.ly/3nqFpXp-ArtisanElectrics

  • @aaaa-ig6sc

    @aaaa-ig6sc

    2 жыл бұрын

    I've had mine for three months and can't fault it. The app is fairly decent, clear billing section and easy to use. It also supports Octopus Go and Agile to charge when it's the cheapest slots. Rumor has it SoC is coming soon, rather than just idle/boosting etc.

  • @aaaa-ig6sc

    @aaaa-ig6sc

    2 жыл бұрын

    Can you do a video based on Indra's V2G/V2H charger, uses Chademo bidirectional to send it back into the house or grid. CCS soon 🤞

  • @gap9992

    @gap9992

    2 жыл бұрын

    Can it be set up to vary charging to avoid sending my spare solar back to the grid ?

  • @gadgetman36

    @gadgetman36

    2 жыл бұрын

    I much prefer the look of the Andersen, Indra and Zappi to the Hypervolt, which looks so untidy with its separate holster and extra 4 holes that need to be drilled for it. I can’t believe the awful Rolec Wallpods like Jordan ripped out are still being fitted, but they are on a new build housing estate near me.

  • @aaaa-ig6sc

    @aaaa-ig6sc

    2 жыл бұрын

    @@gadgetman36 I think Anderson wins on style, I would take the Hypervolt over Indra Smart Pro even with the separate holster. The Zappi literally looks like a toilet seat but is a decent EVSE (just need to order in black 😜)

  • @GeordieDashCam
    @GeordieDashCam2 жыл бұрын

    Hmmm, one point. personally if I want something screwed securely into a wall I'd never ever go into the mortar, fixing into the brick invariably gives a 'more' spherical hole which enables the rawl plug to grip correctly. After 50 years of many different fixings I can well remember the blocks of wood hammered in to a gouged out mortar line, as the mortar degrades fixings become loose .... in brick they stay fixed.

  • @biaelectric9066

    @biaelectric9066

    2 жыл бұрын

    Still calling them Rawl Plugs, eh? If you were on the Fischer Duos you wouldn’t be so worried where you placed them!

  • @heladas90

    @heladas90

    2 жыл бұрын

    I'm all about using the wall dog screws when mounting EV chargerd

  • @GeordieDashCam

    @GeordieDashCam

    2 жыл бұрын

    @@biaelectric9066 Hi there, yup, still calling them 'rawl' plugs, more as a generic term and it's what Jordan referred to them as. I've never tried 'Fischer Duos' and I'm sure they are admirable but checking their website pictures they don't actually show any of them going in the mortar line. I was merely making the point that in my opinion, any fixing is much more secure in brick than mortar, it's 15 years since I retired but I doubt mortar has improved. Having said all that, an EV charger probably has a limited lifespan and will no doubt be replaced long before the mortar crumbles. (I was never worried where I placed my fixings as they always went into brick) :-)

  • @tombarrett1487

    @tombarrett1487

    2 жыл бұрын

    @@GeordieDashCam actually, although I agree with your comment regarding drilling the brick and not the mortar line, the plugs Jordan used are made by Rawlplug, so in this case it was the correct nomenclature.

  • @rogerbean393

    @rogerbean393

    2 жыл бұрын

    It’s the awesome drilling crew again , always in the mortar!!!! He will never learn.

  • @essexcountyelectricalltd
    @essexcountyelectricalltd2 жыл бұрын

    This chargepoint is a hell of alot smarter than mentioned, the PEN fault settings are selectable dependant on the installation and reference earthing especially if you have solar pv to avoid nuisance tripping. This manufacturer is one to watch as they are ticking alot of the boxes for the future installations.

  • @rogerbean393
    @rogerbean3932 жыл бұрын

    Just keeps on giving ! Your current transformer needs to be before the Henley block to take into account the other household loads.There was another set of tails going to a switched isolator feeding a outbuilding or garage. Good practice to keep meter tails away from Gas pipes. For reference and it’s not an electrical reg. but a gas reg. Meters and associated fittings have to be 150mm from electrical services. Gas pipework has to be 25mm from cabling or be separated by an insulating barrier or the pipework is wrapped in insulating material.

