Fixing a Partial Chronograph Problem in a SII/Seiko VD57B Watch Movement How To

Тәжірибелік нұсқаулар және стиль

What is causing a partially non working chronograph in a VD57B by SII/Seiko watch movement? This video demonstrates how to find a root cause by investigating all possible scenarios. Procedure of repairing the watch is also shown.
Thank you for watching and please do not forget to give me a thumbs up!
Subscribe to my channel and check Bell for All to be notified about my future video posts.
Below are the links to the equipment, tools and materials I use when working on the watches. These links are paid by Amazon Associate program and if you use them to make a purchase, as an Amazon Associate, I will earn from qualifying purchases and it will help to support the channel:
TOOLS:
Digital microscope for inspection and recording: amzn.to/3QzyQPi
Bergeon 9-piece Screwdrivers: amzn.to/3CMpRoe
Bergeon 55-710 Set of 4 Oilers: amzn.to/3GXoZPd
5 Dish Watch Oiler Set: amzn.to/3QFDewu
Screwdriver Sharpening Holder: amzn.to/3ZKBGWb
Sliding Nickel Handheld Pin Tong Vise: amzn.to/3ixo2EQ
2L Degas Sweep Ultrasonic Jewelry Cleaner: amzn.to/3CKYvis
Motorized Rotating Display Stand: amzn.to/3GDi11B
Stand with Double Non-Slip Clamping Pad: amzn.to/3X9IQ4i
VIDEO and AUDIO:
Main video recording photo camera #1, Canon EOS RP: amzn.to/3IMwr28
Main video recording photo camera #2, Sony 6400: amzn.to/3kdFzT9
Secondary video recording photo camera, Fujifilm FinePix SH10: amzn.to/3D7y1bh
EF-R2 EF to RF Adapter for Canon RP: amzn.to/3XJOPgn
Canon EF Lens to Sony E Mount T Smart Metabones Adapter: amzn.to/3W6hoD9
Canon EF 100mm f/2.8L IS USM Macro Lens: amzn.to/3Qy5RM1
Canon EF-S 60mm f/2.8 Macro USM Fixed Lens: amzn.to/3W9Kd1N
Rode VideoMicro Compact On-Camera Microphone: amzn.to/3kh7GAY
Blue Snowball USB Microphone: amzn.to/3CKR0b9
ACCESSORIES and MATERIALS:
Small Ultrasonic Task Jewelry Cleaning Basket: amzn.to/3XtCSuO
Ultrasonic Cleaner Parts Basket: amzn.to/3kcsGbX
Troop-Balas Laboratories One-Dip Watch Cleaner: amzn.to/3W8x0WZ
Testor's 1139TT 1/4 Oz Black Semi Gloss Enamel Paint: amzn.to/3ZBwUdd
Articulating Magic Friction Arm: amzn.to/3GGk0ls
SMALLRIG Super Clamp: amzn.to/3IFhGhs
J-B Weld 8276 KwikWeld Quick Setting Steel Reinforced Epoxy: amzn.to/3w1p670
Parts Storage Box: amzn.to/3X9NZt9
Isopropyl Alcohol 99% (IPA):amzn.to/3CKO3aR
Heat Resistant Tape: amzn.to/3l0ZOE5
7PC 3 Inch Buffing Wheel Kit: amzn.to/3IGWVC5
24 Outlet Heavy Duty Multi Plug: amzn.to/3ZrkswN
3M Rugged Comfort Quick Latch Reusable Respirator: amzn.to/3X6a6k9
3M Respirator Cartridge 6006: amzn.to/3Xpmfk3
PolyWatch Plastic Watch Crystal Scratch Remover Polish Tool: amzn.to/3ixBWXJ
Lansky Ultra Fine Sharpening Hone: amzn.to/3Zwunku
The Watch Repairer's Manual: amzn.to/3WabpNP
WEN Drill Press Table: amzn.to/3QlbLSe
24V DC High Torsion Reversible Motor: amzn.to/48UGCMq

Пікірлер: 57

  • @omerfar
    @omerfar3 жыл бұрын

    You are the only person on youtube who shows so many quartz watches fix . Thank you.Keep it up

  • @ValentechTime

    @ValentechTime

    3 жыл бұрын

    Thank you for your comments! I really appreciate them.

