I Broke These Concrete Beams - Design Principles from Beam Failures

Ғылым және технология

I constructed six reinforced concrete beams in the lab and then loaded them to failure. What can we learn about reinforced concrete behavior and good design principles from these tests?
Two of the beams exhibited flexural failures with lots of flexural cracking and ultimate crushing of the concrete in compression. Two beams had traditional shear failures, with a diagonal crack extending through the section. Finally, two beams had anchorage failures, where the ends of the bars pulled out at the support. Good beam design encourages flexural failures because of its ductility and predictability.
Chapters:
0:00 Beam Fabrication
0:49 Test Setup
1:23 Beam 1 Test
2:31 Beam 2 Test
3:28 Beam 3 Test
4:19 Beam 4 Test
5:31 Beam 5 Test
6:23 Beam 6 Test
7:03 Results
8:15 Lessons Learned

Пікірлер: 165

  • @StructuresProfH
    @StructuresProfH Жыл бұрын

    Studying for the FE or PE exams? Save 15% on exam prep materials from PPI using these links: - FE Civil: ppi2pass.com/fe-exam/civil?affiliate=50524f4648 - PE Civil (Structural): ppi2pass.com/pe-exam/civil/structural-depth?affiliate=50524f4648 - PE Civil (Breadth): ppi2pass.com/pe-exam/civil/breadth?affiliate=50524f4648

  • @jjalandoon
    @jjalandoon9 ай бұрын

    You will have to repeat #5 and 6 beams with rebars extended outside the beam to prevent anchorage failiure.

  • @geraldborja144

    @geraldborja144

    5 ай бұрын

    Yes I agree..or move the 2 supports closer.

  • @josephsylve6758

    @josephsylve6758

    4 ай бұрын

    @@geraldborja144 ​ Indeed that was disappointing...

  • @gaetanguez9154

    @gaetanguez9154

    3 ай бұрын

    Rebars are not supposed to go outside though To improve the anchorage, the end has to form an L shape pointing up in this case Or as mentioned in the other comment, have the points of supports farther away than the end of the rebars ( either by moving the supports or by extending the beam)

  • @MrW416262

    @MrW416262

    3 ай бұрын

    Cog the bars

  • @jayM-bf8eg

    @jayM-bf8eg

    Ай бұрын

    yes i think those hor. rebars are few short to the support area

  • @rinflin7
    @rinflin76 ай бұрын

    I used to had a fear of buildings falling, I used to believe buildings just crack, but this video made me aware that buildings bend and they show signs before falling. Now i can rest well looking at concrete ceiling. Thank you so much

  • @StructuresProfH

    @StructuresProfH

    6 ай бұрын

    A well designed building will bend and show distress before failure. In practice we always try to avoid failures like we saw in beams 3 through 6. If the building will fail, we try to follow something like beams 1 or 2.

  • @randomcrashingfacility31

    @randomcrashingfacility31

    2 ай бұрын

    They can do both.

  • @vanskis7618

    @vanskis7618

    Ай бұрын

    Building have alot of safety factors sprinkled in every step of the calculation

  • @cleisonarmandomanriqueagui9176
    @cleisonarmandomanriqueagui91769 күн бұрын

    best youtube channel for civil indsutry ever . experience is better than theory

  • @OGTennyson
    @OGTennyson9 ай бұрын

    Appreciate this type of content. Keep up the good work sir 🙏🏾

  • @MuhammadYusuf-tr3xe
    @MuhammadYusuf-tr3xe5 ай бұрын

    This has to be the best video I've seen this year, so informative. Subscribing right away

  • @frantisekhladky2784
    @frantisekhladky278411 ай бұрын

    This is very beautiful video. I work 15yaers like structural engineer but when you see it real it si much more better than read in books ! Thanks !

  • @StructuresProfH

    @StructuresProfH

    11 ай бұрын

    Glad you enjoyed it!

  • @ravshanbekmavlonov2996
    @ravshanbekmavlonov2996 Жыл бұрын

    Wonderful beam test and analysis! Thanks for the helpful information.

  • @StructuresProfH

    @StructuresProfH

    Жыл бұрын

    Thank you! I'm glad you found it helpful.

