Zehnder ERV - 2 years Later at My House- Worth it

2 years later, Matt reviews his Zehnder unit he had installed at his home.
Check out Zehnder products here!
www.zehnderamerica.com/
Subscribe and follow my Podcast on Apple or Spotify!
Apple: apple.co/32AOwgU
Spotify: spoti.fi/3FXNg4X
Sign up for our twice-weekly newsletter:
buildshownetwork.com/newsletter
To sponsor a video or advertise with us visit:
www.buildproductions.com
Want to learn more about building? thebuildshow.com/
The Build Show on Instagram: / thebuildshow
Huge thanks to our Show sponsors Builders FirstSource, Polyguard, Huber, Rockwool & Viewrail for helping to make these videos possible! These are all trusted companies that Matt has worked with for years and trusts their products in the homes he builds. We would highly encourage you to check out their websites for more info.
www.bldr.com/
polyguard.com/
www.Huberwood.com
www.Viewrail.com
www.Rockwool.com

Пікірлер: 126

  • @TechnoCraftGaming
    @TechnoCraftGaming7 ай бұрын

    "A smart home needs a smart homeowner" Very true

  • @JeremyJohnson79
    @JeremyJohnson797 ай бұрын

    Thank you for not cutting this one short. Lots of extremely good information!

  • @superspeeder
    @superspeeder7 ай бұрын

    Two dedicated humidifiers and still high humidity? You need to plumb that Zehnder air through one of those dehumidifiers, Matt. You’ll save a lot of energy dehumidifying at the source (humid incoming air) rather than the mixed indoor air. For the price, Zehnder should be offering that feature built-in.

  • @mkkd85

    @mkkd85

    7 ай бұрын

    Or use an HRV instead..

  • @superspeeder

    @superspeeder

    7 ай бұрын

    @@mkkd85 in an air conditioned house in a hot humid climate, an HRV will bring more moisture into the house than an ERV will.

  • @superspeeder

    @superspeeder

    6 ай бұрын

    Exactly. There are few places in North America where an HRV makes sense. If you don’t know, you probably want an ERV.

  • @ericscott3997

    @ericscott3997

    5 ай бұрын

    Matt stated in the video that he was running the systems fan higher to push more CFM's through the home. Doing this causes the ERV core to absorb less moisture from the outside (and inside) pushing humid air throughout the home. He also stated he bumped the lower dehumidifier up from a 70 to a 90, but didn't say when or how long he had that bigger system. From my time living in Georgia, I'd have spec'd my dehumidifiers bigger to begin with.

  • @colinstu
    @colinstu7 ай бұрын

    28:01 the fact that Matt mentioned that his house was set to be slightly over-ventilated + the fact this wasn't running in Low/slow mode, makes me think that maybe that's partially/fully responsible for the slightly higher humidity levels. Esp considering he's in TX.

  • @fchiefe
    @fchiefe7 ай бұрын

    Thank you for your channel! You've given me confidence understanding building science and whats important with my parents' project to downsize homes. Our construction starts next week!

  • @markstipulkoski1389
    @markstipulkoski13897 ай бұрын

    What a great attic! Even after holding all that air handling equipment, you still have room to store some Christmas wrapping paper.🎄🎅🎁

  • @itsallwonky
    @itsallwonky4 күн бұрын

    I've done some digging and Zehnder is the ONLY HRV system I can find that can be integrated into home automation. There is a LAN/network interface available and Home Assistant does have support for it. Mobile app support too. Or, if you want KNX you can control via that system.

  • @wjthehomebuilder
    @wjthehomebuilder7 ай бұрын

    I can't believe it's been 2 years already!

  • @scottrodman4017
    @scottrodman40176 ай бұрын

    Many thanks Matt, Sean, and Szabi for that information. Szabi just commissioned our Zehnder units and I am excited to be moving in soon to enjoy a new experience of truly clean air. What a great experience it has been working with Szabi and Charlie for our project, Build Show Boston. This video reminded me of the important service needs and timing for our Zehnder units. Now on the calendar! As always Matt, your content makes a huge difference and has encouraged so many people to take our own steps forward.

  • @pennguino9137
    @pennguino91377 ай бұрын

    That Radon exchange was eye opening. Just by not having make up air for it to suck that Radon up into the house. You have to assume his house does not have a barrier membrane under the slab/crawl space.

