Top 10 Circulator Pump Problems Found on Boilers!

10 Problems that Occur in Boilers that are the Circulator Pump or a Related Problem that the Circulator is Blamed for. I Discuss and Show Noise, Troubleshooting, Leaking Water, Bearings Locked, Testing the Motors, Capacitors, Air Locks, and Processes. Supervision is needed by a licensed HVACR Tech while doing this as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video
UEI DL479 Multimeter With Temp Sensor amzn.to/2jtsUbJ
Alligator Jumpers- amzn.to/2PxqJXn
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos
• Taco Zone Valve Relay ...
ttps:// • 4 Wire, 5 Wire Honeywe...
• Taco Zone Valve Wiring...
• Testing, Wiring, Taco ...
• Taco 6 ZONE Switching ...
• Installation of a Tank...
• Boiler Training Class,...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #hvacproblems #boiler #circulator #noise #troubleshooting #leaks #motor #testing #capacitors #airlocks
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 117

  • @acservicetechchannel
    @acservicetechchannel5 жыл бұрын

    Support- www.patreon.com/acservicetech Tool List- www.amazon.com/shop/acservicetech For those that are looking for the tools used in the videos: (Linked Below) UEI DL479 Multimeter with temp sensor amzn.to/2jtsUbJ Valve Core Removal Tool amzn.to/2uYr8WL Blue Vapor Yellow Jacket Gauge- amzn.to/2Ju7pan Red Liquid Yellow Jacket Gauge- amzn.to/2sSFmGH Quick Coupler for the Gauges- amzn.to/2sTk8Ze JB Test Gauge High Side- amzn.to/2ruQb0l JB Test Gauge Low Side- amzn.to/2qR0utM Manual Copper Tube Swage/Expander- amzn.to/2WRPa1M Uniweld Hydraulic Swaging Tool- amzn.to/2MlrI8m Uniweld Swage and Flare Kit- amzn.to/2T55jyn Ameriflame Oxy Acetylene Torch Setup- amzn.to/2SRm3JF #2 Tip for Oxy Acetylene Torch- amzn.to/2SPDaeD Cap-N-Hook Tip for Oxy Acetylene- amzn.to/2MbhpUk Air Acetylene Torch Setup- amzn.to/2aQalsb 15% Silver Brazing Rods- amzn.to/2gVLyLc Nitrogen Regulator- amzn.to/2bXdR5f Nitrogen Flow Meter- amzn.to/2brvoBg NitroVue Flow Reg- amzn.to/2MiulYv Ultrasonic Leak Detector- amzn.to/2Lw4Zpr UEI DL479 Multimeter with temp sensor amzn.to/2jtsUbJ Magnet Jumpers- amzn.to/2PyKPQZ Alligator Jumpers- amzn.to/2PxqJXn Fieldpiece ST4 Dual Temp Meter amzn.to/2wc1ME3 Fieldpiece Bead K Type Temp Sensor amzn.to/2DBwKfs Fieldpiece Wet Bulb Temp Sensor amzn.to/2RRI7Tw Fieldpiece TC24 Temp Clamp amzn.to/2qHLyjZ Yellow Jacket Refrigerant Gauge Set amzn.to/2aenwTq Refrigerant hoses with valves amzn.to/2aBumVI Yellow Jacket Gauge set & hoses amzn.to/2vLVkV9 Yellow Jacket 4 Port Manifold w Hoses amzn.to/2BkuGIq FieldpieceSMAN360 Digital Manifold Set amzn.to/2BdoaD4 FieldpieceSMAN460 Digital Manifold Set amzn.to/2nB4Fe6 Compact Ball Valve for Refrigerant Hose amzn.to/2KUisW8 QuickDisconnect 90 for refrigerant hose amzn.to/2MMtVcg JB 6 CFM Vacuum Pump amzn.to/2nqbvo8 Appion Blue 3/8" to 1/4" Vacuum Hose amzn.to/2uYlVyc Appion Red 3/8" to 1/4" Vacuum Hose amzn.to/2uYg6Ro Appion Valve Core Removal Tool amzn.to/2uYr8WL Yellow Jacket 1/4" by 1/4" hose amzn.to/2umtcod CPS Vacuum Micron Gauge amzn.to/2v1nM3O Supco Vacuum Micron Gauge amzn.to/2v1JRiA RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn UEI DL389 Multimeter amzn.to/2xAdaJf Other tool links can be found in the video description section. Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal- www.amazon.com/shop/acservicetech

