HOW TO FIX GAS LEAK IN A FREEZER ROOM CONDENSER UNIT.

Тәжірибелік нұсқаулар және стиль

This is a freezer room condenser unit, it has a Dorin H281CS COMPRESSOR.
the problem is not cooling. it was a gas leak. a gas leak between the filter and the sight glass.

Пікірлер: 33

  • @tonyp6088
    @tonyp60884 ай бұрын

    Ok nice video. Just a few little suggestions for you. Firstly when braising you must use dry 😊nitrogen to prevent pipework contamination. Secondly always remake leaking flares. The sealing surface is the copper flare and not the thread on the flare nut. Putting sealing compound on the threads does nothing towards maintaining a good seal. A tiny bit of nylog or refrigerant oil on the mating surface of the flare would have been a better idea. Great video though. Well explained 👍👍👍

  • @sanjeewachathuranga3215
    @sanjeewachathuranga32154 жыл бұрын

    i recommend this channel to everyone who in technical field or need to fix a machine.Great work and keep it up.❤️

  • @unarinemurathi666

    @unarinemurathi666

    2 жыл бұрын

    But why did he install service valve?? why did he vacuum while charging the system?? i thought he pumped down the gas

  • @konainggyimm
    @konainggyimm2 жыл бұрын

    I love it 🤩 Thank u for your video.

  • @Shan-wx9xo
    @Shan-wx9xo4 жыл бұрын

    Oh yeah! This is a great review of how a good job is done ✅ excellent job 🤜🤛

  • @youtechjb4361

    @youtechjb4361

    4 жыл бұрын

    Thank you dear ❤

  • @youtechjb4361

    @youtechjb4361

    4 жыл бұрын

    Thank you dear❤

  • @gerardochieng4097
    @gerardochieng40972 жыл бұрын

    How do you vacuum the system while all the valves are closed? and while charging, do you use the high side of the gauge or the low side? Kindly help, new tech in the field please.

  • @MusicLife-sf7gn
    @MusicLife-sf7gn4 жыл бұрын

    It's really helpful. Great work.👍

  • @youtechjb4361

    @youtechjb4361

    4 жыл бұрын

    Thank you dear 😍

  • @syedbasheer8210
    @syedbasheer82103 жыл бұрын

    Subscribed😎..keep them coming

  • @karaors8970
    @karaors89702 жыл бұрын

    Nice Job 🇹🇷👍🤳🛠️

  • @palanivel-yx3qi
    @palanivel-yx3qi Жыл бұрын

    Nice

  • @user-ck8kg4gu8n
    @user-ck8kg4gu8n4 жыл бұрын

    සුපිරියි 👍

  • @youtechjb4361

    @youtechjb4361

    4 жыл бұрын

    Thank you dear😍

  • @bishnumahata1585
    @bishnumahata15853 ай бұрын

    🎉😂

  • @palanivel-yx3qi
    @palanivel-yx3qi Жыл бұрын

    Work is fine

  • @buynow1087
    @buynow10874 жыл бұрын

    Amazing 👌

  • @youtechjb4361

    @youtechjb4361

    4 жыл бұрын

    Thank you dear😍

  • @omidamiry4109
    @omidamiry41093 жыл бұрын

    Why install servis valve?? We can't vacuum from compressor valve??!

  • @nehalraza57
    @nehalraza57 Жыл бұрын

    Plss explain as well as,,

  • @dcwhite5568
    @dcwhite55683 жыл бұрын

    What is the compressor

  • @surbhikilji351
    @surbhikilji3513 жыл бұрын

    GUJRAT SURAT MAJURAGET ITI RFM 77 B KILJI NAINEESH

  • @fayyazshaikh6832
    @fayyazshaikh68323 жыл бұрын

    RFM 77c majura gate Surat fayad shaikh

  • @bluediamond8436
    @bluediamond84363 жыл бұрын

    Sir,what is the operating pressure of suction line and discharge line thank you!

  • @youtechjb4361

    @youtechjb4361

    3 жыл бұрын

    In this unit pressure of suction line 2.65 bar and discharge pressure is 15.69 bar.

  • @sanjeewaperera5961
    @sanjeewaperera59614 жыл бұрын

    👌 👍 👍 👍

  • @youtechjb4361

    @youtechjb4361

    4 жыл бұрын

    Thank you dear😍

  • @bishnumahata1585
    @bishnumahata15853 ай бұрын

    who.is priec

  • @osomo2372
    @osomo2372 Жыл бұрын

    you have a lot of mistakes since you work. I am a cold fitter and I have studied this job.

  • @abdorakeebnaji1527
    @abdorakeebnaji15273 жыл бұрын

    U talking 2 ur self.👎👎👎👎

Келесі