  • @sdhlaw1
    @sdhlaw17 ай бұрын

    All your shows are good. This one is EXCELLENT!

  • @greennixon00
    @greennixon007 ай бұрын

    You never opened the core to see the inside!

  • @robertbryan6189
    @robertbryan61897 ай бұрын

    I wanted to see the core get cleaned. Good video.

  • @kenbode8806
    @kenbode88067 ай бұрын

    Great episode, thank you for sharing!

  • @pennguino9137
    @pennguino91377 ай бұрын

    Wow! 2 years already. Thank you for everything I have learned about building science. Hopefully my funds will be enough to employee all of these lessons on my final Toe Tag home.

  • @alantittle299

    @alantittle299

    5 ай бұрын

    Hahaha. Toe Tag. Pretty much my ambition for my pending build in east Texas Piney Woods, with probably more humidity. Despite our mold issues and knowing we should manage to 40 to 55% humidity for comfort and health these issues would have partially escaped my attention. I will have great living space with a view and a prevailing breeze passing over a lake so my ambient humidity will go up more. We need to think of the “living system of building science”.

  • @robertwalter2841
    @robertwalter28417 ай бұрын

    Excellent, Just that simple! Thanks

  • @dosadoodle
    @dosadoodle7 ай бұрын

    I really appreciated this video -- great tips! We're doing mini-splits + Zehnder as part of our renovation of a 100 year old home. The overall costs of this setup is very marginally more than a similar heat pump ducted system with a lower priced air exchanger (which would also be less efficient). For instance, we were quoted at a $5k difference on mini-split vs a ducted heat pump system. We also are happy to not give up any square footage for ducting and such, because the Zehnder ducts are able to fit in 3.5" stud walls and so don't require their own space. Whenever we can save square footage, I translate that into the value of the square footage, so our setup also is basically adding $2000-ish in value / space. Being in MN, I'm also eager to get as much efficiency as possible, and during the coldest months, my back-of-envelope calculations suggest we'll save $25-40 per month thanks to 90% efficiency vs 60% efficiency, and that'll translate to about $150 saved over the winter season.

  • @bastiat691
    @bastiat6917 ай бұрын

    Sounds like the 6 month mark is in Switzerland where the air is clean :D

  • @andybrooke1961
    @andybrooke19617 ай бұрын

    Great video Matt

  • @kylepeavy
    @kylepeavy6 ай бұрын

    That was an awesome video! Glad you didn't cut it short.

  • @wink9970
    @wink99707 ай бұрын

    Nice video and lots of needed knowledge transfer.....

  • @HAVENIAQ
    @HAVENIAQ7 ай бұрын

    Brilliant video 👏the 29 min soundbite from Sean is 😙👌

  • @billcunninghame8554
    @billcunninghame85546 ай бұрын

    Very informative video. If I'm ever in the position of building or remodeling a home, I'd definitely add a Zehnder ERV. It would be great if they added a sensor that detects when the intake or outtake filters need to be changed vs. a set number of days and notifies the resident.

  • @tullgutten
    @tullgutten7 ай бұрын

    I only have a diy system in my 50's ld house that im renovating and it is a medium large HRV from China and it works great. It is controlled on demand by 2 seperate Co2 sensors, 3 VOC sensors, 4 temperature and humidity sensors, and one dust/PM2.5 sensor. The air quality in my house compared to a friend with a 2014 house so much better than his constant low system. I did probably go twice the size i needed so it's most of the time off and only low speed. Never had stuffy nose, itchy eyes or bad smell innside ever since i got it Only wish it was ERV instead of HRV core

  • @jamesphillips2285

    @jamesphillips2285

    5 ай бұрын

    Did not know there was a difference between the two: so looked up the difference. From natural-resources Canada: "During the heating season, the HRV captures heat from the stale air leaving your house, and uses it to preheat the fresh air coming into your house. Similarly, an HRV can reverse this process during the cooling season, removing some of the heat from the incoming air and transferring it to the outgoing air." "An ERV can give you more control over moisture levels in your home during warm and humid weather, by keeping excess moisture out of your home. ... If your winter climate is extremely dry, ERVs recover some of the moisture that would leave your house through a regular HRV."

  • @walnutcontractors5661

    @walnutcontractors5661

    3 ай бұрын

    What is the brand? Biggest thing with zehnder is the efficiency of the core for heat exchange. what is yours rated at?

