This is the coolest thing I've found. Great work on the videos. Cheers.
I was looking to learn about hydraulics for a dyi - thank you! Your clips are amazing. You're a good teacher.
Very well explained . Ive experienced this very thing . On a 20 tonne Cat excavator we had a thumb installed and used a old Hitachi boom lift ram off a 10 tonne Hitachi . The Hydraulic hose guy we got to plumb it up only used 3/8 hose and a 3/8 cross line relief valve . The bucket hoses on the Cat were 3/4 . When grabbing a lot of trees and rubbish the cylinder shattered in half. We replaced it and it did it again about a week later . We got and expert hydraulic man to take a look and he replaced everything with 1/2 inch and the problem went away . The oil just could not return fast enough through the 3/8 system . The danger of using people that know enough to be dangerous and a costly lesson . The technician that fix it said that it could have cause a spike as much as 20000 psi inside the cylinder . Just completely chopped it in half
You are doing a great job! Super clear explanations.
You are a remarkable and effective instructor. Thank you!
This video is incredibly informative! Thank you for making it!
Very informative and quite interesting. From your demonstration, it's easy to see how you could generate too much pressure in a hydraulic cylinder especially when it bottoms-out. A very dangerous situation. Thank you.👍🏽🤠 4/10/23
Great explanation! Very easy to understand this. Since there is less surface area of the side with the restrictor due to the piston rod, that side will build a higher fluid pressure to balance the push against both sides of the piston. However, I think that the less the restriction of flow, there is more relief to reduce the higher pressure differential. I find that there are one-way flow restrictors to eliminate need to a directional bypass. I had to subscribe.
This is really an awesome video.Its going to help in my designs.Thanks for the great work
Great presentation, very clear and accurate. 🇬🇧
Thanks... It helps me a lot...i'm studied electrical but now works in mechanical and starts hydraulic...
very good information and presentation. well explained thank you and keep them coming
Excellent illustration
Bravo.Clean and crystal clear 🤝 It would be a great help if you teach us how to manufacture a Double acting cylinder. With circuit Diagrams,Design & material selection.
Great video!! We love hydraulic repair down in Alabama.
That was super easy to understand. Thank you
Thank you for the good simplified information. I liked you accent.
Very good demonstration. Thank you 🙂
Awesome job!
Great explanation. Very clear. thank you.
thanks sir, a very good idea.. we exploded one cylinder twice by giving more pressure in extraction and now only i came to knew why.. nice job. upload more videos.
This is awesome, thank you very much
Very good, I've learned a lot. Thank You.
Excellent video and explanation thank you🤘
Very helpful. Thank you so much!
Nice explanation. Great safety glasses.
@roberthickey7616
3 жыл бұрын
Hi , by changing a bucket hydraulic cylinder ,do 8 have to bleed lines. I used my tractor to blow wet snow an things worked for about 5 hrs, then lost pto lift an bucket lift. Any thoughts on what I should look at to trouble shoot an fix. Thanks R9b
Very good video. clear and easily understood.
Great! Thanks allot for that video
One word, actually three - Very Good Teacher
Good training for learning stage peoples thank you very much
Heartfelt thanks for unselfish sharing your knowledge Sir!
Very good videos, have you changed your page as I notice you haven't posted any videos in a while? Also is this pressure increase ever used on purpose?
thank you very much for your video
Very clear and informative.
There actually is one very good reason to use a meter out flow control valve. If you have an overhung load on the cylinder (the load can pull or push the rod), with meter in, the load can produce a vacuum within the cylinder and travel unexpectedly. With meter out, it will be fluid locked and can not be pushed or pulled by the load. Much safer. Just use components capable of handling the pressure.
thank you, very good video
ive watched this a few times, i understand your correct way of limiting the speed to the back of the cylender, but you only showed the 'wrong' way to attach the flow control valve to the top end. IS the correct way just the other way around? (if i want to limit the retraction speed - to make them the same) i'm hoping to make my own little excavator. many thanks for these videos they are so great and helpful cheers from the UK o/
super dear lot "love" from Jammu(india)
Amazing well explained
Good teacher.... Give us more
thank you bro for your explain ❤
Thank You very much sir !
Awesome!
GREAT CONTENT !! BLESSINGS!!!
you are awesome
These videos are great!
thank you thank you
Well said!
An excellent instruction video. I do detect a NZ accent.