  • @justme5384
    @justme53842 жыл бұрын

    13:37 no it's spaced so you can always hit the brick and not the mortar. Never fasten to mortar, it crumbles with time and you'll have a EV charger on the ground

  • @blower1

    @blower1

    2 жыл бұрын

    Agreed - my experience of securing in the mortar, is never do it! - as you say it crumbles, or you end up with a spinning wall plug. On some properties it is tough enough for wall plugs but there is so much variability that its better to stick with going through the brick.

  • @zoltrix7779
    @zoltrix7779 Жыл бұрын

    I love watching all these videos as an Australian electrician. Things done differently in different countries. Something's are better, some things worse. Biggest thing for me is the non mechanically protected mains cables. Differences in terminology. "Main Cut-out Fuse" = "Service Fuse". "Consumer Unit" = Switchboard (Main Switchboard if its the first one after the meter). We would use a 100A service fuse on 16mm2 mains, but the power company would have us use a 63A circuit breaker as the main switch so the service fuse is the last resort. We also always have a earth electrode at each installation. Earth is bonded to neutral inside the main switchboard/consumer unit (We call it the MEN link). This is a suposed safety device to keep voltage down to around 80v or so should an exposed part become live but not enough current flows to operate a CB. Those cables clipped to the outside of the wall wouldn't be acceptable here, you would need some kind of mechanical protection, this would normally mean conduit or ducting. However, we basically never use armoured cable.

  • @awestrope74
    @awestrope742 жыл бұрын

    To truly future proof the install i would also install a cat5 for the data connection of the charger itself in addition to one used for the CT. You could use the same cat5 cable given you only need 2 pairs for a 100mb connection which would be more than adequate leaving 2 pairs for CTs

  • @k1lmo
    @k1lmo2 жыл бұрын

    I have one of these fitted, been very impressed with it.

  • @n0tryhard0nlyfun82
    @n0tryhard0nlyfun82 Жыл бұрын

    Greetings from France, I've been binge-watching your videos last few days and i had to thank you for the content and the quality of your videos / work, as an apprentice i'm learning a lot and it motivated me to make everything look NEAT. Jordan scared me a little on this one when he drilled through the electrical panel, not about the wire because i know Jordan maxed out the "Artisan Angle Drilling" skill. It was about the connections, i don't know if you use the same hole saws but ours would shake the panel so much that sometimes if the installation is old or if the work is (learned that here) "rubbish", screws of the circuit breaker could come loose creating arcing. So we do it power off and we tighten the screws just after. Anyway i was quickly reassured when the connections were tightened but i was surprised that you didnt make the correlation between the vibrations and the loosening. You have a great team and i thank you again for your work and your videos which allowed me to learn even more about our profession. A la prochaine👋

  • @geraldelwood9660
    @geraldelwood96602 жыл бұрын

    Do you really prefer to drill (for screws) into the mortar course. I have always found there is a significant risk of sandy/flaky mortar, so I will always choose the bricks to drill into.

  • @LoudAsFuckk

    @LoudAsFuckk

    2 жыл бұрын

    Same

  • @havoctrousers

    @havoctrousers

    2 жыл бұрын

    I thought everyone did this, really surprised to see Jordan fixing to the mortar.

  • @rogerbean393

    @rogerbean393

    2 жыл бұрын

    It is considered bad practice ! Only to be entertained If the bricks are crumbling and the mortar is better.

  • @michaelsimpson6603

    @michaelsimpson6603

    2 жыл бұрын

    @@LoudAsFuckk Ditto, dislike fixings in motar.

  • @nigelhudson1948
    @nigelhudson19482 жыл бұрын

    Just after you released this video my Indra Smart Pro stopped charging after about 5 months service. After a month and at the third time of asking the installer, ChargedEV, finally turned up to look at it. Turns out that the lever lock connector on the live wire of the charging lead had popped open and it had gone open circuit. The electrician said that he was not a fan of the lever lock connectors as he had several instances of them coming unlocked due to the thermal cycling of the copper cores. This simple issue has cost me a month of being able to access my EV charging tariff - I'm a very disgruntled customer.

