Wen 2350 generator

Тәжірибелік нұсқаулар және стиль

generator Wen high altitude jet portable trailer 2350 inverter

Пікірлер: 43

  • @mikestone9129
    @mikestone91293 жыл бұрын

    Finally an honest video from someone who isn't trying to impress us with his knowledge. I was gonna buy this today from Amazon, but now I'm not sure. I travel a lot from South Texas all the way up into the mountains. And if I have to make this adjustment each time, no way. So now I gotta learn if this is the same problem with all small generators.

  • @NotSoFast71

    @NotSoFast71

    2 жыл бұрын

    If you are referring to rejetting the carb, then yes, you have to for high altitudes. This is the case for all carbureted engines. The air is thinner up there and requires different jetting. Computer controlled fuel I jection corrects for air/fuel ratio, but carbs don't. Good luck finding a fuel injected small generator.

  • @wjefflusk
    @wjefflusk2 жыл бұрын

    Excellent product review. Good info on the High Altitude conversion. Looks like it can be a bit of a pain. I would have to switch back and forth in my situation so, thank you for adding that to your video.

  • @burromeister

    @burromeister

    2 жыл бұрын

    Thanks, I have wondered if the high altitude conversion would be trouble when camping at sea level but so far, that has never been an issue. Have no intention of ever doing a change-back.

  • @mrspin3315
    @mrspin3315 Жыл бұрын

    Being in the garage the generator is going to be louder!

  • @AppleFanX2
    @AppleFanX23 жыл бұрын

    Good video, thanks for posting it. 👍🏻

  • @solden49
    @solden493 жыл бұрын

    Good video sir

  • @burromeister
    @burromeister Жыл бұрын

    I sent an email to WEN to complain about my 2350W generator failing to run my air conditioner. It took a few weeks for them to answer. I bought the Honda. But anyway, they finally responded. First they answered: “Make sure the oil is coming halfway up the crankcase threads…if oil is fine, try bypassing the sensor…follow the wire from the part where it is imbedded in the crankcase to the connector - disconnect the connector… or it could be a fuel or air flow issue…or a vacuum relief valve… or check the spark plug.. etc. ” That was totally useless advice. I removed a side panel but there was no way to identify or find that yellow wire or access the crankcase and do what they wanted me to try. I replied as much. Their other suggestions simply were not relevant. I said so. A few more weeks passed. They then replied: “…I think a 11000 btu AC maybe a little too much for model 56235i, the generator can only produce 1900 rated watts…” End of story. Did I mention I bought the Honda?

  • @josephleister9198
    @josephleister91983 жыл бұрын

    Nice video...thank you for posting your exploits...

  • @RHEC1776
    @RHEC17763 жыл бұрын

    You can take the ethanol out of the gas yourself. Super easy. I do it all the time

  • @rogerdayton
    @rogerdayton4 жыл бұрын

    Manual says runtime is 5.7 hours at half-load for the 56235i. Their website says 10.5 hours on a quarter load. Which doesn't make sense. Contacted Wen and they said the 10.5 hours runtime at a quart-load is correct. So I ordered one from them, supposed to be delivered next week. Hope it's correct or I will return it. I have a 5k BTU AC that is only 410 watts and want to get the highest runtime possible.

  • @rickbraden4272

    @rickbraden4272

    3 жыл бұрын

    Don't forget you can probably find an extended run gas gap & tank. Then you'll have over 24 hours like I do on my Honda eu2000i.

  • @joenanes1891
    @joenanes18912 жыл бұрын

    I have the smaller Wen 2000. I run it in Texas and it will run a 5k window unit with no problems. I went on vacation up to South Dakota this August then to Yellowstone park and ended up staying in between yellowstone South and Grand Tetons in a parking lot by a campground. I ran my generator to recharge my Bluetti so I can continue to run my 12v fridge. I didn't notice any difference in the way the generator ran. I did not run an AC unit so it didn't have as much load as it would in Texas . Have you tried it without the elevation kit to see how it runs ?