U r great....😎
អគុណបងthank
Thanks a lot.
well done
Man your good
love it
Thanks for your help! hydraulic-master
Thx this was insightful….wonderful explanation
Very interesting
Wonderful wo
非常好
Is there a way to reroute your ram end pressure line with a relief valve on return to valve bank that would push that oil straight back into the base end of the cylinder for a faster extending of the ram ?? Kinda like an ER system
Very good teacher
Good knowledge
nice
Great video! Especially that you used actual components rather than teaching via a drawing on the white board.
How is the pump relieving pressure when the hand valve is in the neutral position? Is it going through the hand valve back into the tank, the red line?
Is the control valve you are using a TANDEM CENTER control valve?
I want to build a hydraulic system and I need t work out what size pump to use...I got a 6 horse power Kubota diesel...that is the starting point...I am building a log splitter maby one 30 ton cylinder ....do you have a video to explain
In this configuration, what kind of distributor valve are you using ?. Thank you
Maximum stroke per minute of hydraulic double acting cylinder.??
Is there a way pressure intensification can be put into good use?
Cool! Ok so how do you maximize the speed in both directions (and have them at least the same) to get the fastest cycle times? Also, what effect does speeding up the cycle have on the max force that a cylinder can generate?
@CustomHydraulics
3 жыл бұрын
To maximize the speed in the extension direction you would have to adjust the circuit to make it a regenerative Circuit. Regenerative Circuits increase the extension speed of a double acting cylinder by taking return oil from the rod end and use it in the piston end to speed up extension. but in a regenerative circuit reduced cylinder force is a major disadvantage.
@ahitchcox
2 жыл бұрын
@@CustomHydraulics I don't know of any way to "adjust" a basic circuit into a regenerative circuit. You'd have to redesign it. Besides, a regen circuit is most effective only when the piston diameter to rod diameter ratio is greater than 2:1. The simplest way to achieve equal force for extension and retraction is a to use a double rod end cylinder-and it may not require redesigning the circuit. To achieve the same extension force as with the single rod end cylinder, you'd have to use a double rod end cylinder with a slightly larger bore. There are others ways, such as using a flow combiner, but they would require redesigning the circuit.
Really goog but what's about rod end and head end instead of back side and front side of cylinder....does it make sense ? Just wondering.
My question is more about rotary actuator speed control not so much as linear. Quick question....most people discuss hydraulic motor RPM off the reference to an electric motor driven pump. I understand that hydraulic motor speed is established off volumetric flow. Since most pumps are driven off AC motors they tend to have a set RPM which in turn produces a set GPM output flow. This in turn results in the hydraulic motor having a set RPM if not controlled by some form of restriction valves. However, in the case of a gasoline or diesel power engine driving the hydraulic pump....don't we gain greater control over the RPM of the hydraulic motor, by controlling the engine RPM since that should change the GPM of the attached hydraulic pump?? I guess what I'm asking is if we slow down or speed up the RPM of the pump we would essentially be decreasing or increasing the supplied GPM at the motor and effect the speed.....correct??
@ontheroadagain4773
2 жыл бұрын
Directional control valves are usually proportional, which means you can control the speed pretty well by the lever. In this case you definitely don't need any restriction valve that unnecessarily increases the pressure, that in turn heats up the oil, wastes energy and causes wear to the pump. And the answer to your question is Yes. - But by using a combustion engine you can't control the hydraulic motor from zero speed without a control valve.
Is there a flow control valve to regulate even flow to 4 cylinders at once? I'm trying to make/operate 2 scissor lifts simultaneously to lift the rear of a truck up 20" to dock height. So 1 scissorlift on each rear corner of the truck and 2 cylinders on each scissorlift. They'd be driven off a drive powered by a 12vdc battery. I'm not far into planning this yet so.....
@CustomHydraulics
3 жыл бұрын
Hi David, there are methods such as using flow divides or phasing cylinders that allow for almost even extension speed of cylinders. For the application you described however it sounds like you will need some electrical control/monitoring and would best off consulting an expert for assistance.
Hi Im looking to alter a hydrauic function on my mini digger and wondered if you would possibly help reading a hydraulic schematic for my machine?
Can I see which type of lift you made which is your behind
very helpful videos, but i have challenges controlling the swing speed of an FFLB crane, i notice that there are variable voltage soleniods that also control speeds of hydraulic flow and cylinder movements. pls have you come across such solenoids??
@Danny_man
Жыл бұрын
Look up PWM….