  • @adriansmith8213

    @adriansmith8213

    Жыл бұрын

    Happened with the neutral with me. Now I'm waiting for a solid red light fix

  • @twig3288

    @twig3288

    Жыл бұрын

    Screw terminals provided they’re tightened properly are more reliable IMO

  • @jesseoconnell4369
    @jesseoconnell43692 жыл бұрын

    Excellent video Jordan, so clearly explained. Will be using this to help explain electrical installations to new ones!

  • @clintevans1357
    @clintevans13572 жыл бұрын

    Great video. As I work on one site for 9 years, I don't get to install or use new equipment or technology as much as I would like. So seeing this in this video is great. Great work. Clint

  • @PlanetCypher_
    @PlanetCypher_2 жыл бұрын

    13:49 or it ensures you always miss the mortar to make sure you get a solid fixing into the brick🤔

  • @Sunneful

    @Sunneful

    Жыл бұрын

    A pro never misses

  • @allbymyself85
    @allbymyself852 ай бұрын

    Wera tools: simply the best. That's probably the deepest explanation I could get. Thanks

  • @2Balint
    @2Balint2 жыл бұрын

    That CT clamp should be before the split!

  • @eyresysleftpeg

    @eyresysleftpeg

    2 жыл бұрын

    Only measuring half of the bloody house!

  • @abdulhaddad5454
    @abdulhaddad54542 жыл бұрын

    One of the top easy explained EV charger installation ,Well done Excellent

  • @michaelagnew7825
    @michaelagnew78252 жыл бұрын

    you are supposedto drill into the brick, spacing in brackets will also serve to avoid mortar

  • @andrewwright1200
    @andrewwright12002 жыл бұрын

    My 1971 bungalow was built with 16mm tails and a 100A service fuse. It also had 3 CU's, one with 4 circuits (cooker 32A, emersion 16A, sockets 32A, lights 6A), one with 2 circuits (Central heating 63A and central heating boost 63A), a 1 ton cast iron block heated for hot air ducted heating and the final one with 3 circuits for 3 extra night store heaters (3* 16A). Pretty sure it was pulling over 100A at times

  • @Ted_E_Bear
    @Ted_E_Bear2 жыл бұрын

    Thanks Jordan for sharing !

  • @TwineLightMedia
    @TwineLightMedia2 жыл бұрын

    One of, if not THE most engaging informative EV install videos I’ve seen. Keep it up Jordan !

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    Thanks very much!

  • @BrianFournier1
    @BrianFournier12 жыл бұрын

    Nice job Jordan!! I Ike the smart features of the charger, it’s good to see those type of capabilities!

  • @JJ-zg1hh
    @JJ-zg1hh2 жыл бұрын

    Great video. Really informative and showed all the steps for the installation. Top work!

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    Glad you enjoyed it!

  • @keis9396
    @keis93962 жыл бұрын

    Este es el mejor video en tema de información técnica de cargadores. Me sorprendió que la casa tiene altos consumo y una ducha eléctrica de 32A y agregando ese cargador se debía aumentar a 100A del disyuntor de la compañía eléctrica jajaja. Acá Chile la ducha eléctrica esta prohibido y el disyuntor mínimo que se instala en la caja de medida de la compañía es de 25A y es el consumo típico de las casas chilenas. Buen video Jordan, ¿Nathan volvió o ya no trabaja con ustedes? Saludos!

  • @shilks8773
    @shilks87732 жыл бұрын

    I believe that the vertical distance for Metric brick ( 215L x 102.5W x 65Hmm) is slightly less the the old Imperial size bricks (Pre 1960's) which were 9" x 4" x 3" (230 x 102.5 x 76) - at least the imperial size is what my bricks are.

  • @makg4655
    @makg46552 жыл бұрын

    Wow if that hole saw had just pushed through while u blinked that neutral was well mangled

  • @slimski
    @slimski2 жыл бұрын

    Really dig the Smartface tune. Thanks!!

  • @roberthodges3522
    @roberthodges3522 Жыл бұрын

    Love watching your KZread videos and I think I have nearly watched them all. I have one of these fitted some time ago and it does have quite a lot of features as in PV Sola as well and the boost function for the full 7kw. The app is good as well. Keep up the good work,👍

  • @marksmith7147
    @marksmith71472 жыл бұрын

    Jordan, great explanation regarding ownership of the services i.e. DNO, supplier etc, but could you explain the complications for houses with a looped supply, which affects us in older terraced houses? Thanks in advance.

