And this is how we get the pipes CLEAN!!!!

Cleaning out 350 feet of system + spider-boom, using compressed air, blowing from street level up.

Пікірлер: 27

  • @travspumplife
    @travspumplife9 ай бұрын

    We blow out from the placing boom down to a bucket covered with plastic but before that we pump up grout so we aren’t blowing back concrete it’s grout let’s chance of rock pack or plug and easier on the equipment

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    Same here. Usually we blow into a bucket or concrete bin. Logistical challenges on this site is why it was done the less conventional way.

  • @Dysiode
    @Dysiode9 ай бұрын

    Praise The Algorithm for delivering me here, that was way more interesting than I expected! Your assistant really got into the rhythm by the end

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    He’s actually Dan’s assistant. They just let me hangout for the afternoon on this one 😁😁😁

  • @ulisesrenderos2261
    @ulisesrenderos22619 ай бұрын

    great job brother if you clean the pipes god bless you

  • @IndyJones243
    @IndyJones2439 ай бұрын

    Nice job Dan. Ready for your own channel!

  • @dannpriebe

    @dannpriebe

    9 ай бұрын

    Lol. To much work. Besides I would be way to boring.

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    He’s too busy actually pumping concrete 😂😂😂

  • @bowenike
    @bowenike9 ай бұрын

    I think a good video would be the process of explaining how a placing boom actually ends up on a tower. i.e the convos you have with the engineers/contractors before the pedestal even makes it on the building. Then that first set up of the pedestal and the boom and any testing you do before hand. side note: maybe im biased because our first placing boom job is coming up in a few months 😅

  • @user-jm7fk4go4w
    @user-jm7fk4go4w8 ай бұрын

    Привет Скотт из России, я тоже качаю от бункира трассой до 150 метров ...

  • @Bailey_and_me
    @Bailey_and_me9 ай бұрын

    Here in Ontario I've seen them pump back down into the cement mixer. Pumping line is disconnected from the pumper, changed over to upside "J" pipe with a ball catcher cage on the short "J" side and placeed into the mixer hopper opening. Is there a reason why you don't take advantage of dumping out, cleaning into the mixer? Love your channel 🤙

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    Typically we will blow back into a concrete bin. Logistical challenges at this particular site is why it’s not being blown out back to street level as per usual. Most companies here have done away with blowing back into the mixer. There were several incidents of the candy cane popping out of the mixer and causing chaos. Not saying that it’s not a good way of doing, our market just couldn’t seem to dial it in constantly/reliably. Appreciate you following the channel and taking part in the comments. That’s what it’s all about. 👌👌👌

  • @dannpriebe

    @dannpriebe

    9 ай бұрын

    I've done that on a few jobs. Much prefer just blowing through diversion valve into a rock bin though, smallest chance of issues.

  • @bowenike
    @bowenike9 ай бұрын

    “You cant just let a sponge go like that” 😂 can tell who is a owner operator and worried about bottom line 24/7 vs who is just there because they love concrete pumping/collecting a paycheck 🤣

  • @Dysiode

    @Dysiode

    9 ай бұрын

    Felt more like a curiosity than a serious concern considering he spent a token amount of time fishing for it, and was the first to say it's gone forever at 28:43 😉

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    @@Dysiode it was admittedly a rather half-asses recover effort 😂😂😂

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    @@Dysiode had it been our own site/sponge I would have gone bobb’N for apples until I found that thing!

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    Chopped sponges and lost clamp gaskets keep me up at night. True story 😁😁😁

  • @bowenike

    @bowenike

    9 ай бұрын

    @@canadianconcretepumper1979 i can live with a ball or two being chopped, but clamps & gaskets do keep me up at night

  • @pumpingconcretefamilywithe2631
    @pumpingconcretefamilywithe26319 ай бұрын

    🎉🎉🎉🎉🎉🎉 excelente

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    Thank you my brother 🙏🙏🙏

  • @Mk99987
    @Mk999879 ай бұрын

    Is the beginning of the video missing?

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    Negative. Just the way we wound up piecing it all together. We had originally filmed this all (top and bottom) on the same day, but came to find out that our camera on the bottom was set to time-lapse mode (doh!!!!), so Dan filmed the bottom again on a separate day and we pieced it all together as best we could.

  • @travspumplife
    @travspumplife9 ай бұрын

    Get a Diversion valve Dan stop banging that shut off valve works right up to the hydraulics of the teuck

  • @nathancruz1099

    @nathancruz1099

    9 ай бұрын

    Fr a three way works best could wash out the pump and the whole system at the same time just back up the tree into the truck and chain the tree to the truck and have a blast no mess or no worry’s

  • @dannpriebe

    @dannpriebe

    9 ай бұрын

    We have the 3 way diversion valve on most of our jobs. Just on this one it was not logistically possible.

  • @canadianconcretepumper1979

    @canadianconcretepumper1979

    9 ай бұрын

    This hammer shutoff valve is what keeps Dan down at fighting weight 😂😂😂