Fire-Lite BG-10 Recall - The REAL Reason

Ғылым және технология

Link to BG-10 recall information page referenced in video - buildings.honeywell.com/us/en...
Please note that this video is for informational purposes only, and I am expressly denying any claims that this video was produced in conjunction with or intended to represent Fire-Lite Alarms or Honeywell in any fashion. Additionally, I am expressly stating that this video shall not be utilized when making decisions regarding the replacement, upgrade, or repair of any active life safety system.

Пікірлер: 25

  • @kenbowser9694
    @kenbowser969420 күн бұрын

    Thanks so much for this video. I have a ticket next week to replace 13 bg-10s with the 12LX. I've been racking my brain trying to figure out how a pull could be defective heh. Makes total sense.

  • @North_Jersey_Sirens
    @North_Jersey_Sirens2 жыл бұрын

    Ive encountered this at my school before and caught it on video, when I pulled a BG-10 for a fire drill the alarms didn’t activate, so I had to hold down the pull station until the button came free which took like 10 seconds and then the alarms activated. Im glad someone finally made a video about this issue

  • @kcin556

    @kcin556

    2 жыл бұрын

    Just went to your channel and watched the fire drill video where you show this happening - very interesting to see it in the field!

  • @North_Jersey_Sirens

    @North_Jersey_Sirens

    2 жыл бұрын

    @@kcin556 Yeah its kind of concerning considering that pull station is the one most likely to be pulled due to it being at the main entrance, I hope the seals in most of them get replaced next time the system gets inspected

  • @a.r.aproductions1569
    @a.r.aproductions15692 жыл бұрын

    Whenever I am doing an inspection and I come across these, I usually replace at least 3 per inspection

  • @dabitzz

    @dabitzz

    10 ай бұрын

    wow, that's not good

  • @wolverine3217

    @wolverine3217

    3 ай бұрын

    Who decides if your supposed to replace the whole thing

  • @chadrowland5234
    @chadrowland52342 жыл бұрын

    I grew up with BG-10's all over my school. My elementary school had BG-10's everywhere with Wheelock 7002T's. My high school had BG-10's with System Sensor mass horn/strobes. I like the BG-12's but I really like the way that BG-10's look.

  • @theplanetmc181

    @theplanetmc181

    9 ай бұрын

    Same! I love the way they look, they’re just so cool!

  • @firepro-squad7778
    @firepro-squad77782 жыл бұрын

    Very interesting. A well put together video!

  • @filmer765
    @filmer765 Жыл бұрын

    My dad’s gym once had a bunch of BG-10’s. Now, only one remains as the rest has been replaced with some BG-12’s, a 270-SPO’s, an MS-151, and an RMS-1T.

  • @danielonn2002
    @danielonn20022 жыл бұрын

    In a Fire what do you do if the Fire alarm does not work? Do you try pushing the lever up and try again?

  • @frankspliff7037
    @frankspliff70372 жыл бұрын

    Awesome I just got one for my system

  • @joezegers
    @joezegers Жыл бұрын

    The options were replace the seal or replace the pull station with a BG-12.

  • @TheCarson116
    @TheCarson1162 жыл бұрын

    I'm surprised the recall was issued at least 13 years after production stopped (unless it took that long for the problem to be noticed). Also don't know why the site you linked says "from 1992 through 2010", given I'm pretty sure production of the BG-10 ceased in 2000. Why does the BG-10 even need a seal around the switch, shouldn't the switch itself be already sealed fairly well? Honeywell could have also solved the housing fracture problem by simply discontinuing the hex-screw version. Are there versions with seals that _don't_ disintegrate over time? (even though all rubber deteriorates with time last time I checked)

  • @That_2_guy2T

    @That_2_guy2T

    Жыл бұрын

    The seal protects the switch from weather if its being installed outdoors. But seriously why would the seal be nessesary.

  • @TheCarson116

    @TheCarson116

    Жыл бұрын

    @@That_2_guy2T Exactly: heck shouldn't the BG-10 be decidedly _not_ an outdoor manual station to begin with given it's at least 50% plastic? (which is why most outdoor pull stations are largely metal: metal holds up better to the elements)

  • @user-Calebculwell
    @user-Calebculwell Жыл бұрын

    My bg-10’s have that button but the rubber seal is missing

  • @adamkaps168
    @adamkaps1688 ай бұрын

    The one that we just bought will have a key lock instead of a hex one.

  • @SPCcarlionaEAS
    @SPCcarlionaEAS2 жыл бұрын

    My school fire alarm

  • @alexandersalarms5380
    @alexandersalarms53802 жыл бұрын

    see wood watch wasn't smacking a BG-10 it was NASA smacking a strobe cover

  • @TheCarson116

    @TheCarson116

    2 жыл бұрын

    Yes, but NewAge _did_ throw a block of wood at a BG-10L in one video, demonstrating how easily it can be activated.

  • @alexandersalarms5380

    @alexandersalarms5380

    2 жыл бұрын

    @@TheCarson116 Ok

  • @jcam2026
    @jcam20262 жыл бұрын

    i used to put coins in those coin slot looking things when I found them around my pre school when I was like 5

  • @West_Kootenay_railfan
    @West_Kootenay_railfan2 жыл бұрын

    Old ghosts 🙂