Diagnosing Daikin E5 Error

HVAC⎪HVACR⎪REFRIGERATION VIDEOS
In this video I diagnose what's wrong with a Daikin Air Conditioner displaying an E5 fault code.
Marac Services Pty Ltd
Located in Sydney.

Пікірлер: 40

  • @user-og6hm2fv4n
    @user-og6hm2fv4n23 күн бұрын

    Love the videos Mitch. Learning a lot, thank you. Keep them coming please 👍

  • @maracservices

    @maracservices

    22 күн бұрын

    Thanks mate. I think you will like the next one then. Cheers

  • @user-og6hm2fv4n

    @user-og6hm2fv4n

    22 күн бұрын

    @@maracservices Can’t wait to see it. Big fan from the UK.

  • @jamesmccann8896
    @jamesmccann889619 күн бұрын

    @maracservices Hey mate! The 7 on the remote is actually a T for test! With an e5 fault the high chance of compressor seizure with your failed board, good call with the condemn of unit Would have been good to see if you had a strong insulation resistance reading or not

  • @MagandRocky
    @MagandRocky25 күн бұрын

    The two screws floating around in the bottom of the board enclosure are meant to attach the heatsink to the board along with thermal paste, if the screws aren't installed and new paste wasn't applied that replacement board never had a chance.

  • @J.k313

    @J.k313

    25 күн бұрын

    The top right screw had seat sink on the threads. How the previous tech didn't see that is wild

  • @maracservices

    @maracservices

    24 күн бұрын

    As soon as I saw those screws I knew exactly where they were from. Like you said, they’re the ones that screw the board down to the heatsink. You make a good point about the thermal paste, there is a good chance it wasn’t applied and even if it was, it probably isn’t a good contact. I replaced that unit today so I actually have this old unit in the back of my van as we speak so I can see if thermal paste was applied.

  • @maracservices

    @maracservices

    24 күн бұрын

    @@J.k313 crazy stuff!

  • @chetmyers7041

    @chetmyers7041

    16 күн бұрын

    @@maracservices Please give us a report on the thermal paste.

  • @robalexander7348
    @robalexander734825 күн бұрын

    A interesting fault Mitchell, i look forward to the next episode 🤔

  • @kamalhamdi6739
    @kamalhamdi673921 күн бұрын

    شكرا على المعلومات القيمة والشروحات خالد من المغرب الدار البيضاء متعلم مبتدىء

  • @craigladewig3158
    @craigladewig315824 күн бұрын

    Friday also had an RX50 with E5 error code - no refrigerant in system, windings measured fine - compressor had seized.

  • @craigladewig3158

    @craigladewig3158

    24 күн бұрын

    RX50's are just unreliable -

  • @craigladewig3158
    @craigladewig315824 күн бұрын

    Problem with this scenario , you now quote client on new inverter PCB because compressor windings measured good. Client gives go ahead for new inverter PCB. You install new PCB only to find compressor has seized. Now Daikin wont return the PCB as it has been installed and client has to fork out the cash for compressor. At this stage it would have probably been more cost effective to install new unit with 1 year warranty. I always quote replacement of compressor + inverter PCB vs new unit.

  • @maracservices

    @maracservices

    22 күн бұрын

    I get what you’re saying. You’ll be happy to know I replaced the entire unit on the Saturday just past.

  • @dalebaker1529

    @dalebaker1529

    22 күн бұрын

    I would do the same thing Craig You never get any thanks from anyone by faulting the pcb then ordering them come back to replace the part to find out it’s another part that’s in fault also Would always advise to replace the whole outdoor unit which comes with warranty

  • @glenjones4404

    @glenjones4404

    19 күн бұрын

    Very true with all inverter compressors as damned if you do damned if you don't its a proper catch scenario I would quote for new out door as long as you can get the outdoor as they change to a new aircon model so then it's a new whole install and like he said it looks like it's had a new board in it's past or someone has been looking at it !!! I prefer working on refrigeration to be fair and only installing air-conditioning because even advice off Daikin and they say it's the board but it could be the inverter compressor wtf as you have to tell the customer ffs which doesn't sound reassuring 🤬

  • @jixia676
    @jixia67625 күн бұрын

    Hi, Mitch. Have you seen a faulty inverter board and a seized compressor at the same time?

  • @maracservices

    @maracservices

    24 күн бұрын

    I have not, only one or the other to be honest .