  • @raymondpeters9186
    @raymondpeters91867 ай бұрын

    Nice!!

  • @vahidtaeed665
    @vahidtaeed6657 ай бұрын

    30:10 - "I've also learned, on two stories houses I don't ever try and heat and cool a two story house with one system. I also don't dehumidify a two story house with one system". Can you unpack this statement, maybe with a video? Basically balancing floors with one system in a seasonal environment vs separate systems for each floor. An important topic with very limited coverage online. I'd thought (hoped?) that passivhaus could get away with one central system given the limited loads and good mixing. Your statement seems to confirm this is not the case and that it is safer to have one system per floor.

  • @DeuceDeuceBravo
    @DeuceDeuceBravo7 ай бұрын

    Bought a couple air quality monitors recently. Shocking info. Our radon tested fine when we bought the house, but pressure changes cause it to rise significantly. We were also amazed at the CO2 levels generated by two people and a large dog. The PM2.5 spikes to unhealthy levels whenever we are cooking. The house is roughly 1500sf ranch from the 70's but it's relatively well sealed considering its age. I'm trying to figure out how i can retrofit an ERV to alleviate these issues. So if you buy an air quality monitor (and you should!) then be prepared for nasty surprises.

  • @todd5963

    @todd5963

    7 ай бұрын

    What kind of monitor did you get? Don't send a link or they'll think you are spam. I'm considering a new one but want to get a good one.

  • @DeuceDeuceBravo

    @DeuceDeuceBravo

    7 ай бұрын

    @@todd5963 I got a couple different ones... Airthings which does basically everything, and the Aranet4 which is smaller and more portable but doesn't measure all the stuff that the Airthings does.

  • @colinstu

    @colinstu

    7 ай бұрын

    @@todd5963 yeah I'm curious as well

  • @thatguy7705

    @thatguy7705

    7 ай бұрын

    The AirThings line is pretty good. You can connect them to the internet and track trends. Some of them can talk to one another too. I have a “View Plus” model and I’ve configured it to display the radon & CO2 levels.

  • @todd5963

    @todd5963

    7 ай бұрын

    @@thatguy7705 That does look like a nice one, that is what I was looking for. Thx! Onsale for black Fri, bonus!

  • @JeffreyMota
    @JeffreyMota7 ай бұрын

    Make this a series ( 2 year later ) worth it? Regrets? On wall compositions, material, Plumbing, electricity, windows doors, and so on all the details

  • @raymondpeters9186
    @raymondpeters91867 ай бұрын

    Fixing the humidity problem is easy to solve Just dehumidifi the incoming air Bury a 6" conduit 8' underground for incoming air When the hot moist air hits the cold conduit it will condensate before it gets to the ERV unit Take care Ray

  • @walnutcontractors5661

    @walnutcontractors5661

    3 ай бұрын

    and then you have a pool of water sitting in the conduit. organics will be pulled into the conduit and mix with the water. mold will eat the organics and you'll dirty fresh air.

  • @Coleen_West
    @Coleen_West7 ай бұрын

    Interesting! -- QUESTION -- Matt, there are some interesting medical stuudies emerging on "mineral wool" insulation and it has some cause of concern. That circular EXIT filter in the attic (behind the cardboard) seemed to have Rockwool coloring in it. ALSO, the top of your large silver ducts have dust that looks exactly like Rockwool particles. Just do a safety test on that filter and see if there are Rockwool particles in it - I suspect that it is. If so, cover up all the rockwool in your atic behind drywall or poly barier - in fact, do it either way as this is a real issue - love Rockwool but it MUST be covered and sealed perfect. You cannot get that out of your lungs if it is. You may be in danger so take steps.

  • @MrBrianDuga

    @MrBrianDuga

    7 ай бұрын

    Do you have a link to these studies?