  • @derrickherndon9993
    @derrickherndon99932 жыл бұрын

    This was so incredibly helpful. Very thorough and clear. Last year I had an impeller that was stuck. Manually turned it to free it. This year it was a sticky relay (problem #6). Thought at first it was air in the lines as I turn off water to that heater in the summer so that hot water is not always providing a heat source in that room. Drained the line but no joy. Pump not running but impeller turning was the hint. I just tapped the relay after removing the cover and the pump engaged. Will see if the relay returns to normal switching. This is a Grundfos pump with the access port as shown above. Thank you so much for helping us DIY home owners.

  • @danielbaldwin8260
    @danielbaldwin82603 жыл бұрын

    Excellent diagnostic and repair presentation. I was able to get major air pockets removed by the fill and bleed method and provide heat to the upstairs apartment. Thanks for saving me money, time, and wasted efforts.

  • @luiselizalde6757
    @luiselizalde67575 жыл бұрын

    As always, very good quality videos, I really appreciate them. Thanks teacher. Keep making those videos.

  • @acservicetechchannel

    @acservicetechchannel

    5 жыл бұрын

    Glad to help Luis!

  • @lalac6095
    @lalac60954 жыл бұрын

    Thank you for this. You just kept me from having to get up every hour and switch zones for my heat ;) bled the line and it works like a charm. ❤️

  • @acservicetechchannel

    @acservicetechchannel

    4 жыл бұрын

    Thanks for letting me know!

  • @catherinewalpole6392
    @catherinewalpole63922 жыл бұрын

    This video is comprehensive and easy to understand. Thank you!

  • @jfmc2581
    @jfmc25812 жыл бұрын

    Great video, you covered lots of issues clearly and quickly.

  • @mikeallen2097
    @mikeallen20972 жыл бұрын

    Great video. Excellent information. Thank you very much for posting! Looking forward to more.

  • @jashua2089
    @jashua20892 жыл бұрын

    Amazing information, keep up the good work master.

  • @crooktube
    @crooktube5 ай бұрын

    Great video! I ended up buying a new one, but with this video I had the confidence to do it myself and that saved me so much money and maybe even saved me from a new boiler this year! Just got quoted for a new boiler.... $20K!!! Cheers!

  • @Stil1_loading

    @Stil1_loading

    4 ай бұрын

    what was he replacing radiators too?

  • @richardcaro3368
    @richardcaro33684 жыл бұрын

    Thank you so much I learn so much from your videos keep up the great work

  • @acservicetechchannel

    @acservicetechchannel

    4 жыл бұрын

    Thank you for your support!!

  • @jackjenkins6305
    @jackjenkins63053 жыл бұрын

    Really enjoyed your video/s. you are a great instructor, so keep up the good work!

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    I appreciate that!

  • @integrity5264
    @integrity52643 жыл бұрын

    you covered everything, thank you, well done

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    Glad you enjoyed it!

  • @Unknown-qt9cv
    @Unknown-qt9cv9 ай бұрын

    Thank you so much. Amazing explanations and demonstrations. VERY helpful

  • @Nokyai
    @Nokyai Жыл бұрын

    Excellent video and clear explanation! Thank you very much!

  • @tongyang1631
    @tongyang1631 Жыл бұрын

    thank you so much for all the tips. I'm a handy man but my expertise is in automobiles and carpentry. this probably saves me hundreds of dollars on my first personal diagnosis. I don't have a fill valve but I do have two valves that fit a garden hose. One after the circulator and one on the bottom. I will try to fill it. last year it worked well but I could hear air in my system. thank you for giving me a chance at messing with it. something so simple but I just couldn't figure how to fill without a valve

  • @kevinkamel3158
    @kevinkamel315810 ай бұрын

    Great presentation. Thank you so much for taking the time to create videos like this.

  • @acservicetechchannel

    @acservicetechchannel

    10 ай бұрын

    Glad it was helpful!

