Daikin inverter | air conditioner Thermistor Failure Symptom
Brand : Daikin
model : MKS80QVM
ERROR : No error
Symptom: Running after 45minutes,Fcu auto off and auto on back,outdoor LED 1 & 2 light up.
Cause : Thermistor failure Symptom,thermistor short circuit.
#bonmj #daikin #inverter
Пікірлер: 108
Sir .Bon Mj Your technical Video's very useful for technician. Great job Thank you so much 🙏🇶🇦
@BonMj
Ай бұрын
It's my pleasure
I never find this problem before😂😂😂, first time some one share this information in KZread. You are the best⭐⭐⭐⭐⭐
@BonMj
2 жыл бұрын
Thanks
Hello. A very good tip, I'm sure many technicians didn't even know about it
@BonMj
2 жыл бұрын
Thanks
Bon your videos are excellent! Thank you
@BonMj
2 жыл бұрын
Thanks
Thanks Sir Bon Mj ❤️ A big help to us technician, A far areas and urban areas..🙏🙏🙏
@BonMj
Жыл бұрын
Welcome
That’s a great tip thank another fantastic video
@BonMj
2 жыл бұрын
Thanks bro🙏
Hey, thanks for everything. explain his picture and I'm good.
👏 bravo bro 👍
thank you, please continue to upload the video.
@BonMj
2 жыл бұрын
Thanks bro
Thank you sir
This is very good helpful information thanx sir.
@BonMj
2 жыл бұрын
Thanks
Great video thank you.
@BonMj
2 жыл бұрын
Thanks
Trimakasih bos
@BonMj
Жыл бұрын
You Dari mana? Terima kasih banyak nonton video saya
❤
Hello sir, nice troubleshooting, thanks
@BonMj
2 жыл бұрын
Welcome
Very useful information
@BonMj
Жыл бұрын
Thanks
Thank Sir Bon
@BonMj
Жыл бұрын
Welcome
Very good information
@BonMj
2 жыл бұрын
Thanks
Thanks Boss.
@BonMj
2 жыл бұрын
Thanks
Thank you sir 🙏
@BonMj
2 жыл бұрын
Thanks🙏
Thank you so much
@BonMj
2 жыл бұрын
Thanks
Thank you boos 👍
@BonMj
2 жыл бұрын
Thanks
Nice one bro
@BonMj
2 жыл бұрын
Thanks
Thank you bro
@BonMj
2 жыл бұрын
Thanks bro
Thank sir
@BonMj
Жыл бұрын
Welcome
Thank you....
@BonMj
2 жыл бұрын
Thanks
Tq Boss 🙏
@BonMj
2 жыл бұрын
Thanks🙏
Hi Bon, could you please provide a source for many of the common manufacturers thermistor resistance/temperature values? I cannot find any for the LG brand.
👍 👍 👍
hi sir im p paul kolkata i lick you video
Normally daikin compressor discharge thermistor range 13 to 15 kilohms right ?
That would be hard to find on the system unless its in cooling mode developing condensation at the time you are checking. Did the error code send you in the direction to check the thermistors? Last question did you full change the harness or just dry and seal the bad thermistor?
@BonMj
2 жыл бұрын
Just happen after running 45minutes. Only outdoor LED 1&2 on when stop running,indoor auto off and will auto on back after for awhile. We replace the new harness.
@Achabab
2 жыл бұрын
@@BonMj thank you share your knowledge 🙏🙏🙏god bless you
@BonMj
2 жыл бұрын
@@Achabab welcome
Bonjour , comment je pourrais avoir la version française
sir inverter daikin 1.5hp ,indoor fan motor stay in low speed what maybe the reason o the problem ? even we changes to high speed in the remote fan speed still low,thanks for the reply
@BonMj
2 ай бұрын
Any coil choke
Daikin Indoor fan motor no running a6 alarm coming I replace indoor motor and indoor PCB board also but still have a6 alarm ? What is problem
@BonMj
Ай бұрын
Check thermistor
Same can happen Mitsubishi system
Hai sir ,vrv 3 Daikin system one outdoor 3 indoor ,all running good but , standard compressor Haven't run even one FCU haven't achieve room required temperature.please advise
@BonMj
Жыл бұрын
May be already by pass. Check mode2
@peramaraj2763
9 ай бұрын
@@BonMjalready bypass how to find ? Bro
Hi Sir! What's the reason you put the thermistor in the water and than you checked the countinity again?
@BonMj
Жыл бұрын
Put in the water just show the thermistor is short circuit when water go in to the parts. When the thermistor locate at suction pipe,the water will go into the parts after gas pipe condensation.
@zse0118
Жыл бұрын
@@BonMj Thank you so much for your answer.
If short thermistor what could happen PCB
@BonMj
Жыл бұрын
For this case intermittent blinking, pcb ok.
这种情况好难被发现!感谢老师!contiuniry中文是什么?
@BonMj
2 жыл бұрын
谢谢你。去了两次才发现
@BonMj
2 жыл бұрын
Continuity 是联系的,比如wire用meter 量continuity 。
Sir. My aircon.. cut in compressor n fan for 30min for 3 room. Is it thermistor of outdoor? I saw your ismike series, u change the indoor thermistor... May I know if is the same logic? Mine are toshiba
@BonMj
Жыл бұрын
What is your setting temperature
@errantpmd3765
Жыл бұрын
@@BonMj sir.. even in the lowest also the same.
@errantpmd3765
Жыл бұрын
@@BonMj correction sir. Is 30sec..not min.
@BonMj
Жыл бұрын
@@errantpmd3765 may be outdoor pcb problem
@errantpmd3765
Жыл бұрын
@@BonMj sad.. :( Thought is some thermistor...
Hi sir vrv 3 Daikin AC e2 error and E3 error how to make rectify
@BonMj
2 жыл бұрын
E2 may earth leakage E3 high pressure sensor/high pressure switch
How to apply your company sir
Hi sir my wathsup no not going for comment
Sir daikin vrv3 modal rxyq12pry6 error code p4 Cheng master PCB
i need job i am air conditioning and refrigeration mechanic
Hi sir I have problem daikin package unit error E 32 how to rectify this problem sir
@BonMj
2 жыл бұрын
Check Compressor 1
@nagarajvenkat8476
2 жыл бұрын
Thanks sir
Hi sir I have problem is Diakin air conditioning vrv system celling saspanded units have the error UF this error what is the problem sir thanks
@BonMj
2 жыл бұрын
You change indoor pcb?
@govindarasugovindarasu7440
2 жыл бұрын
@@BonMj no sir
@BonMj
2 жыл бұрын
@@govindarasugovindarasu7440 check indoor all fcu voltage or pcb faulty
Hello sir I am Aziz. I have a Daikin 1.5 ton inverter split AC. My AC is showing C3 error code. Can you please tell me what C3 error code is and how to solve it . Model no FTKZ50U
@BonMj
Жыл бұрын
Try check i door thermistor. Actually this error is water level sensor problem
@azizullahkhanpathan2693
Жыл бұрын
Thank you for your reply sir 👍
@azizullahkhanpathan2693
Жыл бұрын
I will check
@azizullahkhanpathan2693
Жыл бұрын
@@BonMj Hello sir my AC is Daikin inverter split AC it is showing C3 error code will you please confirm what is the issue in it C3 means?????
@azizullahkhanpathan2693
Жыл бұрын
In the split AC water level sensor will be there ?????