Boiler Leaky Air Vent Repair

Ойын-сауық

I am on a service call and the air vent on a hot water boiler leaks. Therefore I have to replace the hydronic boiler air vent. I drop boiler pressure to zero. Remove old vent and install new vent.

Пікірлер: 37

  • @whatnow5313
    @whatnow53137 ай бұрын

    Perfect channel name for this guy.

  • @Ted_E_Bear
    @Ted_E_Bear2 жыл бұрын

    Another awesome job Hacker !

  • @felixlaboy1453
    @felixlaboy14532 жыл бұрын

    Great video buddy.

  • @whatnow5313

    @whatnow5313

    7 ай бұрын

    🤮

  • @rufiorufioo
    @rufiorufioo3 ай бұрын

    So I have two air vents and looking to replace them cause leaking. one if 150 psi 240 and the other is 35psi type 67. Is this normal?

  • @Momof5DailyLife
    @Momof5DailyLife5 ай бұрын

    Mines leaking and I just replaced it a yr ago exactly!

  • @johnny0253
    @johnny0253 Жыл бұрын

    how old is that hydrotherm boiler??? they still make them???

  • @jcaleca60
    @jcaleca602 ай бұрын

    Once you open up the system you get air into the lines don't you have to bleed the whole system oh you think that air valve will do it?😊

  • @manonfire3642
    @manonfire36422 жыл бұрын

    Volume?

  • @austinmurray4012
    @austinmurray40122 жыл бұрын

    Do you tighten the cap on that valve, leave it loose, or leave it off ?

  • @thehvachacker

    @thehvachacker

    2 жыл бұрын

    Leave it loose. If it’s closed air vent won’t let the air out

  • @jinrungao
    @jinrungao2 жыл бұрын

    Hi, I wonder why when the old vent was taken out, there was no water coming out. Don't you have to drain it below that level in order for water to not come out? Or somehow the water stays in after you shut the supply ball valves and relieved pressure to zero? Thanks

  • @etlawson6939

    @etlawson6939

    2 жыл бұрын

    His finger was wet at the very beginning and when you remove the pressure from the boiler the water is bellow the vent.

  • @thehvachacker

    @thehvachacker

    2 жыл бұрын

    A coworker replaced the expansion tank earlier that day. He should of changed the vent also. There was blue crust on it. Indication it leaks sometimes. Yet once the pressure was dropped the foot in the air vent drops. Allowing crude to prevent the float from sealing again. I replace a vent every time I open a boiler. They usually leak if I don’t replace

  • @throttlebottle5906

    @throttlebottle5906

    2 жыл бұрын

    @@thehvachacker yeah, pretty much if pressure needs removed, replace all vents, relief valves and expansion tanks (or check charge). if not there will be guaranteed callbacks. ** boiler drain valves while at it, leaks galore :)

  • @jimmaples4373
    @jimmaples4373 Жыл бұрын

    This is a great video. Should the vent cap be tight or a little loose? I also have an issue with my Weil-McClain cga that no service shop can resolve: When my boiler finishes heating the water the temperature will coninue to climb (up to 220 degrees) if I don't have a circulating pump running. Have you seen this? Thanks

  • @MrK-vf1dp

    @MrK-vf1dp

    10 ай бұрын

    I have the same question

  • @chrisharvie-smith486

    @chrisharvie-smith486

    6 ай бұрын

    Sounds like the water side of the boiler is covered with scale (calcium carbonate &/or magnesium carbonate) this slows the heat transfer so when the pump stops the hotter metal keeps transfering heat to the water. As pump is off it keeps getting hotter. Citric acid based descaler can be added & left to circlate for a few days to clean the boiler & baseboard/radiator heaters. Colour changing descaler lets you know if you need to add more or that it's finished. It doesn't emit gas so won't need venting. When you are done flush the system a few times & add inhibitor with the last refil. It should make the whole system more efficient as more of the heat can reach the pumped water. 🙂

  • @jimmaples4373

    @jimmaples4373

    6 ай бұрын

    Thank you sir. I’ll try it and let you know.

  • @jcaleca60

    @jcaleca60

    2 ай бұрын

    I have an old system from 1950 Venturi T's one zone anytime I do anything open up the boiler I have to bleed all the old fashioned radiators they are the ones that go under the window just copper with fins on it from the 1950s😊

  • @ythm18
    @ythm182 жыл бұрын

    Would this leaky vent cause the boiler pressure to drop over time if it was not fixed?

  • @thehvachacker

    @thehvachacker

    2 жыл бұрын

    It could if the PRV failed or supply was shut.

  • @stephwaylonwells3218
    @stephwaylonwells32182 жыл бұрын

    👍

  • @williamserver4332
    @williamserver43322 жыл бұрын

    What would happen if you put a plug in that tee and eliminated the vent? Great video

  • @thehvachacker

    @thehvachacker

    2 жыл бұрын

    Most lazy techs will crank down that cap on top. Yet air in the system makes gurgling sounds when the heat is on. If enough air builds the boiler gets air locked. Water won’t move through the air. The pump doesn’t create enough force to push or pull an air pocket. Make up water can introduce air. Now on a system with glycol, make up water is valves off no PRV. Air vents also closed. Have to keep proper mixture glycol and water.

  • @williamserver4332

    @williamserver4332

    2 жыл бұрын

    @@thehvachacker Thanks for the explanation. If you eliminate the PRV valve in a closed glycol system what protects the system from a disaster like if for some reason the burner Didnt shutoff?

  • @Wolfhound.
    @Wolfhound.2 жыл бұрын

    about 6 years is a good life ? guess i have high expectations

  • @chrislauterbach8856
    @chrislauterbach88562 жыл бұрын

    Why didn't you use Teflon tape?

  • @thehvachacker

    @thehvachacker

    2 жыл бұрын

    Didn’t want to. Teflon, pipe dope, it don’t matter these threads don’t leak ever. It’s the float inside that gets gunked up and won’t make a seal.

  • @chrislauterbach8856

    @chrislauterbach8856

    2 жыл бұрын

    @@thehvachacker I've seen other videos so That's why I asked

  • @thehvachacker

    @thehvachacker

    2 жыл бұрын

    @@chrislauterbach8856Teflon alone can seal a water pipe. Dope alone also. Doing both is just better protection. I usually only dope the vent.

  • @chrislauterbach8856

    @chrislauterbach8856

    2 жыл бұрын

    @@thehvachacker thanks

  • @realestateservicessaleshea99
    @realestateservicessaleshea992 жыл бұрын

    Neat job ! 🥃🥃🍺🍺🍺🍇🏌🏻‍♀️ Stay safe. Retired (werk'n)keyboard super tech. Wear your safety glasses!

  • @whatnow5313

    @whatnow5313

    7 ай бұрын

    Neat? Maybe you need new glasses?

  • @realestateservicessaleshea99

    @realestateservicessaleshea99

    7 ай бұрын

    ​@@whatnow5313would you have him rebuild the whole set!😂😂😂

  • @stevetung4728
    @stevetung47286 ай бұрын

    You opened the drain valve, and water came out. What does that mean? The air equal to the volume of the displaced water was now in the piping system. You took off the old air vent valve, and no water came out because now that part of the piping had the air. At the end you didn't purge the air out of the piping. So this video is like many others a fake. Not real plumbing job.

  • @WallaceLee-rm4vb

    @WallaceLee-rm4vb

    5 ай бұрын

    The air leaves through the bottle vent he just installed. That's the same place it came in through when he drained.