Hi, is it possible to use a Hydraulic cylinder as an oscillator at 150Hz?
what do I need for a 2 ton ram please
I have a small trailer that has a hydrolic hand jack to raise turn lever and it goes down I am changing to a hydraulic cylinder with hoses to run back to valves on my sub compact tractor. What kind of cylinder do I look for to raise and lower bed ? Wagon capacity is 2000 lbs
@CustomHydraulics
3 жыл бұрын
Hi Roy, we would like to help you with your questions - we gathered questions, like this, for our live Q&A tomorrow. Join us there and we might answer this question for you: facebook.com/events/176497570992728/
Sir how to solve automatic level for genie boom lift problem can you teach
way of your teaching is good, the another person on this channel is bit difficult to understand due to acsent
How fast can you make one go
2:30 I was not prepared for this level of violence. A content warning may be necessary.
One question i have an electric dual hydraulic pump but need to use on a single cylinder can i still manage to use the dual hose electric pump with that single cylinder? Is there a y adapter that can make that possible?
@CustomHydraulics
3 жыл бұрын
Hi there, we are doing a live Q&A tomorrow at 7:30am (NSW) - join us live and we might answer this question for you. Join us here: facebook.com/events/176497570992728/
at the end, he placed the control valve and check valve in series, but the circuit on the board shows they are in parallel. or I'm wrong somewhere?
@spice4lyf799
5 жыл бұрын
I noticed the same thing. If he installed the valve like he had it on the board I thought it would have stopped the flow creating the 150 bar without him needing to close the valve..
Ok, got a question. My backhoe stabilizer legs are WAYYYY too fast retracting and dangerous. How can I slow them down ?
@darrenwoodruff3256
5 жыл бұрын
i have same problem with my digger arm working to fast .i was hoping to see some sort of method to slow hydraulic speed down
What if there is no valve, like machinery have? What if it was a hydraulic system in an animatronic?
so meter out is not the way to go, it will increase the pressure, build up heat which is not good for the system i suppose, correct me if i am wrong, thanks.
I think you say preassure unit is bar while it is psi. Could you confirm please?
@1337mofo
6 жыл бұрын
100 bar is 1450.38psi
How would you speed up overall operation without changing the pressure of the system?
@CustomHydraulics
3 жыл бұрын
Hi Fred, pressure in a circuit effect the force of actuators, if you want to change speed, you need to change the flow in the system.
@Stumproad
3 жыл бұрын
APT Specialist Hydraulics and Training is there a way of changing the rate of flow with out changing the the size of the pump or the motor that drives it. Or would you just have to change both to increase the speed of the cylinder?
when you restrict the follow of oil does that cause the oil to rise in Temperature. ??
@JesusMartinez-mi5oh
5 жыл бұрын
Gary Hall yeah, the temperature increases because you are wasting energy. All the energy that is not used to perform work, will be transfomed into heat. It is way better to design a system where you do not need a flow regulator. If you need to, it is quite possible que you will have to install a heat exchanger
@garyhall867
5 жыл бұрын
Do you know what your talking about ???????????????????????
@MrSaemichlaus
4 жыл бұрын
@@garyhall867 Yes he does exactly. Consider the possibility that it is you who can't follow.
@SegoMan
Жыл бұрын
@@garyhall867 Yes when you tell the smart hydraulic oil to slam into the dumb hydraulic oil it creates friction which in turns raises the working temperature in the containment vessel..
Dear sir, Firstly if we close rod end of this piston then we put pr in a confined hydraulic so how pr is increases? Also as the system pr is same for area difference of the piston head end & rod end force is different but pr should be same. I still not understand how pr increases? Plz explain anyone.
why not increase surface area on the other side by reshaping the back of the piston in an angle increasing its area
@robwells354
7 ай бұрын
It’s not the piston area but the fluid volume that causes the pressure difference
I am working on a project. Can you help me.
Thank you for these lessons, but what is the point to make videos and not answering to the questions ?
if the flow control valve cum check valve piston side flow control valve rod side.how i increase the forwerd and reverse speed of the cylinder if pump not change.
@CustomHydraulics
3 жыл бұрын
Hi Gurdeep, we want to help you and answer your question. We are doing a Live Q&A tomorrow at 7:30am, join us live there and we might answer this question for you: facebook.com/events/176497570992728/
This is a very informative video, especially with your real-world demonstration. But you should really use standard ISO symbols to represent all components. These standard symbols not only denote specific components, but also illustrate their functionality. This makes it immediately clear what specific type of valve we're using without having to define or explain anything. Also, standard terminology - like rod end and cap end - should be used in describing the cylinder instead of front and back. We all need to be able to communicate by speaking the same language.
you had that metering valve hook up in series you hook up not like your drawing there not same