Kenmore Elite Washer F35 SUD Error - Voltage Checks to Better Determine Cause

Тәжірибелік нұсқаулар және стиль

www.f35error.com - If you’re getting the F35 and SUD errors now here is a quick check to see if it is your CCU or analog pressure sensor, or APS. If your APS’s output is reading is low then I would repair or replace your APS. My failed W10415587 APS sensor was reading .161 VDC instead of .380 VDC and would cause the F35 and SUD errors. I am creating APS repair kits so you can fix your APS in 99% of cases. Check back soon…
If your CCU’s 5VDC rail reading is not stable or is -/+ 0.3 VDC then I would recommend the F35 error repair kit. Note: If your 5VDC rail is low then the output of the APS will be lower because the pressure sensor i.c.’s output is ratiometric.
If your CCU 5VDC rail reading is good then I would recommend proactively upgrading your grey CCU components to prevent future F35/ SUD errors. See www.f35error.com for kit.
I also provide bearing and seal kits for your washer for when it is sounding like a jet taking off. It is best to catch the bearing and tub seal failure early as possible. See www.washerbeari....
Don’t forget to subscribe and leave any questions below…
Thank you,
Jeff Hartman
“The Neptune Man”
P.S. Visit www.breakthroug... to experience a 14 day training on a work at home solution - no cost - This will change your life!

Пікірлер: 4

  • @timothyjaca8544
    @timothyjaca85448 жыл бұрын

    Great video. Very helpful. One thing that I notice when taking my voltage measurements is that I get the .38 volts from terminal 1 to 2 with the power off to the washer i.e. plugged in but the power button not pushed. When I push the power button, my voltage goes to 1.19 volts from terminal 1 to 2 on the CCU. What does this mean? Is my pressure switch bad or is the CCU going out on me? Thanks again for the great videos.

  • @neptunewaxmotorcom

    @neptunewaxmotorcom

    8 жыл бұрын

    Hello, in your case it looks like a CCU issue. From my experience with past clients the F35 Error Repair kit at www.f35error.com will fix your F35 error code issue. Thank you, Jeff Hartman "The Neptune Man"

  • @larrydevincarter
    @larrydevincarter8 жыл бұрын

    Hey Jeff. I'm hoping you can help me. I get the sud f35 error. I've checked all the hoses and replaced the sensor. When I check pin one and two I get .433 V but as soon as I turn the power on it shoots up to 1.185 V. The 5V supply read correctly. What might this indicate? The tub never get a chance to fill as it goes into error shortly after starting the cycle.

  • @neptunewaxmotorcom

    @neptunewaxmotorcom

    8 жыл бұрын

    +Larry Carter Hi Larry, it sounds like your CCU power supply needs corrected with my www.f35error.com kit. The 5v CCU power supply is always on then when you turn on machine other circuitry starts to draw more power and that disturbs the 5v rail. The APS seems to be sensitive to the 5v rail because the actual pressure sensor has a ratiometric output which makes it sensitive to the input voltage (5V rail) I hope this helps. Jeff Hartman "The Neptune Man"