  • @muhammadkhurshid4607
    @muhammadkhurshid46072 жыл бұрын

    Great watch, very informative as always mate. Keep them coming in 👍🏽

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    Thanks 👍

  • @alanrose4827
    @alanrose48274 ай бұрын

    I tend to fit the lower energy water heaters, they can be run on 1.5mm2 3C+E, lower bills, but must have separate circuit depending on water capacity.

  • @StuartPittaway
    @StuartPittaway2 жыл бұрын

    Shouldn't the CT clamp be on the incoming meter tails before the Henley block?

  • @sparkygazza
    @sparkygazza2 жыл бұрын

    Hi Jordan I was of the understanding that the charger had to be on a Double Pole RCD or RCBO.

  • @MrBobmeadows
    @MrBobmeadows2 жыл бұрын

    Nice use of PPE Jordan!

  • @daraoladapo
    @daraoladapo2 жыл бұрын

    Thank you for this video. I'm considering getting a good budget drill just for home DIY things. Do you have recommendations on some that can drill through walls comfortably?

  • @Chris_In_Texas
    @Chris_In_Texas2 жыл бұрын

    32:47 isn't the CT clamp on backwards? It shows the house is drawing -2725 watts on the screen. So you are generating power and putting it back in the grid? That should be a positive number. I assume there is an arrow on the CT clamp or the wiring was reversed on the unit.

  • @greaterheights7042
    @greaterheights70422 жыл бұрын

    Hey Jordan! This is amazing video ever...keep the good work going. I feel like coming over to you for internship on EV installations and other related electrical matter especially smart homes design and installations.

  • @Chris_In_Texas
    @Chris_In_Texas2 жыл бұрын

    28:10 No conduit fill regs over there, that seems really tight! 😎👍

  • @philipsmith0752
    @philipsmith07522 жыл бұрын

    well done Jordan ,

  • @eddiereed5025
    @eddiereed50252 жыл бұрын

    The first thing i did in this situation requested isolator to be fitted by supplier so that work to upgrade tails could be carried out Octopus carried this out and allowed upgrades to be completed before calling DNO. How did you go about liasing with DNO, Supplier, like you mentioned this would have been a nightmare, Or did you pull the cut out !!!! Even if you did it would have been a 100% better job if you had fitted an isolator although the tails were very short .

  • @metrotechguru5863
    @metrotechguru58632 жыл бұрын

    Very nice presentation, Jordan. Informative without dragging on with every tiny detailed. You seemed more comfortable making this vid. Good on you.

  • @harryb713
    @harryb7132 жыл бұрын

    It's always a good day when the notification pops up from KZread saying Artisan have uploaded!

  • @lucidlx
    @lucidlx2 жыл бұрын

    Shouldn’t the CT be before the Henley block split? Also CT was backwards, since reading negative values in app.

  • @johnfenlon458
    @johnfenlon4582 жыл бұрын

    What an excellent video!! That's really interesting, the charger! OMG, Not good, the gas pipe is too close!! Should be outside. Great job.. Thumbs up! Cheers! 🤟

  • @sivco
    @sivco2 жыл бұрын

    Very good video interesting. I just picked up my BMW X2 Plugin Hybrid. I can charge with 3 pin socket in the Garage , I will get EV Charger fitted. Thanks for the Video.

  • @ianlove3
    @ianlove32 жыл бұрын

    Nice job

  • @stephenfriel59
    @stephenfriel592 жыл бұрын

    are you allowed to clip the CT to the tails inside the CU?

  • @delspark
    @delspark2 жыл бұрын

    its a smart charger for sure but looks wise I'm not a fan of it. good to see you back on the tools jordan👍🏻

  • @sinanozcg250
    @sinanozcg2502 жыл бұрын

    another comment by the way - its kind a nice to me saw still someone else use drill drıvers (nowadays lots of people using impact driver and i dont know why (i think if you are not a carpender it not neccessary )) for screws .

