15kw MEP-804A Military Generator major repair

Tune in to my journey into repairing this Fermont 15kw 804-a diesel generator with an isuzu c-240 engine
This video was powered by 70% diesel generator and 30% solar :)
Special shoutout to Jim at Joilet electric motors for being able to rewind the exciter coils!!!
Link to the manual. www.liberatedmanuals.com/TM-9...
Link to voltage regulator. www.amazon.com/dp/B08L11GT66?...

Пікірлер: 45

  • @johnweatherford5760
    @johnweatherford57602 жыл бұрын

    Thank you for the video I really enjoy the details.

  • @ltr6541
    @ltr65412 жыл бұрын

    Oh my God your projects turn out EXACTLY like mine do :-P there is nothing wrong with this its awesome...and I end up becoming an expert on what I'm fixing haha awesome generator :-) that will be with you the rest of your life now :-) I always smile when things go south with power and your neighbors show up with cords for their houses:-)

  • @dynomatic5099

    @dynomatic5099

    2 жыл бұрын

    Yeah hahaha man this thing has been one heck of an adventure. I still have some minor parts that this thing needs that I can’t find yet like a fuel filler neck

  • @rickyvasquez3157
    @rickyvasquez31572 жыл бұрын

    VERY NICE that was intense.

  • @tujuprojects
    @tujuprojects5 ай бұрын

    I think you’re correct about those vibration plates, I have seen them in boat axels.

  • @mafosa8519
    @mafosa85192 жыл бұрын

    "thats a bad ass gen.!" great share! larry

  • @T2D.SteveArcs
    @T2D.SteveArcs10 ай бұрын

    That's amazing, I want one 😂

  • @ryanschulte1437
    @ryanschulte1437 Жыл бұрын

    More Juice!

  • @T2D.SteveArcs
    @T2D.SteveArcs10 ай бұрын

    😎👍

  • @bubbajoe745
    @bubbajoe745 Жыл бұрын

    So that thing that was hanging was the stator for the alternator?

  • @javidgunraj1500
    @javidgunraj15005 ай бұрын

    Does the low voltage light come back on? Mine comes on startup even with nothing connect

  • @marshallsayre58
    @marshallsayre582 жыл бұрын

    So you had the stator&rotor rebuilt? In Chicago?

  • @tujuprojects
    @tujuprojects5 ай бұрын

    Sorry to say, but once your contactor pulls between two generators, they are not going to fall out of sync :) or an axel will snap.

  • @tujuprojects
    @tujuprojects5 ай бұрын

    How good frequency stabilization that genset has? My Quattro is very picky and my old genset has a mechanical governor which is not stable enough.

  • @basspig
    @basspigАй бұрын

    It appears that the fuel gauge on this generator is not working as it's all the way down off the scale. Is that a simple fix?

  • @lenielupian2699
    @lenielupian26992 жыл бұрын

    Hi, could you tell me What place did you get the rewind done in Chicago?? I have a gen with a similar problem. And what did it cost for the repair.Thank you...

  • @dynomatic5099

    @dynomatic5099

    2 жыл бұрын

    A place called Joliet electric motors. I would call them and get a quote. Talk to Jim.

  • @marshallsayre58
    @marshallsayre582 жыл бұрын

    Hi, whts the dial L-1,L-2,L-3? I saw the same dial on anthr genset. These are pretty cool. Ill have to chk ur othr videos too

  • @Ringele5574

    @Ringele5574

    2 жыл бұрын

    Lug 1, Lug 2, Lug 3. For going from single phase to 3 phase.

  • @dynomatic5099

    @dynomatic5099

    Жыл бұрын

    @@Ringele5574 the dial is for reading the voltage of each phase as well as current between phases i definitely need an update video i have been very busy with this new job i got.

  • @hunterhines-qg2bn
    @hunterhines-qg2bn Жыл бұрын

    Can you show maintenance fluid to keep her top notch

  • @dynomatic5099

    @dynomatic5099

    Жыл бұрын

    Yes I am working on another generator one soon within a month or two

  • @rolyisern4550
    @rolyisern45502 жыл бұрын

    I have the exact same problem and I order the voltage regulator you said to get. Any way you can point me in the direction when switching the original wires to the new regulator

  • @dynomatic5099

    @dynomatic5099

    2 жыл бұрын

    Yes I will be making another video on it soon

  • @Colton-dl1ig

    @Colton-dl1ig

    Жыл бұрын

    Have you made this video yet? I'm also interested in how you transferred the voltage regulator over. Thanks.

