Data logging for Automotive and heavy equipment

Пікірлер: 21

  • @DJ-tn7vj
    @DJ-tn7vj Жыл бұрын

    Hi Mr Steve. Just made one of these shunt for my scope last week and add it as a custom probe. Excellent idea using data logging. Thanks for the breakdown

  • @markferraro5250
    @markferraro52504 ай бұрын

    Thanks STEVE for this gem

  • @lewisthomas8260
    @lewisthomas8260 Жыл бұрын

    Very informative steve many thanks, expert demonstration of the software and the hardware setup, keep up the videos they help us all

  • @Tony-rl2fr
    @Tony-rl2fr Жыл бұрын

    Brilliant. Thank you!

  • @annacersongor8553
    @annacersongor8553 Жыл бұрын

    Very informative tutorial, thanks for sharing.

  • @ELEISONCARABALLO
    @ELEISONCARABALLO Жыл бұрын

    Very interesting. Thanks for sharing👍

  • @MickClarkeSouthAfrica
    @MickClarkeSouthAfrica Жыл бұрын

    Awesome!

  • @overload3996
    @overload3996 Жыл бұрын

    Would be great 2 channels on shunt, and 2 channels on BUS with alarm on shunt to know which module is waking ,etc.

  • @mike-yp1uk
    @mike-yp1uk11 ай бұрын

    The pico support is awesome 👍

  • @edwardboers2269
    @edwardboers2269 Жыл бұрын

    nice feature.. i hope to try it out soon

  • @niallseddon8657
    @niallseddon8657 Жыл бұрын

    Hi Steve experimenting already, but having issue with alarm, (testing lithium battery) have set lower threshold at 3700mv upper at 3900mv voltage running at 3800mv, alarm is on continuously?

  • @juergenscholl2843
    @juergenscholl2843 Жыл бұрын

    Thank you for this video. One question: around 5.30 when setting up the formula for the math channel how come that mV divided by 1000 results in volt and not in microvolts?

  • @stevesmith4724

    @stevesmith4724

    Жыл бұрын

    Hello Juergen, thank you for the inquiry. In the example at 5:30 we have (Input mV / 1000) to obtain volts. For example (1000 mv / 1000) = 1 V We then divide this value by 0.1 (resistance) to obtain Current (Amps) I hope this helps. Take care......Steve

  • @soranghafour
    @soranghafour Жыл бұрын

    interesting new feature , how do you set up data logging ? as when you open picoscope on pc .thanks for sharing

  • @leesharp9646
    @leesharp9646 Жыл бұрын

    Great info well presented thanks, can we use our old 4425 with the 4425A for the 2 scopes option then, I knew I kept it for a reason

  • @benmartins6283

    @benmartins6283

    Жыл бұрын

    Yep, pretty much all of the Picoscope range of Oscilloscopes can be used with PicoLog.

  • @stevesmith4724

    @stevesmith4724

    Жыл бұрын

    Hello and thank you for the inquiry. Yes you can as both scopes can be connected to PicoLog at the same time to increase your channel count to 8 and beyond if necessary. Outside of PicoLog both these scopes are of immense value either with PicoScope 7 Automotive and or PicoDiagnostics

  • @thepiemaan7151
    @thepiemaan7151 Жыл бұрын

    Boss

  • @shaunsautorepairs5410
    @shaunsautorepairs5410 Жыл бұрын

    Hi Steve, what power rating is that 0.1ohm resistor.. they vary from 10-100w

  • @jacobmrk8903

    @jacobmrk8903

    Жыл бұрын

    I guas It's a 150 watt resistor "Arcol HS150 R1"

  • @shaunsautorepairs5410

    @shaunsautorepairs5410

    Жыл бұрын

    @@jacobmrk8903 I guess that would be a good value, rated upto about 12amps current as opposed to a 10w which would be rated at under an amp

Келесі