Advanced Refrigeration - Charging
Тәжірибелік нұсқаулар және стиль
Table of Contents:
00:00 - Advanced Refrigeration
00:20 - Charging Defined
00:55 - Charging Refrigerants - Methods
01:57 - Charging Refrigerants - Methods
03:19 - States of Refrigerant Charging
03:28 - Vapor Charging - Overview
03:47 - Vapor Charging
04:05 - Vapor Charging
04:21 - Vapor Charging
04:34 - Vapor Charging
04:58 - Vapor Charging
05:06 - Vapor Charging - Advantages
05:23 - Vapor Charging - Disadvantages
06:10 - Liquid Charging - Overview
06:38 - Liquid Charging
07:21 - Liquid Charging
08:14 - Liquid Charging
08:19 - Liquid Charging
08:48 - Liquid Charging
09:25 - Liquid Charging - Advantages
09:44 - Liquid Charging - Disadvantages
09:51 - Weighing Refrigerants - Overview
10:10 - Weighing Refrigerants
10:23 - Weighing Refrigerants
10:41 - Weighing Refrigerants
10:48 - Measuring Refrigerants - Overview
11:34 - Measuring Refrigerants
11:46 - Measuring Requirements
12:17 - Steps to Charge
12:40 - Steps to Charge 1
13:06 - Steps to Charge Diagram
13:41 - Steps to Charge 2
13:58 - Steps to Charge Diagram
14:04 - Steps to Charge 3
14:28 - Steps to Charge 4
14:38 - Troubleshooting
15:12 - Troubleshooting
15:31 - Troubleshooting
15:48 - Troubleshooting
Пікірлер: 24
A to-the-point outline. Thank you!
Thank you so much my friend! It's the best explanation I ever had.
Great lesson. Thank you!
I loved your video thanks for your time, when the system undercharge normally you would have high superheat and low subcool, arent subcool and superheat are opposite temp in case of high and low charge system.
Storytime.. so i was charging an old deep freeze ice cream freezer in a customers house.. i guess i should have thrown a flag it being a semi stocked dedicated ice cream freezer but it was late and it just needed a new compressor. So i was charging the system and using digital scales, vapor charging.. but got a phone call from the better half and stepped out for about 2 mins and when i walked back in my damn can was sitting on the ground still charging and the scales were gone... so i got confused at first thinking if there was a dog around but nope.. so i walk over to the family room area and wouldnt you know there they are on the coffee table.. with a brick of what im pretty sure was cocaine.. im talking bigger than a red brick for houses.. and there were 4 more sitting beside it... i didnt mean to but i let out a "holy.." and didnt even see the 3 guys sitting around it counting cash.. the owner of the house looked over and said "i put a thousand dollars in your tool bag, sorry i needed to weigh something. ". I said oh no problem i was just wondering where they walked off to.. freezer is charged and working now though, damage is 400 even. You can mail me the check or pay online..". He said ok, i went and got my stuff, over harged the hell outta the freezer but i was barely holding the shit in my pants... so threw everything in my bag snatched up the tank and skirted for the door and dude came up behind me and said hey come here .. so turned around and dude put another thousand in my titty pocket.. said " i know you and where you sleep, you have a nice family, enjoy your nice and quiet life". I said i understand pal, enjoy your cocaine and ice cream.. dude laughed and i did too walking out the door.. scared the dogshit outta me and went home and grabbed my kid and woman.. moral is , well i dunno any moral, i got 2 grand for 300$ worth of materials and scales.. 1700$ for an hour and a half with a story to go with it that shoulda been in a movie.. hell of a day..
@thechemistamvs5033
Жыл бұрын
Dude what a story that's hilarious. Should have said something like "hey man the ONLY issue I see here is that I need that scale to charge your freezer".
good info
15:07 subcooling will be LOW on a low charge. Think: less refrigerant in system = less refrigerant backing up in the condenser coil. The opposite is true for overcharge.
Ilove you video
Thank
Question which of the pressure switch would I need to bypass the high pressure the low pressure switch??
Yellow Jacket make a Low Pressure charging adaptor, does this change some of what is said here?
went from 10 degree td to 21 after installing the correct piston
7:40 diagram seems wrong, the suction port should be after evaporator not before. that is why you cannot pour in liquid because it will flood compressor and cause it lock up.
I need document , or maintenance manual for ac system
i had no superheat on my ac pumped it down took the line off at the coil and nobody ever installed a piston this ran like this for 9 years
If you want one of does old charging i have got
Does not refrigerant tank has one-way valve that the compressor can not pressurize the tank but it would stop the refrigerant charge
@thechemistamvs5033
Жыл бұрын
Maybe some but not refillable refrigeration bottles.
Can I charge R404a at suction side?
@cmolnar65
3 жыл бұрын
Yes, but VERY slowly , you do not want to put a large amount of liquid refrigerant into the compressor. Also, do not do it unless the compressor is running and the system is not in a vacuum. If system is still in a vacuum charge on the high side as a liquid.
@perfectroad7141
3 жыл бұрын
@@cmolnar65 Thank you so much for the info.
@abbe6305
Жыл бұрын
@@cmolnar65 A pump that has low/high side need to be filled with liquid R404A need the system to be off, so better filling on the high side then low side, becuse the system need to be off. you cannot fill with liquid in the suction (low side) when the system is off. 1,8 Kilo luquis in this case. the problem here is the i have tvo ports, one low and one high bot pipes are pointed so de liquid will go to the compressoer, bot line har pointed så liquid will run to the compressor on both side. the ports har above the compressor. In this case a water/heating pump with copeland scroll.
nkn