Tips for Design of RCC Beam - Civil Engineering Videos

#designofcolumnfooting

Пікірлер: 397

  • @tasadduqmajeed68
    @tasadduqmajeed685 жыл бұрын

    Waalikum Assalam Sir. A very useful today class. Jazakumullah Khair.

  • @manishchaudhary8879
    @manishchaudhary88796 жыл бұрын

    Great job!!! But how to calculate the no.of bars & what dia. of bar has been provided in a Beam..

  • @bariyowhassanmohamed7933
    @bariyowhassanmohamed79333 жыл бұрын

    Thanks. point of correction. In calculation of no. of stirrups, you either convert 5m to cm or change cover to meter.

  • @habibghazi9974
    @habibghazi99745 жыл бұрын

    Thanks sir, to day good lecture.

  • @jamshadkhan475
    @jamshadkhan4755 жыл бұрын

    I am thankful for all your good efforts, Plz can u make a video on the " How to seleect steel dia in colunm, beam or slabs" thanks

  • @mansoortp3138
    @mansoortp31385 жыл бұрын

    Sir. 5m length beam, we get 0.30 m depth beam. Then in this depth add or not slab thick

  • @ar.avadheshsingh2616
    @ar.avadheshsingh26166 жыл бұрын

    How we decide the orientation of column if column is rectangular

  • @SatansBaby1
    @SatansBaby13 жыл бұрын

    GREAT JOB! What would be the load capacity of that beam? 5 tons?

  • @booksourexistence2153
    @booksourexistence21535 жыл бұрын

    Thanks a million sirji..... Oalaikumasalam........

  • @xylemfun
    @xylemfun5 жыл бұрын

    Is that formula can be use for any types of beam such as CANTILEVER BEAM, SIMPLY S. B....to find out depth & breath ....?

  • @dzignarchitects3139
    @dzignarchitects31394 жыл бұрын

    Is this beam depth calculate including roof slab ?

  • @surajitpaul9448
    @surajitpaul94486 жыл бұрын

    Nice video Sir..

  • @MasterCivilEngineering
    @MasterCivilEngineering3 жыл бұрын

    Expertise civil engineering knowledge

  • @namitanagwanshi4965
    @namitanagwanshi49655 жыл бұрын

    Which size of steel bar use in different different beam column and slabs? With thumb rule

  • @civillogy
    @civillogy2 жыл бұрын

    i like it,you explain eveything in detail

  • @chomtungemu2473
    @chomtungemu24733 жыл бұрын

    For how many storey building Is this rule of finding beam size applicable ?

  • @muhammadhafiz3145
    @muhammadhafiz31455 жыл бұрын

    I didn't understand what you mean about that to find the length and size of steel in the beam calculation. Pls explain

  • @perezcarladrian3612
    @perezcarladrian36124 жыл бұрын

    What is the topic in reinforced concrete design the formula you use? Thank you for answers

  • @SanjaySingh-hf2mt
    @SanjaySingh-hf2mt5 жыл бұрын

    i confused.. we are finding column D/B or for beam....?

  • @dr.fakhar
    @dr.fakharАй бұрын

    how will be decided about spacing of stirups. is it based on guess?

  • @voiceofchemistrynarendersi9873
    @voiceofchemistrynarendersi98735 жыл бұрын

    Nice info. Thanks and regards. There is an inadvertent mistake in number of stirrups, you should have taken covered length also in m i.e. 2x25/1000, Else it gives wrong answer. N. K. Sharma

  • @Ridewithsagar
    @Ridewithsagar5 жыл бұрын

    The cover length is always mm?

  • @michaelnjuguna3625
    @michaelnjuguna36255 жыл бұрын

    Can i use those formula if we use British standard?

  • @perlitocaballa1551
    @perlitocaballa15515 жыл бұрын

    what is the size of the steel bar and how many bars on the beam and column thanks

  • @khairulariffin8986
    @khairulariffin89865 жыл бұрын

    Hye is that got diffrence.for.double storey building or multilevel building such as for.design

  • @omanprobashimahossain.2597
    @omanprobashimahossain.25975 жыл бұрын

    Nice ... abbreviation....