  • @justme5384

    @justme5384

    2 жыл бұрын

    If you screw a lot of screws a day your wrist will be hurt. Mostly of course if you screw larger screws like 6x100mm etc

  • @markhowells3835
    @markhowells38352 жыл бұрын

    We have this charger constantly needs testing

  • @Chris_In_Texas
    @Chris_In_Texas2 жыл бұрын

    28:45 Not to be Safety Sally, and call you out, but is that a proper torque screwdriver for those terminal connections? (Just asking for Cory!) 😜😁

  • @tommymack3210
    @tommymack32102 жыл бұрын

    Security screws is better than snapping. I hate opening snap products when it’s -10,15 degrees celsius and the material just breaks.

  • @Vikingza
    @Vikingza2 жыл бұрын

    With networking cable, if you use 2 pair, you have a 100mbps link. If you use all 4 pairs you will have a 1gbps link. You cannot have CTs and ethernet in the same cable as the CT will interfere with the Lan connection and cause it to drop all the time.

  • @MrOcsicman

    @MrOcsicman

    Жыл бұрын

    Keep the pair twist intact when terminating the ends...this limits the cross-talk between the data-pairs.

  • @DanielPierce
    @DanielPierce2 жыл бұрын

    I would put a little plastic or rubber washer behind the mounts screw holes to fill in the gap between the depth of the mortar and the face of the brick where you screwed in the mount so that the mount doesn’t bow when screwed down tight and everything sits flush against the wall…

  • @MrBobmeadows
    @MrBobmeadows2 жыл бұрын

    If the CT clamp is attached just under the consumer unit, did it cover all the incoming grid supply? There seemed to be a split (through a Henley block) of the customer tails.

  • @2Balint

    @2Balint

    2 жыл бұрын

    Of course, it is in a wrong place!

  • @jordonbutler7509

    @jordonbutler7509

    2 жыл бұрын

    If you look closely you can see the switch is off, my guess it’s an old economy 7 install

  • @haldo691

    @haldo691

    2 жыл бұрын

    The other tails went to that ancient fused isolator with piro coming out of it probably a garage supply

  • @sparkstack

    @sparkstack

    2 жыл бұрын

    It doesn’t look like it. Curious also why it was reading a negative number. I think it was the wrong way around.

  • @aido88
    @aido882 жыл бұрын

    Are you using a torque screwdriver on the DB?

  • @BerkeleyTowers
    @BerkeleyTowers2 жыл бұрын

    Ref your comment about the age of the incoming mains....... I had the DNO out recently to replace the meter board and uprate the incoming fuse, and I asked whether the age (64 years) of the incomer was an issue...... he said that (in his opinion) it was better quality than the stuff they put in new installs..... So, who knows? I would echo others with not going into mortar lines with fixings.....And whilst the idea of putting the mounting holes at standard brick/block spacings is great in theory, I don't think they've ever been out on site and measured real life brickwork! Which leads to the worst of both worlds of holes half in/half out on the edge of mortar lines. Middle of the brick every time!

  • @makg4655

    @makg4655

    2 жыл бұрын

    Mortar fixings is just for ease and use the mortar line as a guide

  • @JC-jv5xw

    @JC-jv5xw

    2 жыл бұрын

    I had exactly the same comment recently. DNO fixed a high Ze (1.5ohm) on a TN-S supply, old lead/paper/tar cable from either the 60s or possibly even the 1930s. Asked the guy if the cable was deteriorating and he said it was fine and would last longer than any replacement they could put in. (Fix was shorting N-E in a new junction about half way back to the road, Ze now down to 0.25. I suppose/hope the road supply was already PME?) .

  • @haldo691

    @haldo691

    2 жыл бұрын

    The old paper lead cables were much better made than the new plastic cables unless it's a joint or damage the cables very rarely fail

  • @Dibbo1979
    @Dibbo19792 жыл бұрын

    Great video. 👍🏻

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    Glad you enjoyed it

  • @tonywood6332
    @tonywood63322 жыл бұрын

    I have the Indra, but like your man, waiting for my car (was due end Jan, now May 😏) Nice video 👍

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    Awesome! What vehicle do you have on the way?

  • @tonywood6332

    @tonywood6332

    2 жыл бұрын

    Nissan Leaf (the 62kwh one)

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    Nice!

