Worcester NO IGNITION. Gas valve Reset/ Adjust & Fine Tune. Detailed/ Step by step, Fault Finding.
Жүктеу.....
Пікірлер: 25
@DD-eh9cp6 ай бұрын
Good presenter. Very clear presentation.
@chohanchohan820810 ай бұрын
Better than WBosch training I can assure you - thank PaaG
@BoilerMend
10 ай бұрын
Thanks. Very kind 😌
@waynetraish1895Ай бұрын
Very helpful video, explained really well and clearly 👍
@BoilerMend
Ай бұрын
Thanks 😎👍
@lucanspittle82134 ай бұрын
I had same problem However British Gas had been servicing the boiler 7 years prior. Never taken the case off. The electrodes worn out, gasket on heat cell disintegrated ! The top baffle had blown! And bottom baffle stuck ! Also reset gas valve too. Same process as yours just about adjusting gas valve to suit But we’re putting a new heat cell in next
@BoilerMend
3 ай бұрын
Unfortunately big companies don't live upto their names when it comes to standard of work. If the work is carried out according to correct procedures. Maintenance would be easy and a lot less hassle. BTW. Did you have that main hx put in?
@Carl-re6zb11 ай бұрын
Nice one Raj... Also if the adjustments on the valves don't work you need to check the bearing plate washer..
@benson161006 ай бұрын
Quality video 👍
@BoilerMend
6 ай бұрын
Thank you 🫶
@melvinevans998111 ай бұрын
Love your work as always, mate. You are one of the best on KZread I watch. Keep on making em
@martinwright709311 ай бұрын
Nice one.. had to do this a few times, keeping the burner lit on minimum can be tricky, especially on the 12 and 15KW models.
@QuransFaizan
7 ай бұрын
12 n 15kw ones can be a pain to adjust
@davidproctor6359Ай бұрын
brilliance
@BoilerMend
Ай бұрын
Thank you 👍
@jameswilson28998 ай бұрын
Great video
@BoilerMend
8 ай бұрын
Thanks 👍
@user-tp1ug8ke3m5 ай бұрын
very well explained. Well done. thanks
@BoilerMend
4 ай бұрын
Thank you 🫶
@fidamohammed937112 күн бұрын
Hi F Raj brilleant video now we know how to turn minnimum and maximum totally off and 3 and half turn and 2 and half turn for minnimum to atleast keep the boiler going Do u know how to do it with vaillant and baxi 2 which flue analyser would u recomend not happy with anton need to buy different one Thaanks
@BoilerMend
7 күн бұрын
Hi. Thanks for your kind message👍. I've tried this, on Vaillant's EcoFit pure. I'll try and make a video sometime. Haven't tried on other models or Baxi. I've mostly used Anton and worked fine for me. Have used Kane Abalyzer's older models. Does the job well but was chunky. Not sure about newer models.
@mikearthur25869 ай бұрын
Can I ask where you got the 3.5 turns and the 2.5 factory reset information from please ?
@BoilerMend
8 ай бұрын
Hi. It is in the little document, shown in the video. Time is 12min 44seconds. This document usually comes with a new gas valve for several worcester models.
@seanb-ol3up24 күн бұрын
Was at one of these today greenstar 15ri the data badge said co2 9.6%/8.6% the only manual I could find said 9.8%/9.2% so which do I go by? Any info by anyone would be greatful thanks
@BoilerMend
23 күн бұрын
Data badge is on the appliance. I would say go with that
Пікірлер: 25
Good presenter. Very clear presentation.
Better than WBosch training I can assure you - thank PaaG
@BoilerMend
10 ай бұрын
Thanks. Very kind 😌
Very helpful video, explained really well and clearly 👍
@BoilerMend
Ай бұрын
Thanks 😎👍
I had same problem However British Gas had been servicing the boiler 7 years prior. Never taken the case off. The electrodes worn out, gasket on heat cell disintegrated ! The top baffle had blown! And bottom baffle stuck ! Also reset gas valve too. Same process as yours just about adjusting gas valve to suit But we’re putting a new heat cell in next
@BoilerMend
3 ай бұрын
Unfortunately big companies don't live upto their names when it comes to standard of work. If the work is carried out according to correct procedures. Maintenance would be easy and a lot less hassle. BTW. Did you have that main hx put in?
Nice one Raj... Also if the adjustments on the valves don't work you need to check the bearing plate washer..
Quality video 👍
@BoilerMend
6 ай бұрын
Thank you 🫶
Love your work as always, mate. You are one of the best on KZread I watch. Keep on making em
Nice one.. had to do this a few times, keeping the burner lit on minimum can be tricky, especially on the 12 and 15KW models.
@QuransFaizan
7 ай бұрын
12 n 15kw ones can be a pain to adjust
brilliance
@BoilerMend
Ай бұрын
Thank you 👍
Great video
@BoilerMend
8 ай бұрын
Thanks 👍
very well explained. Well done. thanks
@BoilerMend
4 ай бұрын
Thank you 🫶
Hi F Raj brilleant video now we know how to turn minnimum and maximum totally off and 3 and half turn and 2 and half turn for minnimum to atleast keep the boiler going Do u know how to do it with vaillant and baxi 2 which flue analyser would u recomend not happy with anton need to buy different one Thaanks
@BoilerMend
7 күн бұрын
Hi. Thanks for your kind message👍. I've tried this, on Vaillant's EcoFit pure. I'll try and make a video sometime. Haven't tried on other models or Baxi. I've mostly used Anton and worked fine for me. Have used Kane Abalyzer's older models. Does the job well but was chunky. Not sure about newer models.
Can I ask where you got the 3.5 turns and the 2.5 factory reset information from please ?
@BoilerMend
8 ай бұрын
Hi. It is in the little document, shown in the video. Time is 12min 44seconds. This document usually comes with a new gas valve for several worcester models.
Was at one of these today greenstar 15ri the data badge said co2 9.6%/8.6% the only manual I could find said 9.8%/9.2% so which do I go by? Any info by anyone would be greatful thanks
@BoilerMend
23 күн бұрын
Data badge is on the appliance. I would say go with that