Fujitsu Thermostat: Activate sensor reading
Ғылым және технология
In this video we will explain how to configure the Fujitsu AC unit so the Airzone Eco-Adapt algorithm works correctly.
To do this, the “switching function of the room temperature sensor” must be enabled. Without this, the system will only work with maximum and minimum temperatures and won't permit the use of the Airzone system's Eco-Adapt algorithm.
To configure this function, follow the following procedure:
1. Press and hold the “ECONOMY” button. A key will appear on the screen if the AC unit does not have this parameter configured.
2. Access the settings menu by pressing the “SET TEMP” and “FAN” buttons at the same time. Using the time setting buttons, navigate to position 42 on the menu: the “switching function of the room temperature sensor”, and using the “SET TEMP” buttons, set it at 01. To save the new settings, press and hold “TIMER SET” until the values on the display stop flashing.
3. Next, change menu function number 48 to position 01 to use the temperature sensor on your AC unit's remote controller, and save the configuration.
4. Switch off the indoor unit’s power and switch it on again. Press “ECONOMY” again, and the icon that corresponds to the function will appear, confirming that the change has been made.
Lastly, to ensure that the configuration is not lost, for example, in the case of a power outage, open your thermostat and locate the DS1 microswitch. Set PIN number 6 in the ON position.
Пікірлер: 16
When would I have to set the unit number? I have two air handlers connected to my Fujitsu outdoor heat pump. Both wired controllers are set to unit number 00. When would I have to set them differently? Main reason why I'm asking is, I installed a UTY-TTRXZ1 thermostat converter and everything is installed correctly, but the air handler does not come on. I'm wondering if I have to change the unit number using the old Fujitsu wired controller prior to installing the converter and a standard thermostat.
Great video cheers!
Hola, donde puedo conseguir todos las configuraciones de este mando por favor
I want to ask a question how do I turn off the timer
I have a auu18rfl unit with wired controller and setting 42 and 48 set to "01". The controller still shows a key when I try to enable "thermo sensor." Why can't I enable the thermo sensor setting? I cang find any info.
@kshahkshah
Жыл бұрын
Same
chenge minimum temperatures setting fujitsu remote control please video
Error coming what can I do
@brendenbanks9293
Жыл бұрын
You ever figure this out? I have a auu18rfl unit with wired controller and setting 42 and 48 set to "01". The controller still shows a key when I try to enable "thermo sensor."
Outdoor unit address Master & Slave compressor Inverter on Fixed compressor off
This video is particularly hard to use. 1/10.
This video is bad. It has no context to explain why someone would want to do this. Fail.
@ninoaniceto
Жыл бұрын
You would do this if you want to use the controllers thermostat instead of the unit which in my case was in the attic.
@phxhoward
4 ай бұрын
This should be the default. Why would anyone want to use a temperature sensor in some remote crawl space rather than the one in the room?
The presentation was big gay.