  • @burromeister

    @burromeister

    2 жыл бұрын

    No. Since my home is at 6700 feet elevation I ordered the high elevation kit before even first adding fuel to it. Have never yet run the thing at below 5000 feet but changing the jet back is likely something I will never do.

  • @robertsm4341
    @robertsm43412 жыл бұрын

    LOUD!!!!!

  • @pjfsr7024
    @pjfsr70243 жыл бұрын

    Need a much longer ground rod from what I see. If this is also being used for the home, the rod should be 6-10 feet long.

  • @burromeister

    @burromeister

    3 жыл бұрын

    Seriously?

  • @pjfsr7024

    @pjfsr7024

    3 жыл бұрын

    @@burromeister yes!

  • @tonisam962

    @tonisam962

    3 жыл бұрын

    Make sure you watch this generator safety video kzread.info/dash/bejne/e2WetpV6fqi0pqw.html it’s a very important advice for everyone to know about. Thank you

  • @kennygeee6750

    @kennygeee6750

    3 жыл бұрын

    Does this grounding rod need to be copper?

  • @pjfsr7024

    @pjfsr7024

    3 жыл бұрын

    @@kennygeee6750 Yes, can get them at HD I believe.

  • @Zoobamafoo
    @Zoobamafoo2 жыл бұрын

    Is that the "super quiet" model? It's as loud as the giant generator my next door neighbor had used after a hurricane & the power was out for 9 days! Good grief, I can't have one that loud where I'm at right now.

  • @burromeister

    @burromeister

    2 жыл бұрын

    Did a homeboy loudness check of my Wen using a db ap on my phone. I'm no sound technician but My phone spoke to me and -- At 2 ft from the phone me talking normally registered 63-67 db. At 6 ft from the Wen running on eco mode it registered between 66 to 70 DB, and at 25 ft from the generator on eco it was 76-80 DB. With the eco mode off, at 25 ft it registered 82 DB. My guess is your neighbor's giant generator blows my little Wen right out of the water.

  • @kennygeee6750
    @kennygeee67503 жыл бұрын

    Where can I get this high altitude kit? Can you please copy and paste a link for me? Also I will be going to my nearest home depot to find myself the 8 gauge stranded copper grounding wire. How long does that need to be and is there waterproof ones? What are the specifications for the grounding rod and how do I ask for that at home depot? This is my first time buying one and I want to make sure everything is right.

  • @burromeister

    @burromeister

    2 жыл бұрын

    Contact Wen on line. Wire 3-4 feet should be just fine depending on your preferred distance from the gen. My rod was simply a short length of 1/2inch re-bar from home depot.

  • @thelightworshipper9687
    @thelightworshipper96873 жыл бұрын

    Could not find information on the jet orifice size compared to stock. Is it smaller or larger? I assume with less oxygen you want less fuel. So i will assume the high altitude jet have a smaller orifice. So a smaller orifice will it make the generator run longer on a gas tank than stock? Of course it will not generate the same amount of watts (loss of performance).

  • @burromeister

    @burromeister

    3 жыл бұрын

    It probably does have a smaller orifice but I never bothered to compare the two. Never ran it with the factory jet. All I know is with the jet changed the WEN works great at high altitudes here. As far as gas consumption improvement or not, I see it as hardly something of measurable significance.

  • @kennygeee6750

    @kennygeee6750

    3 жыл бұрын

    Please send me a link for where to find this item. I may have to install this myself. Also can you ground a machine like this on a beach?

  • @burromeister

    @burromeister

    3 жыл бұрын

    @@kennygeee6750 Never beached it but seems to me grounded anywhere would be fine. Don't have a link but just Google Wen -visit their website and ask them for Wen high altitude carb jet, part #56235I-HA69.