  • @Coleen_West

    @Coleen_West

    7 ай бұрын

    @@MrBrianDuga ..there are lots of studies. It looks like it will have similar effects on lung / cancer incidence to asbestos as it is essentially a product substitute. QUOTE: "Based on these studies, the International Agency for Research on Cancer (IARC) classifies RW as group 3: limited or immature carcinogenicity in animals, and unclassifiable carcinogenicity in humans" Simply google "mineral wool rockwool lung cancer". California recognizes it as a Group 3 carcinogin (carcinogin means something that causes cancer). The problem is these materials NEVER get disolved by the lungs - they stay there forever and inflame and infect the cells and the inflamation, over years, causes cancer in the cells. (normal dust does get absorbed and passed out the system). DO NOT BREAT THAT STUFF IN. If you do use RW in a house, make sure it is sealed perfectly (but history shows that you can't seal it properly). Really, as much as I love that stuff, just use closed cell spray foam and be done with it. Too risky and history shows that it, RW, always always finds a way to become airborne and escape. Just the air pressure in that house could make that dust airborne. There are sings all over the attic of just that. Those filters don't have brake dust - they have Rockwool dust imo - same color and same fine dust look. Certainly test that exit filter and see. Plus all that dust on top of the large ducts has RW dust that fell on it from above.

  • @dragon050417
    @dragon0504177 ай бұрын

    Love watching the channel. Wouldn't it be better to have 2 ventilation systems on a multilevel house as well?

  • @chrislambert4885
    @chrislambert48857 ай бұрын

    Fascinating stuff. Would love to see more about how all of your environmental systems work together in your house. Also, is the ERV system you have only for new builds? Is there anything out there for retro fitting into older homes?

  • @DrWarBear

    @DrWarBear

    7 ай бұрын

    I know a lot of ERV manufacturers (probably Zehnder included) have installation options where you can plug the ERV into the existing HVAC ductwork (essentially the incoming make up air goes into the AC supply, gets conditioned and then goes into the home, and then the AC return has a small off shoot that pulls a small of air back to the ERV and that becomes the exhaust that leaves the house - if that makes sense). That may be an option for retrofit where you don’t have the luxury of installing dedicated ductwork for the ERV separate from the HVAC

  • @MerkDolf
    @MerkDolf7 ай бұрын

    Feels strang comfortable tempture outside I've got the doors and windows open air moving through, and now thinking I'm goung th stop that and wse electricity to move the air through a folter and energy recovery system.

  • @xiowolf3
    @xiowolf37 ай бұрын

    Would love an update on the water filter.

  • @VernBigDaddy
    @VernBigDaddy6 ай бұрын

    Good thing you insulated over 2 years ago. That Mineral Wool would be impossible to get and you would pay big bucks for it today. Lead times on mineral wool batts are close to 200 days right now.

  • @ilickspam
    @ilickspam2 ай бұрын

    if you're using hvac units that run low fan speed constantly, why not connect the erv to the dehumidifier first? then dump dehumidified fresh air into the supply plenum? they can still go through all the filter boxes. genuine curiosity

  • @mlchemwolf
    @mlchemwolf6 ай бұрын

    Could you fit a screen box for the air intake. To keep bugs out

  • @boeing757pilot
    @boeing757pilot7 ай бұрын

    Great info! Im curious the yearly operating costs of this unit? How much power does this use? Thanks to anyone who can answer..

  • @ritste1654
    @ritste16545 ай бұрын

    Being close to an interstate, I lived next to I-4 in Orlando for a few years and dust is a nightmare. Could you install a prefilter in the duct going into the unit to help extend the life of the Zehnder filter, which I am sure is a bit more expensive than a cheap merv 4 or 6 standard size filter. Of course you have to consider that the flow of air is affected by the prefilter.

  • @steven7650
    @steven76507 ай бұрын

    @zehnder america, since the unit is internet connected, why not have it automatically look at the weather. It has humidity sensors, why not add an outdoor sensor that adjusts for the outdoor humidity?

  • @rogerwhiting9310
    @rogerwhiting93107 күн бұрын

    What would be a good stand alone air quality meter to put in my house NOW...to see what I have BEFORE anything else?

  • @petersallay5221
    @petersallay52217 ай бұрын

    We had the same experience with our ERV in the dead of summer. The humidity would creep up and I would have to ramp down the ERV. Then the CO2 would go up! Finally we installed a second dehumidifier which was over sized to make sure we could keep our indoor humidity at 45%. We definitely enjoy the indoor air quality but what percentage of homeowners can afford this? We invested in the equipment because we had the knowledge from you and others. We made it a priority. Most homeowners have no clue about IAQ. If the topic is brought to their attention they typically balk at the cost.

  • @boeing757pilot

    @boeing757pilot

    7 ай бұрын

    That was my question.. Do you mind sharing costs? I live in an area that has LOW humidity.

  • @davidscribbins9192
    @davidscribbins91927 ай бұрын

    Shouldn't you replace your erv core with a hrv core to save on use the the dehumidifiers ?

