Tips for Design of RCC Beam - Civil Engineering Videos
#designofcolumnfooting
Жүктеу.....
Пікірлер: 397
@tasadduqmajeed685 жыл бұрын
Waalikum Assalam Sir. A very useful today class. Jazakumullah Khair.
@manishchaudhary88796 жыл бұрын
Great job!!! But how to calculate the no.of bars & what dia. of bar has been provided in a Beam..
@bariyowhassanmohamed79333 жыл бұрын
Thanks. point of correction. In calculation of no. of stirrups, you either convert 5m to cm or change cover to meter.
@habibghazi99745 жыл бұрын
Thanks sir, to day good lecture.
@jamshadkhan4755 жыл бұрын
I am thankful for all your good efforts, Plz can u make a video on the " How to seleect steel dia in colunm, beam or slabs" thanks
@mansoortp31385 жыл бұрын
Sir. 5m length beam, we get 0.30 m depth beam. Then in this depth add or not slab thick
@ar.avadheshsingh26166 жыл бұрын
How we decide the orientation of column if column is rectangular
@SatansBaby13 жыл бұрын
GREAT JOB! What would be the load capacity of that beam? 5 tons?
@booksourexistence21535 жыл бұрын
Thanks a million sirji..... Oalaikumasalam........
@xylemfun5 жыл бұрын
Is that formula can be use for any types of beam such as CANTILEVER BEAM, SIMPLY S. B....to find out depth & breath ....?
@dzignarchitects31394 жыл бұрын
Is this beam depth calculate including roof slab ?
@surajitpaul94486 жыл бұрын
Nice video Sir..
@MasterCivilEngineering3 жыл бұрын
Expertise civil engineering knowledge
@namitanagwanshi49655 жыл бұрын
Which size of steel bar use in different different beam column and slabs? With thumb rule
@civillogy2 жыл бұрын
i like it,you explain eveything in detail
@chomtungemu24733 жыл бұрын
For how many storey building Is this rule of finding beam size applicable ?
@muhammadhafiz31455 жыл бұрын
I didn't understand what you mean about that to find the length and size of steel in the beam calculation. Pls explain
@perezcarladrian36124 жыл бұрын
What is the topic in reinforced concrete design the formula you use? Thank you for answers
@SanjaySingh-hf2mt5 жыл бұрын
i confused.. we are finding column D/B or for beam....?
@dr.fakharАй бұрын
how will be decided about spacing of stirups. is it based on guess?
@voiceofchemistrynarendersi98735 жыл бұрын
Nice info. Thanks and regards. There is an inadvertent mistake in number of stirrups, you should have taken covered length also in m i.e. 2x25/1000, Else it gives wrong answer. N. K. Sharma
@Ridewithsagar5 жыл бұрын
The cover length is always mm?
@michaelnjuguna36255 жыл бұрын
Can i use those formula if we use British standard?
@perlitocaballa15515 жыл бұрын
what is the size of the steel bar and how many bars on the beam and column thanks
@khairulariffin89865 жыл бұрын
Hye is that got diffrence.for.double storey building or multilevel building such as for.design
@omanprobashimahossain.25975 жыл бұрын
Nice ... abbreviation....
@mahinderkumar23455 жыл бұрын
Thank,s you sir, I also want to know number of bar in the column & beam and thickness of bar by code of load presser
@ernestodelacruz1775 жыл бұрын
How do we know that it can withstand stress or the load? How do you get top bars and bottom bars? Why area of column? You are discussing beam not column
@sunilbanala9675 жыл бұрын
how to consider the slab load at the beam
@MitaliPatel5 жыл бұрын
How to find stess for concrete and steel and composite doubly rc beam and I want to take steel Fe 415 and concrete grade is M25
@manojkamrarti81555 жыл бұрын
where can we find formula of beam width b=d/1.5
@11_kirito1428 күн бұрын
Is it thee same process for designing continuous beam and overhanging beam
@facts94203 жыл бұрын
It was useful , 👍👍
@chethanbhounsley35 жыл бұрын
Hi Sir , There were 11pillars in ground floor due to plan change in first floor center pillar was removed in first floor plan so distance between two column became 20 feet so builder added beam which now is 20 feet long i am bothered weather it sustain load
@ramroy91434 жыл бұрын
Wow NC defined sir
@omanprobashimahossain.25975 жыл бұрын
Dear sir, how can calculate the foundation's column steel rightangle portion's length ? That means 16 mm./ 18mm/20mm steel 's rightangle length how much will come in footing.