  • @wrdcc01
    @wrdcc012 жыл бұрын

    A small block of wood when you're drilling towards a gas pipe and the internals of the CU. Those screws are not nails and drill into the brick not the weak mortar.

  • @davegeorge7094
    @davegeorge70942 жыл бұрын

    USA home standard is one 200amp panel w/split phase.

  • @cj-rb8fz
    @cj-rb8fz2 жыл бұрын

    Bonding clamp on paper Lead armoured 🙈, 3m of flexi tails and no switch fuse isolator 🙈 and fixing into courses instead of bricks 🙄, and board right near gas meter and pipe work

  • @mikeenglish1492
    @mikeenglish14922 жыл бұрын

    Good vid, camera work excellent 👌

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    👌🏼

  • @makg4655

    @makg4655

    2 жыл бұрын

    That’s what happens when u set up a media company and use camera men/ women instead of raw electricians showing themselves graft

  • @adammorehouse7664
    @adammorehouse76642 жыл бұрын

    My question is, could the client set up different accounts for different users if there were 2 or 3 EVs in the home?

  • @akramali598
    @akramali5982 жыл бұрын

    Nice work man

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    Thank you! Cheers!

  • @LoudAsFuckk
    @LoudAsFuckk2 жыл бұрын

    Fischer Duopower are king of wall plugs, no comparison

  • @jonnysegway7866

    @jonnysegway7866

    2 жыл бұрын

    Amen to that

  • @TWOKDOK1
    @TWOKDOK12 жыл бұрын

    I’m sure it won’t be long before security cabinets for charging points will become necessary, to inhibit people nicking your charging point and cable. ‘Security’ screws are a bit of gimmick.

  • @rogerbean393
    @rogerbean3932 жыл бұрын

    Did you miss the switched isolator coming of the Henley block , not worth considering ? Did you do a ZE on the 6mm existing Earth ? What rating is that charger 7.2kw ? Why is cable not armoured ? It’s going down the drive

  • @davewright22
    @davewright222 жыл бұрын

    Did anyone spot Jordan had fitted the CT clamp the wrong way round? 32:30 shows a negative current draw,. Unless of course there’s solar PV.

  • @jacopo.scarpellini

    @jacopo.scarpellini

    Жыл бұрын

    I was just looking for this comment

  • @markdonovan6715
    @markdonovan6715 Жыл бұрын

    Great video got my EAL ev charging course in 2 weeks how did you find it Jordan?

  • @scubasteve115
    @scubasteve1152 жыл бұрын

    Your videos are so helpful for an apprentice like me, keep it up

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    Good to hear!

  • @williamanthony7224
    @williamanthony72242 жыл бұрын

    Fun fact. On the data cable you if fit clamps to the blue and brown pairs you can still use the other pairs for a 100mb network connection. also, I may have lied about this fact being fun.

  • @aaronworley556
    @aaronworley5562 жыл бұрын

    The main fuse doesn't protect the dno cable, it protects the meter tails.

  • @FokkoDriesprong
    @FokkoDriesprong2 жыл бұрын

    Have you looked into the SMA one? Can't think of a SMArter one :)

  • @HousewerkRecords
    @HousewerkRecords7 ай бұрын

    Great vid. How do you rate the Indra against the Hypervolt Home 3 Pro and the PodPoint Solo 3? Be interested to know your thoughts. The Hypervolt has Remote locking of the ev point which is good to stop cheeky undesirables trying to charge when your out or away.

  • @alanjrobertson
    @alanjrobertson2 жыл бұрын

    Really nice clear explanation at the top re fuse/meter/consumer unit, thanks Jordan 👍 PS when's the behind the scenes video re EV ultra/Doncaster cables due? (don't think I've missed it?!)

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    The factory tour will be coming out soon 👍🏻

  • @slimski
    @slimski2 жыл бұрын

    Also, the spelling of Rawl plug Respect John Joseph Rawlings

  • @Marks-Garage
    @Marks-Garage2 жыл бұрын

    In regards to the incoming fuse upgrade if the property had very little load ie, no electric shower and bog standard 3kw oven is there any real need to upgrade the fuse? I have 60amp fuse on my incomer and at some point i want to get an ev charger fitted (spare ways on the board). I cant see why i would need to upgrade when my max load would only get to say 45-50 amps

  • @jamieh8667

    @jamieh8667

    2 жыл бұрын

    If your installer fits ALM then no upgrade is required.

