Diagnosing Daikin UF Error

Daikin UF Fault Description: Incorrect wiring /piping.
However I find the fault is most commonly caused by a faulty board (not incorrect wiring).
Below I have listed the Tool Bag and Tools that you see me use personally in my videos. By using these links it doesn’t cost you anymore however by doing so you are helping the channel grow.
Thanks for the support!
MILWAUKEE BACKPACK (I use this backpack as my Service Bag).
www.amazon.com.au/Milwaukee-P...
FLUKE HVAC MULTIMETER KIT
www.amazon.com.au/Fluke-FLUKE...
KLEIN (MEGGER) CONTINUITY INSULATION TESTER
(This isn’t the megger I use personally because the one I use is old and isn’t available anymore. I recommend this one because its similar and does the same thing).
www.amazon.com.au/ET600-Megoh...
VESSEL ELECTRIC SCREWDRIVER
www.amazon.com.au/VESSEL-Rech...
KLEIN CABLE STRIPPERS
www.amazon.com.au/Self-Adjust...
KNIPEX INSULATED PLIERS
www.amazon.com.au/Knipex-0208...
KNIPEX INSULATED LONG NOSE PLIERS
www.amazon.com.au/Long-Nose-P...
KNIPEX INSULATED SIDE CUTTERS
www.amazon.com.au/74-06-200-L...
KNIPEX INSULATED SCREW DRIVERS
www.amazon.com.au/dp/B092RRQT...
PENCIL
www.amazon.com.au/OX-Tools-OX...
RATCHETING RIGHT ANGLE SCREW DRIVER
www.amazon.com.au/HORUSDY-23-...

Пікірлер: 19

  • @jacksimpsonmusic
    @jacksimpsonmusic9 ай бұрын

    This was in my suggested videos. No idea who you are, but I thought I’d leave a comment for the algorithm. Have a good one, boss 😊

  • @maracservices

    @maracservices

    9 ай бұрын

    Thanks mate, appreciate it!

  • @fifis101
    @fifis1016 ай бұрын

    I've had a UF-02 error come up a few times. The unit seems to be running well (cooling as expected) then the unit shuts down and the wall remote starts flashing the error. It's been a little intermittent and acknowledging the error and turning it back on seems to fix it. Do I need to have the error in place (remote flashing) to make a proper diagnosis?

  • @jixia676
    @jixia6769 ай бұрын

    Hi, Mitch. How to check if the EEV is seized or not if electrically fine.

  • @maracservices

    @maracservices

    9 ай бұрын

    You need to buy an eev magnet. You take the coil off and out the magnet on and spin the magnet and you should feel resistance as you turn it. You can open and close it all the way. If you open it and put it back in and if you still have a restriction then the restriction is probably something else down the line. not the eev Also with the Daikin app, you can see the pulse of the eev motor. That’s handy to know sometimes.

  • @jixia676

    @jixia676

    9 ай бұрын

    @@maracservices Thankyou so much

  • @maxd4968
    @maxd49689 ай бұрын

    What’s with the different grill on the outdoor

  • @yassinaazouze8445
    @yassinaazouze84459 ай бұрын

    Those interconnects all being white are spinning me out, like how would you know which is for which, am I missing something 😂

  • @maracservices

    @maracservices

    9 ай бұрын

    Haha each white cable is labeled “one” “two” “three” etc. It’s printed in small black writing that you can see up close but not on camera 😂

  • @yassinaazouze8445

    @yassinaazouze8445

    9 ай бұрын

    @@maracservices I knew there had to be something like that😂

  • @Andrew-tt1fu
    @Andrew-tt1fu9 ай бұрын

    Why is the main PCB failed?

  • @maracservices

    @maracservices

    9 ай бұрын

    I don’t know the exact reason why it failed. All I know is it does not work correctly. I’d guess it was a power surge.

  • @SharonTan-rb3xk
    @SharonTan-rb3xk9 ай бұрын

    That grille looks bad compared to the normal one

  • @andrewl8392
    @andrewl8392Ай бұрын

    What's your business name? I am based in Sydney and looking to fix this error

  • @maracservices

    @maracservices

    Ай бұрын

    Marac Services Pty Ltd If you send me an email to the following email address, I’ll send you my availability. Cheers mitchattwood@maracservices.com.au

  • @Quangtrungvlogs68
    @Quangtrungvlogs689 ай бұрын

    Ok

  • @maracservices
    @maracservices9 ай бұрын

    Who knows mate, I guess the installers were trying to be fancy 🤷🏼‍♂️

  • @jimmyteesahn
    @jimmyteesahn9 ай бұрын

    Its climb proof because its on a balcony

  • @maracservices

    @maracservices

    9 ай бұрын

    Ah yep that makes sense