😮 12x EG4 Chargerverter 5000's - 48v 1200A Battery Charging System!

Ғылым және технология

EG4 Chargeverter: www.currentconnected.com/prod...
Victron Lynx Distributor: www.currentconnected.com/prod...
SOK SK48v100 Rack Battery: www.currentconnected.com/prod...

Пікірлер: 236

  • @HighTechLab
    @HighTechLab10 ай бұрын

    To answer questions in advance, no, they are not growing crops with all the power. On the property, there are 3 RV's, one for my mom, one for my dad, and one for my step-dad. RV's are not very energy efficient...so in summer when it's 110F outside, they use a LOT of power to air condition them. The electrical room is also air conditioned and there is a hot tub that used to have the excess diverted to it, but sometimes they don't like waiting until there (isn't) excess. They only have about 12kW of solar, mounted flat, so it doesn't get anywhere near peak production.

  • @guytech7310

    @guytech7310

    10 ай бұрын

    WOW! Quite the project! My only recommendation would be to have kept the Plugs to make it easier if you need to replace one of the chargers in the future. Sooner or later one them will break :( But I can also see why you probably didn't want to go through the hassle & cost of wiring all the outlets.

  • @rv10flyer84

    @rv10flyer84

    10 ай бұрын

    Interesting.

  • @electromechanicalstuff2602

    @electromechanicalstuff2602

    10 ай бұрын

    So about 187 kwh of batteries. Dang I only have 70 and thought I was doing good. I too only have 12kw of panels. I too need more especially in Michigan

  • @nebulight

    @nebulight

    10 ай бұрын

    You didn’t mention anything about a lab in those RVs, Heisenberg.

  • @number40Fan

    @number40Fan

    10 ай бұрын

    If you hadn't pinned this, I wouldn't have cared why you're doing this, but now I have to ask. Why is everyone on the same property, yet living in different RV's?

  • @Jennifer-007
    @Jennifer-00710 ай бұрын

    A million dollars worth of genset, chargeverters and batteries yet we can't afford a new 9v for the smoke alarm... makes perfect sense.

  • @BillMeier-jh6gs

    @BillMeier-jh6gs

    Ай бұрын

    One of my retrievers really dislikes alarm beeps, they have to be addressed right away or she is in our faces until we do. I had to kennel her in order to watch this video.

  • @randacnam7321
    @randacnam732110 ай бұрын

    Sounds like a good PV mounting structure would be a solar canopy to park the RVs under so sun isn't hitting them directly which would cut the heat gain.

  • @davefroman4700

    @davefroman4700

    4 ай бұрын

    Gov Subsidy WILL cover 30% of the cost of such a structure if you are covering it with solar now.

  • @danielelise7348
    @danielelise73485 ай бұрын

    All that available power & yet no power for the smoke alarm,an alarm you REALLY want operational ⚡⚡🔥🔥

  • @offgridliving4128
    @offgridliving412810 ай бұрын

    SOK needs to come up with a lifetime battery for smoke detectors.

  • @idahocartel

    @idahocartel

    10 ай бұрын

    😂

  • @AaronBlake

    @AaronBlake

    10 ай бұрын

    I started checking my home for it. LOL

  • @geekstradamus1548

    @geekstradamus1548

    10 ай бұрын

    DC house such as the one built by Purdue University. Then wire it in.

  • @DesertRatLife

    @DesertRatLife

    10 ай бұрын

    I honestly kept pausing to see if that was my smoke detector lol🤣

  • @maverickmacgyver
    @maverickmacgyver10 ай бұрын

    Now that’s an amazing way to harness all the power. I really like the serial hybrid approach. Great video!

  • @GavinStoneDIY
    @GavinStoneDIY10 ай бұрын

    Holy cow! What a setup. That is a lot of amperage potential.

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    Yeah. Not something you want to work on live.

  • @guytech7310

    @guytech7310

    10 ай бұрын

    Its a fully operation battle station and the battery bank is really for powering a super-laser! /joking.

  • @dangoras9152
    @dangoras915210 ай бұрын

    That's a badass set up there brother it has changed a lot over the years... Keep it up brother

  • @MyWasteOfTime
    @MyWasteOfTime9 ай бұрын

    That was a great video. I have one Chargeverter and it heats up my electrical room. I can't imagine how hot that room is!

