Here we describe the Basic settings of the YD6016LN-CS and the YD6016ES-CS. These units are designed to give you feedback detection for your model railway. There work with all the main computer control software like iTrain, Train controller or Windigipet.
The units are available from us at DCC Train Automation using the links below.
www.dcctrainau...
www.dcctrainau...
All manuals are in English.
www.yamorc.de/d...
More information on these units coming soon.

Пікірлер: 57

  • @dcctrain
    @dcctrain Жыл бұрын

    Nice!

  • @ClinchfieldModelRailroad
    @ClinchfieldModelRailroad Жыл бұрын

    During operation, if the S88’s are close by, you can use the e-link without a S88 “network cable”, correct ?

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    Yes that’s right you can use the ES-link joiners to do that.

  • @jimosipowicz8179
    @jimosipowicz81794 ай бұрын

    James thank you for the videos on YaMoRC. I was wondering if they make a board for reverse loops? I have an n-scale layout with 5 reverse loops in it and will be using Digitrax and Train Controller for my system.

  • @FormallyknownasE100
    @FormallyknownasE100 Жыл бұрын

    Perfect thank you :D

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    You're welcome!

  • @nicholassunshine
    @nicholassunshine5 сағат бұрын

    Can i distribute the ES units around the layout and just use cables and do the same thing? I need five modules total, and that seems like a good idea if possible.

  • @DCCtrainautomation

    @DCCtrainautomation

    4 сағат бұрын

    You an as long as the total length of the s88 cable connecting all the modules together does not go longer than 3meters.

  • @nicholassunshine

    @nicholassunshine

    4 сағат бұрын

    @@DCCtrainautomation Thanks James, I think I'll stick with the CS version in the video instead for them all in that case, just seems easier for me then

  • @philabernathy1868
    @philabernathy1868 Жыл бұрын

    Thanks for posting this video. I do not have one yet, but I am not clear about using as inputs for LocoNet sensors. My plan was to have a 10kohm resistor across the track (basically, using the common on the YD6016LN) with an inline switch (or momentary pushbutton) which would close to activate detection/input. Then I presume a LocoNet message would be generated for that input (LS17 is Active, for example) that could be used in JMRI with Logix to effect whatever I want (turnout, accessory, sound, script, etc). Or is it simpler than that by configuring the board differently (like the Turnout function)? Phil in gorgeous Young Harris, Georgia, USA

  • @saintpara1980
    @saintpara19809 ай бұрын

    Where are these units drawing power from? Do you have to have the usb (?micro usb) plugged in to the Loconet unit to power them all? Cant see anywhere in the manuals about it!

  • @DCCtrainautomation

    @DCCtrainautomation

    9 ай бұрын

    Hello sir. So these units can be set up and firmware updates by the USB. Then when in operation and connect to loco-net they then get power from there. All the detection information is sent back to the command station over loco-net. The track power in the detection side then comes from the command station track power or the booster.

  • @saintpara1980

    @saintpara1980

    9 ай бұрын

    So powered directly by Loconet? That's helpful. One less cable to run! 👍🏻👍🏻

  • @HumancityJunction
    @HumancityJunction Жыл бұрын

    Would it be possible to do a comparison between the YD6016LN-CS and the DR4088LN-CS?

  • @LocGeek
    @LocGeek Жыл бұрын

    Thanks so much for those great videos! Those products look great and I'll definitely need to test them on my layout and on my blog. One thing that's still unclear to me though, is YaMorC's YaB approach (Yet Another Bus 😉) with the ES-Link. Although I love the idea of being able to configure/upgrade all modules through ES-Link, it's unclear (as already asked below by someone else about the S88 modules) when the ES-Link can be used in day to day operation, and not only for programming. So, say I decide to go with two YD6016LN-CS with Loconet (no S88 modules). Can I operate them with only one connected to the Loconet bus, but both modules connected together through ES-Link. If possible at all, and would I loose any functionality? Keep up the great videos!

  • @yamorc

    @yamorc

    Жыл бұрын

    Hi two YD6016LN do not connect through ES-Link amongst each other. Behind one YD6016LN one can link-up upto 5 YD6016ES by using either cable or ES-Link

  • @iangray9596
    @iangray9596 Жыл бұрын

    Hi, when used as a feedback sensor, how does this work in a reversing loop situation? I want to place feedback sensors on a reversing loop block, where the polarity will change. At the moment, I use a GM auto reverse module, but what would be needed with the Yamorc unit?

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    Hello Ian yes this is possible but not with the reverse loop module you are using. Please call the shop to talk to us. I did a video on this years ago but need to up date that. As things have moved on a bit.

  • @kodibellchambers1290
    @kodibellchambers1290 Жыл бұрын

    Hi, Can these devices be used with the DK DR4088LN devices? IE can it be plugged in via the CAT5e Cat6 Ethernet Cable? I currently have the combo kit from DK.

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    Hello Kodi yes the YD6016LN-CS

  • @ClinchfieldModelRailroad
    @ClinchfieldModelRailroad Жыл бұрын

    So you can set any address to the loconet version, but the connected S88’s are sequential starting at address 17. What if you have a 2nd setup with random addresses on that loconet device, won’t the S88’s also start with an address of 17 and so on ? Won’t there be a conflict of S88 addresses ?

