Why Brick Masonry Below Plinth Beam?

Ғылым және технология

Is it important to construct Brick Masonry below Plinth Beam? At many locations, brick masonry is provided but do you know what is the reason and basis for its provision. So, In this video, I will discuss and provide complete information about why brick masonry is important under plinth beams...For More details watch this video till the end……"Let’s Learn Something“.
#Plinth #PlinthBeam #PlinthBeamMasonry #Civil Engineering #DrChiragNPatel
1. What is Plinth Beam ? [ प्लीन्थ बीम Beam क्या होता है ? ]
• What is Plinth Beam ? ...
2. Plinth Beam Size and Reinforcement Details [ प्लीन्थ बीम का साइज और स्टील क्या होना चाहिए ? ]
• Standard Provisions fo...
3. Why Masonry Below Plinth Beam ? [ प्लीन्थ बीम के नीचे मिशनरी क्यूं ? ]
• Why Brick Masonry Belo...
4. Plaster on Masonry Below Plinth Beam [ प्लीन्थ बीम के नीचे मिशनरी पर प्लास्टर करना जरुरी है ? ]
• Why Cement Plaster on ...
5. How to Construct Masonry Below Plinth Beam ? [ प्लीन्थ बीम के नीचे मिशनरी कैसे करनी चाहिए ? ]
• How to Construct Mason...
6. Know This Before Plinth Beam Construction [ प्लीन्थ बीम देने से पहेले ये जरूर जानले ]
• How to Construct Plint...
7. PLINTH BEAM // TIE BEAM // What is the Difference Between Plinth Beam and Tie Beam?
• PLINTH BEAM // TIE BEA...
Also, Connect with Us...!!
Join YT: kzread.info/dron/sVj.html...
Facebook: / chiragnpatel. .
Instagram: / drchiragnpatel
For Sponsorship & Business Inquiry...!!
Gmail: drcnpatel.693@gmail.com

Пікірлер: 39

  • @kripalthakur9222
    @kripalthakur92225 күн бұрын

    Bahut hi badiya jankaari. 🙏

  • @fartanmulla364
    @fartanmulla3642 ай бұрын

    Very nice information

  • @bamshankarchoudhary9152
    @bamshankarchoudhary9152 Жыл бұрын

    very nice and informative video,easy to understand important point.Thanks

  • @piyushrvyas
    @piyushrvyas Жыл бұрын

    Next question related to plinth. What is plinth protection? How can we take precautions so that water doesn't "touch" the periphery of the building, and it just flows off, thus there is no water seepage. If we have a plinth beam, is there a need for DPC ? Will the plinth beam act as a DPC ? IF the plinth is a bit lower - say just about 1 ft from internal road level, then is there a need for additional DPC ?

  • @arabindadhar4020
    @arabindadhar40203 ай бұрын

    Many Many thanks for your good instructions. Welcome

  • @m.nafeessiddiqui9238
    @m.nafeessiddiqui9238 Жыл бұрын

    बहुत खूब डाक्टर साहब!

  • @ketantimani2028
    @ketantimani20283 жыл бұрын

    Very nice information sir

  • @DrChiragNPatel

    @DrChiragNPatel

    3 жыл бұрын

    Thanks a lot sir. Keep Watching 🙏🏻

  • @bhaskarbabu655
    @bhaskarbabu6552 жыл бұрын

    very nice information sir

  • @kallepallykrishana5064
    @kallepallykrishana5064 Жыл бұрын

    Good information thankyou

  • @khushiram9807
    @khushiram9807 Жыл бұрын

    Very nice guidance sir

  • @rajivchauhan3223
    @rajivchauhan3223 Жыл бұрын

    Good info👍

  • @TravelBuddy15
    @TravelBuddy15 Жыл бұрын

    Thank you...

  • @apking2720
    @apking27203 ай бұрын

    Placing empty bags of cement between the soil and the plinth beam can cause any damage ? the plinth top level is about 1 feet down from the road level and contractor doing this...plz suggest

  • @aadil8715
    @aadil8715 Жыл бұрын

    Nice video

  • @shaktisehgal9777
    @shaktisehgal9777 Жыл бұрын

    Sir, Can we use stones or AAC blocks in place of bricks in column based house structure and if yes, how and how much more stronger foundation it will become? And is using AAC blocks for full house in Delhi will give more strength and will our house becomes more cool in summers compared to fly ash bricks?

  • @Sukhsatabc
    @Sukhsatabc2 жыл бұрын

    Sir plinth beam v dala hai, door level par v two sariya daal ke concrete ki hai,plinth beam ke neeche v bricks work kiya hai or devar ke dono Corner par beam lagge hai 6-(12mm)ke sariye ke daale hain par fir v devar ke crack a gya hai uska kya karan hai, kya dewar settle huyi hai,sare makan mein 15 beam Dale hai or sabko plinth beam se joda hai or door level par v joda hai, kya iske baad v settlement issue a sakte hai.