  • @clarke6436
    @clarke643610 ай бұрын

    What a beast of a set up, very nice.

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    Thanks 👍

  • @YETI_B
    @YETI_B9 ай бұрын

    Love the content you put out! Please keep the videos coming!!

  • @rongray4118
    @rongray41185 ай бұрын

    For whatever reason I have been subscribed to you for several years but I have not been receiving any notifications from your channel. Deanna and I needed this information and video very much. Thank you. I am still attempting the best means to charge the 48 volt Absolyte 2,000 amp hour battery bank that we picked up for the mountaintop. Always good to see you! Blessings and Happy New Year ( a little late!).

  • @norsk54472
    @norsk544726 ай бұрын

    every time some one links to this video I have to come back and watch parts of it - LOVE this video and I share it

  • @davidschuerhoff7682
    @davidschuerhoff76826 ай бұрын

    We use an EG4 Chargverter in our system and it’s amazing.

  • @dc1544
    @dc154410 ай бұрын

    Awesome and a bit insane, I love it.

  • @jamisontaylor878
    @jamisontaylor87810 ай бұрын

    Bad ass thanks for the tour 😊

  • @daimonvilppu6439
    @daimonvilppu64399 ай бұрын

    Nicely done! Quite the system. I would love to see an IR cam on this system. Thanks for sharing.

  • @sanpietroprogettista9887
    @sanpietroprogettista988710 ай бұрын

    Wow, super cool. Thank you for sharing.

  • @1KGoffgridhomestead
    @1KGoffgridhomestead8 ай бұрын

    Thanks! what an awesome setup.

  • @AdamDeLay07
    @AdamDeLay0710 ай бұрын

    Oh yeah! More power!!!

  • @teseract
    @teseract10 ай бұрын

    Your video had me hunting for the smoke alarm in my house that had a dying battery then I realized it was YOUR dying battery. Whoops. :)

  • @jamisontaylor878

    @jamisontaylor878

    10 ай бұрын

    Lmfao yep 😅

  • @felaxchow207
    @felaxchow20710 ай бұрын

    One nice thing about those switching rectifiers is that it really don't care about the line frequency as much so long it is within 50 to 60 Hz. You're definitely getting the most out the generator by using it in 3 phase mode. Even if you lose a few chargeverters, definitely have enough redundancy to keep things going until you get them replaced. Maybe EG4 might come out with a budget rack mounted version for higher power configurations?🤞 It be one heck of a setup and much cleaner for larger installations...

  • @zaprodk

    @zaprodk

    10 ай бұрын

    I believe they would run off of straight DC. There is nothing inside that uses the frequency for anything. You just have to make sure the rectifier can handle the current if it's running half the diodes at 100% duty cycle.

  • @Deveak

    @Deveak

    10 ай бұрын

    Wish they would make a 24 volt version. I did find some cheap telecom rectifiers, pretty sure it’s the same as the EG4, just without the additional programming and charging functions. I plan on hooking up an mppt for proper stages charging. Downside is they are single phase 240 volt and at 120 volts they sedate to 2000 watts.

  • @randacnam7321

    @randacnam7321

    9 ай бұрын

    They would run off a wider frequency range than just 50cy to 60cy. 83⅓cy, 91⅔cy and 100cy railroad signal power would be no problem, nor would 40cy or 70cy (ancient AC standard frequencies). Only things that may be a problem are things waaaayyyyy outside of the normal utility frequency range like 25cy railroad traction power (insufficient bulk capacitance on the switcher primary buss) or 400cy aviation power (input diode switching speed, AC input shunt capacitor current and AC input circuit breakers; 400cy arcing is a right pig to interrupt).

  • @kansasadventure1831
    @kansasadventure18315 ай бұрын

    Speachless!

  • @davidb.5544
    @davidb.554410 ай бұрын

    All I can think of calling it is "the beast". Thanks for sharing.

  • @AveRage_Joe
    @AveRage_Joe10 ай бұрын

    WOW Crazy!!!! Love it!!!

  • @quandiy5164
    @quandiy516410 ай бұрын

    We have the similar genset but not enclosed. Bought new in the 90s and worked reliably. But recently, the avr burst into flames because it used the infamous Rifa paper caps. Fortunately was a quick fix there are lots of clones of the avr that used more reliable poly caps. Might want to check yours out, if the Rifa caps are cracked, they will burst into flames eventually.

