No video

COMMERCIAL 3 BASIN RESTAURANT SINK REPLUMB

Пікірлер: 54

  • @GonzalesMansion
    @GonzalesMansion Жыл бұрын

    The clean outs were a great idea. Looks awesome

  • @recoverygaming4900
    @recoverygaming49003 жыл бұрын

    This is like an everyday job very kool video to show people new to commercial plumbing

  • @karlzaker6710
    @karlzaker671011 ай бұрын

    Hahaha. TIM; by code, you can’t put drain INTO floor drain. Air gap must be maintained to prevent contamination from flooding drain

  • @seanmalone7920

    @seanmalone7920

    Ай бұрын

    100% right this isn't done correctly

  • @shovelhead8
    @shovelhead83 жыл бұрын

    Nice job, Tim. Nice bonus as well. Thank you for letting us watch. Stay safe and stay cool.

  • @yepdodamath
    @yepdodamath3 жыл бұрын

    1:35 I was starting to feel for that guy's eyes. Always wear eye gear!

  • @TheHuntermarks
    @TheHuntermarks Жыл бұрын

    You are one precise PVC measuring fool to line up all 3 and get em all to go in like that! 😂😂

  • @jpvoodoo5522

    @jpvoodoo5522

    10 ай бұрын

    Yes, how do you figure out the length of each pipe and fixture? Can you recommend a tutorial on that part?

  • @SunnyKumar-hj4iy
    @SunnyKumar-hj4iy2 жыл бұрын

    Thanks TIM...awesome vudeo.Great work.So helpful.God bless you man

  • @cylentsmoker
    @cylentsmoker11 ай бұрын

    Dude awesome. Just got into the same kind of work recently and i enjoy the shit out of it. Your videos are helpful man thank you

  • @tomdale1313
    @tomdale13133 жыл бұрын

    three compartment sink...good job

  • @plumbbuild6517
    @plumbbuild65173 жыл бұрын

    I hear you dude great job and I hope you enjoyed that Jersey Mike's sub and thanks for your videos have a good weekend Tim

  • @elnicadrums
    @elnicadrums3 жыл бұрын

    Nice 👍👍👍👋💪 good job you guys kicked butt 👍👍

  • @user-fs6wb5kf1l
    @user-fs6wb5kf1l Жыл бұрын

    i would be worried about the gaskets that are pushed out. should have tightened from the top with special tool

  • @curt8120
    @curt81202 жыл бұрын

    In any state I Work the code changed you cannot connect the drains together if you have one of the sinks being a clean sink, its a cross connection that is illegal in any restaurant. and the air gap is 2-1/2 times the diameter of the discharge pipe.

  • @angelloco72
    @angelloco726 ай бұрын

    Nice work 👏

  • @matthewpowell4845
    @matthewpowell48453 жыл бұрын

    Tim they make a t and a insert / key for those drains. But you seem old school and use channelocks lol

  • @elektroman3187
    @elektroman31872 ай бұрын

    5:03 Great job! Only question is how did the dishwasher pull out the grills and filters out of the drain after you placed it so far down into the pit? Did you have to go back and cut it out to let the drains out or are they split grills? Those guys have to pull out the grills and drain filters to clean them at least every few days. Did they just figure they should clean it while it's hanging off the drain pipes? Regardless of my questioning, your work is at least 10 times better than the set up we have at my jobsite...

  • @seanmalone7920
    @seanmalone7920Ай бұрын

    It's supposed to be indirect waste which mean ur discharge line should have an air gap at the top plate not Recessed inside the Floor Drain

  • @michelejann5732
    @michelejann5732 Жыл бұрын

    For your safety safety glasses a must ❤❤

  • @wittelarry1
    @wittelarry1 Жыл бұрын

    It's always fun cutting those out

  • @theartofplumbing
    @theartofplumbing3 жыл бұрын

    Nice job Tim

  • @seannappi
    @seannappi3 жыл бұрын

    Hey, out here in Cali 😀 we have to air gap indirect drains, do you not have same rules? Thanks for the great videos keep up the hard work!

  • @graysonsheridan1593

    @graysonsheridan1593

    2 жыл бұрын

    That center downpipe drops right into an open Drain. It is just covered to keep stuff from getting in there.

  • @dbenterprise3oh2

    @dbenterprise3oh2

    Жыл бұрын

    Yes but it should still be air gapped. Just did a Starbucks in Delaware. Air gap is code.