  • @stephenalibozek1058
    @stephenalibozek10583 жыл бұрын

    Very good explanation of how to search for the problem 👍👍

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    Glad it helped

  • @lesio333
    @lesio3334 жыл бұрын

    Very detailed and educational video, thanks :)

  • @acservicetechchannel

    @acservicetechchannel

    4 жыл бұрын

    Glad it was helpful!

  • @rinamackeeman4376
    @rinamackeeman43765 ай бұрын

    Really great video. You’re a good teacher

  • @jimmittler6344
    @jimmittler63448 ай бұрын

    Excellent, thank you for covering everything

  • @acservicetechchannel

    @acservicetechchannel

    8 ай бұрын

    My pleasure!

  • @shinylight7705
    @shinylight77052 жыл бұрын

    Thanks for the video

  • @carlblack8900
    @carlblack89005 жыл бұрын

    Another awesome video!

  • @acservicetechchannel

    @acservicetechchannel

    5 жыл бұрын

    Thanks a lot Carl!

  • @leodavis7524
    @leodavis75242 жыл бұрын

    Very well explained 👍

  • @heatncool
    @heatncool5 жыл бұрын

    good video. nice! I've devoured your videos for the last year doing residential but since I got into commercial hvac, im working with boilers, cooling towers, vav boxes, water cooled condensers, chillers. Good video thnx!

  • @acservicetechchannel

    @acservicetechchannel

    5 жыл бұрын

    Got ya, that's awesome Daniel, great to hear!

  • @TheSincere20000

    @TheSincere20000

    5 жыл бұрын

    Who do you watch for commercial?

  • @kenwiltshire7834
    @kenwiltshire78343 жыл бұрын

    Fantastic, Thanks so much.

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    Glad you enjoyed it!

  • @williambauer9259
    @williambauer92593 жыл бұрын

    You are amazing. Thank you so much!

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    Glad to help Will and check out our website at www.acservicetech.com thanks!

  • @manismello
    @manismello3 жыл бұрын

    You’re very welcome...I’ll keep In touch!

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    Thanks!

  • @micharris1761
    @micharris1761 Жыл бұрын

    nice video ty for it.

  • @manismello
    @manismello3 жыл бұрын

    Very good job, sir, 👍

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    Many thanks

  • @ThePachucoMix
    @ThePachucoMix Жыл бұрын

    Thanks 🙏 I need more videos of Boilers

  • @Wiggles1
    @Wiggles13 ай бұрын

    Just SUPERB 😀

  • @juliorodriguez8863
    @juliorodriguez8863 Жыл бұрын

    Thanks!

  • @hdavey72
    @hdavey723 жыл бұрын

    Good stuff

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    Glad you enjoyed

  • @YTsux24-7
    @YTsux24-75 жыл бұрын

    Good stuff as always sir!

  • @acservicetechchannel

    @acservicetechchannel

    5 жыл бұрын

    Thanks Tomon8tor!

  • @yoman5136
    @yoman51364 жыл бұрын

    When my unit, four zones, was built two guys did the work. Looking at the first thing the B team guy did, I told the A team guy that I’m going to have to look at this system for a long long time. So the A team guy sent b guy off doing other stuff. A guy built a great four zone manifold system that was, “Instrument Fitter” quality work, perfectly plumb and level and square. . The B team guy soldered pipes out in the zone manifolds and used an old worn wire brush cleaning the insides of the copper pipes. We ended up opening the system at the pumps taking out broken wires from an old worn out soldering brush the dummy brought with him !

  • @josepeixoto3384

    @josepeixoto3384

    Жыл бұрын

    oops!

  • @michaelthompson7528
    @michaelthompson75282 жыл бұрын

    He just saved me some money. My pump was the red pump. Went into the basement and oiled it in all three ports. NO MORE noise.

  • @Stil1_loading

    @Stil1_loading

    4 ай бұрын

    what oil

  • @PBS-nm1uu
    @PBS-nm1uu5 жыл бұрын

    just found this video just keep them coming, do you have any on radiant heating ??

  • @acservicetechchannel

    @acservicetechchannel

    5 жыл бұрын

    Thank you, just on controls such as zone valves, aquastat, zone control relay, thanks!

  • @dpalexander
    @dpalexander2 жыл бұрын

    Very nice! Wondering if you have encountered a pulsing in the pump (primary), frequency approx 10 times per second, pressure surges at same frequency approx 3 psi, audible upstairs. Any suggestions? Bad bearings, blockage? The system is only 6 years old.