  • @diylithiumguy
    @diylithiumguy10 ай бұрын

    Very nice! Also love the blue car... :)

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    Me too. Got it from a good friend.

  • @creamshop
    @creamshop3 ай бұрын

    Thats some serious charging

  • @awbean5254
    @awbean525410 ай бұрын

    THANKS, GREAT INFORMATION!

  • @mikef1570
    @mikef15704 ай бұрын

    No wonder I can’t find one in stock to buy this dude got them all 😂

  • @lasangap
    @lasangap9 ай бұрын

    Probably the largest DIY system I've ever seen on KZread. Lots of $...Wow....couple of generations can live off of this amount of money in my country.

  • @Scat.original
    @Scat.original10 ай бұрын

    AWESOME VIDEO, Thanks

  • @MattLesak
    @MattLesak10 ай бұрын

    This is awesome!!

  • @divlles
    @divlles10 ай бұрын

    I love how the fuel cap the fuel Inlet for the diesel tank it's just a galvanized piece of pipe with a threaded cap simple easy basic I gets the job done

  • @XonGrid
    @XonGrid7 ай бұрын

    Awesome!!!

  • @kevinhoober1863
    @kevinhoober186310 ай бұрын

    Looks like you have your phases well balanced...but that neutral is technically undersized. I would be interested to see what kind of current that neutral cable sees with the load of chargeverters, and if their loading stays balanced as the battery voltage comes up. Another scenerio where the neutral could see more current is if a few chargerters went off line...and happened to be on the same phase--seems unlikely, but still worth considering. Another option would be to forgo the neutral all together and run as a 208 delta (of course this would mean double pole breakers for the chargeverters). Love this content!

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    Neutral has 0 amps. The chargers are connected phase to phase. They don’t even have a neutral conductor. I only installed a conductor in case I need it in the future for ancillary items such as phase loss detection in my PLC

  • @kevinhoober1863

    @kevinhoober1863

    10 ай бұрын

    @@HighTechLab I went back and looked--can't believe I missed it the first time! For some reason I had it in my mind you were running the chargverters at 120V....after looking again @10:25 it is clear you have them phase to phase (208V). You certainly won't be overloading the neutral with the chargeverters. Super cool project!

  • @TRYtoHELPyou
    @TRYtoHELPyou10 ай бұрын

    I'm only a third the way thru but man, I'm really enjoying this so far 😂

  • @williamvaughan1218
    @williamvaughan121810 ай бұрын

    You should try a line reactor inline on the output of the generator to help filter the noise.

  • @solarforfuture
    @solarforfuture10 ай бұрын

    well to be fair... i only want one... always ran a charger rather than direct gen to inverter on my off grid set ups... cheap gensets too variable ... great mech room!

  • @michaelhardy195
    @michaelhardy19510 ай бұрын

    EMP proof good idea 👍

  • @peteasmr2952
    @peteasmr295210 ай бұрын

    Wow that was really cool. I’ve never seen european colour coded wires used in a US panel before. What a great setup! I really like this it turned out great. And will look even better when the lugs arrive. Its always good to have backups and redundancy and this really covers that greatly. Great concept and use case for this properties specific needs. And could benefit similar and other use cases.

  • @randacnam7321

    @randacnam7321

    9 ай бұрын

    Those are the colors of the AC input cable that the EG4 chargers use. It actually fits better in this case than the normal black/white/green of normal ICEA table E1 flexible cords as brown and blue are both established hot colors.

  • @peteasmr2952

    @peteasmr2952

    9 ай бұрын

    @@randacnam7321 Oh, that’s interesting. I didn’t know brown had an established code rule in NA systems. I have seen blue in 3phase panels in NA diagrams labeled as a Hot. And I’ve seen yellow/green striped as an accepted standard in one diagram for Ground. Cable wise I know it isn’t uncommon for cords that come with computer supplies in the US to use the typically European - Brown = Live, Blue = Neutral, and Yellow / Green = Earth standard. So I figure EG4 is just doing that as it seems to be a readily available cable option.