@kalindumadushan9205 жыл бұрын
what is the load that you put here ?
@karthiks80105 жыл бұрын
Sir I need design 19ft width 39ft length, high 18fts need to cover full roof no walls only need to cover with help of columns can u design steal for both columns bems n roof pls
@naseerhussain37414 жыл бұрын
As Salaamo Alaikum sir How to use the 24 cm^2 to die of steel and number of bars
@varinderladdi17765 жыл бұрын
thanks to you up load this video
@ar.avadheshsingh26166 жыл бұрын
Two things 1) how 24 will convert in to kg and how to find dia of bars. 2) (5-2×.025)÷0.3 +1 = 17.5
@MasterCivilEngineering
3 жыл бұрын
Good bro
@shaikfiroz31516 жыл бұрын
how much steel provide ? which dia bar used ?
@mygarden26944 жыл бұрын
What is the thikness of beam steel.maybe 16mm/12mm
@kanthimathimk78275 жыл бұрын
I could follow everything clearly from your video, but what is meant by cover as mentioned in formula for counting stirrups?
@neelimeghampavankumar8955
4 жыл бұрын
It is clear cover ..and as rod starts placing just inside the concrete right...length in-between bar to edge of beam..
@dineshkumarbairwa87905 жыл бұрын
Compression and tenaion steel to design kr leta hu but bent up bar provide krte h n beam m vo kb krte h or kitni krte h or kese design krte h
@silentactor5584 жыл бұрын
Sir i would like to know if Indian Standard is it same as British standards? Thanks fir your ans....
@homedesign39645 жыл бұрын
It's very useful for us
@InDepthCreation5 жыл бұрын
Give specifications about end covers and side covers?
@dalliramireddy33956 жыл бұрын
Bro ur teaching skills are amezing...🗣👏 But one small requast to u... Please maintain proper units throughout the problems...and one particular dout in this lecture is ...u found out the amount of steel required in terms of area but i want in terms of weight.So please share your valuable reply.Thnkq🤗
@M.Hassan19 Жыл бұрын
This calculation is useful only to get a rough idea. To find exact values of dimensions and steel area you must need to for more complex calculations considering loads and moment. By the way thanks for this rough calculation.
@SivaPrasad-qn9fo5 жыл бұрын
The load apply if change the c/s Explain that way
@baljindersingh63375 жыл бұрын
Sir in 4 meter length beam what should actual size of bar and what mm size of bar used
@JudePiosMusic5 жыл бұрын
is it possible if i use this method to our country? as you mentioned it is on IS code ,
@imranafridi85135 жыл бұрын
Which cocrete use for this beam to achieve required strength and how find no of bars from ast
@MasterCivilEngineering
3 жыл бұрын
Watch here to know more
@user-ti7dn3mb9p5 жыл бұрын
How we find what dia.of steel we provide ?
@RajKumar-ge7xc5 жыл бұрын
How to find steel size of one beam @ column
@haseenabegum1833 жыл бұрын
Assalamualaikum bai its very help us.thanks
@pradipta2225 жыл бұрын
For 2 story 30x40 home pl tell me the column design
@dharamrahasya44355 жыл бұрын
Sir will you please describe the area of steel how we can get steel dia meter and design the bars area exact in beams .
@carlodigma51283 жыл бұрын
Can you show as the complete design for the whole house from roof to footing. Thanks and God bless.
@imdadullahadil66034 жыл бұрын
good luck sir g
@hanadnor24574 жыл бұрын
Bro, in the no of stirrups when u say length - 2xcover, the unit of length is meter which 5m and cover is 25mm as u said so how can we subtract meter and mm (i.e. 5m - 2x25mm) is it possible?