  • @user-ib5qi8ek2z
    @user-ib5qi8ek2z3 жыл бұрын

    Thank you for these informations. Can you tell me what should be the circulation pump’s body temberature while working? Since I found it very very hot when I touch it, Thanks

  • @mark-1234
    @mark-12344 жыл бұрын

    Not sure if this is the place to ask but I have a switching relay (Honeywell RA89A) that turns on my boiler contacters but my circulating pump is wired directly to a breaker and runs 24/7. I'd like to add a surface mounted temp control (was looking at a Johnson Controls A19DAC-1C, 100 to 240 deg F) to the pump circuit. Would I need to add another switching relay to do this, or do these temp controls switch 110V on their own?

  • @natashariley9226
    @natashariley92262 жыл бұрын

    ThankYou for Sharing this invaluable information. Can A Grunfos Alpha 2 circulating pump work with a Burnham boiler?

  • @rodbutler4054
    @rodbutler40545 ай бұрын

    I have replaced 4 circulating pumps over 10 years because they were running hot and probably failed prematurely. In my last replacement I surrounded the pump with strips of aluminum foil to draw away the heat and have noticed it runs cooler and more efficient.IMHO

  • @wildman8601
    @wildman86014 жыл бұрын

    Craig what's best side for a circ pump to be on a boiler coming off the supply side or coming off the return side

  • @armandotorres626
    @armandotorres6265 жыл бұрын

    I had a grundfos airlocked and was able to bleed out the air through the same access used to unlock the motor. Is that there for air bleeding purposes as well?? Great vids, long time subscriber...

  • @acservicetechchannel

    @acservicetechchannel

    5 жыл бұрын

    Not necessarily because the hole is not built out to the end of the casing but could be done if needed, thanks!

  • @josepeixoto3384
    @josepeixoto3384 Жыл бұрын

    video from a pro, we can tell; thanks

  • @ryans413
    @ryans4133 жыл бұрын

    My building I live in uses water heating and that pump they had was so noise you could hear it vibrating through the baseboard heating. Landlords finally got some guys in to replace it now it’s so silent I’m not use too it lol. I still hear little buzzing but not really loud anymore. Mostly just hear the water moving

  • @thesetruths1404
    @thesetruths14043 жыл бұрын

    Nice Instructional video! Thanks. Do you think Grundfos pumps are as good or better than Taco? I like how Grundfos has the shaft testing access.

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    Yes Grundfos are very nice in reference to that!

  • @jerseyshoredroneservices225
    @jerseyshoredroneservices2257 ай бұрын

    Some recirculating pumps have a flow check built in, correct? What happens if that gets gunked up or fails some other way? I have a very simple hot water system that first wouldn't make heat even though the hot water heater was hot. There was an inline flow check valve that was gunked up. Changing that out fixed the problem but also created a new one. With the new valve installed that heat just won't stop even with the thermostat turned off. Since that flow check valve was replaced the hot water seems to be circulating on its own due to and the heat inside here just won't stop.

  • @edgarkube3753
    @edgarkube37532 жыл бұрын

    I recently purchased a outdoor boiler with 2 water circulator output. One is ging to the house one to my shop. Both have circulation pumps. Nrf 25 to the house and nrf36 to the shop. That's bell gossett pumps. The one to the house works quiet and the one to the shop is working relatively laud. The laud one sounds like it has air inside the pump. I drained the line back into the boiler with a garden hose and pump running. But that didn't solve the problem. Is it possible that the pump itself got weak? Or inside damage so it creates vaccum/air within the pump that gets pushed into the system?

  • @jackjenkins6305
    @jackjenkins63053 жыл бұрын

    The thermostat electrical connector caps were touching making the Fasco blower, and possible the Taco Cartridge circulator continues to run until I pull the caps away from each other, then the blower stopped. Question: could there be a bad wire inside the connectors or can electric caps insulation go bad? I am thinking of having an electrician totally rewire the thermostat wiring from the house thermostat to the boiler control unit. Any thoughts or suggestions are appreciated?

  • @galenwaltman1656
    @galenwaltman16563 жыл бұрын

    What would cause one zone to continuously circulate?

