Пікірлер

  • @MichaelPerry-ol7kk
    @MichaelPerry-ol7kk2 ай бұрын

    I got a sidebar troubleshooting tip! I have a “master” mixing valve under my bathroom vanity sink closest to the hot water heater. When the mixing valve fails it’s suppose to fail on the cold water delivery feed so as not to burn the user. My hot water issue was with my mixing valve not the water heater.

  • @SierraOperator
    @SierraOperator3 ай бұрын

    Thanks dad. The power company hit the main water line and gas line. The water company came out and did some repairs and I had no hot water after that. The filter was full of sediment. I took the filter out and let the water jet out for a few minutes. Had hot water right after that. 👍🏽

  • @bend7148
    @bend71483 ай бұрын

    Thank you, I just installed a new Takagi WH, I had the water backwards, took your advise and it worked. :).

  • @katiesimpson6851
    @katiesimpson68518 ай бұрын

    Our tankless waterheater has been working well for 6 months. This morning we had no hot water flowing through the unit. We have no error codes. It is 50 degrees around the unit, and the filters are clean. Do you have a suggestion?

  • @bradlewis461
    @bradlewis46110 ай бұрын

    How do you get it out of standby mode?

  • @emilydav2980
    @emilydav298010 ай бұрын

    This was an exact replacement for the old one that lasted about 10 years. kzread.infoUgkx7yWIKcrbA9KMHkGSfcgxW2lsjHT6B8Sh The top of my mitigation tube by my roofline was just a 90 elbow which allowed too much debris to fall down into the fan, eventually ruining it. Without this issue, I bet it would have kept running another 10 years. When I replaced this fan, I added an extra elbow joint so the top tube now it does a 180, which should solve that problem. The radon guys around here wanted to charge me a $300 diagnostic fee, then parts/labor (probably close to $600 total). I installed this all by myself in about an hour for the cost of the fan; it would probably be even easier/faster with two people. FYI the manufacturer's warranty greatly differs depending on whether you install it yourself (1 yr warranty) or have a licensed installer do it (10 yrs).

  • @seanweiss4647
    @seanweiss4647 Жыл бұрын

    Not sure if my water heater is older than that it was installed in 2021 but I don't have that whole panel in the front that shows you the flow and all that is that something you buy separately?. I'm having a no hot water issue but I have a blink code it's blink code number three apparently that says igniter issue somewhere I read online and I can't figure that out I clean the igniter rods they seem to be getting spark but it won't ignite the water heater

  • @sarafox4375
    @sarafox43752 ай бұрын

    I had mine installed last fall and no hot water... it happens in the shower and kitchen. I'll be trying out some of these today. Thank you. If there is a chance you can show the maintenence on an actual installed one. That would be great. I almost flooded my basement. 😮

  • @2u263
    @2u2633 жыл бұрын

    Could use a non condensing vent installation demonstration for Non Condensing Takagi110U-I

  • @carlysheff
    @carlysheff3 жыл бұрын

    So helpful and clear. Thank you so much!

  • @chefbambu9382
    @chefbambu93823 жыл бұрын

    Where do I find the water pipe (H&C) standards? Can PVC be used? what's referred and why? Thanks.

  • @rhdtv2002
    @rhdtv20023 жыл бұрын

    I think you can use CPVC

  • @dvcrocco
    @dvcrocco3 жыл бұрын

    PEX is commonly used.

  • @paddypointhound1688
    @paddypointhound16884 жыл бұрын

    my friend has a tankless heater,it has a tee in the cold water line going in the unit,and runs to the cold water knob in her shower,is this correct?..or does the cold water have to be seperate from the line going into the unit?

  • @joseartiaga3048
    @joseartiaga30484 жыл бұрын

    Do you need flex lines

  • @joseartiaga3048
    @joseartiaga30484 жыл бұрын

    That prv drain should be going outside

  • @vinjulieann1
    @vinjulieann14 жыл бұрын

    Plumbers charge way too much to install these or water heaters - on a $329 electric water heater they want to charge $1700 to replace it.

  • @socksincrocks4421
    @socksincrocks44214 жыл бұрын

    I thought a flexible gas line is not permissible. It must be hard piped, right?

