Do you face the same problem AC blinking | error UF | Daikin RZR125LVVM

Brand : Daikin super inverter
Model : RZR125LVVM
Error : UF
Cause : Insufficient gas / indoor liquid temperature thermistor reading abnormal / communication error
#bonmj #airconditioner #daikin

Пікірлер: 38

  • @solfron1759
    @solfron175911 ай бұрын

    Nice work of error trouble shooting master tech AC

  • @BonMj

    @BonMj

    11 ай бұрын

    Thanks

  • @madman198585
    @madman19858511 ай бұрын

    Very good job ❤

  • @BonMj

    @BonMj

    11 ай бұрын

    Thanks 😄

  • @Marcoguima45
    @Marcoguima4511 ай бұрын

    Good Job!😎🇧🇷

  • @BonMj

    @BonMj

    11 ай бұрын

    Thanks

  • @salimagwan9672
    @salimagwan967211 ай бұрын

    good evening bon sir we don't have d-cheker so how our work will be easy find all parameter is a very difficult task plz make a video on d-cheker too

  • @mymusic-tp1bh
    @mymusic-tp1bh8 ай бұрын

    Compare the discharge temp and high pressure, which is more critical when filling gas? The high pressure 705psi too high?

  • @salimagwan9672
    @salimagwan967211 ай бұрын

    👍

  • @BonMj

    @BonMj

    11 ай бұрын

    Thanks

  • @aus_aircon_ref_mech6671
    @aus_aircon_ref_mech667111 ай бұрын

    Hello Uncle Bon Were you able to find the leak? Could the faulty thermistor make the system think it is low on charge since the temperature reading was out by roughly 20°C?

  • @thinhtranphuc4469
    @thinhtranphuc446911 ай бұрын

    do you have documentation on test run of panasonic vrf system?

  • @guardian7keys
    @guardian7keys2 ай бұрын

    Daikin seems regular have UO problems

  • @sv6k0a39
    @sv6k0a3911 ай бұрын

    UF Error also says "Improper connection of transmission wiring between indoor-outdoor units, Failure to execute check operation, Defective indoor unit PCB , Stop valve is not opened." Very vague error code it seems. I guess if there is a gas issue, this error will also show up?

  • @francis_Teo_KY
    @francis_Teo_KY11 ай бұрын

    Uo leak gas. Why nv check leak m charge on gas only

  • @muruganantham595
    @muruganantham59511 ай бұрын

    Hi boss , I have an doubt abou,t how much of amount of oil need to charge during accumlator oil return valve and body replacement , and also what's is the easiest method to top up

  • @karaors8970
    @karaors897011 ай бұрын

    👋🧿👍

  • @BonMj

    @BonMj

    11 ай бұрын

    Thanks

  • @gamsanthosh
    @gamsanthoshАй бұрын

    Error code UF ,I face exactly same problem on this model 3month earlier,symptoms unit run exactly 30min without any issue afterwards blinking UF we replaced indoor thermistors still running without any issues

  • @BonMj

    @BonMj

    Ай бұрын

    👍👍

  • @user-cz1gz7gb6p
    @user-cz1gz7gb6p7 ай бұрын

    Hi ser i m morshed

  • @BonMj

    @BonMj

    7 ай бұрын

    👍

  • @victorarguello6019
    @victorarguello601910 ай бұрын

    What is the normal liquid temperature and what is the gas temperature in this type of system?

  • @rjmintu1703
    @rjmintu170311 ай бұрын

    Carrier vrf cassette indoor display show EE error in display .we replaced indoor pcb and new drain pump with float switch , display, and clean drain line but EE error has been not remove Can you ask me . Whats component faulty Reply plz Love from india

  • @sonukurmi305
    @sonukurmi30510 ай бұрын

    Fan qail unit communication errors

  • @macmacsumarapnah1906
    @macmacsumarapnah190611 ай бұрын

    What kind of app is that sir

  • @sv6k0a39
    @sv6k0a3911 ай бұрын

    Doesn't UF Error Code mean "System Communication Fault"?

  • @shibashishyamohanty9819
    @shibashishyamohanty98199 ай бұрын

    I want to work with u if any vacancy let me know

  • @mohdhafizan4379
    @mohdhafizan43799 ай бұрын

    vrv2 errod uf masalah pa

  • @BonMj

    @BonMj

    9 ай бұрын

    Check communication wire

  • @janshaw5472
    @janshaw5472Ай бұрын

    所以这个uf 的问题是gas 不够么?

  • @BonMj

    @BonMj

    Ай бұрын

    UF 可以是gas不够,Fcu thermistor 坏,或EEV 坏

  • @khaerulanam5581
    @khaerulanam558110 ай бұрын

    Sorry master, i have trouble abaut motor blower indoor, i was set HH but speed not going faster. What trouble.? 🙏

  • @khaerulanam5581

    @khaerulanam5581

    10 ай бұрын

    Vrv IV

  • @BonMj

    @BonMj

    10 ай бұрын

    Check dc fan or ac fan, if ac fan please check fan capacitor

  • @tom24057
    @tom2405711 ай бұрын

    Not good! U0 System is leaking