@rajusekh757
2 жыл бұрын
Absolutely right
@premkanaujia14775 жыл бұрын
How decide size of bars after calculating area of steel
@AliRaza-vl1kr5 жыл бұрын
What’s mean of 16 or 1.5 in d or b formulas.?
@selvasiyan5 жыл бұрын
how we used for steel d 8mm&10mm
@kondehyoursseh23783 жыл бұрын
Am happy with the teaching
@zenichbad5 жыл бұрын
what is the misery behind l/6 and d/ 1.5 what is the basic concept behind that?
@aaliyahkhan85656 ай бұрын
Very useful
@trawallyousman25095 жыл бұрын
How did you derived the 30cm spacing.
@sonukumar-bp4wb
4 жыл бұрын
Assumed
@maybeerin78684 жыл бұрын
Thank you!
@laughandgrowliam2 жыл бұрын
How we can decide the spacing of strirrups?
@FarukAli-fu1ug5 жыл бұрын
Sorry how do u work out how many rods u needs with 24cm sq???
@stelvinthomas97144 жыл бұрын
Very helpful
@vphls5 жыл бұрын
Thanks! I'll be sure to avoid walking underneath loads supported by concrete beams in India or Pakistan
@parwezakhtar7810
3 жыл бұрын
😁😁😁 What a satire ,,,, Even we Indian & Pakistani engineers avoid. Blogger is not an Engineer. No need to calculate shear street, bending moment, load etc 😆😆😆
@dindoanonat525 жыл бұрын
Bro how to calculate the spacing distance of stirrups and the size of sleel
@shanmukhl.k.3869 Жыл бұрын
Thanks 🙏 Pls make video for Plinth beam 🙏
@babatunderidwan21163 жыл бұрын
How did you get the space to 30cm?
@hadikallas435 жыл бұрын
Sir, how to design the stirrups spacing. I mean u chose 30 cm, but based on what?
@R.k449
4 жыл бұрын
Great bro
@farhoodkarimimir58835 жыл бұрын
Hi, To find depth: 5m/16=0.3125m and this the minimum you can have, you can’t round up the number to lower value of 0.3m or 30cm. You should round up to a higher value like 0.32m or 32cm to avoid disaster:) regards
@kleinnacion5094
5 жыл бұрын
Agree
@nathanielanaene3010
5 жыл бұрын
@@kleinnacion5094 true
@emailtour
4 жыл бұрын
@@kleinnacion5094 building will fall down😂😂😂
@vonbbm-du30-bsj59
3 жыл бұрын
Absolutely 👍
@Mohankumar-vd7ih5 жыл бұрын
Sir how to give steel bar and how many number ,please explain sir ,you just 4% x section area, how to use 24 sqmm cross section area
@satishkumargarg1643 жыл бұрын
Is d effective length or gross length?
@JoshuaDetablan4 жыл бұрын
16 and 1.5 are constant?
@KulwantSingh-yw6wh3 жыл бұрын
What is d include slab?
@johnbenson31745 жыл бұрын
24cm2 how does that converts to the diameter of the steel .
@MultiJjk5 жыл бұрын
What about hanging beam? Can i use same formula for hanging beam?
@mk.maiappan1608 Жыл бұрын
Thanks you so much
@iacsse63814 жыл бұрын
Bars must be found according to the dia and tensile strength; decrease or increase the number of bars must be inversely proportional to one another. depth can be up to L/36 [in case of concealed beams. am I right?
@keoseyha93904 жыл бұрын
good explain
@tasadduqmajeed685 жыл бұрын
Kindly learn more about the steel area in colum. in the light of formula (Amount of steel).
@raufliaquat84243 жыл бұрын
How we know there 5 steel are come in beam and which dia
@abimbolaadam61745 жыл бұрын
Thanks for the tutorial But does this goes the same way with the use of BS code?
@balajig46894 жыл бұрын
Final tip- beam length in meter and clear cover in mm ...why?
@rrd4635 жыл бұрын
Wt. About col. & footing sizes with steel. Regards
@Mohankumar-vd7ih5 жыл бұрын
Sir if length of beam 3 mtr ,what will the depth and bredth sir,
@barakshahkakar74665 жыл бұрын
Great Sir
@tokerkhel14915 жыл бұрын
Bahii jan if the dimensions is in feet then?