  • @franciscomendoza754
    @franciscomendoza7547 ай бұрын

    I LOVED ur videos, especially this, it's kind of hard to find this kind of material with so much quality and professionalism, would like to see more domestic examples from other countries constructive processes and material, as in Mexico is used a pre fabricated steel elements called Armex, and see the pros and cons of confinement process, or called also load-bearing walls. Greetings guys! Keep the quality

  • @ashishbavdane4353
    @ashishbavdane4353 Жыл бұрын

    Appreciate your effort! Needs more such stuff!

  • @StructuresProfH

    @StructuresProfH

    Жыл бұрын

    More to come! I plan on doing new tests each semester, and I have a few other lab tests in my back pocket that might be interesting.

  • @AlphatecEngineering
    @AlphatecEngineering9 ай бұрын

    Wonderful video teacher, well explained. Thanks

  • @lonewolf4870
    @lonewolf48706 ай бұрын

    Fantastic video, and a question, if you were to bend the rebar ends to allow the ends of the beam to be connected to the bottom of the beam in that way wouldn't that be able to prevent the ancor failure?

  • @phyo2333
    @phyo23339 ай бұрын

    Thanks a lot for sharing prof.H

  • @petewilkinson9681
    @petewilkinson96816 ай бұрын

    Dang, I was excited for beam #6. Would love to see it’s potential after anchorage failure issue is addressed.

  • @StructuresProfH

    @StructuresProfH

    6 ай бұрын

    Working on it!

  • @Structure_Engineering
    @Structure_Engineering7 ай бұрын

    You're great explain led sir we need more video about structure design

  • @mhelmi73
    @mhelmi739 ай бұрын

    Thanks very much Prof. Appreciate it.

  • @dwylhq874
    @dwylhq874 Жыл бұрын

    Hi Prof H, superb test. Very insightful. Instant sub. Thanks! ❤️ P.s: trying to find out info about placing a steel iBeam inside a concrete beam; think it’s called a compound/concealed beam. Are they advisable in a situation with high load? 💭

  • @aseelyousif2341
    @aseelyousif23415 ай бұрын

    Hi, Dr.Broke.. it is amazing veido.. i want to know how you design these beams?? Are you following the ACI cold to determine the dimensions, main reinforced and stirupps ?? Can you let me know . I am interested to know about that. Thanks

  • @Pgan803
    @Pgan8034 ай бұрын

    shear and anchorage more important, we tends to put less emphasis on them. v good

  • @Nick32176
    @Nick321762 ай бұрын

    This experiment more related to a pre-cast design otherwise development length plays a big role here. Top and bottom extra bars are also play a big role in construction. Also at the L2 should have stirrups closer than in the mid section.

  • @nisarahmadriaz3117
    @nisarahmadriaz3117Ай бұрын

    Brilliant dear sir!

  • @ChristianWagner888
    @ChristianWagner8886 ай бұрын

    What was the calculated load capacity of each beam compared to the observed load capacity at failure? In other words, how close do our calculations match reality?

  • @StructuresProfH

    @StructuresProfH

    6 ай бұрын

    For Beam 1, the flexural capacity was about 110 k-in., which should occur at a load of 9.2 kips. We observed about 12 kips of capacity. These calculations assumed nominal material properties for concrete strength of 4 ksi and steel yield of 60 ksi. Measured concrete strength was a bit lower (a bit over 3 ksi), but that barely affects the flexural capacity. We didn't test the rebar, but it was likely to have higher yield than 60 ksi, which would have a major impact on the capacity. Repeating for Beam 2, the flexural capacity was about 162 k-in., which should occur at a load of 13.5 kips. We achieved nearly 16 kips in testing. Beams 3 and 4 had a reinforcement ratio of about 2.94%, but did not have adequate shear reinforcement. Using ACI 318-19 Table 22.5.5.1(c), we would get Vc = 8.0 kips using the nominal concrete strength of 4 ksi. Assuming the stirrups provide no strength (which is reasonable, as they are spaced so far apart), this failure would occur at an applied load of 16 kips. Beams 3 and 4 saw about 14 or 15 kips of load, respectively. If we instead use the measured concrete strength of about 3 ksi, then Vc = 6.9 kips for a failure load of 13.8 kips - that's very close! For Beams 5 and 6, this didn't look like a traditional "shear failure" because of the anchorage issue. However, the estimated shear capacity for these two beams, again neglecting the stirrups and assuming nominal concrete strength of 4 ksi, would be about Vc = 8.0 kips, meaning a failure load of 16 kips. That's pretty close for Beam 5 (failure load of just under 16 kips), but a little low for Beam 6 (failure load of about 18.5 kips). The stirrups maybe provide some help for Beam 6, if only to force the crack to take a steeper incline angle compared to the more traditional shear failures of Beams 3 and 4.