  • @randacnam7321

    @randacnam7321

    9 ай бұрын

    @@peteasmr2952 Brown is L1 for 277V/480VGrdY and 480V delta. Brown hot/blue neutral is the abominable IEC standard. The only thing it's better than is the old Soviet standard where L2 is _green._

  • @llamachef
    @llamachef6 ай бұрын

    I'm curious about your heat mitigation strategy for your chargeverters. They tend to run quite hot, and I own one myself. While I've ensured ample space around mine as instructed, the heat output is still significant. I'd appreciate any insights you have on managing this heat.

  • @spiralout112
    @spiralout11210 ай бұрын

    Well thats pretty neat!

  • @joshg1244
    @joshg124410 ай бұрын

    This is pretty cool. Hopefully you won’t need to use the generator once you get that extra solar uo

  • @jumping438
    @jumping43810 ай бұрын

    So glad I bought a Chargeverter! If they can handle this, they can handle my puny 7500watt generator.

  • @windysolar1Planet-Earth
    @windysolar1Planet-Earth10 ай бұрын

    How to go nuts on batterys and generators

  • @Evolution56
    @Evolution5610 ай бұрын

    That's an insane amount of chargers. EV's have chargers one 10th that size that can take anywhere from 50 to 350 kW. I wonder if one could be gotten to do the same job, but probably would need to be actively cooled. Anyway, very impressive setup. Good job. Edit: Opps! Those EV chargers are DC to DC! Yours is AC to DC. Max AC to DC in EV's is 19.2 kW that I know of and they are expensive.

  • @spiralout112

    @spiralout112

    10 ай бұрын

    Also EV chargers are generally liquid cooled.

  • @Sylvan_dB

    @Sylvan_dB

    10 ай бұрын

    The amps are also a problem. 50kw into a 50v battery is 1000 amps. 50kw into a 500v battery is only 100 amps. Less amps, smaller wires, less heat.

  • @whattheschmidt

    @whattheschmidt

    10 ай бұрын

    @@Sylvan_dB I bet within 10 years almost all EVs will be 800-1000V too even.

  • @mgkleym

    @mgkleym

    7 ай бұрын

    They really don't. The level 1 and 2 chargers are actually just a fancy box with a relay in it the actual charger is built into the car and usually only around 5 to 10kw max. The dc fast chargers that can do 50 to 350kw are entire racks of equipment somewhere off to the side of the "charger" you plug your car into.

  • @ejennings98
    @ejennings987 ай бұрын

    Solar panels are cheaper compared to batteries, but the generator is an awesome backup. I would love to see a video in the future of the system upgraded with lots of solar.

  • @joblessalex
    @joblessalex10 ай бұрын

    Damn. I'm incredibly impressed you can do all this seeing as you aren't even capable of replacing your smoke alarm batteries.

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    😂😂😂 out of my pay grade

  • @sspyder181
    @sspyder18110 ай бұрын

    Wow awesome

  • @AintBigAintClever
    @AintBigAintClever9 ай бұрын

    Given that you've got a finely-tunable load right there you could maybe perform some interesting tests on the generator to find the sweet spot where it's at its most efficient, not just for science but for practicality as you can hopefully save fuel. Fill the tank right to the brim, run for an hour at xx kVA load, measure how much it takes to brim the tank again. Repeat at different kVA loadings, either by adjusting settings or turning off balanced triplets of inverters. Graph and learn :) Worth running a three-phase socket off that panel as well? You've got a three phase diesel-powered supply available for the odd occasions when one would come in handy.

  • @NightshiftCustom
    @NightshiftCustom6 ай бұрын

    the 2 wires that are not hooked up on the oil pressure sensor I think need to be hooked up to make the connection to the controller and make it work right now it thinks it has no oil pressure and would go into shutdown without the ziptie you will prob need to buy a new oil pressure switch also as there maybe a reason it's unhooked awesome setup btw !!!

  • @JK_Vegas
    @JK_Vegas4 ай бұрын

    That is a beast of a setup! I'm curious how the Chargeverters are holding up now that it's been a few months. We are building a stronger charging solution for our off grid cell tower site. Have the Chargerverters kept their voltage and amp settings through all of the various generator cycles? Our generator is tiny in comparison (9500w). We have 2 Chargeverters along with the Victron Quattro 5000 charging which will be disabled most of the time in order to keep the generator 240v phases even. Plan is to back off the CV amps to keep the generator around it's peak 24x7 output rating. Generator only runs if there's multiple cloudy days. It's a very remote site so if the CVs settings get lost, they will overpower the generator if they go back to 100A.