@nagusapavath42684 жыл бұрын
I want how much steel provide.. In KGS & tons
@pubgprince62125 жыл бұрын
sir here in this vedio you are showing about design of beam only but i need the formula of load calculation about this member....and easy process
Пікірлер: 397
Waalikum Assalam Sir. A very useful today class. Jazakumullah Khair.
Great job!!! But how to calculate the no.of bars & what dia. of bar has been provided in a Beam..
Thanks. point of correction. In calculation of no. of stirrups, you either convert 5m to cm or change cover to meter.
Thanks sir, to day good lecture.
I am thankful for all your good efforts, Plz can u make a video on the " How to seleect steel dia in colunm, beam or slabs" thanks
Sir. 5m length beam, we get 0.30 m depth beam. Then in this depth add or not slab thick
How we decide the orientation of column if column is rectangular
GREAT JOB! What would be the load capacity of that beam? 5 tons?
Thanks a million sirji..... Oalaikumasalam........
Is that formula can be use for any types of beam such as CANTILEVER BEAM, SIMPLY S. B....to find out depth & breath ....?
Is this beam depth calculate including roof slab ?
Nice video Sir..
Expertise civil engineering knowledge
Which size of steel bar use in different different beam column and slabs? With thumb rule
i like it,you explain eveything in detail
For how many storey building Is this rule of finding beam size applicable ?
I didn't understand what you mean about that to find the length and size of steel in the beam calculation. Pls explain
What is the topic in reinforced concrete design the formula you use? Thank you for answers
i confused.. we are finding column D/B or for beam....?
how will be decided about spacing of stirups. is it based on guess?
Nice info. Thanks and regards. There is an inadvertent mistake in number of stirrups, you should have taken covered length also in m i.e. 2x25/1000, Else it gives wrong answer. N. K. Sharma
The cover length is always mm?
Can i use those formula if we use British standard?
what is the size of the steel bar and how many bars on the beam and column thanks
Hye is that got diffrence.for.double storey building or multilevel building such as for.design
Nice ... abbreviation....
Thank,s you sir, I also want to know number of bar in the column & beam and thickness of bar by code of load presser
How do we know that it can withstand stress or the load? How do you get top bars and bottom bars? Why area of column? You are discussing beam not column
how to consider the slab load at the beam
How to find stess for concrete and steel and composite doubly rc beam and I want to take steel Fe 415 and concrete grade is M25
where can we find formula of beam width b=d/1.5
Is it thee same process for designing continuous beam and overhanging beam
It was useful , 👍👍
Hi Sir , There were 11pillars in ground floor due to plan change in first floor center pillar was removed in first floor plan so distance between two column became 20 feet so builder added beam which now is 20 feet long i am bothered weather it sustain load
Wow NC defined sir
Dear sir, how can calculate the foundation's column steel rightangle portion's length ? That means 16 mm./ 18mm/20mm steel 's rightangle length how much will come in footing.
what is the load that you put here ?
Sir I need design 19ft width 39ft length, high 18fts need to cover full roof no walls only need to cover with help of columns can u design steal for both columns bems n roof pls
As Salaamo Alaikum sir How to use the 24 cm^2 to die of steel and number of bars
thanks to you up load this video
Two things 1) how 24 will convert in to kg and how to find dia of bars. 2) (5-2×.025)÷0.3 +1 = 17.5
@MasterCivilEngineering
3 жыл бұрын
Good bro
how much steel provide ? which dia bar used ?
What is the thikness of beam steel.maybe 16mm/12mm
I could follow everything clearly from your video, but what is meant by cover as mentioned in formula for counting stirrups?
@neelimeghampavankumar8955
4 жыл бұрын
It is clear cover ..and as rod starts placing just inside the concrete right...length in-between bar to edge of beam..
Compression and tenaion steel to design kr leta hu but bent up bar provide krte h n beam m vo kb krte h or kitni krte h or kese design krte h
Sir i would like to know if Indian Standard is it same as British standards? Thanks fir your ans....
It's very useful for us
Give specifications about end covers and side covers?