  • @technicsortechniques6373
    @technicsortechniques637321 күн бұрын

    appareil photo e5 mechanical compressor lock possible to turn off the device is closed electrical switch in off mode in more than 6 hours after turning on your device it was working. 

  • @jimmyteesahn
    @jimmyteesahn25 күн бұрын

    Is that a daikin specific inverter checker? I have a refco brand, not sure on its compatability with different brand units though.

  • @maracservices

    @maracservices

    24 күн бұрын

    It’s all good, yours will work with everything. I bought mine from Daikin but they’re all the same. Mine doesn’t have any branding on it.

  • @craigladewig3158

    @craigladewig3158

    24 күн бұрын

    I have Refco checker and works fine

  • @GeneralAvitation
    @GeneralAvitation25 күн бұрын

    its nice to see an old girl every now and then. Whats the difference between the FTXS60FVMA and FTXS60GVMA i Have both and for the life of me i can't tell.

  • @maracservices

    @maracservices

    24 күн бұрын

    They’re the same just manufactured at different times. I can confirm they have the same cover and evaporator and I assume everything else is identical.

  • @GeneralAvitation

    @GeneralAvitation

    24 күн бұрын

    @@maracservices yeah the only notice that the outdoor unit has a different Daikin inverter logo it took me a while to notice

  • @maxd4968

    @maxd4968

    20 күн бұрын

    @@GeneralAvitation I have a ftxs60bvma and it is quite different to this

  • @GeneralAvitation

    @GeneralAvitation

    20 күн бұрын

    @@maxd4968 yeah the bvma and jvea was made way earlier than these they were one of the first types if daikin inverters they were replaced to fix the bad inverter design and the fact that most of them still used r22

  • @Ahsan-zh2ou
    @Ahsan-zh2ou24 күн бұрын

    Hi Mitch, how many years is warranty for changing parts.pcb board etc

  • @maracservices

    @maracservices

    24 күн бұрын

    I honesty don’t know what the manufacturers warranty is. A lot of manufacturers don’t warrant it once the packet is opened and I’m not even kidding haha. I think they’re covering themselves from hacks incorrectly installing parts and incorrect diagnosing. That’s not the consumers issue though because if the part doesn’t work from incorrect diagnosis then the air con repairer will wear that. So it’s important for the repairer to be pretty confident before buying parts. I think most air conditioning companies give 12 months warranty on their work.

  • @craigladewig3158

    @craigladewig3158

    24 күн бұрын

    @@maracservices I don't do warranty on inverter boards unless the supplier does warranty

  • @ameernoureddine5244
    @ameernoureddine524424 күн бұрын

    Hey Mitch how do we get one of those tools?

  • @maracservices

    @maracservices

    24 күн бұрын

    I bought mine from Daikin however you can buy them online. Just search inverter checker. 👍🏻

  • @dalebaker1529
    @dalebaker152922 күн бұрын

    Daikin’s will keep you in a job for life Over priced units ,the quality has gone down hill massively in the last 15 years Would always advise my customers to go Mitsubishi electric

  • @richardbartlett6932
    @richardbartlett693221 күн бұрын

    just swap out the outdoor unit. This board swapping is the road to hell. I've got a 2016 12.5kw unit with a bad board and I won't just swap boards. Its new condenser or nothing from me.. Been bitten too many times by Daikin to play those games. Esp when the price of parts+ time+ no warranty fitting matches the cost of a new outdoor unit with warranty.

  • @maracservices

    @maracservices

    21 күн бұрын

    @@richardbartlett6932 I have a genuine question, where do you get an outdoor unit for older models? I’d love to change the whole outdoor. That would be amazing, just as far as I knew that wasn’t an option. Daikin only stock current models (as far as I’m aware).

  • @lokmangoksal7970
    @lokmangoksal797023 күн бұрын

    Dostum tesekkrler meslektasiz turkiyeden yaziyirum videolarini turkce alt yazi yaparsan iyi olur

  • @user-gk2ck4pr4g
    @user-gk2ck4pr4g24 күн бұрын

    In the case of Japan, only certain people can get checkers. So I connected three analog testers in parallel and made an original checker😂

  • @USA-GreedyMenOfNoIntegrity
    @USA-GreedyMenOfNoIntegrity24 күн бұрын

    You know you have a low quality units when the data plate is a label and is peeling off at 10 yrs…all units nowadays. Did you check communication? Install surge protector.

  • @maracservices

    @maracservices

    22 күн бұрын

    This unit was definitely over 15 years old. I couldn’t check for communication because the outdoor board was dead. I replaced the entire unit on Saturday