  • @abdullahalfahim6377
    @abdullahalfahim63779 ай бұрын

    Thanks you sir It was a great video

  • @theengineer2020
    @theengineer202010 ай бұрын

    I bet your classes would have been a blast. Unfortunately, i was finishing my masters when you started.

  • @samuelpaitich
    @samuelpaitich Жыл бұрын

    Good stuff. It looks like bearing failures for those last two. A horizontal U-bar or two at each end at the bottom should do the trick

  • @StructuresProfH

    @StructuresProfH

    Жыл бұрын

    That's a good idea, Sam! We have a bunch of extra stirrups floating around our lab, so next time I'll drop a few of those horizontally into the end regions. That is an easier fix than making the beams longer (would need new forms) or moving the supports in (lab floor connections are where they are, and not much I can do about that without fabricating new supports). I really wanted to see a compression-controlled flexural failure, but there is always next time. That would make a good follow-up video.

  • @kcbabu5193
    @kcbabu51934 ай бұрын

    Great content

  • @asifsolanki5412
    @asifsolanki5412Ай бұрын

    Dear Sir, First of all, thank you so much for making such a practical video of structure behaviour after applying load. Would you like to let me know in which software we can make the same animation of any beam and columns carrying load and showing us the results? Thank you

  • @bonjoebeebello2560
    @bonjoebeebello256011 ай бұрын

    Hello, sir! I have a question? How do you determine these failure results such displacement and maximum loading before beam's failure in ANSYS?

  • @aseelyousif2341

    @aseelyousif2341

    5 ай бұрын

    Also me , I want to know how you design these beams?? Are you following the ACI cold of beam design or how you determined the dimensions, the reinforced of longitude and shear?? I hope to let me know???

  • @msamadzad
    @msamadzad Жыл бұрын

    Thanks; please post concrete compressive strengths too.

  • @StructuresProfH

    @StructuresProfH

    Жыл бұрын

    For these beams, the concrete strength at testing was only about 3,000 psi (20 MPa). We did not test the rebar yield stress, which would have a greater impact than concrete strength for the flexural capacity.

  • @msamadzad

    @msamadzad

    Жыл бұрын

    @@StructuresProfH Thank you. 🙏

  • @umarjanzargar2283
    @umarjanzargar228311 ай бұрын

    Sir Which is better to install A girder or a concrte column and beam

  • @user-yr4ho7xk4i
    @user-yr4ho7xk4i Жыл бұрын

    I just discovered your videos and I'm already a big fan. However, I am also an amateur to this. I have a couple of questions that I hope are not too naive. First, have you performed any of these tests with GFRP, a fiber reinforced resin based rebar? The second question is where the more experienced people on here might giggle at me. Would it be reasonable to build a metal truss within the cement? It seems that the amount of metal being used in some of your tests could be made to hold a lot more pressure if it were built in a truss pattern instead.

  • @StructuresProfH

    @StructuresProfH

    Жыл бұрын

    Glad you liked the video! I haven’t tried any tests with GFRP bars yet, but that would be very interesting. In general, GFRP is higher strength than steel but it lacks ductility, so no more ductile yield plateau behavior. It also has lower stiffness, which can mean larger displacements. As for the truss, the beam already kinda does that for you - the steel carries the tensile forces while the concrete carries the compression. So the concrete forms the top chord and the “diagonals” of the truss, while the rebar forms the bottom chord and the vertical members. Sure, you could layout the steel in a truss-like configuration, and it may have really great performance, but the standard rebar “cage” is much easier to build.