  • @paigewagner4857

    @paigewagner4857

    11 ай бұрын

    100% Indirect waste always has to have a 1" air gap no matter where your at

  • @gabeking2996

    @gabeking2996

    6 ай бұрын

    You are right it has to have a 2" air gap it's international plumbing cod so it's like that everywhere kinda seems more like a handyman and not a plumber !

  • @madcowusa4277
    @madcowusa4277 Жыл бұрын

    Just a novice interested in plumbing, I thought code doesn't allow sanitary tees on their back like the two outermost sinks? I'm guessing the sinks themselves act as a vent and the pipe into the drain grate is air gapped. Anyway, saw a triple sink setup today with one additional sink draining in from each side of it (5 sinks total) - all done with sanitees like this so I guess this the norm. And all 5 sinks were plumbed in 1.5" ABS which can't possibly be big enough.

  • @michelejann5732

    @michelejann5732

    Жыл бұрын

    So the 1.5" ABS isn't enough what would be

  • @bartman22x1
    @bartman22x1 Жыл бұрын

    We need to do a 3 basin corner sink

  • @jpardo100855
    @jpardo1008553 жыл бұрын

    I'm curious as to whether you used the correct cement for the transition from pvc to abs?

  • @rojohe

    @rojohe

    9 ай бұрын

    That double sanitary tee fitting is not ABS, it's PVC Schedule 80 (which is also available in PVC Schedule 40.)

  • @steventaing1544
    @steventaing15447 ай бұрын

    That is not code it has to drain individually and have to be 1 inch above the in ground drain to avoid cross contamination.

  • @scopeside
    @scopeside7 ай бұрын

    Hey boss can you help me with something. Is there any codes for these or where you need 3 individual drains 1 per bay and are you allowed to put sani’s on their back ?

  • @SandwichesRule
    @SandwichesRule Жыл бұрын

    Tim, I want purchase the new drains for my shop, I see there are 3”& 3.5”, how would I know what to purchase? Is there a measurement that I can take on my existing think? Thank you.

  • @lulubliz6405
    @lulubliz64056 күн бұрын

    No grease trap??

  • @humbleone4227
    @humbleone42274 ай бұрын

    Nice job Whats the average on a job like that thank you

  • @antonioantonio7540
    @antonioantonio7540 Жыл бұрын

    Did you use a smaller pvc to fit in the drain pipe?

  • @thomasrawlings2715
    @thomasrawlings2715 Жыл бұрын

    If the threads were no good in top of drain, why was it still holding. Forget your key

  • @gyver471
    @gyver471 Жыл бұрын

    Can I reduce it down to 1 1/2 instead of 2”?

  • @grubbygringo
    @grubbygringo3 жыл бұрын

    No air gap? That's a big no no.

  • @thomasrawlings2715

    @thomasrawlings2715

    Жыл бұрын

    Air gap is in floor drain under grate

  • @Erickhardaway
    @Erickhardaway2 жыл бұрын

    What inch pipe did you use on the drain?

  • @PLUMBINGWITHTIM

    @PLUMBINGWITHTIM

    2 жыл бұрын

    2”

  • @kingokafor6215
    @kingokafor6215 Жыл бұрын

    I believe in ohio that requires a 4inch air gap

  • @vishyandypurandat6208
    @vishyandypurandat62083 жыл бұрын

    Rookie here asking a question. Does it need a vent or is it so close to an entry or drain it doesn't?

  • @recoverygaming4900

    @recoverygaming4900

    3 жыл бұрын

    It has an air gap so no vent needed

  • @__comic
    @__comic3 жыл бұрын

    How much did you charge for that job in about to do the same

  • @PLUMBINGWITHTIM

    @PLUMBINGWITHTIM

    3 жыл бұрын

    I think it was between $450 and $500

  • @evanschrisjr
    @evanschrisjr7 ай бұрын

    This does not pass code

  • @fredpastuh7518
    @fredpastuh75183 жыл бұрын

    Tee ABS? Why?

  • @PLUMBINGWITHTIM

    @PLUMBINGWITHTIM

    3 жыл бұрын

    Only one I could find in our warehouse 😂

  • @fredpastuh7518

    @fredpastuh7518

    3 жыл бұрын

    @@PLUMBINGWITHTIM need use trans glue?)

  • @lulubliz6405
    @lulubliz64056 күн бұрын

    No grease trap??