  • @mahinderkumar2345
    @mahinderkumar23455 жыл бұрын

    Thank,s you sir, I also want to know number of bar in the column & beam and thickness of bar by code of load presser

  • @ernestodelacruz177
    @ernestodelacruz1775 жыл бұрын

    How do we know that it can withstand stress or the load? How do you get top bars and bottom bars? Why area of column? You are discussing beam not column

  • @sunilbanala967
    @sunilbanala9675 жыл бұрын

    how to consider the slab load at the beam

  • @MitaliPatel
    @MitaliPatel5 жыл бұрын

    How to find stess for concrete and steel and composite doubly rc beam and I want to take steel Fe 415 and concrete grade is M25

  • @manojkamrarti8155
    @manojkamrarti81555 жыл бұрын

    where can we find formula of beam width b=d/1.5

  • @11_kirito14
    @11_kirito1428 күн бұрын

    Is it thee same process for designing continuous beam and overhanging beam

  • @facts9420
    @facts94203 жыл бұрын

    It was useful , 👍👍

  • @chethanbhounsley3
    @chethanbhounsley35 жыл бұрын

    Hi Sir , There were 11pillars in ground floor due to plan change in first floor center pillar was removed in first floor plan so distance between two column became 20 feet so builder added beam which now is 20 feet long i am bothered weather it sustain load

  • @ramroy9143
    @ramroy91434 жыл бұрын

    Wow NC defined sir

  • @omanprobashimahossain.2597
    @omanprobashimahossain.25975 жыл бұрын

    Dear sir, how can calculate the foundation's column steel rightangle portion's length ? That means 16 mm./ 18mm/20mm steel 's rightangle length how much will come in footing.

  • @kalindumadushan920
    @kalindumadushan9205 жыл бұрын

    what is the load that you put here ?

  • @karthiks8010
    @karthiks80105 жыл бұрын

    Sir I need design 19ft width 39ft length, high 18fts need to cover full roof no walls only need to cover with help of columns can u design steal for both columns bems n roof pls

  • @naseerhussain3741
    @naseerhussain37414 жыл бұрын

    As Salaamo Alaikum sir How to use the 24 cm^2 to die of steel and number of bars

  • @varinderladdi1776
    @varinderladdi17765 жыл бұрын

    thanks to you up load this video

  • @ar.avadheshsingh2616
    @ar.avadheshsingh26166 жыл бұрын

    Two things 1) how 24 will convert in to kg and how to find dia of bars. 2) (5-2×.025)÷0.3 +1 = 17.5

  • @MasterCivilEngineering

    @MasterCivilEngineering

    3 жыл бұрын

    Good bro

  • @shaikfiroz3151
    @shaikfiroz31516 жыл бұрын

    how much steel provide ? which dia bar used ?

  • @mygarden2694
    @mygarden26944 жыл бұрын

    What is the thikness of beam steel.maybe 16mm/12mm

  • @kanthimathimk7827
    @kanthimathimk78275 жыл бұрын

    I could follow everything clearly from your video, but what is meant by cover as mentioned in formula for counting stirrups?

  • @neelimeghampavankumar8955

    @neelimeghampavankumar8955

    4 жыл бұрын

    It is clear cover ..and as rod starts placing just inside the concrete right...length in-between bar to edge of beam..

  • @dineshkumarbairwa8790
    @dineshkumarbairwa87905 жыл бұрын

    Compression and tenaion steel to design kr leta hu but bent up bar provide krte h n beam m vo kb krte h or kitni krte h or kese design krte h

  • @silentactor558
    @silentactor5584 жыл бұрын

    Sir i would like to know if Indian Standard is it same as British standards? Thanks fir your ans....

  • @homedesign3964
    @homedesign39645 жыл бұрын

    It's very useful for us

  • @InDepthCreation
    @InDepthCreation5 жыл бұрын

    Give specifications about end covers and side covers?

  • @dalliramireddy3395
    @dalliramireddy33956 жыл бұрын

    Bro ur teaching skills are amezing...🗣👏 But one small requast to u... Please maintain proper units throughout the problems...and one particular dout in this lecture is ...u found out the amount of steel required in terms of area but i want in terms of weight.So please share your valuable reply.Thnkq🤗

  • @M.Hassan19
    @M.Hassan19 Жыл бұрын

    This calculation is useful only to get a rough idea. To find exact values of dimensions and steel area you must need to for more complex calculations considering loads and moment. By the way thanks for this rough calculation.