  • @youngwatchrepairer4924
    @youngwatchrepairer4924 Жыл бұрын

    Thank you for all the explanation and repairs. You help me a great deal. I am a young upcoming watch repairer in my country

  • @dajughe3919
    @dajughe39193 жыл бұрын

    Thank you much really nice video!!!!

  • @ValentechTime

    @ValentechTime

    3 жыл бұрын

    Glad you liked it!

  • @dodgydruid
    @dodgydruid3 жыл бұрын

    Damn, wished I'd seen this before buying in two new 57 movements lol

  • @windward2818
    @windward28188 ай бұрын

    Just a note to the viewers. If you want to handle a battery with tweezers use plastic tweezers so you don't short it out even if you plan on eventually replacing it. Why, because if the battery still has some charge you can test the repaired movement with the old battery, and once you are satisfied it is working properly, then install a new battery for the customer, do final assembly, test, correct default hand position, set and deliver to the customer. New VD57B movements are readily available for less than $20.00 each. You can buy several and strip for parts if you want to. Before installing a new electronics flex circuit, it is wise to clean the contact pad oxidation with Deoxit D5L in the liquid applicator bottle, use a lint free swab.

  • @ValentechTime

    @ValentechTime

    8 ай бұрын

    I agree with the battery handling, of course plastic tweezers should be used. So far I dealt with about 8000+ watches, both quartz and mechanical and I have a stock of wide spectrum of watch movements for using as spare parts., so I buy a new movement very seldom. In regards of cleaning the traces of electronic board I will disclose some secret to you. I am an electrical design engineer by profession, watchmaking is just my hobby and I learned how to handle electronics a long time ago. In this case I took already de-oxidized board from stock, but removed a dust by Rodico. Anyway, thanks for your notes.

  • @Joyz99
    @Joyz999 ай бұрын

    Hello. I have same issues like this video. I replaced the ic but it still the same. Can you tell me how to fix that? Thanks before

  • @ValentechTime

    @ValentechTime

    9 ай бұрын

    If it's not the electronics module, which you had already replaced, then some mechanical issue in the are of coil, associated with the faulty subdial. I pointed to this possibility in the video around 3 min time point. Try to disassemble that area and see if there is anything suspicious, like broken tooth or some bent, or just a dirt. Good luck!

  • @Joyz99

    @Joyz99

    9 ай бұрын

    @@ValentechTime ok..thanks sir..

  • @anchietaferreira4603
    @anchietaferreira4603 Жыл бұрын

    Muito bom o seu vídeo!!! 👏🏻👏🏻👏🏻 Peço que me tire uma pequena dúvida... No caso de uma revisão, eu poderia usar o Moebius 8000/4 em todos os ponto de lubrificação ? Desde já agradeço pelo seu feedback 🤝🏻

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    Thank you! Moebius 9000 oil is preferable for quartz watches, but 8000 should be sufficient as well. Good luck!

  • @anchietaferreira4603

    @anchietaferreira4603

    Жыл бұрын

    ​@@ValentechTime , muito obrigado pelo retorno..

  • @Denis_Holden
    @Denis_Holden2 жыл бұрын

    Hi! Can you be so kind to look on my problem? Do you have any ideas about this? I noticed in the manual that you are supposed to do an IC reset by pressing the A and B buttons. I did that and since then the button A when pressed makes a weird beeping sound. If I press it several times then the chronograph starts to work. When pressed a second time it beeps and it resets. And all these after the IC reset. I tried to reset the IC again and again but the problem persists. Any ideas on how to solve the issue. Thank you.