  • @dvcrocco
    @dvcrocco3 жыл бұрын

    Depends on the local utility. NFG code allows a properly sized flexible connector. Still need a sediment trap, however.

  • @Rbelloc5
    @Rbelloc54 жыл бұрын

    Could you provide links to the Items you listed?

  • @jimwilson8509
    @jimwilson85094 жыл бұрын

    NOTHING MENTIONED about Exhaust system , type pipe, requirements

  • @rebelman1776
    @rebelman17764 жыл бұрын

    About time I saw someone install a sediment trap the right way

  • @Authoratah
    @Authoratah5 жыл бұрын

    should've installed special tank-less service valves

  • @RunE076
    @RunE0763 жыл бұрын

    They are called ISOLATION VALVES

  • @davenelson1638
    @davenelson16385 жыл бұрын

    Lol. You soldered pro press fittings. Thats funny. Maybe I can make videos too. How did the melted rubber from the o-rings work out in the heat exchanger

  • @sandman70131
    @sandman701315 жыл бұрын

    Is he soldering a propress elbow?

  • @BC-sk3bp
    @BC-sk3bp4 жыл бұрын

    No it's a yorkshire fitting. Oh yeah you can sweat a press fitting..🤣 But you gonna burn the rubber. 🤣

  • @exceleratorjoshua
    @exceleratorjoshua5 жыл бұрын

    2 gas shut off valves that close to each other are not needed. That check valve shown better be a spring loaded check valve, because if it's a typical swing check valve it's not installed correctly. Swing check valves can only be installed horizontally not vertically. Only problem I see so far is the lack of a shut off valve on the hot side. Reason being you won't have to shut down the whole building water supply if you have one shut off valve on each line. It also helps to do service or swap the unit out easier and quicker, no need to pull the TPR in order to drain the system or open up faucets and turn the whole building water supply off.

  • @dvcrocco
    @dvcrocco3 жыл бұрын

    I have never seen a check valve on an installation like that. Also, it is a swing check and will always be open.

  • @Hever73
    @Hever735 жыл бұрын

    No flashing kit! not exhaust vent pipe?

  • @jerodfox4856
    @jerodfox48565 жыл бұрын

    really nice video! Can you hook this up bellow grade and drain to a condensate pump?

  • @michaelnelson2951
    @michaelnelson29515 жыл бұрын

    Thanks nice overview, but, what about air supply and exhausting?

  • @jdubya54
    @jdubya545 жыл бұрын

    Awesome video. What about the flue

  • @sorghumcrow7289
    @sorghumcrow72895 жыл бұрын

    It's an electric model. You might as well look for a tailpipe on a Tesla.

  • @titan_3634
    @titan_36345 жыл бұрын

    @@sorghumcrow7289 then Why the gas feed line??? lol

  • @D_Snapp_Garage
    @D_Snapp_Garage5 жыл бұрын

    Does propane also require a drain leg?

  • @dvcrocco
    @dvcrocco3 жыл бұрын

    Propane is even dirtier than natural gas. I would use one.

  • @matuajohnson2060
    @matuajohnson20605 жыл бұрын

    On the hot side he went from metal to Copper that will cause electrolysis

  • @dvcrocco
    @dvcrocco3 жыл бұрын

    The tank connection is brass, which is dielectric.

  • @danixiri
    @danixiri5 жыл бұрын

    *Work perfectly.>>>**t.co/AP0CIosPu1** it keeps up with the Kitchen and Laundry room. we never run out of water and is hidden from sight. Great space saver.*

  • @IpodNutz
    @IpodNutz5 жыл бұрын

    How about the exhaust pipes? No mention on that.

  • @reedrobb
    @reedrobb5 жыл бұрын

    All that beautiful work, love the safety gear, but what about escutcheons? They would clean up the bad drywall around the pipe through the wall.

  • @j.feldmander1956
    @j.feldmander19565 жыл бұрын

    The proper plumbing kit for flushing the scale build up out of the heat exchanger is not shown or even discussed in this video. It all seems professional except for that one major oversight.