  • @acoronas
    @acoronas10 ай бұрын

    Prof H, I'd like to run through the same testing you did on our precast concrete products. What were you using for your displacement sensor, pressure sensor, signal conditioning, and your DAQ?

  • @themagicalmuppet9163

    @themagicalmuppet9163

    6 ай бұрын

    I'm not part of the team that did this, but I may be able to help as I have done these tests in the past (specifically the thirds tests done here). Deflection is usually measured by a laser displacement sensor below the beam or you could use an LVDT for more accurate measurement. For pressure, if youre referring to the force applied to the beam, the test rig (pretty much a specialised hydraulic press) usually has a force and deflection readout. You dont want a pressure readout in these conditions as the diameter of the hydraulic cylinder would then be a factor. The force applied by the press can be halved as shown in the video where P/2 is used to calculate the SFD and BMD for the beam at any point in the test. Some machines can be set to increase the force applied over time, or deflection over time. For both methods, you will know your beam has failed when the force readout reaches a maximum and then starts to decrease consistently, not just briefly at the point where the steel yields (assuming you haven't over reinforced the beam). Using the machine in deflection control is usually much safer. Because once the beam fails, the hydraulic cylinder will just coninue downwards at the same, usually very slow, speed. If you use force control, the machine will speed up after failure trying to apply a higher force. This cannot happen after failure due to the beam no longer being able to resist the ULS force which the machine is now trying to surpass. If/when you conduct these tests, be aware of the very sudden nature in which the beams fail, it can be quite jolting or even quite violent if over reinforced. The over reinforced beams will fail without any warning.

  • @DonaldMorganPolitic
    @DonaldMorganPolitic4 ай бұрын

    I love structural engineering and CAD simulations, but you really can't beat a real world test!

  • @mobilehome5078
    @mobilehome50786 ай бұрын

    Your 10 minute-video is worth more than a few days of reading books for the same info. Thanks

  • @RakeshDas-uo1hl
    @RakeshDas-uo1hl7 ай бұрын

    Can you also explain rammed earth structure failures compared to concrete beams? Which would be the better option and why?

  • @StructuresProfH

    @StructuresProfH

    7 ай бұрын

    I’m no expert on rammed earth construction, so I’m afraid I can’t provide much insight. Sorry. That said, structurally it seems limited to walls and other systems that carry relatively low levels of compressive load and essentially no tension. If it’s stabilized with cement and has some rebar, I presume it behaves much like a low strength concrete or CMU wall?

  • @LTVoyager
    @LTVoyager Жыл бұрын

    It appeared that your supports were at the end of the bottom rebar or even somewhat outside of them. You need the steel to extend well beyond the supports.

  • @StructuresProfH

    @StructuresProfH

    Жыл бұрын

    Yep, I agree 100%. Best practice for simple supports is to terminate the steel at least 6 inches (75 mm) past the face of the support (ACI 318, section 9.7.3.8.1). Though you can't see it, the same supports and bar termination was done for all the beams. This was done improperly here partially for ease of construction and partially to make a point.

  • @jpcraftconstruction.1828

    @jpcraftconstruction.1828

    10 ай бұрын

    Exactly my thoughts

  • @jpcraftconstruction.1828

    @jpcraftconstruction.1828

    10 ай бұрын

    I think in construction, concrete should leave up to 21 days to dry well

  • @LTVoyager

    @LTVoyager

    10 ай бұрын

    @@jpcraftconstruction.1828 It does get stronger with time, but the reason for failure of the stronger beams was the improper placement of the supports which is misleading in regards to which beams likely would have performed best. The weaker beams didn’t have sufficient capacity to overload the points above the supports, but the stronger beams did. This just confirms why the proper balance is important in design. Making one area stronger simply moves the failure to a different place.

  • @jpcraftconstruction.1828

    @jpcraftconstruction.1828

    9 ай бұрын

    @@StructuresProfH oh ok

  • @marcoromanelli6000
    @marcoromanelli60009 күн бұрын

    And now, a video about real buildings where concrete beams are loaded that way...