  • @ValentechTime

    @ValentechTime

    2 жыл бұрын

    I assume, you have the same movement in your watch. It doesn't have a mean of providing any sound, so I wonder where the beeping sound comes from. At the same time, I think your movement malfunctions and needs repair or replacement. Sorry, cannot help more. Hope you will get your watch back to normal.

  • @mikerelo6326
    @mikerelo63263 жыл бұрын

    Can you show me what design is the stem in this watch movement?

  • @ValentechTime

    @ValentechTime

    3 жыл бұрын

    I cannot show the stem outside of the video, but I can refer you to the part number of the stem. It is 351177. If you look it at Google, it will list multiple sources where this stem could be bought. One example is here: www.ebay.com/itm/Hattori-Seiko-Watch-Winding-Stem-VX32-VD53-VD57-58-59-67-Part-351-177-Fast-Post-/123032187108

  • @anchietaferreira4603
    @anchietaferreira4603 Жыл бұрын

    Bom tarde meu nobre! Consegui um relógio fóssil nesse mesmo modelo, e constatei que ele tá descarregando muito rápido a bateria. Por sua experiência... Qual seria o defeito? Que peça nesse caso deveria ser feito a reposição? Muito obrigado 🤝🏻

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    Hi Anchieta! I'd check the battery first by trying another one. Next I'd check if there is some shortage in the battery compartment. If no shortage, then I'd replace an electronic board, because this is what takes energy from the battery - this module and coil. But if watch shows a correct time, then coil is OK. Replace module, if you can. Good luck!

  • @anchietaferreira4603

    @anchietaferreira4603

    Жыл бұрын

    Muito agradecido pela informação! Sucesso sempre! 🤝🏻

  • @AnandSingh-fi6zq
    @AnandSingh-fi6zq3 жыл бұрын

    Sir how to check electronic bord pls explain it sir

  • @ValentechTime

    @ValentechTime

    3 жыл бұрын

    Thank you for your question. The electronics module (board) could be checked indirectly by checking the coil resistance. If coil is good, but watch doesn't work at all, then electronics board should be suspected. Before any conclusion, the battery also should be checked. Another reason for watch being non functioning could be any hard mechanical problem caused by water damage, rust, broken gears. Horological methods have many procedures of testing quartz watches at manufacturing labs, using expensive equipment. Here is a link, showing that kind of testing: kzread.info/dash/bejne/p32t0tWvoJyqZpc.html

  • @samblack1975
    @samblack1975 Жыл бұрын

    is vd 57 the same as Vd57b....... i have the same problem with the three sub dials that do not work, the coils work , where can i source an electronic board for this watch

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    These movements are the same with the difference of date window orientation. I never saw VD57 without letter at the end, and my search showed that VD57 and VD57B are the same movement with a date window at 3:00 o'clock. It also can be used for dials with a date window at 4:30. The VD57C is the same movement, but has a date window at 4:00 o'clock position. If you do not have spare electronic module, then maybe replacing a whole movement is more effective. I just found one on eBay at around $13. Just an option - www.ebay.com/itm/403123317592?hash=item5ddc05ab58:g:PhgAAOSwK71hL7wi

  • @samblack1975

    @samblack1975

    Жыл бұрын

    @@ValentechTime Thanks for the information .... I like your displaying of quartz watches and you responses to questions..............

  • @omerfar
    @omerfar3 жыл бұрын

    can you please show how to fix a seiko flightmaster?

  • @ValentechTime

    @ValentechTime

    3 жыл бұрын

    I do not have a Seiko Flightmaster watch in my possession, but plan to work on many other watches, both quartz and mechanical. Thank you.

  • @yogadimas9643
    @yogadimas9643 Жыл бұрын

    Hello.. I have a problem here.. My vd57b draining batteries after 5-6 hours (Sony SR920SW).. And yes I do circuit reset after replacement.. What I mean by 'drain' is the battery doesn't response after checking it in microtest (cell).. After about an hour, the 'drained' battery hve small response in cell test and can be used again for 30mins.. I hope I have clue what happening..