  • @CraftMMORPGs
    @CraftMMORPGs3 жыл бұрын

    Can we do an amp draw test to see if the pump is running?

  • @koh9894
    @koh98944 жыл бұрын

    Please HELP!! Bell and Gossettt Series #100 Power getting to the pump: 122V Pump motor not turning with power but seems to turn freely with my screwdriver. I did try the Resistance test. I think I got 0.L (gonna look again) Electrical windings fried ??

  • @vitaliisiennikov4663
    @vitaliisiennikov4663 Жыл бұрын

    I have Taco 007-F5-71FC right now in my system. Can you tell me please on which model can I change it which have more power? Because right now it not enough power for two floors? Thank you!

  • @Alex-jo2oi
    @Alex-jo2oi Жыл бұрын

    I came across one where the pump assembly is rotting out. Roughly 10 years old. Is this due to lack of maintenance, and proper draining of the lines every so often?

  • @natashariley9226
    @natashariley92262 жыл бұрын

    The floors are vibrating can the new circulator pump be the issue?. Floor was not vibrating prior to installing the new pump. Please advise. ThankYou

  • @techmasterflash
    @techmasterflash2 жыл бұрын

    Call for heat… fan comes on, circ pump relay on Taco 3 zone controller barely clicks. Circ pump doesn’t come on? Intermittent issue. Thoughts?

  • @4439841362
    @44398413622 жыл бұрын

    Hi, my system is approx 10 years old. Circulator was replaced approx 3 years ago. Recently (august 2021) Why will circulator motor not shut off, thermostat is set at 40*F. Circ motor is hot. That loop is cold. I just purged the entire system (Circulator #1 in question has 2 heating zones with zone valves. Circulator #2 is for indirect domestic HW & no zone valve). Why will circ#1 not shut off?

  • @Tsilsby
    @Tsilsby2 жыл бұрын

    i have a question... i bought my house a few years ago. and they system works great. the boiler was manufactured in 1963 (IIRC) its old.. but it works perfectly. ok my question.... i don't have zones. its all one zone.. would they have built it consecutively or would each room go to a junction and feed back to the storage tank?? Also, there are times when it sound like water going through the radiator. like I don't think its 100% full of water... are they systems designed to be topped off.... or are they only filled up so much.. to make room for expansion when the water is heated...???... sorry this is all new technology to me... every house i have ever lived in has had force air system... This house also has a heat pump. with a back up heat grid... so I have 3 different ways to heat my house.. However, its was built at the end of the 19th century. so electric is stupid expensive to heat with.

  • @Tko_Seven
    @Tko_Seven5 ай бұрын

    is the pump supposed to generate magnetic field as the boiler switch is on or only when the pump is actively engaging?

  • @Vmartin70EZ
    @Vmartin70EZ7 ай бұрын

    My circulation pump is like the one before the red one and there's no noise at all there's no current going into the motor L1 wire, no shut off valves above or below the pump housing any advice how to stop water from leaking down out when I replace it?😕

  • @ABDELFIX
    @ABDELFIX8 ай бұрын

    Would a noisy circulator pump cause the pressure relief valve on the boiler to open up as well? I checked the pressure and it was around 20 psi and temperature was around 150-160 F, no problem there. So I'm not sure if the circulator pump is the problem or now I'm thinking maybe the expansion tank?

  • @jackieb8998
    @jackieb89983 жыл бұрын

    What kind of oil should I use for a circle pump like the red one you showed around @8:43 the larger one?

  • @acservicetechchannel

    @acservicetechchannel

    3 жыл бұрын

    zoom spout oil, thanks!

  • @jackieb8998

    @jackieb8998

    3 жыл бұрын

    @@acservicetechchannel thank you for letting me know! My pump stopped making the humming noise instantly.

  • @ernestodiaz76
    @ernestodiaz76 Жыл бұрын

    Do you have a book about heating systems?

  • @komakon
    @komakon Жыл бұрын

    My problem is #5 and I guess the builder never hooked the pump up to power. It's located in a box outside on the house next to the AC unit. I have a leak from the Taco pump but I can't seem to find a new O ring anywhere, do you know where I could find one? the Model number is 006-BC5Y-1 any help is appriciated.