  • @ahmednmansy8121
    @ahmednmansy812111 ай бұрын

    Thank u prof❤

  • @Laguna2013
    @Laguna20135 ай бұрын

    what does anchoring at its ends mean?

  • @edgiecatangay3492
    @edgiecatangay34922 ай бұрын

    Architect here! I have a question does the type of hook provided in the stirrups matter? And how does it affect the Shear capacity of the beam?

  • @StructuresProfH

    @StructuresProfH

    2 ай бұрын

    As a general rule, a 135-degree hook is better than a 90-degree hook. However, we typically assume that the hooks in the stirrups don't matter for capacity, so long as they satisfy prespecified "standard" hook conditions. So for example, ACI Table 25.3.2 has standard hook geometry for stirrups - as long as we are following (or exceeding) that, we assume we get the full design capacity from the stirrups. However, there are some conditions where the type of stirrup hook may be more important, like for seismic design (ACI Section 18.6.4) or for beams carrying torsion (ACI Section 25.7.1.6). Again, we treat these prescriptively - the stirrup hook geometry doesn't factor into our design calculations so long as our hooks meet the standard.

  • @charlessyrus6175
    @charlessyrus61755 ай бұрын

    Thank You

  • @ehinspections
    @ehinspections Жыл бұрын

    Thanks for sharing! Your tension bars do not appear to have been developed; need to hook them at the ends.

  • @StructuresProfH

    @StructuresProfH

    Жыл бұрын

    Yep. Our other idea, for next time, is to add some horizontal stirrups at the ends, mainly because we have a bunch sitting around the lab.

  • @ajazahmad2844
    @ajazahmad28444 ай бұрын

    Why didnt you bentup the bars i think by doing that edges of beam wont show signs of failure if you add hoop reinforcement as well

  • @user-dx8ih4hb1o
    @user-dx8ih4hb1o6 ай бұрын

    What is the gap or inches of beam 2

  • @a.azizsm9363
    @a.azizsm93637 ай бұрын

    Changing the rebar iron with high tension cable will make more strength?

  • @StructuresProfH

    @StructuresProfH

    7 ай бұрын

    Possibly, yes. Moment capacity requires a balance of tension (in steel) and compression (in concrete). With low strength concrete, you might not get that much benefit from high strength steel, especially if you can’t yield the steel to use it to the fullest. Plus, in practice, higher strength materials may run into serviceability or deflection issues - high strength does not always mean high stiffness (for example, all steels have roughly the same elastic modulus, regardless of strength). It may hold the load just fine, but have unacceptable deflections.

  • @arulpiragasamamalraj5248
    @arulpiragasamamalraj524811 ай бұрын

    ❤thank you

  • @javi5381
    @javi53819 ай бұрын

    i learned from this..

  • @alconchek
    @alconchek2 ай бұрын

    You will have much more shear breaking in short beams and momentum breaking in long ones

  • @montanaplease
    @montanaplease7 ай бұрын

    How is it that nobody’s pointing out in the comment section that they use the a concrete truck for this little bit of concrete 😂😂

  • @StructuresProfH

    @StructuresProfH

    7 ай бұрын

    One cubic yard! Yeah, it’s a ridiculously small load, but our concrete supplier is really great about this kind of stuff. It’s certainly easier than mixing by hand (don’t have a drum mixer with this capacity).

  • @allnamesaretakenb4
    @allnamesaretakenb47 ай бұрын

    "For you folks in metric" literally everybody outside the US, and a bunch inside the US.

  • @StructuresProfH

    @StructuresProfH

    7 ай бұрын

    Shout out to the rest of the world, and thanks for watching! I'll always have a place in my heart for English units though.

  • @MeShow168
    @MeShow1682 ай бұрын

    Load on beam ❤ beam test

  • @lulusukkar1324
    @lulusukkar13243 ай бұрын

    Thanks...... The reason for the collapse of the beams in all cases is crushing in the concrete, right?

  • @casanova6734

    @casanova6734

    Ай бұрын

    Brittle failure at the beam ends also

  • @JoyousOblivion
    @JoyousOblivionАй бұрын

    Would have liked to see tests 5 and 6 repeated so we can see actual results without the testing environment being the failure cause. Also, when the rebar was placed into the forms, I didn't notice any spacers/chairs on the rebar to prevent it being to close to surface. Were those intentionally left out, or were they just not visible on camera?