  • @SlackerU
    @SlackerU5 ай бұрын

    I think it might be cheaper to just have the home ac thermometer in a hepa-filtered intake-room with a variable-speed high-pressure blower which would intake 15-CFM per person & possibly 55-cfm(or whatever) for the clothes-dryer, & 30 CFM for the stove-hood or bathroom vent... having it automatically intake filtered air with the needs of the home might be even more efficient than 24-hour mixing. The ac already distributes air.

  • @matthewlacombe2146
    @matthewlacombe21467 ай бұрын

    Why don’t they make an ERV and dehumidifier in one? The only one that I can find is CERV. It is crazy expensive. Also I live outside of Huntsville Alabama and need to get ERV and dehumidifier but it seems there are no installers around here. We are big DIYers, in fact we are building our own home so I’m ok with installing. We are using ductless mini splits so we can’t incorporate the system into our hvac. Thanks for all the info.

  • @js-wq6zy
    @js-wq6zy7 ай бұрын

    You could build your design which adds a pre-filter, ie a less expensive ....

  • @jonerlandson1956
    @jonerlandson19567 ай бұрын

    that is a great demonstration of how air quality can affect our health....

  • @steven7650
    @steven76507 ай бұрын

    Zehnder europe has a model with dehumidification. Unfortunately they can't bring it to the US yet because of the energy penalty running dehumidification.

  • @MrJramirex
    @MrJramirex7 ай бұрын

    I'm sold... but the price is very prohibitive. The quote I got 2 years ago was roughly $12k for the unit and parts only. Can't even imagine what people pay for parts and labor to install a system like this.

  • @StealthNinja4577

    @StealthNinja4577

    7 ай бұрын

    So you'd get a heat exchanger, a dozen filters, several boxes, a bunch of ducts, and a cheap android phone... I can't imagine the cost to them is more than 500 in parts so you're paying for all the units they don't sell, Matt's ad, and everyone's salaries at the company.

  • @ilickspam
    @ilickspam2 ай бұрын

    you personally need to clean each filter per exhaust as well? what happens if you dont have those filters per exhaust port? it's exhausting and going to the filter before the core anyway.

  • @tweake7175
    @tweake71757 ай бұрын

    Why is the 2nd filter after the erv? Wouldn't it be better before so it keeps the erv clean and so you're not replacing the erv filters as much $$.

  • @chipmhandle
    @chipmhandle7 ай бұрын

    I still don’t think the Merv ratings are high enough! I hope you have other air purifiers in your home

  • @supersuper7610
    @supersuper76102 ай бұрын

    all the air in and out...on winter and summer is your HVAC running all time? and your energy bill high???

  • @luixmod1
    @luixmod15 ай бұрын

    Matt your humidity problem I think is because you have a ERV, if you change to an HRV you could reduce your humidity. what ZEHNDER said?

  • @davidhoover2446
    @davidhoover24467 ай бұрын

    Everyone talks code and theoretical cfm for ventilation. However, I always wish to see actual air quality data - PM2.5, TVOC, and C02 averages and see if it’s actually enough ventilation. The only one’s doing it are Build Equinox with their CERV2 ventilation which ramps up and down based on the pollutants present in the house. In my house, I just have fresh air and a dehumidifier dumping into my A/C return. With 2 adults and a child to see good air quality all the time I’m moving about 120CFM. I think once our family grows I’m going to have to upgrade because I’m at the most my dehumidifier can handle. To me, I would think 160 cfm is about right and with your size of family, I’d like to see actual calibrated VOC and C02 monitoring showing healthy levels (under 800 C02 and 125 ppb average TVOC).

  • @danielherman9483
    @danielherman94837 ай бұрын

    It doesn't look like Zehnder is readily available (least not as my local supply house) - looks like it would be extremely cost prohibitive to get one installed. Do you have any opinions on some of the more readily available brands like Panasonic, Fantech, Broan, or Aprilaire? I've seen you work with Panasonic and Broan in other videos, would be neat to hear your thoughts on what ones you'd choose for retrofit.

  • @DeuceDeuceBravo

    @DeuceDeuceBravo

    7 ай бұрын

    Zehndwr is VERY expensive. The build quality is awesome but it's overkill for anyone on a budget (like 99% of us). All the brands you mentioned will do the same thing.