  • @SivaPrasad-qn9fo
    @SivaPrasad-qn9fo5 жыл бұрын

    The load apply if change the c/s Explain that way

  • @baljindersingh6337
    @baljindersingh63375 жыл бұрын

    Sir in 4 meter length beam what should actual size of bar and what mm size of bar used

  • @JudePiosMusic
    @JudePiosMusic5 жыл бұрын

    is it possible if i use this method to our country? as you mentioned it is on IS code ,

  • @imranafridi8513
    @imranafridi85135 жыл бұрын

    Which cocrete use for this beam to achieve required strength and how find no of bars from ast

  • @MasterCivilEngineering

    @MasterCivilEngineering

    3 жыл бұрын

    Watch here to know more

  • @user-ti7dn3mb9p
    @user-ti7dn3mb9p5 жыл бұрын

    How we find what dia.of steel we provide ?

  • @RajKumar-ge7xc
    @RajKumar-ge7xc5 жыл бұрын

    How to find steel size of one beam @ column

  • @haseenabegum183
    @haseenabegum1833 жыл бұрын

    Assalamualaikum bai its very help us.thanks

  • @pradipta222
    @pradipta2225 жыл бұрын

    For 2 story 30x40 home pl tell me the column design

  • @dharamrahasya4435
    @dharamrahasya44355 жыл бұрын

    Sir will you please describe the area of steel how we can get steel dia meter and design the bars area exact in beams .

  • @carlodigma5128
    @carlodigma51283 жыл бұрын

    Can you show as the complete design for the whole house from roof to footing. Thanks and God bless.

  • @imdadullahadil6603
    @imdadullahadil66034 жыл бұрын

    good luck sir g

  • @hanadnor2457
    @hanadnor24574 жыл бұрын

    Bro, in the no of stirrups when u say length - 2xcover, the unit of length is meter which 5m and cover is 25mm as u said so how can we subtract meter and mm (i.e. 5m - 2x25mm) is it possible?

  • @rajusekh757

    @rajusekh757

    2 жыл бұрын

    Absolutely right

  • @premkanaujia1477
    @premkanaujia14775 жыл бұрын

    How decide size of bars after calculating area of steel

  • @AliRaza-vl1kr
    @AliRaza-vl1kr5 жыл бұрын

    What’s mean of 16 or 1.5 in d or b formulas.?

  • @selvasiyan
    @selvasiyan5 жыл бұрын

    how we used for steel d 8mm&10mm

  • @kondehyoursseh2378
    @kondehyoursseh23783 жыл бұрын

    Am happy with the teaching

  • @zenichbad
    @zenichbad5 жыл бұрын

    what is the misery behind l/6 and d/ 1.5 what is the basic concept behind that?

  • @aaliyahkhan8565
    @aaliyahkhan85656 ай бұрын

    Very useful

  • @trawallyousman2509
    @trawallyousman25095 жыл бұрын

    How did you derived the 30cm spacing.

  • @sonukumar-bp4wb

    @sonukumar-bp4wb

    4 жыл бұрын

    Assumed

  • @maybeerin7868
    @maybeerin78684 жыл бұрын

    Thank you!

  • @laughandgrowliam
    @laughandgrowliam2 жыл бұрын

    How we can decide the spacing of strirrups?

  • @FarukAli-fu1ug
    @FarukAli-fu1ug5 жыл бұрын

    Sorry how do u work out how many rods u needs with 24cm sq???

  • @stelvinthomas9714
    @stelvinthomas97144 жыл бұрын

    Very helpful

  • @vphls
    @vphls5 жыл бұрын

    Thanks! I'll be sure to avoid walking underneath loads supported by concrete beams in India or Pakistan

  • @parwezakhtar7810

    @parwezakhtar7810

    3 жыл бұрын

    😁😁😁 What a satire ,,,, Even we Indian & Pakistani engineers avoid. Blogger is not an Engineer. No need to calculate shear street, bending moment, load etc 😆😆😆

  • @dindoanonat52
    @dindoanonat525 жыл бұрын

    Bro how to calculate the spacing distance of stirrups and the size of sleel

  • @shanmukhl.k.3869
    @shanmukhl.k.3869 Жыл бұрын

    Thanks 🙏 Pls make video for Plinth beam 🙏

  • @babatunderidwan2116
    @babatunderidwan21163 жыл бұрын

    How did you get the space to 30cm?