  • @StructuresProfH

    @StructuresProfH

    Ай бұрын

    I agree. I actually did try these two tests again recently, with three horizontal stirrups/ties placed at the each end above the supports. Ideally, these should have bridged the split that formed at the beam ends. Long story short, it didn't work out, and I got the same failure mode again! Didn't publish a video on it, as I didn't think it added much value. Just goes to show that there is no substitute for good rebar anchorage at the ends. As for chairs, yes they are there, but rather hard to see. Concrete cover is lower than would normally be acceptable for code (only 0.75 inches), on account of the beam's small scale and these not actually going into a building.

  • @mcniulian
    @mcniulian3 ай бұрын

    You should have bended the rebars at a 90 degree angle at both end of the beams

  • @skablerpro
    @skablerproАй бұрын

    It seems to me like beam 5 needs to be longer. The weight can't break it at the center so it breaks it at the end since thats where the opposing force is

  • @tehsoonguan9343
    @tehsoonguan9343 Жыл бұрын

    Cool !

  • @StructuresProfH

    @StructuresProfH

    Жыл бұрын

    I agree :)

  • @LawrenceLarson-ln8yy
    @LawrenceLarson-ln8yy6 ай бұрын

    It kinda looked like the concrete failure didn't split the aggregate. Weak concrete? At What psi did the cylinders test / break?

  • @StructuresProfH

    @StructuresProfH

    6 ай бұрын

    It was indeed weak concrete. Cylinders broke at just over 3000 psi (~21 MPa).

  • @anubhab_IITG
    @anubhab_IITG10 ай бұрын

    Firstly, Very Interesting Demonstration. Sir, I have a query. In case of beam 6, although the number of stirrups are sufficient and closely spaced enough why are we having shear failure despite having shear capacity to be on higher side? Also, why the main longitudinal bars are pulling out? are those not properly anchored and embedded in the concrete? and also, Why shear failure is coming in beam 6 even though we have enough shear capacity. I will be glad if you can please elaborate and resolve my query.

  • @StructuresProfH

    @StructuresProfH

    10 ай бұрын

    The longitudinal bars for beam 6 are definitely not anchored properly. They have a relatively large diameter, no hooks or anything to keep them in place, and the end of the bar was directly above the support. Ordinarily (and per ACI 318 code) you would need these bars to extend at least 6 inches past the face of the support. Once the bar started to pull out, it initiates into a shear-like failure. Though some of the simplified code equations for shear capacity neglect it, the longitudinal bars do play an integral role in developing shear capacity; in this case there was effectively no longitudinal steel area at the ends after bar pullout. I call it "shear-like" because unlike a traditional shear failure, which would be expected to follow more of a diagonal crack path, the crack extended at a very steep angle from the support. So I guess I'd call it more of a combined anchorage-bearing-shear failure, but initially caused by the poor anchorage.

  • @anubhab_IITG

    @anubhab_IITG

    10 ай бұрын

    @@StructuresProfH Sir, you meant at the support end stirrups were not there to anchor the longitudinal bars? Otherwise it would not have undergone pull-out. However, I meant enough shear capacity in the sense that stirrups provided were sufficient enough to provide shear capacity. Since, the bars pulled out at first place due to ineffective anchorage the stirrups didn't play any role. Am I correct?

  • @camzryan
    @camzryan11 ай бұрын

    7 days?😂

  • @omviuvenitlalumina
    @omviuvenitlalumina5 ай бұрын

    no vibration????

  • @jhunmagnum6897
    @jhunmagnum689710 ай бұрын

    Nice

  • @chrisk7118
    @chrisk71187 ай бұрын

    Did you wait 28 days for it to cure fully?

  • @StructuresProfH

    @StructuresProfH

    7 ай бұрын

    Yes. To clarify, we did a wet cure in the forms for 7 days. After 7 days, we removed the beams from the forms, but they were not tested until just after 28 days. To be fair though, many concrete structures in practice are loaded at ages much earlier than 28 days, despite that being the “standard” design strength. Strength gain is not linear. You gain most of the strength within the first week, but you can also gain strength (very slowly) for a year or more.

