Symmons Temptrol Spindle Replacement

Тәжірибелік нұсқаулар және стиль

How to change a TA-10 spindle on temptrol valve body. This is not a full rebuild, I'm not worried about the seats. It's a hotel, just get it done.

Пікірлер: 7

  • @helens.2409
    @helens.24093 ай бұрын

    You’re the best ❤

  • @oumuamua717
    @oumuamua7172 жыл бұрын

    Do you have to shut down the water main??

  • @JoshuaYell

    @JoshuaYell

    2 жыл бұрын

    If you have the residential valve body that does not have hot and cold control stops behind the escutcheon plate, then yes. Remove the plate and if you see a slotted screw on either side of the spindle then you can run those in all the way clockwise and shut the water off right at the valve. Sometimes those freeze up and you have to shut the main anyways. If you do not have screws on either side then go ahead and shut the main. Weather you have stops right there or not the rest of the process is the same.

  • @seanshields86
    @seanshields86 Жыл бұрын

    What screwdriver is that? I likey

  • @JoshuaYell

    @JoshuaYell

    Жыл бұрын

    The cordless driver is a Skil SD561201 and the 11 in 1 is a Wiha 77891. Highly recommend both.