  • @offgridwanabe
    @offgridwanabe10 ай бұрын

    Gazooks man what town are you supplying.

  • @shawnm.
    @shawnm.5 ай бұрын

    I am kind of surprised no one mentioned floating neutral on the old generator as being a possible cause. We have seen that issue several times where some generators either intermittently charge, or just don't charge the attached equipment at all. Some equipment is just better at handling the floating neutral that most generators are setup for. Hidden usually in the manual, often in just a paragraph or less there will be something about this but there is many videos out there that can explain the floating neutral issue and how to correct it, because it sure would have been cheaper than doing all this work.

  • @shadowsrwolf
    @shadowsrwolfАй бұрын

    if you were fancy you would set up some automation to auto start the charging gen, 12min gen cooldown and back to standby

  • @rv10flyer84
    @rv10flyer8410 ай бұрын

    3100aH home/1200aH shop. Our 10kW LP Generac plays nice with 12k’s.

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    This one did too when it was newer. Probably time for a valve adjustment and a tune up

  • @shaunnightfire8269
    @shaunnightfire826910 ай бұрын

    What a setup! About how long can your parents operate once the batteries are fully charged? Also, can you tell us more about why they went off grid or is this a vacation home setup?

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    Well over a week in cloudy weather and in spring and fall they can go only on solar. They typically only need to recharge after long periods of high heat or lots of cloudy days.

  • @trace9130
    @trace91308 ай бұрын

    It would be interesting to test fuel usage at different laods to see what what percentage load the generator gets it's best fuel economy

  • @themachine8427
    @themachine84279 ай бұрын

    @4:32 smoke alarm beep 😂

  • @rongray4118
    @rongray41185 ай бұрын

    When you heard the phrase as a young man, "Go Big or Go Home."... You took it Quite Literally!

  • @Electronzap
    @Electronzap10 ай бұрын

    Nice setup. Now that you've shown that, I've realized that the battery rack is pointless. Just save money and space by stacking them.

  • @slaveofjesus3878

    @slaveofjesus3878

    10 ай бұрын

    Earthquake protection? Is heat dissipation an issue?

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    I wish I had the battery rack to bolt them to the floor and keep some space in case there is somehow water intrusion to the room. The batteries make practically zero heat, so there is no thermal issue at all.

  • @lbroome
    @lbroome10 ай бұрын

    Nice video! How loud are the chargeverters at 85 amps output? Is the fan temperature controlled?

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    Not too bad, especially when compared to that monster generator. The fans are at full speed at 85A, but I honestly expected worse when I was installing them. The room doesn't really have much echo, so when you stand back 10ft it's not bad at all.

  • @Sylvan_dB
    @Sylvan_dB10 ай бұрын

    I guess some people do not hear smoke detectors chirping...

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    Lol…I tried changing the battery while I was there and it was still chirping. Time for a new one

  • @usmcp

    @usmcp

    10 ай бұрын

    Nip that code black in the bud 😂

  • @nooneswedish5142
    @nooneswedish514210 ай бұрын

    Finlay !! I can not understand why this is not the standard. to be honest the Inverter Charger combo is only god for RVs that frequent trailer parks. In any other setup you are better of separating the Inverter and Charger , and definitely having a charger that can tolerate "dirty AC".

  • @norsk54472

    @norsk54472

    5 ай бұрын

    I AGREE. It is was smart to timeslice the inverter/charger.....back in the day. But Today with cheap CVs, separate chargers makes more sense and provides simpler operation, saving the vital inverter for inverting I have a XW Pro and have switched to this model. ONLY use the inverter for loads, and not the internal charger to power charge battery (It is hooked up for possible emergency use) I have 2 CVs with 2 L14-30r from 2 grid circuits and 2 L14-30r from the 2 generator circuits. When solar input is low I can use either grid or generator to boost power. Save stress on the internal charger AND can have spare CVs at a cheaper price. LOVE this architecture model

  • @bearupfarm1818
    @bearupfarm18186 ай бұрын

    Hi, high tech lab. I have a question on the Chargeverter that maybe able to clarify. I am totally off grid. Signiture Solar tech recommended that I don’t charge my batteries with them being charged and discharging to run my house.when my solar panels not producing power. Have you ever have any problems charging your batteries and the inverter running with loads? Thanks for your opinion.