  • @danniecarmona2509
    @danniecarmona25094 жыл бұрын

    Thats loader than a lawn mower

  • @rogerdayton

    @rogerdayton

    4 жыл бұрын

    Generators always sound loader than they are in a video.

  • @pjfsr7024
    @pjfsr70243 жыл бұрын

    Just add stabilizer to the 5% ethanol gas. You can go buy 20$ pure gas frome HD or Lowes.

  • @burromeister

    @burromeister

    3 жыл бұрын

    No thank you. I saw that gas at Lowes. Maverick stations sells ethanol free gas for $2.30/gallon.

  • @pjf7943
    @pjf79433 жыл бұрын

    Make sure you aim the hot exhaust at the gas can...!!! Then you'll REALLY see "lift off".... LOL! Hopefully, you aren't over 65.... You'll give us seniors a bad name....

  • @burromeister

    @burromeister

    3 жыл бұрын

    My bad. I should have mentioned that test run in the video was strictly for the video sound test and, WEN only ran the couple minutes it took to record the test there in the garage. (A geezer mistake - me being 77.)

  • @pjf7943

    @pjf7943

    3 жыл бұрын

    @@burromeister I'm not that far behind you at 73..!! LOL! BTW, about 45 min. ago, I went to the WEN site and purchased the 56380i 3800/3400 for $619 w/free shipping ($733 at Amazon + tax) . I did that after seeing the Harbor freight increased their gennies another $50 w/in six months and knowing that all the other gennies will be raising their prices too.. In truth I was going to buy the 56235i 2350/1900 because it weighed less and I really don't need all the power of the other.. But, what the hell..!! LOL! Take care..

  • @artest7
    @artest72 жыл бұрын

    Can i just ground my WEN 2350 to my Cargo trailer instead of driving it into the ground?

  • @burromeister

    @burromeister

    2 жыл бұрын

    I have no idea.

  • @000MACK000
    @000MACK0003 жыл бұрын

    I don't see any difference in the size of screws they look identical what's so special about it that it's for high-elevation sounds like a scam to me.

  • @burromeister

    @burromeister

    3 жыл бұрын

    What scam? I have no idea what you're talking about.

  • @pjfsr7024

    @pjfsr7024

    3 жыл бұрын

    One of my wens 4750 came with HA kit in a small package, I don't think it's a scam,human eye may not see the difference, but the generator will.

  • @robertm8204
    @robertm82043 жыл бұрын

    1) The Genny is being run with the exhaust aimed at the left interior wall of the garage, essentially filling up the garage with DEADLY Carbon Monoxide!! NOT good and it shows a very dangerous error that may be continued overnight!! The 4 people killed by running generators during hurricane Laura just days ago should have headed the bold warnings in their Owners Manuals. Watching the main jet being clumsily changed makes me wonder if we were meant to see a novice R&R operation, especially when the fuel valve was NOT turned ON to check for leaks/weeps BEFORE the outer cover was screwed on. The float bowl drain screw also points directly at the ignition coil, blocking screwdriver access. I say this because portable generators are not for everybody in that there can be expensive mistakes made by the uninformed -like- using a 100 feet of 16Ga extension cord(S) to power a refrigerator and coffee pot where the voltage drop caused current rise will certainly damage the inverter and/or the refrigerator's compressor motor. 2) The main jet "size" refers to the replacement jet's tiny axial fuel metering hole that is smaller in diameter by just a few thousandths of an inch to obtain the leaner "on-load" fuel mixture needed for the thinner air at higher altitudes . . . so you wouldn't "see" the difference. 3) I have the 56200i 2KW Genny with 24 hours on it and it's marvelous during power outages, running our 21cu-ft Energy Star refrigerator and 6cu-ft chest freezer plus TV/SatDish and LED lights! (Started in the correct order).

  • @burromeister

    @burromeister

    3 жыл бұрын

    Plus, I was told the grounding rod should be 6 to 10 feet into the ground. Yeah, he loudly asked me, "...well, with all that, are you feeling lucky, punk?"