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    You can not over lap addresses no.

  • @karstdrenth

    @karstdrenth

    Жыл бұрын

    yes you CAN address the s88 inputs independantly. but only when controlled by the YD6016LN. ;)

  • @taecart8083
    @taecart8083Ай бұрын

    Is this product on sale

  • @johntavish8750
    @johntavish87509 ай бұрын

    Very interesting. What type of switch would I need if I used two contacts for a turnout, and how would I wire it? Would a SPDT just conected to the two said contacts do the trick?

  • @DCCtrainautomation

    @DCCtrainautomation

    9 ай бұрын

    What type of point motor are you wanting to use?

  • @johntavish8750

    @johntavish8750

    9 ай бұрын

    @@DCCtrainautomation Hi, a mtb mp5. I want to be able to operate the turnout from the z21 app, train controller and a manual switch. I know that if I assign one output to one turnout position and the other position to a 2nd output, then I might have to manually switch twice since moving the turnout on the app or train controller won't physically move the SPDT switch.

  • @DCCtrainautomation

    @DCCtrainautomation

    9 ай бұрын

    @@johntavish8750 then these are perfect!

  • @johntavish8750

    @johntavish8750

    9 ай бұрын

    @@DCCtrainautomation I just recieved two of them, however I have no idea how to wire it to spdt switch for that particular function.

  • @alandance9154
    @alandance9154 Жыл бұрын

    will you do a vid on the YaMoRC YD9401 when thay come in.

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    Yes we will be in next week

  • @alandance9154

    @alandance9154

    Жыл бұрын

    @@DCCtrainautomation great hope youy vid has a bit more info why you should upgrade than the vid from YaMoRC

  • @duncanbirse
    @duncanbirse Жыл бұрын

    Hi James. Thanks for the useful video, however I am failing at the first step. When I plug by YD6016LN into my laptop via USB my computer recognises the device. However, when I open the configuration software it doesn't find the device and just says YD6016 via YDDEMO in the USB properties. I have installed the windows driver from the Yamorc website. I'd be grateful for any suggestions about where I'm goign wrong? Thanks!

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    There could be many reasons for this you plugged in the unit before you load the software and drivers. Would be the main on.

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    Or the USB cable is not good.

  • @duncanbirse

    @duncanbirse

    Жыл бұрын

    @@DCCtrainautomationThanks for your reply. The driver was installed but was saved in the wrong location on my computer. All sorted now and the product is working well. Thanks!

  • @jerryfbarnes5228
    @jerryfbarnes52282 ай бұрын

    Can I use this with JMRI.

  • @DCCtrainautomation

    @DCCtrainautomation

    2 ай бұрын

    Yes if your system has loconet

  • @dallasthomas9298
    @dallasthomas9298 Жыл бұрын

    Hi will these work with z21 white start? If not what would you recommend?

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    Hello no they will not work with z21 White. Sorry. 😞

  • @HumancityJunction
    @HumancityJunction Жыл бұрын

    What is ES Link? Why use ES Link instead of S88N?

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    ES-link is for firmware updating of the unit. You can still use it as S88n

  • @Hal-Zuzzu_Model_Railway
    @Hal-Zuzzu_Model_Railway Жыл бұрын

    So, if I get it right, the only difference between this module and the Digikeijs module is the way to configure them. Operation-wise they are the same, correct?

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    Yes and no. They preform the same function yes. But the small issues that the DK loco net ones had has gone. Also they are all firmware updatable.

  • @Hal-Zuzzu_Model_Railway

    @Hal-Zuzzu_Model_Railway

    Жыл бұрын

    @@DCCtrainautomation I was thinking R-BUS models

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    @@Hal-Zuzzu_Model_Railway these are not R-BUS

  • @Hal-Zuzzu_Model_Railway

    @Hal-Zuzzu_Model_Railway

    Жыл бұрын

    @@DCCtrainautomation Agree, but I was wondering if what I said applies to the R-BUS version!

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    @@Hal-Zuzzu_Model_Railway they don’t plan on doing R-BUS versions

  • @Haymarket47
    @Haymarket47 Жыл бұрын

    Could the loco net version be used with a Z21?

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    If you have the Black Z21 yes you can. You use the L-Bus port

  • @Haymarket47

    @Haymarket47

    Жыл бұрын

    @@DCCtrainautomation That’s good news! Many thanks for response

  • @dereknorth8192
    @dereknorth8192 Жыл бұрын

    can you use these units with digitrax unit

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    Hello Derek yes you can use the 6016LN-CS version yes. It is loconet and we have lots of people very pleased with them Working with Digitrax.

  • @dereknorth8192
    @dereknorth8192 Жыл бұрын

    wy have you not got the new things on your web site.

  • @DCCtrainautomation

    @DCCtrainautomation

    Жыл бұрын

    We have links in the description. But also here www.dcctrainautomation.co.uk/yamorc-yd6016ln-cs-current-sensor.html