  • @vineetsrivastava971
    @vineetsrivastava971 Жыл бұрын

    Kya plinth beam ke upar andar wale pr 4 inch ki diwal chal sakte h,wo soil ka pressure le lega

  • @kaushikraha2893
    @kaushikraha289310 ай бұрын

    Sir mera GL ka beam existing ground level se 1 foot niche hai aur floor level existing ground level se 3 foot upar hai . Yane dono me 4 feet ka antar hai isme dono Beam GL and PL dene se achha hoga ? Please batayen

  • @Mk-uz9uo
    @Mk-uz9uo Жыл бұрын

    Please tell me gap between plinth beam and DPC for plumbing work

  • @kinzaandfizan8393
    @kinzaandfizan83937 ай бұрын

    Sir mera plinth beam road se 1 feet uper he aur outer plenth beam k niche 5 feet 9 inch wall karayi h but inner plenth beam k niche 1 eit lagakar plenth beam dala h...koi problem to nahi hogi?

  • @arora_for_life
    @arora_for_life9 ай бұрын

    मिशनरी और मेस्नोरी में अंतर होता है भाई😂

  • @SumerSingh-ir5bb
    @SumerSingh-ir5bb11 ай бұрын

    Basement ( 6 feet ground level se niche aur 4 feet ground level se upper ) ke liye plinth beam etc kha kha de .pura detail me btaiye .thanks

  • @dilbagsinghsarwara205
    @dilbagsinghsarwara205 Жыл бұрын

    Sir road level se 5 fitt plinth beam dena hai toh 4 fitt brick work shi rhega

  • @debendradeep9518
    @debendradeep95182 жыл бұрын

    20×20 sqft only ground floor ke liye steel size bataye

  • @RohitKumar-se6lz
    @RohitKumar-se6lz Жыл бұрын

    Sir Brick work will start on footing level and road level

  • @ShubhShubh111
    @ShubhShubh111 Жыл бұрын

    नमस्कार सर, हमारा घर 4 मंजिला का है, घर के बेसमेंट की उंचाई 4ft है, जमीन से 4ft के उपर हमने plinth beam दिया है ground beam दिया ही नहीं, और column के लिये जमीन में 5ft गड्डा लिया है, 4 मंजिला घर के लिये ये सब बराबर है की नही ?

  • @GuruRajpoot6633

    @GuruRajpoot6633

    Жыл бұрын

    अब क्या मतलाब पूछने से क्या उसको मिटा कर दोबारा बनाओगे क्या

  • @sumitsanyal4916
    @sumitsanyal49162 жыл бұрын

    Hi Sir, my plinth level from road is 1.5 ft. My site engineer is planning to do pcc of 6 inches and on that plinth beam. Is this the correct process and will there be any issue in future if I don't do brick work below plinth beam ? Thank you.

  • @kartikshekhar940
    @kartikshekhar9402 жыл бұрын

    1. What alternative can be used below Plinth beam apart from red brick ? 2. Can we use AAC blocks below plinth level ? 3. Can CLC Blocks be used below plinth level ? 4. Any other material that can be used in replacement of red brick below plinth ?

  • @parijat95

    @parijat95

    Жыл бұрын

    big size stone peices. in Rajasthan people use stone for underground structure. it is water resistant. bricks below soil will loose strenght as time passes due to water soil and dampness but same is not with stone.

  • @gosports1934
    @gosports1934 Жыл бұрын

    Can I use big stones below plinth beam ??

  • @parijat95

    @parijat95

    Жыл бұрын

    yes stone is best

  • @KALPVastuAstro
    @KALPVastuAstro2 жыл бұрын

    Namaste Sir, pahle red bricks wali wall Banana chahiye ya Bheem Banana chahiye?

  • @kallepallykrishana5064
    @kallepallykrishana5064 Жыл бұрын

    Plinth beam ka neche ACC block use kar sakte hai. plaster jaruri hai . nahi

  • @modassariqbal306
    @modassariqbal3062 жыл бұрын

    Sir, if road is ready and Road s plot slop me hai...aur ground level p shop hai to road s kitna upar plinth height lena hoga.... Aur me n Ground level s 4 inch below plinth beam diya hu....aur us k upar 3 feet 6 inch heights ka bricks work kiya hu...road s 18 inch level lekar.....to kya ye sahe hai...but filling coast morum ka jada jaa rha hai.... Please make 1 video on this sir

  • @DrChiragNPatel

    @DrChiragNPatel

    2 жыл бұрын

    I think your plinth level is 18 inch above road level. If so than it is sufficient

  • @siddikkhan3204
    @siddikkhan32043 жыл бұрын

    .

  • @piyushrvyas
    @piyushrvyas Жыл бұрын

    Brick wall below the plinth beam - on periphery? Brick wall will also merge with soile over years - due to water. Why not have SSM on periphery walls below the plinth beam?