Does your combi boiler pressure keep rising? Sometimes even when switched off.

Тәжірибелік нұсқаулар және стиль

What to look for if this is happening to you.
Saved some money on calling a plumber? Click the SUPER THANKS button. Visit Al`s plumbing shop for parts at www.amazon.co.uk/shop/dereton33,
Thanks Al

Пікірлер: 31

  • @InArcadiaSum
    @InArcadiaSum8 ай бұрын

    I had Worcester Bosch which had the key filler system, gushes out when the key is removed and which leaked afterwards. The plate underneath was full of water stains, and I was told that some people leave the key in (not recommended) to try and stop this problem. It's a silly system, and I had it changed for a Bosch keyless loop with the pull-down blue lever. That was slightly better, although the lever was very stiff, but at least there isn't an opening to the outside in the thing.

  • @dereton33

    @dereton33

    8 ай бұрын

    Yes the key thing is a step backwards a terrible idea.

  • @curiouscuriouscamel

    @curiouscuriouscamel

    8 ай бұрын

    Sorry to tell you the keyless lever system is worse. Ours was passing leading to high pressure after about 6 years and was replaced with the newer key version. The engineer said the keyless ones regularly fail in this way 😢

  • @grimawormtongue2014

    @grimawormtongue2014

    5 ай бұрын

    ​​@@dereton33I have a Worcester greenstar 30I. External filling loop has been disconnected from the return pipe. When CH is off, pressure is at 1 bar. When the heating is on, pressure junks go to 3/3.5 bar and stays there even though the heating is off and the water is cold in the CH system. Is this an expansion vessel issue? If so, what is causing this and how to rectify? Boiler is 10 years old and has never been serviced.

  • @alangordon3283
    @alangordon32838 ай бұрын

    Thanks Der

  • @dereton33

    @dereton33

    8 ай бұрын

    No problem 😊

  • @thomascoyne157
    @thomascoyne1578 ай бұрын

    Thanks al very useful information 👍👍👍👍👍👍🇬🇧

  • @dereton33

    @dereton33

    8 ай бұрын

    No problem 👍

  • @sorbetingle
    @sorbetingle8 ай бұрын

    Al....can i ask an unrelated question please?....im plumbing 3 small rads under my bay window ( cos cant afford a special bay window rad ) id like to ask how is best to plumb 3 rads, should i connect all 3 together top and bottom as if it were one rad with a flow connection to number 1 rad, and return out of number 3 rad?....or plumb each one separately with flow and return for each small rad?.....ty Al

  • @dereton33

    @dereton33

    8 ай бұрын

    If you're happy to have all three at the same temperature, then connect them all together top and bottom. If you want to be able to turn down the temperature on separate rads, then plum then in separate with there own valves. Al.

  • @sorbetingle

    @sorbetingle

    8 ай бұрын

    @@dereton33 thankyou, i think i will treat all 3 rads as one, and have one trv ....ty Al

  • @loriAlessiroberts118
    @loriAlessiroberts1188 ай бұрын

    Can toilet pipe still go into floor or do they have to go through the wall? My old toilet pipe goes into the floor. Thank you😊

  • @dereton33

    @dereton33

    8 ай бұрын

    Still into the floor is fine

  • @agnieszkakaszuba1498
    @agnieszkakaszuba14983 ай бұрын

    My boiler pressure keep raising when I using heating on , when I dont use all day it stay thw same points 🤔what could be reason for this. So if the pressure will be to high ,the excess waters will go outside the building ?

  • @dereton33

    @dereton33

    3 ай бұрын

    It will increase as you you the heating as the water expands when it gets hot, it is quite normal. The pressure has to reach over 3 bar to to blow the PRV and flow outside.

  • @smburr1
    @smburr18 ай бұрын

    It’s not uncommon for the plate heat exchanger to become pin holed on these boilers which will cause the pressure to rise

  • @dereton33

    @dereton33

    8 ай бұрын

    Thanks

  • @grimawormtongue2014

    @grimawormtongue2014

    5 ай бұрын

    How do you check the plate heat exchanger is causing the issue? Is that the same as p2p? Update. The heat exchanger plate was pin holed in my case. To test the plate, turn the cold supply going into the boiler, I checked the pressure after an hour and the pressure did not rise. Changed the plate, pressure isn't rising anymore.

  • @paulw4904
    @paulw49048 ай бұрын

    Why on earth did you fit a Worcester Bosch? Horrible boilers!…. Just ripped one out this morning & the best place for it was in the front lawn!

  • @dereton33

    @dereton33

    8 ай бұрын

    It's been great so far ☺️. Should I dig a grave ready for it. Ha ha.

  • @guijggujji6627
    @guijggujji66278 ай бұрын

    I am From Bangladesh 🙏🙏I watch all your videos. I have a problem help me🙏

  • @dereton33

    @dereton33

    8 ай бұрын

    What's up?

  • @guijggujji6627

    @guijggujji6627

    8 ай бұрын

    @@dereton33My mother needs a lot of money for kidney problem treatment if anyone can help

  • @user-bh1xu3tf2m

    @user-bh1xu3tf2m

    8 ай бұрын

    Hi

  • @guijggujji6627

    @guijggujji6627

    8 ай бұрын

    ​@@dereton33My mother needs a lot of money for kidney problem treatment if anyone can help

  • @guijggujji6627

    @guijggujji6627

    8 ай бұрын

    ​@@dereton33My mother needs a lot of money for kidney problem treatment if anyone can help

  • @Ade-mv1ji
    @Ade-mv1ji4 ай бұрын

    Thanks @dereton33 you just gain a subscriber :)

  • @dereton33

    @dereton33

    4 ай бұрын

    Thank you.