  • @mitchdenner9743
    @mitchdenner97437 ай бұрын

    I'd like to know the effect on static pressure that secondary merv 15 filter box has on the system.

  • @apex007

    @apex007

    7 ай бұрын

    It was clearly designed around that filter. Why are u concerned?

  • @paulpoco22
    @paulpoco227 ай бұрын

    Can you reuse an old furnace exhaust(goes from 1st floor to 3 floors then out roof) as exhaust air for ERV or HRV? Already have fresh air intake but only 4" and don't want to punch another hole in the wall.

  • @MorryB

    @MorryB

    7 ай бұрын

    There are also dual ported (tandem) inlet/outlet fittings that allow you to use a single hole for an HRV. 4" might be a bit small for these however.

  • @RichsClub
    @RichsClub6 ай бұрын

    How much are one of these units going for?

  • @morganoverstreet6824
    @morganoverstreet68247 ай бұрын

    Matt- assuming my house is between 3 and 5 ACH50 is there even a need for an ERV at all?

  • @clinta746
    @clinta7467 ай бұрын

    I keep wondering if this type of system is appropriate in a house in the far north that does not have AC or dehmidification. We spend summer with the windows open. But in the winter it would be very beneficial to be able to bring in fresh air without losing heat. Do we still need an ERV? Or is an HRV more appropriate?

  • @StealthNinja4577

    @StealthNinja4577

    7 ай бұрын

    I mean with a Honda HRV you can at least go places in it

  • @woodlyz

    @woodlyz

    7 ай бұрын

    We just build a new house with a 1.05 blower door. We added an hrv for ventilation due to the need to keep the humidity lower in the winter time.

  • @afbigfish1
    @afbigfish16 ай бұрын

    The new Broan AI units look to be the ones to buy.

  • @blt981
    @blt9817 ай бұрын

    Can you explain with the system I don’t know what it is…

  • @Actio83
    @Actio836 ай бұрын

    Can i just buy the ERV core?

  • @peterdeluca6516
    @peterdeluca65164 ай бұрын

    I find it hilarious that Zehnder doesn't publish actual performance data (core efficiency) at various flow rates like all other manufacturers do. The only single datapoint I can find is "up to >90% in the HRV". The Zehnder rep "accidentally" mentions that the efficiency drops as the flowrate increases. How can you say you are the most efficient and "best" if you won't publish the efficiency of your core to compare against other brands? I did a lot of research and am going with a Renewaire Premium L,which is above 81% efficient for ~120cfm flow (and 88% efficient at 59cfm). As with all things you see, always do your own research and compare, don't assume what you hear about "this is the most efficient" is accurate.

  • @jonerlandson1956
    @jonerlandson19567 ай бұрын

    the pipe tunnel...

  • @danielwoodard680
    @danielwoodard6807 ай бұрын

    great series. I have been watching these episodes several times with architects and builders for 5 years. I Could not hear the zehnder rep re his house. Please match volumes in off-mike conversations in future videos.

  • @harveypaxton1232
    @harveypaxton12327 ай бұрын

    How does this interact with a house with gas-fired appliances.

  • @flynjay7178
    @flynjay71787 ай бұрын

    Tight houses should have heat pump dryers.

  • @zenrook1
    @zenrook17 ай бұрын

    33:42 “Our house has 0.14 ACH” Wow that is crazy low. Matt’s house is 0.60 ACH 50.

  • @rocky7gd
    @rocky7gd7 ай бұрын

    After 2 years a sensor gone bad already?

  • @steveksi
    @steveksi7 ай бұрын

    Nice. Unfortunately most builders are just very basic. And quality on normal stuff leaves a lot to be desired. You do a great job. Cost is always an issue. Making things like this code is the only way the masses can get top quality environments to live in.

  • @StealthNinja4577
    @StealthNinja45777 ай бұрын

    So not only do I have to hit this unit up every 6ish months but I gotta run around to every room and clean another filter in each one... I really think you should wear a full face mask at minimum when you're outside if not a hazmat suit or some bubble iron lung combo. I remember when hypochondriacs weren't obsessing over the air they breath to this extent

  • @MorryB

    @MorryB

    7 ай бұрын

    Matt has filters for his filter's filter!

  • @JeremySpidle

    @JeremySpidle

    7 ай бұрын

    Smoke 'em if ya got 'em!

  • @jamesphillips2285
    @jamesphillips22855 ай бұрын

    8:45 Would be better if the system supported Home Assistant integration, allowing the user to program that themselves. Edit: they let the user change that in the menu on the machine.