  • @JonOffgrid
    @JonOffgrid10 ай бұрын

    😮👍 wow

  • @BatMan-co1gy
    @BatMan-co1gy5 ай бұрын

    That's why my Chargeverter is on backorder lol

  • @danchesney631
    @danchesney6317 ай бұрын

    Change the battery in your smoke alarm.

  • @realeyesrealizereallies6828
    @realeyesrealizereallies68289 ай бұрын

    WOW.....

  • @adairjanney7109
    @adairjanney71098 ай бұрын

    prob could have stayed with the solarks with the new generator

  • @liljasere
    @liljasereАй бұрын

    **Removes glasses** "Mother of god"

  • @flinch622
    @flinch62210 ай бұрын

    It would be helpful to have a reactive load gauge [kvars] on that generator. PWM or SCR systems tend to have lousy power factors. That inverter disconnect seems odd on account of voltage is stable - you'd think it ought to be happy. But... does 240 from generator match inverter design? Spec sheet suggests 175-425v input, so that sounds fine. I have had charging systems in the past where they were sligtly under-specd for battery bank Ah capacity - they stood up fine, until battery age started demanding more current, and the charger failed from the mismatch -upgraded to a higher output charging unit and problem solved. So this was a video to watch: maybe battery overtemp and/or overcurrent was my first instinct regarding shutdowns. As for the newer bigger generator... what AIC is required? I was thinking main has to be 120,000? This is a fairly big project as details go. Throw some dessicant packs in that generator control panel to keep electronics happy over time - any cabinet outdoors has a way of breathing with heat/cool cycles day & night that can cause something approaching a mini rain forest inside. You might [might] need to pull back on charging volts to 54v?

  • @retrozmachine1189

    @retrozmachine1189

    10 ай бұрын

    Aye to this. I have no experience with these battery chargers, and in all probability never will, but it wouldn't surprise me at all if they have no PFC at all. I'd be happy to be proven wrong and find there is at a minimum passive but active would be preferable.

  • @AintBigAintClever

    @AintBigAintClever

    8 ай бұрын

    There's another possible option, which I saw in an LED emergency lighting unit designed for outdoor use. A little rubber bladder inside the panel, connected through to the outside. Pressure inside the cab drops, bladder gets bigger. Pressure rises, bladder shrinks. The one in the lighting unit was like a little rubber light bulb. For a bigger cab even something like a party balloon on a hose connector might do the trick. Video nel567DBAQc at 1:37 shows the one I encountered.

  • @ai4px
    @ai4px10 ай бұрын

    any issues with hitting the generator with all those chargeverters all at once? It would seem a good idea to have them switch on in groups of three thru a three phase contractor.... that way you can ramp up the load. Chargeverters don't softitart do they?

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    They do soft start unless you have them on and THEN flip on their DC breaker. I only ramped them up fast for the sake of not making a 20 min video

  • @margarita8442
    @margarita844210 ай бұрын

    need more panels

  • @Rumelectric
    @Rumelectric3 ай бұрын

    👍👍👍👍👍👍👍👍

  • @JoonasVaabel
    @JoonasVaabel8 ай бұрын

    Is it OK to stack 5 SOK server rack batteries on top of each other? The manual says 3 max. I ask because I also want to stack at least 5 without using the rack. Do the bottom ones get too stressed?

  • @HighTechLab

    @HighTechLab

    7 ай бұрын

    Depends on if you worry about having a warranty. For me, I am the warranty...

  • @ionut8091
    @ionut809110 ай бұрын

    way not use solar panels?

  • @mwolrich
    @mwolrich10 ай бұрын

    I think it might have been worthwhile to install the twistlocks off the breaker panel, and you should keep the DC wiring original/full length. The reason? Think about maintainance/warranty… It’s much easier to remove a plug, and send back a defective charger under warranty, to EG4 if it hasn’t been modified, also faster for you, as you won’t have to open the panel and loosen the screws on the 2 pole breaker.

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    This is true, but those boxes sure do take a long time to wire up…also I work directly with eg4 so warranty is trivial.

  • @Jennifer-007
    @Jennifer-00710 ай бұрын

    Here's a thought.... better solar panels, mounting, bi-facials etc..whew who wants to hear all that racket going... (face palming myself)

  • @kansasadventure1831
    @kansasadventure18315 ай бұрын

    Is this guy from current connected?