  • @haldo691

    @haldo691

    2 жыл бұрын

    No if you're smart or have load management you'll be fine

  • @lee.m.bennett2635
    @lee.m.bennett2635 Жыл бұрын

    Whilst I agree with the upgraded tails. Back in the day 16mm was always used on 100A supplies. And the incoming PILC cable will be 16mm 😂 Great job though

  • @rosshannemann7772
    @rosshannemann77722 жыл бұрын

    I never drill into mortar, it can collapse, prefer brick, much sturdier.

  • @markjlewis
    @markjlewis9 ай бұрын

    Was the CT giving a negative reading i.e it was installed the wrong way around?

  • @royyoung3104
    @royyoung310411 ай бұрын

    Anyone else just think that to get Electric cars a viable proposition for EVERYONE is pie in the sky!!! Just had my survey done and the amount of work involved infitting to a ' relatively ' modern terrace house was ridiculous. Goodness knows what woukd have been needed in my old Victorian terrace house... What a load of Green Bollox!!!!

  • @mimikm222
    @mimikm2222 жыл бұрын

    Sir, no crimps into those terminals? 20:34

  • @oliverhiestand7098
    @oliverhiestand709810 ай бұрын

    Are there ev chargers with dynamic load balancing that work with a off grid system that charge more when there is sun and know the status of the battery?

  • @user-qg1gt8tt3z
    @user-qg1gt8tt3z2 жыл бұрын

    What is the installation cost may be for such installation in UK?

  • @malcdickinson06
    @malcdickinson0610 ай бұрын

    Great video, can you answer a question for me. I have a BP pulse (new WiFi version) that is useless. A friend gave me a Podpoint. He has had his name removed from the charger so he’s no longer associated with the charger. Can I have this installed to replace the BP pulse. Thanks! Malc.

  • @jasontibbitts5231
    @jasontibbitts52312 жыл бұрын

    Should you have not added you link cable when you null leads R1 R2

  • @ctsungyi1984
    @ctsungyi198411 ай бұрын

    Very surprised the Power supply inside is Open frame style or PCB style. Curious about long term life time with moisture, temp .

  • @phallanxian
    @phallanxian2 жыл бұрын

    Did you have to install the charger to get the VW home?

  • @artisanelectrics

    @artisanelectrics

    2 жыл бұрын

    🤣🤣🤣

  • @7123
    @71232 жыл бұрын

    Not going to lie, that charger looks like a cheap soap dispenser. Would be ok inside a garage, but would not want that fitted in a visible location outside my house. I understand your reasons for screwing into mortar, but mortar degrades over time hence why houses need repointing (process of renewing the mortar between the bricks) after so many years. Personally would feel more comfortable seeing it installed to brick work so its more secure, especially on a charger where the cable is going to be pulled about to plug into a car. As always though, nice professional install other than that :)

  • @Gr33nMamba
    @Gr33nMamba2 жыл бұрын

    I quite like this charger, slightly industrial but reassuring. Knowing I have the horrible old main incoming supply cable as described, and a 60 Amp cartridge, it's definitely something I will have to consider knowing whatever charger I go for has the ability to limit load, as I'm not sure how much pain and expense there would be dealing with Western Power. Personally I would have used a hard wired data connection any day of the week. The potential for having to reconfigure devices when the customer changed their router (assuming it's all ISP provided defaults) makes it a pain. Even if you just broke the data out in the cupboard, installed another 13Amp socket and used powerline to get back the router location, that would be easier to support long term. Ultimately if the customer is happy!

  • @aaaa-ig6sc

    @aaaa-ig6sc

    2 жыл бұрын

    I was told by ChargedEV that installed mine that they always recommend the data dongle first, only if you really don't get any mobile signal then go for ethernet, and then only go for home WiFi if the ethernet isn't practical as a last option.