  • @itsallwonky

    @itsallwonky

    4 күн бұрын

    There is a network interface available and Home Assistant does have support for it. Mobile app support too. Or, if you want KNX you can control via that system. I've done some digging and this is the ONLY HRV system I can find that can be integrated into home automation.

  • @tristanmartinez2667
    @tristanmartinez26677 ай бұрын

    BUIIIILLDDD SHOOOOWW LESSSSSSSSS GOOOOOOO 💪🏽🫡

  • @ABC-wz2db
    @ABC-wz2db7 ай бұрын

    Need more nerd.

  • @pleka
    @pleka7 ай бұрын

    "I want to get your unfiltered comment..." nice

  • @JeremySpidle
    @JeremySpidle7 ай бұрын

    Those are some TINY filters, Zehnder... bet they want $50 apiece too?

  • @nedunonnyp704
    @nedunonnyp704Ай бұрын

    I Wonder How Much those Filters Cost.. ?? And You Probably Can Only Get Them from Zehnder.. ?? 🤔🤔

  • @johnzach2057
    @johnzach20574 ай бұрын

    Matt for the love of God, you have the money. Install an activated carbon filter. They will only help.

  • @walnutcontractors5661
    @walnutcontractors56613 ай бұрын

    Why would you put the comfo 320 filter box after the air has passed through the core? I suppose the idea here is that you've removed all the larger particles before the air enters the core and then you pass the air onto the MERV 15 filters. It wasn't clear what the filter stack was in the 320. you removed the 2 merv 15? filters with the yellow but it looked like there were some white prefilters? Thank you for the video! Beats reading the manual. I'll wait till you do a washing the core video before I wash my core - lol. Couldn't wait. Found a video though it misses setting the unit to service mode. kzread.info/dash/bejne/ZJufrchvYJrRqqg.html

  • @gsantee
    @gsantee7 ай бұрын

    Nasa taking notes for a friend.

  • @21trips
    @21trips7 ай бұрын

    Lots of maintenance for that little thing

  • @MerkDolf
    @MerkDolf7 ай бұрын

    Now if they only came with their own solar system and 10 day battery back up.

  • @tristanmartinez2667
    @tristanmartinez26677 ай бұрын

    Instead of inhaling these debris in small amounts over time you inhale them in concentrated amounts all at once while changing filter. 🤔

  • @MerkDolf
    @MerkDolf7 ай бұрын

    😀 👍👌.?.

  • @jamesoncross7494
    @jamesoncross74947 ай бұрын

    What happens if the grid goes down long term?

  • @4himsanctified

    @4himsanctified

    7 ай бұрын

    mad max

  • @mrstinky2421

    @mrstinky2421

    7 ай бұрын

    Generator

  • @DeuceDeuceBravo

    @DeuceDeuceBravo

    7 ай бұрын

    What's "long term"? And what is your concern with a power outage?

  • @MorryB

    @MorryB

    7 ай бұрын

    You....open the windows! :O

  • @apex007

    @apex007

    7 ай бұрын

    You die from farts not being able to escape the house

  • @Omnis2
    @Omnis27 ай бұрын

    If you live in south Florida and put an ERV in your home, all you'd be doing is blowing in all the neighbors' weed smoke. It's awful here.

  • @markrice3019

    @markrice3019

    7 ай бұрын

    🤣 🤧

  • @markrice3019

    @markrice3019

    7 ай бұрын

    🥳 🤠

  • @benzun9600
    @benzun96007 ай бұрын

    super cool system, but maintenance what a pain. I built a new home well insulated well ventilated. NO AC NO CENTRAL HEAT. We just heat with cove heating in bedrooms and gas and wood in master and living area. Very little maintenance.

  • @dlg5485

    @dlg5485

    7 ай бұрын

    Changing a couple filers 2x per year and washing the core every 2 years is too much for you?

  • @greennixon00
    @greennixon007 ай бұрын

    First

  • @publicmail2
    @publicmail27 ай бұрын

    We will start to see sick people in these air tight homes, because they won't maintain these units or they will break.

  • @iandouglas4992
    @iandouglas49927 ай бұрын

    Spend enormous money to insulate the crap out of the house to the point you need makeup air, and gas stoves become an issue due to no drafts. Etc etc. Seems like it's not worth it longterm