Wind Load Calculation on Walls | According to Eurocode | Tutorial

Ғылым және технология

Wind loads on walls are required to verify the overall stability of a building, bending of facade columns and more. In this video, we show how to calculate the wind loads on walls, step-by-step. 💨💨
👇👇JOIN OUR COMMUNITY - STRUCTURAL ENGINEERING FOR EVERYONE👇👇
Sign up to our free Substack newsletter, where we talk about structural engineering related topics.
📧📧 Sign up for free: structuralbasics.substack.com...
📱📱 BLOG
👇👇Check out our blog Structural Basics with 90+ structural engineering guides.👇👇
Blog: www.structuralbasics.com/
👇👇Dlubal Wind Calculator👇👇
www.dlubal.com/en/solutions/o...
👇👇LINKS TO RELATED CONTENT👇👇
Wind Load Calculation On Walls - Blog post: www.structuralbasics.com/wind...
Peak Velocity Pressure - Blog post: www.structuralbasics.com/peak...
Wind Load Calculation On Flat Roofs - Blog post: www.structuralbasics.com/how-...
Wind Load Calculation On Pitched Roofs - Blog post: www.structuralbasics.com/how-...

Пікірлер: 13

  • @samsokheng4488
    @samsokheng44889 ай бұрын

    Many thanks. How about h>= 2b in EN1991-1-4, Figure 7.4 there are 3 levels of qp(z). Do we need to multiply Cpe with each faces (A,B,C...) with this 3 levels of qp(z) to obtain wind load at each of these 3 levels?

  • @user-cm5gq9ls7b
    @user-cm5gq9ls7b3 ай бұрын

    Could you please show and explain how Wind loads from Eurocode applied to Open structure like Pipe Racks or Cable Racks?🤔

  • @shiderbayev
    @shiderbayev Жыл бұрын

    Thanks)

  • @structuralbasics97

    @structuralbasics97

    Жыл бұрын

    Hi, Thanks for your good feedback! Cheers, Laurin

  • @nabilkhalifa3121
    @nabilkhalifa31215 ай бұрын

    This was a really great video and so helpful for a project that I am working on right now. I was wondering, is there any guidance for how to determine internal pressure co-officiants? That's something else that confuses me. I have read the code and know that essentially its either -0.3 or +0.2. Is this all there is to it? This code is so confusing!!!

  • @structuralbasics97

    @structuralbasics97

    3 ай бұрын

    Hi Nabil, That’s a good and tricky question as internal wind pressure isn’t that easy to understand. On a project where I designed suspended ceilings I used the coefficients 0.2 and 0.3 as you mentioned. However, when you have large openings in a building like a warehouse you should use the normal coefficients on walls if not even increase them bc of the increased pressure difference.

  • @anonymouscommenter8637
    @anonymouscommenter86373 ай бұрын

    why did u take bigger value for width and smaller for length

  • @javieibarra3259
    @javieibarra3259 Жыл бұрын

    And the load should be applied to the columns or the beams ?

  • @structuralbasics97

    @structuralbasics97

    Жыл бұрын

    Hi, That depends on the structural system. It could be that the facade is designed in a way that it’s supported by the floors. In that case the facade needs to be designed to resist that wind load. I have only seen cases where the facade was connected to the floors. However, in theory, the facade elements could also be connected to the columns. Then the columns need to be verified for the wind load. In both cases, the wind load gets distributed to the floors and from there to the walls or stabilizing system. And then down to the foundation.

  • @javieibarra3259

    @javieibarra3259

    Жыл бұрын

    @@structuralbasics97 that makes sense, thank you for answering !!

  • @structuralbasics97

    @structuralbasics97

    Жыл бұрын

    Happy I could help! ✌️✌️

  • @anonymouscommenter8637
    @anonymouscommenter86374 ай бұрын

    what about for roof?

  • @structuralbasics97

    @structuralbasics97

    3 ай бұрын

    We don’t have a video on that yet, but you can check out our blog post: www.structuralbasics.com/how-to-calculate-the-wind-load-of-a-pitched-roof/