  • @Theoppositeofchaos
    @Theoppositeofchaos10 ай бұрын

    How big is your parents s solar system..PV array ?

  • @Scotty2Balls
    @Scotty2Balls10 ай бұрын

    Gonna mess around and catch that room on fire. Rumor has it those chargeverters double as a griddle.

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    That's the nice part of dialing them back to 85A, they put out way less heat.

  • @Scotty2Balls

    @Scotty2Balls

    10 ай бұрын

    @@HighTechLab Nice, the setup looks cool. Looking forward to the future videos

  • @pashko90
    @pashko9010 ай бұрын

    Sounds like you need to go to 360v systems.

  • @joakimcarlsen71
    @joakimcarlsen719 ай бұрын

    when i first read it i thought that 48v 1200A that really isn't a huge home battery, then i realised it said A and not AH. 57kw of charging power goddamn. The best i can do is 12kw with my 3phase deye. i have 1400ah of lead acid agms for my house consumption together with 18kw solar, My main fuses to my provider can only do 25A x 3 fuses. So i am hard limited to selling/buying about 17kw. Need to get thicker wires inside to get access to more power. I suppose this home battery has around 120 kwh then? perhaps for lifetime concerns about 90-100 usable kwh.

  • @keithcress1335
    @keithcress133510 ай бұрын

    Little confused; I thought you said it was a 480V generator. That would be phase to phase. How are you running 120/240V chargers off that? 277V to neutral would still be too much voltage. What did I miss? Also, are those chargers all completely Isolated so they don't care how their outputs are paired? Thanks. Lastly; You're not over "C"ing those batteries charging them back up almost all the way in only two hours? What's the allowed charging C rate?

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    I re tapped the generator for 208. Batteries are good up to 1C

  • @restfulplace3273
    @restfulplace327310 ай бұрын

    I’m surprised tsp many devices will operate in parallel. It feels very much out of code, at least in my area, YMMV.

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    No code articles against it...as long as all the conductors are sized appropriately, it's all good.

  • @joshuabest100
    @joshuabest1009 ай бұрын

    Damn who's is the gt3rs 🤩

  • @HighTechLab

    @HighTechLab

    9 ай бұрын

    That’s my Tesla model 3 GT3 BS. Look closely 😂

  • @joshuabest100

    @joshuabest100

    9 ай бұрын

    ​@@HighTechLabhaha that's good I like it

  • @ChadCourtneyTAZ427
    @ChadCourtneyTAZ42710 ай бұрын

    OMG change that smoke detector battery, please!

  • @wadebrewer7212
    @wadebrewer721210 ай бұрын

    That 14 kw would work great with my set up...lol...can I have it? 😂

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    lol it is going down to their well pump

  • @wadebrewer7212

    @wadebrewer7212

    10 ай бұрын

    @@HighTechLab it never hurts to ask. The worst answer is no. Nice set up by the way. That 6BT will out run everything on the property!

  • @profish71
    @profish712 ай бұрын

    How much does all this cost

  • @Jennifer-007
    @Jennifer-00710 ай бұрын

    Damn, someone gets an employee discount on batteries.... whew

  • @jamesgrabatin5520
    @jamesgrabatin5520Ай бұрын

    And you can heat the home while the batteries charge. #firehazard?

  • @michaelchownyk5255
    @michaelchownyk525510 ай бұрын

    That’s a really good job. I am going to build something similar to that. How many kilowatts of pv are online? How many more are you going to add?

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    12kW

  • @howtodave1725
    @howtodave172510 ай бұрын

    Add a windmill in front of the engine.

  • @HighTechLab

    @HighTechLab

    9 ай бұрын

    There’s already a generator head on the back of it…what’s the point?

  • @michaeld1959
    @michaeld19597 ай бұрын

    That Tesla looks familiar

  • @tachi98lep
    @tachi98lep10 ай бұрын

    No Solar panels?

  • @HighTechLab

    @HighTechLab

    10 ай бұрын

    They have about 12kw of solar, but it's not enough.

  • @jamesblackwell3745
    @jamesblackwell37455 ай бұрын

    Destroy the smoke alarm already!! #BEEP!

  • @kickgas7171
    @kickgas71716 ай бұрын

    Why?

  • @coreybikes
    @coreybikes5 ай бұрын

    Battery in smoke detector asap!

Келесі