  • @MG_Steve

    @MG_Steve

    Жыл бұрын

    @@aaaa-ig6sc Yeah, I had my Indra Pro installed by them too. Weird suggestion tbh as hard wired should be the most reliable, but I work in IT and as there was a in-wall switch the inside wall of the mounting point for the charger, I just wired in a weather proof Cat 5/6 (can't remember which now) into the switch and the installer just wired the other end into the charger. If you do hard wire it, make sure you use external grade CAT5/6 cable (unless it goes directly into the charger I guess), mine had a run of about 30cm. Normal Cat 5 will degrade pretty quickly in sunlight & weather.

  • @jdaley197931
    @jdaley1979312 жыл бұрын

    Hi Jordan. Please tell me that in the clips from 22:40 to 22:50 you had the main fuse removed?

  • @haldo691

    @haldo691

    2 жыл бұрын

    Yes he did you can see it's missing when they are pulling the tails through the conduit

  • @jdaley197931

    @jdaley197931

    2 жыл бұрын

    @@haldo691 I was just a little concerned as all the breakers, rcds and main switch were still switched on.

  • @0072sy
    @0072sy2 жыл бұрын

    Looking at that EV cable with the cat5 cable inside, I was always told keep your data cables away from electrical cables due to the interference and degraded network signals. Is this not the case these days?

  • @MrBobmeadows

    @MrBobmeadows

    2 жыл бұрын

    Generally the Cat5e is shielded inside EV Ultra-type cables.

  • @duzzah

    @duzzah

    2 жыл бұрын

    @@MrBobmeadows shielding only works if one end is grounded, didn't use a shielded cat 5 plug or ground the other end?

  • @timbo19

    @timbo19

    2 жыл бұрын

    Interference just isn't that big of an issue. Remember that the electromagnetic fields around the live and neutral wires are the same but opposite polarity. That along with them being gently twisted along the length of the cable ensures effective cancellation and thus induction into adjacent cables isn't a significant issue. For the same reason, if measuring current with a clamp meter you have to put it around one wire only as if you put it around the whole cable you get a zero reading. In addition, the wires in the CAT cable are arranged as twisted pairs for the purpose of common mode rejection. Shielding isn't relevant to EM fields, it's purpose if present is for rejecting RFI.

  • @MrOcsicman

    @MrOcsicman

    Жыл бұрын

    These are digital, not analogue signals...using twisted pairs and a floating data ground...most modern ethernet devices can withstand and maintain the required data throughput these days

  • @wobby1516
    @wobby15162 жыл бұрын

    Does it work with solar panels in the way that Myenergi’s Zappi can.

  • @mattyt6722

    @mattyt6722

    2 жыл бұрын

    Still nothing new zappi does all of this and more.

  • @silverghini2629
    @silverghini2629 Жыл бұрын

    Is a 32amp mcb enough for a unit that can draw up to 32amps?

  • @hallga2
    @hallga22 жыл бұрын

    why would you not want security screws on the cover??

  • @PlanetCypher_
    @PlanetCypher_2 жыл бұрын

    23:32 I was under the impression you should not have cable inside a CU that is not rated for 240v, the cat5 is surely not, should it have been hived off inside a wiska before passing through the conductors?

  • @havoctrousers

    @havoctrousers

    2 жыл бұрын

    None of the inner conductors are exposed in the CU, it's only the cat5e sheath. If the cat5e sheath wasn't rated for 240V then it also wouldn't be rated for being inside that NYY-J cable at all?

  • @PlanetCypher_

    @PlanetCypher_

    2 жыл бұрын

    @@havoctrousers yes my thoughts exactly, it seems the cable does not conform to a specific BS standard as yet anyway, just that you should follow the manufacturer’s instructions/guidance.

  • @roymorton8142

    @roymorton8142

    2 жыл бұрын

    I don’t think the data cable should be incorporated inside a 240v cable anyway

  • @TWOKDOK1
    @TWOKDOK12 жыл бұрын

    Didn’t see torque screwdriver being used ?

  • @LoudAsFuckk
    @LoudAsFuckk2 жыл бұрын

    Is there a reason you didn't put the CT clamp inside the board?

  • @tommymack3210

    @tommymack3210

    2 жыл бұрын

    Probably because it was stuffed or hindrances.

  • @carlseddon2392
    @carlseddon23922 жыл бұрын

    I presume you drilled upwards as well to stop water going down the cable. Haven't seen the end yet so I presume again you use sealant