  • @chrisk7118

    @chrisk7118

    7 ай бұрын

    @@StructuresProfH Fantastic, thanks for sharing this video!

  • @ausgamingchannel432
    @ausgamingchannel4323 ай бұрын

    tie the iron link like a fool tie, and there are too many cavities in the beam

  • @gustavobentancort2257
    @gustavobentancort22573 ай бұрын

    u need make negative iron for strong resist

  • @abdwall3910
    @abdwall39108 ай бұрын

    جيد شكرا

  • @onintheexplorer
    @onintheexplorer2 ай бұрын

    it is need a cranked bar to avoid bending the beam

  • @kspradeep8397
    @kspradeep83974 ай бұрын

    5 & 6 beams didn't fail but the testing equipment failed actually

  • @bobjoatmon1993
    @bobjoatmon19934 ай бұрын

    And consider that these beams were otherwise constructed with care, out in the wild partiality skilled labor and / or poor quality materials further reduce the strength of the construction.

  • @dule-iz5lz
    @dule-iz5lz6 ай бұрын

    Lớp trong sắt dài, chịu lực ... Mà chỉ có. Vài sợi dây Fe mỏng vài zem

  • @george_davituri
    @george_davituri7 ай бұрын

    Interesting 👍🏻🏗

  • @StructuresProfH

    @StructuresProfH

    7 ай бұрын

    I agree!

  • @futurepilot6749
    @futurepilot67499 ай бұрын

    7 days only?

  • @StructuresProfH

    @StructuresProfH

    9 ай бұрын

    Sorry, I realized I wasn’t clear on that in the video. We removed the beams from the forms at 7 days but tested at 28 days.

  • @mansgottaeat1298
    @mansgottaeat12984 ай бұрын

    Pushin P

  • @yuribarrientos1984
    @yuribarrientos19844 ай бұрын

    Need matches with. Theory?

  • @samsung-eh4dv
    @samsung-eh4dv5 ай бұрын

    Brotha for accurate test you suppose to do a 7 day, 30 day and a 60 day. Those are thick so it’ll probably take a little longer to mature. 7 days is not a lot of time to mature.

  • @ChrisSmith-bg3eo
    @ChrisSmith-bg3eo5 ай бұрын

    5 and 6 must be the strongest because the failure occur where the steel and bars end 🤔

  • @Anandengineer
    @Anandengineer7 ай бұрын

    Can i use your videos to my channel to explain the same in my regional language

  • @StructuresProfH

    @StructuresProfH

    7 ай бұрын

    Sorry, I would prefer not. My videos are not licensed under Creative Commons.

  • @edwincamaclang7858
    @edwincamaclang78583 ай бұрын

    Insufficient reenforcement that's why having a cracking concrete

  • @oswald2358
    @oswald235810 ай бұрын

    Great

  • @StructuresProfH

    @StructuresProfH

    10 ай бұрын

    Thanks!

  • @jorgecarrillo2
    @jorgecarrillo27 ай бұрын

    beam 6 Failure was due tot he fact that Steel is not over the points stress and the Concrete Cracks.

  • @abogunrinjamesolalekan4422
    @abogunrinjamesolalekan44225 ай бұрын

    Is a misleading video 😢. When you didn't extend and anchor your reinforcement accurately, what do you expect?

  • @zohaibhasan1070

    @zohaibhasan1070

    Ай бұрын

    Was thinking same

  • @franciscodupetit8780
    @franciscodupetit87803 ай бұрын

    hay muchas cosas que decis que no estan bien teoricamente

  • @SimaoTatiLubendo
    @SimaoTatiLubendo4 ай бұрын

    🇦🇴🇦🇴🇦🇴🇦🇴🇦🇴🇦🇴🇦🇴🇦🇴It Is incredible ; test well done; work done sucessfull

  • @ferenczbabinszki7699
    @ferenczbabinszki76992 күн бұрын

    i thought you're supposed to waith at least 28 days for proper cure?