  • @robertmicheline1551
    @robertmicheline15512 жыл бұрын

    what do you do if it dry when you motor off felt no water in the circulator

  • @annacacheiro9983
    @annacacheiro99833 жыл бұрын

    My problem is that I cannot have both my floors heating system on, if I put on the 1st floor, my second floor shuts off and vice versa. Any suggestions would be greatly appreciated

  • @bpdp379

    @bpdp379

    Жыл бұрын

    It may be setup to use a priority zone.

  • @jstavene
    @jstavene Жыл бұрын

    Out of curiosity if you have say 4 zones and 1 zone does not have water at a bleed valve, is it possible there is no water because the circulator pump locked up? or would it be more likely the bleed valve is not working? (its -26 ) and I am not taking the boiler offline or changing water if I can help it and everything else seems fine and working?

  • @sirhc07

    @sirhc07

    Жыл бұрын

    More than likely the zone was frozen for that extreme cold weather

  • @MustPassTruck
    @MustPassTruck4 жыл бұрын

    I'm fine turning wrenches, but the stuff with angry fairies always throws me off.

  • @daveschooley8514
    @daveschooley85142 жыл бұрын

    I have a taco 0011-f4 pump, can the impeller get worn down and only pump a small amount, about 3 pm? How can I tell what the problem is?

  • @bpdp379

    @bpdp379

    Жыл бұрын

    Cavitation can definitely wear an impeller down to nothing.

  • @rtta51
    @rtta513 жыл бұрын

    Can't find anyone who sells just the Taco motors.

  • @sportykev
    @sportykev3 жыл бұрын

    Exactly what I needed, believe my impeller is seized in the Taco Circulator Pump. Hit it with a hammer worked...

  • @pmny3423

    @pmny3423

    3 жыл бұрын

    The old caveman method. Might have to try that out on mine.

  • @robinjoly9262
    @robinjoly92622 жыл бұрын

    My pump was not circulating water and was making a very high pitch squeeling sound. With online help from a relative, I was advised that the impeller was likely stuck and the high pitch sound was the shaft spinning. He said try hitting it with a wrench to get it spinning, which I did. The impeller then was spinning again and water was circulating. I believe this problem was caused because a repairman left my water supply off after a small leak repair. It was off for almost 2 weeks. Does anyone think that this pump is now compromised and that the company should pay to replace this pump?

  • @dovikel
    @dovikel Жыл бұрын

    I wonder - in a 4 zone boiler - can defective circulator pump do the job for 3 zones and not to the forth zone?

  • @caru3257

    @caru3257

    Жыл бұрын

    No.

  • @faroyoussef1757
    @faroyoussef17572 жыл бұрын

    Guys why there is a flow of electricity everywhere in the boiler except the pump??

  • @Alex-jo2oi

    @Alex-jo2oi

    Жыл бұрын

    Faulty ground somewhere? I’d definitely call out an electrician.

  • @caru3257

    @caru3257

    Жыл бұрын

    @@Alex-jo2oi Aquastat likely bad if boiler is at high limit temperature.

  • @jde1780
    @jde17802 жыл бұрын

    We're always thankful for the information you share, but It would be *much* better if you used the term "Micro Farad", instead of "UF". Even though we understand, the Unit Of Measurement is microfarads, not UF's. It's the same as the movie Back To The Future: He uses the term "Jigga-Watts" instead of "Gigawatts". You'll be teaching the incorrect unit pronunciation/terms to new students. Regardless of my pet peeve, thanks for sharing.

  • @q7jdwomfvkbj74
    @q7jdwomfvkbj742 жыл бұрын

    12 to 15 psig cold 20 to 22 psig hot

  • @schloshyjea1
    @schloshyjea1 Жыл бұрын

    UF is pronounced microfarad :)

  • @Tsilsby
    @Tsilsby2 жыл бұрын

    I have the larger red style pump. when i bought my house the seller showed me how to oil they system.. but he only showed me the 1 oil port on the propeller. learn something new every day. now to replace the o ring cause its leaking at the flange....

  • @Yourengineeringstandpt
    @Yourengineeringstandpt3 жыл бұрын

    Sleeve pump cartridge replacement you didn't show them that that's what you do k your welcome?!!!

  • @zeez4178
    @zeez41783 ай бұрын

    Solutions 😡?

  • @seg83423
    @seg834233 ай бұрын

    youtube algorithm