  • @hadikallas43
    @hadikallas435 жыл бұрын

    Sir, how to design the stirrups spacing. I mean u chose 30 cm, but based on what?

  • @R.k449

    @R.k449

    4 жыл бұрын

    Great bro

  • @farhoodkarimimir5883
    @farhoodkarimimir58835 жыл бұрын

    Hi, To find depth: 5m/16=0.3125m and this the minimum you can have, you can’t round up the number to lower value of 0.3m or 30cm. You should round up to a higher value like 0.32m or 32cm to avoid disaster:) regards

  • @kleinnacion5094

    @kleinnacion5094

    5 жыл бұрын

    Agree

  • @nathanielanaene3010

    @nathanielanaene3010

    5 жыл бұрын

    @@kleinnacion5094 true

  • @emailtour

    @emailtour

    4 жыл бұрын

    @@kleinnacion5094 building will fall down😂😂😂

  • @vonbbm-du30-bsj59

    @vonbbm-du30-bsj59

    3 жыл бұрын

    Absolutely 👍

  • @Mohankumar-vd7ih
    @Mohankumar-vd7ih5 жыл бұрын

    Sir how to give steel bar and how many number ,please explain sir ,you just 4% x section area, how to use 24 sqmm cross section area

  • @satishkumargarg164
    @satishkumargarg1643 жыл бұрын

    Is d effective length or gross length?

  • @JoshuaDetablan
    @JoshuaDetablan4 жыл бұрын

    16 and 1.5 are constant?

  • @KulwantSingh-yw6wh
    @KulwantSingh-yw6wh3 жыл бұрын

    What is d include slab?

  • @johnbenson3174
    @johnbenson31745 жыл бұрын

    24cm2 how does that converts to the diameter of the steel .

  • @MultiJjk
    @MultiJjk5 жыл бұрын

    What about hanging beam? Can i use same formula for hanging beam?

  • @mk.maiappan1608
    @mk.maiappan1608 Жыл бұрын

    Thanks you so much

  • @iacsse6381
    @iacsse63814 жыл бұрын

    Bars must be found according to the dia and tensile strength; decrease or increase the number of bars must be inversely proportional to one another. depth can be up to L/36 [in case of concealed beams. am I right?

  • @keoseyha9390
    @keoseyha93904 жыл бұрын

    good explain

  • @tasadduqmajeed68
    @tasadduqmajeed685 жыл бұрын

    Kindly learn more about the steel area in colum. in the light of formula (Amount of steel).

  • @raufliaquat8424
    @raufliaquat84243 жыл бұрын

    How we know there 5 steel are come in beam and which dia

  • @abimbolaadam6174
    @abimbolaadam61745 жыл бұрын

    Thanks for the tutorial But does this goes the same way with the use of BS code?

  • @balajig4689
    @balajig46894 жыл бұрын

    Final tip- beam length in meter and clear cover in mm ...why?

  • @rrd463
    @rrd4635 жыл бұрын

    Wt. About col. & footing sizes with steel. Regards

  • @Mohankumar-vd7ih
    @Mohankumar-vd7ih5 жыл бұрын

    Sir if length of beam 3 mtr ,what will the depth and bredth sir,

  • @barakshahkakar7466
    @barakshahkakar74665 жыл бұрын

    Great Sir

  • @tokerkhel1491
    @tokerkhel14915 жыл бұрын

    Bahii jan if the dimensions is in feet then?

  • @nagusapavath4268
    @nagusapavath42684 жыл бұрын

    I want how much steel provide.. In KGS & tons

  • @pubgprince6212
    @pubgprince62125 жыл бұрын

    sir here in this vedio you are showing about design of beam only but i need the formula of load calculation about this member....and easy process

  • @ribinraj7609
    @ribinraj76096 жыл бұрын

    ടir pls add Estimation of culvert

  • @ryerakz5991
    @ryerakz59914 жыл бұрын

    Is The length should be clear span?