  • @StructuresProfH

    @StructuresProfH

    Күн бұрын

    Sorry, I wasn’t clear in the video. We did a wet cure (with burlap) for 7 days. We tested roughly one month after casting. That said, there are many applications in the real world where concrete is loaded well before 28 days, and concrete will continue to gain strength even after 28 days. It’s more accurate to say that 28 days is the laboratory standard.

  • @aaryansingh-gx6ll
    @aaryansingh-gx6ll9 ай бұрын

    Upload this in p df format

  • @dineshvyas
    @dineshvyas3 ай бұрын

    Your Stirrup bending doesn't follow standards, and vertical bars should overlap columns bars. These are not actual stress conditions for beams.

  • @arabeahmad1266
    @arabeahmad12663 ай бұрын

    ❤❤

  • @deepurajput7545
    @deepurajput754511 ай бұрын

    You need more study

  • @johnd.relaxmed6097
    @johnd.relaxmed60979 ай бұрын

    I dont know what is the logic of putting your support at a very edge of that beam where there is no steel. 🤨ofcourse it will crack in that position.

  • @tdta6864
    @tdta6864Ай бұрын

    Hey, can you make a video commenting these overspec foundations: kzread.info/dash/bejne/gKCZysSNaN2seMo.html Do you think they have some wild expansive clay like in texas?

  • @loola456
    @loola456Ай бұрын

    Moments were not my thing st all.

  • @thatWanderingSoul
    @thatWanderingSoul7 ай бұрын

    Use more steel. Simple

  • @StructuresProfH

    @StructuresProfH

    7 ай бұрын

    We definitely could have used more steel at the end of Beam 6 for sure! But it’s not always so simple. If Beam 6 had proper anchorage at the ends, it probably would still have had an undesirable failure mode - compression controlled flexural failure. Such a failure is brittle. The steel will not yield, meaning there is such a thing as too much steel.

  • @RK.Lalchungnunga6257
    @RK.Lalchungnunga62578 ай бұрын

    ❤🎉

  • @Muscleupsanddangles
    @Muscleupsanddangles2 ай бұрын

    4 valid tests and a bunch of wasted time and material for 2 more tests

  • @construction02
    @construction029 ай бұрын

    ❤❤❤❤❤❤❤❤❤❤❤❤❤❤

  • @bullthatsalive9111
    @bullthatsalive91116 ай бұрын

    Cool test poorly done concrete tho.

  • @StructuresProfH

    @StructuresProfH

    6 ай бұрын

    Thanks for watching! But yeah, we are definitely not professional concrete masons.

  • @andrewells7441
    @andrewells74416 ай бұрын

    How in the hell is this demo credible? Only a fool would build rebar in such a way where it does not tie into any supporting columns or rebar structure on the ends? I just don't understand why the rebar did not extend longer to the end of the form? This makes the demo dubious!

  • @StructuresProfH

    @StructuresProfH

    6 ай бұрын

    Improper anchorage is part of the point of this demo. You don’t really need any “structure” at the end of a simply supported beam. The rebar just needs to extend far enough past the support (6 inches per ACI-318), among other checks for development length that are difficult to satisfy for such large bars. Obviously, that wasn’t done here.

  • @middleway1885
    @middleway18858 ай бұрын

    Boop

  • @user-op9zi2kt5c
    @user-op9zi2kt5c5 ай бұрын

    I did not learn anything from this video

  • @Indianpharaoh1

    @Indianpharaoh1

    Ай бұрын

    This was for fun purpose.

  • @-RahulHarne

    @-RahulHarne

    Ай бұрын

    Yes bro ❤

  • @bradd8841

    @bradd8841

    18 күн бұрын

    The purpose seems to be simple visualization and way to engage with a real world beam.

  • @alokkumarbharagava

    @alokkumarbharagava

    11 күн бұрын

    😂😂😂😂

  • @user-ev7kb9hu1h
    @user-ev7kb9hu1h8 ай бұрын

    there should have been proper stirrup. and the #5 failed because the steel is short . it cracked at the very end where the steel ends. meaning the load and stress where only in the concrete . not the steel.

  • @poorguy9720
    @poorguy97209 ай бұрын

    After 7 days I can break ur beam with my bare hands. Ur beam didn't hv support of rings.

Келесі