  • @tobyzahn9943
    @tobyzahn99432 жыл бұрын

    I bought mine ina ebay auction, brought it home changed oil and filters, new suction line to feul tank, belt and batteries and walla. Tied into meterbase with a manual transfer switch. I ran it every sunday for a year powered up the house no issues. I am awaiting now the 2020 hurricane thinking how I will be her hero and envy of my neighbors...... 0430 AM... yes dear...the power is flickering storm is here...please go crank our generator. And I returned after an hour or so a ZERO. I cannot find infobon the F1 and F2 wires from the genhead itself. I think F2 ends up on terminal 1 of the voltage regulator? And am tracking back thru the fault relays to determine F1's destination? After a year of not completing my project I bought a engine controller and am in the process of dedicating my generator in a WYE High 240 configuration. I did replace the 6 rectifier diodes, just trying to determine the needs of F1 F2 ? The 10 lead lima mac info says self regulating and self exciting. What am I missing?

  • @dynomatic5099

    @dynomatic5099

    2 жыл бұрын

    It is not self exciting. That is the purpose of the voltage regulator. What lights are on on the fault panel?

  • @tobyzahn9943

    @tobyzahn9943

    2 жыл бұрын

    @@dynomatic5099 thankyou for a reply. Well i got frustrated after the storm, 3 weeks w/o commercial power and no help and said ok 1800 rpm 1st purchased on ebay 100 bucks with low oil pressure/ overheat/over rev failsafes. No issue with the engine now. Next up no outputs. Lets just say I am only using the 10 leads WYE 3 PHASE, the contactor and a toggle switch. I am pretty sure i isolated and ohmed the 10 correctly, no shorts. I did find 2 bad diodes in the excite rectifier, replaced all 6. What options do i have for F1 / F2 ? I hope excitation and regulation are my final riddles... And I realize now all of the capabilites and options I lost, but wont ever ask anything more than crank, run and 120/240. And any T/S in the future should be just the basics. I really appreciate your time, thank you.

  • @tobyzahn9943

    @tobyzahn9943

    2 жыл бұрын

    @@dynomatic5099 I am looking into an AVR now, and I also am looking for another diode kit that includes 3 forward and 3 reverse diodes or an assembly.

  • @dynomatic5099

    @dynomatic5099

    2 жыл бұрын

    I think it’s better if your able to have a voltage regulator because you can accommodate for voltage drop when loads are applied. A normal avr won’t necessarily accommodate for that and I definitely need it when I use my transformers so i’m able to use all 3 phases instead of one or two of the legs.

  • @phemmymarruss
    @phemmymarruss2 жыл бұрын

    Hey, could you repair if I buy a used one?

  • @dynomatic5099

    @dynomatic5099

    2 жыл бұрын

    Depending what’s wrong with it

  • @vespoli69
    @vespoli692 жыл бұрын

    Why the transformers? Why doesn't the generator just output 208/3?

  • @dynomatic5099

    @dynomatic5099

    2 жыл бұрын

    It does but I like the higher voltages so it’s less of a voltage drop by the time it gets in the sub panel and I can configure the end voltage of 240 instead of just 208 for the house. I will be making a video of the complete system soon!

  • @dennisgray7509
    @dennisgray75098 күн бұрын

    Not good on the starter to hold it that long

  • @MrFungus2888
    @MrFungus2888 Жыл бұрын

    i have a 804a was working fine , then one day they only way it will make power is if you hold the start switch down .. what happened/

  • @dynomatic5099

    @dynomatic5099

    Жыл бұрын

    Do you mean holding the main line contactor, closed or holding down the power start switch? Also, have you tried battle short yet??

  • @MrFungus2888

    @MrFungus2888

    Жыл бұрын

    @@dynomatic5099 holding down the engine start switch it makes power. soon as you let of no power, as i said it was working. haven't tried battle short , will today

  • @MrFungus2888

    @MrFungus2888

    Жыл бұрын

    battle switch made no difference, the under voltage light is on

  • @dynomatic5099

    @dynomatic5099

    Жыл бұрын

    If the undervoltage light is on, that could mean that your voltage regulator is bad, the only way to check that is to measure the voltage on your exciter field windings.

  • @MrFungus2888

    @MrFungus2888

    Жыл бұрын

    @@dynomatic5099 do you have a video on doing that ? i'm not an electrician

  • @juancervantes4128
    @juancervantes41287 ай бұрын

    Mine runs fine but is not generating any power.

  • @dynomatic5099

    @dynomatic5099

    7 ай бұрын

    The only things it could be if it’s not generating any power is your voltage regulator has failed or maybe the same problem as mine were the exciter coils are gone or your main line contactors not pulling in Tri flipping battle short on and then pressing the on button to see if the mainline contactor pulls in and you get power out