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    Hi Yoga Dimas! I see two reasons of the battery got drained so quick. One - is the battery itself. Did you try another battery? The second reason is the electronic module, which might become defective, or has some dirt that is causing some shortage. The module could be replaced, if you can find a donor. Hope this helps. Good luck!

  • @yogadimas9643

    @yogadimas9643

    Жыл бұрын

    Thanks for quick replay.. So it's the IC itself.. I'll try replace with new IC :)

  • @yogadimas9643

    @yogadimas9643

    Жыл бұрын

    Fyi I tried another brand, also tried LR battery.. Already cleaned the circuit

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    ​@@yogadimas9643 Cleaning the module is fine, but if it's defective, than cleaning wouldn't help. I got another idea why the drain can occur. It could be a shortage in one of the coils. If you can measure the coils resistance it could give a clue. The normal resistance for this movement is within 1-1.3K.

  • @yogadimas9643

    @yogadimas9643

    Жыл бұрын

    It shows the same R level "30" for all three coils

  • @TravelWithMEnow
    @TravelWithMEnow Жыл бұрын

    I have an issue with this same movement. It stops every night at around midnight. After I pick up the watch it starts running normal again until put down and again stops at midnight. Any ideas as to what’s wrong with it?

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    Does it happen at midnight only or also at noon with the same hands positions? If you answer this question, it would become easier to get some clue on the issue. Thanks.

  • @TravelWithMEnow

    @TravelWithMEnow

    Жыл бұрын

    @@ValentechTime only right before midnight

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    @@TravelWithMEnow I think it could relate to the date change at midnight, when date indicator ring starts to move and via some gears could prevent hour and/or minute wheels from advancing. Does seconds hand moves back & forth or it just stops also?

  • @TravelWithMEnow

    @TravelWithMEnow

    Жыл бұрын

    @@ValentechTime the second hand just stops also. The second I pick up the watch it starts running again.

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    @@TravelWithMEnow Did you check if hands touch each other or second hand touching the crystal (even slightly) at midnight point, when watch stops? There is a small chance they do, because they pass the noon point without problem, but it would be worth to check.

  • @samblack1975
    @samblack1975 Жыл бұрын

    What is the difference between Vd57B .VD57C and VD57?

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    Please see my reply on your comment yesterday. I modified it to be more accurate.

  • @henriqueabreu1928
    @henriqueabreu1928 Жыл бұрын

    O que foi feito, não entendi?

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    Se reemplazó el módulo electrónico para solucionar el problema; esto es lo que se hizo. ¡Gracias por ver!

  • @1961UK
    @1961UK Жыл бұрын

    I have just bought this watch from ebay and it's not working. Battery is 1.54vs so i will check the coils and mechanics if all OK maybe change the circuit board as you did.

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    You have a good plan. Sometimes putting a little bit of oil to the pivot holes can get gears moving. Good luck!

  • @1961UK

    @1961UK

    Жыл бұрын

    Yes I'll do that. Thanks

  • @1961UK

    @1961UK

    Жыл бұрын

    Sadly the cools have resistance and the circuit is all black. Looks like I need a new movement shame. The seller was very dishonest regarding its condition.

  • @ValentechTime

    @ValentechTime

    Жыл бұрын

    @@1961UK Resistance in coils is a good news. The color of the electronics module doesn't prove much that it's not good. Maybe you can find spare. But if both coils and board are good, then I'd disassemble the movement to see what's wrong or just it needs cleaning. I think you already know all these suggestions. 😃

  • @1961UK

    @1961UK

    Жыл бұрын

    @@ValentechTime Decided to buy and new movement which i'm replacing now. Thanks for your advice.

  • @Arthurzeiro
    @Arthurzeiro2 жыл бұрын

    The tachymeter is really useless since the central seconds hand isn't the chronograph.

  • @ValentechTime

    @ValentechTime

    2 жыл бұрын

    I agree, I think they put tachymeter for fashion purpose

  • @HebertBarra
    @HebertBarra3 жыл бұрын

    Good! Where are his accent?

Келесі