Bro ur teaching skills are amezing...🗣👏 But one small requast to u... Please maintain proper units throughout the problems...and one particular dout in this lecture is ...u found out the amount of steel required in terms of area but i want in terms of weight.So please share your valuable reply.Thnkq🤗
This calculation is useful only to get a rough idea. To find exact values of dimensions and steel area you must need to for more complex calculations considering loads and moment. By the way thanks for this rough calculation.
The load apply if change the c/s Explain that way
Sir in 4 meter length beam what should actual size of bar and what mm size of bar used
is it possible if i use this method to our country? as you mentioned it is on IS code ,
Which cocrete use for this beam to achieve required strength and how find no of bars from ast
@MasterCivilEngineering
3 жыл бұрын
Watch here to know more
How we find what dia.of steel we provide ?
How to find steel size of one beam @ column
Assalamualaikum bai its very help us.thanks
For 2 story 30x40 home pl tell me the column design
Sir will you please describe the area of steel how we can get steel dia meter and design the bars area exact in beams .
Can you show as the complete design for the whole house from roof to footing. Thanks and God bless.
good luck sir g
Bro, in the no of stirrups when u say length - 2xcover, the unit of length is meter which 5m and cover is 25mm as u said so how can we subtract meter and mm (i.e. 5m - 2x25mm) is it possible?
@rajusekh757
2 жыл бұрын
Absolutely right
How decide size of bars after calculating area of steel
What’s mean of 16 or 1.5 in d or b formulas.?
how we used for steel d 8mm&10mm
Am happy with the teaching
what is the misery behind l/6 and d/ 1.5 what is the basic concept behind that?
Very useful
How did you derived the 30cm spacing.
@sonukumar-bp4wb
4 жыл бұрын
Assumed
Thank you!
How we can decide the spacing of strirrups?
Sorry how do u work out how many rods u needs with 24cm sq???
Very helpful
Thanks! I'll be sure to avoid walking underneath loads supported by concrete beams in India or Pakistan
@parwezakhtar7810
3 жыл бұрын
😁😁😁 What a satire ,,,, Even we Indian & Pakistani engineers avoid. Blogger is not an Engineer. No need to calculate shear street, bending moment, load etc 😆😆😆
Bro how to calculate the spacing distance of stirrups and the size of sleel
Thanks 🙏 Pls make video for Plinth beam 🙏
How did you get the space to 30cm?
Sir, how to design the stirrups spacing. I mean u chose 30 cm, but based on what?
@R.k449
4 жыл бұрын
Great bro
Hi, To find depth: 5m/16=0.3125m and this the minimum you can have, you can’t round up the number to lower value of 0.3m or 30cm. You should round up to a higher value like 0.32m or 32cm to avoid disaster:) regards
@kleinnacion5094
5 жыл бұрын
Agree
@nathanielanaene3010
5 жыл бұрын
@@kleinnacion5094 true
@emailtour
4 жыл бұрын
@@kleinnacion5094 building will fall down😂😂😂
@vonbbm-du30-bsj59
3 жыл бұрын
Absolutely 👍
Sir how to give steel bar and how many number ,please explain sir ,you just 4% x section area, how to use 24 sqmm cross section area
Is d effective length or gross length?
16 and 1.5 are constant?
What is d include slab?
24cm2 how does that converts to the diameter of the steel .
What about hanging beam? Can i use same formula for hanging beam?
Thanks you so much
Bars must be found according to the dia and tensile strength; decrease or increase the number of bars must be inversely proportional to one another. depth can be up to L/36 [in case of concealed beams. am I right?
good explain
Kindly learn more about the steel area in colum. in the light of formula (Amount of steel).
How we know there 5 steel are come in beam and which dia
Thanks for the tutorial But does this goes the same way with the use of BS code?
Final tip- beam length in meter and clear cover in mm ...why?
Wt. About col. & footing sizes with steel. Regards
Sir if length of beam 3 mtr ,what will the depth and bredth sir,
Great Sir
Bahii jan if the dimensions is in feet then?
I want how much steel provide.. In KGS & tons
sir here in this vedio you are showing about design of beam only but i need the formula of load calculation about this member....and easy process
ടir pls add Estimation of culvert
Is The length should be clear span?