VIESSMANN VITODENS 100 WB1A - Stripping down - Rubber Hoses

Тәжірибелік нұсқаулар және стиль

VIESSMANN VITODENS 100 COMBI BOILER. Stripping down. Looking at the rubber hoses and why they block up.
Why do boilers fail , strip down of Vissmann 100 combi boiler blocked or nearly blocked rubber hoses. Why do hoses block. take out every part. Full strip down of the viessmann 100 combi boiler. cutting up the rubber hoses.

Пікірлер: 28

  • @conanking945
    @conanking9454 жыл бұрын

    This video save me time money and stress. Thank you

  • @metallitech
    @metallitech6 жыл бұрын

    We just got a vitodens installed. Beforehand I ran central heating cleaner in the (hot) system for a couple of weeks. I drained it hot, and then flushed it (not power-flushed). A lot came out!!! And before the flush I noticed that the boiler became quieter.

  • @liljasere
    @liljasere7 жыл бұрын

    awsome video

  • @AllenHart999

    @AllenHart999

    6 жыл бұрын

    liljasere Thank You

  • @morg3058
    @morg30586 жыл бұрын

    It's funny because in Germany they don't even bother with Magnetic filters. The WB1A is an average boiler (with rubber hoses that Vaillant scrapped 10 years ago). They get a bonus point for using stainless steel heat exchangers (embarrassing for Worcester). Everything else is just your usual run of the mill plastic/generic crap. The spare parts price for these are horrendous. Unfortunately UK installers think inhibitor and a magnaclean mean they can ignore good installation. If you want a good boiler the only sensible conclusion is fit Intergas.

  • @ilyaasoow

    @ilyaasoow

    5 жыл бұрын

    Thank you to start with. How come i never heard of intergas boilers before today???!!! When my current boiler dies this is the only boiler i will get. I HATE diverter valves whether it's made plastic, copper or metal, it is most annoying part of all conventional combi boilers.

  • @claudiudane6364
    @claudiudane63642 жыл бұрын

    Hello Sir, Please tell me know what your think about Vitodens 100 W model 2021. I have a choice between viessmann vitodens 100-w 2021 and ariston alteas one. Thank you

  • @duboisjeanfrancois4284
    @duboisjeanfrancois42842 жыл бұрын

    Hello I have a Viessmann boiler with Vitodens 222-W WS2A 35kw tank that is 15 years old. I was told that I can turn the pump to put a larger exchanger. Mine is a BP 10 - 20 plates apparently we can put a bigger one in BP 10? I do not find

  • @paulkramer2599
    @paulkramer25996 жыл бұрын

    Same problem in the Vaillant Ecomax and early ecotec boilers.........I Agree with KB.......Rubber hoses just attract the system crud and also get brittle and in worst cases split under pressure !!

  • @AllenHart999

    @AllenHart999

    6 жыл бұрын

    I am personally not keen with the rubber hoses TBH either. new ones are copper now.

  • @AllenHart999

    @AllenHart999

    6 жыл бұрын

    Thanks for watching.

  • @nassif70
    @nassif705 жыл бұрын

    Question: I am having an issue with my boiler WB1B. I had a power surge few weeks ago which it stops the boiler from operating/turning on. I had to replace "pump control board" due to bad transformer and now the main control board fuse (2.5A) blows every time i connect the fan harness to the board and turn unit on. any idea if its the fan assembly or something else before i start replacing more parts? Thanks Allen.

  • @AllenHart999

    @AllenHart999

    5 жыл бұрын

    You need someone with multi meter knowledge to test the components, Thanks

  • @richardhindmarsh3129
    @richardhindmarsh31297 жыл бұрын

    believe me mate I have seen hoses solid, installers haven't the first clue about system water quality nor do they even seem bothered. Filters (good ones) such as magna clean are essential and anyone who says otherwise is a fool

  • @tarquinbiscuit-barrel5871

    @tarquinbiscuit-barrel5871

    7 жыл бұрын

    I work on Viessmanns on a daily basis, and this level of contamination is very common, and many of these boilers already have either Magnaclean or Fernox TF1 filters fitted. The filters usually have little or very little in them whilst the plate heat exchangers are clogged. Filters are no substitute for thorough flushing.

  • @AllenHart999

    @AllenHart999

    6 жыл бұрын

    The hoses do get blocked but i do find they are great for been able to clean out.

  • @clockworkbike
    @clockworkbike4 жыл бұрын

    I keep getting carbon build up inside the combustion chamber. It clogs the drain and I get water (from combustion) leaking everywhere. Any ideas?

  • @AllenHart999

    @AllenHart999

    4 жыл бұрын

    Have a gas engineer give it a good service and check it out. Thanks.

  • @rwgasservices6764
    @rwgasservices67645 жыл бұрын

    I believe that Viessmann do not like inhibitors in their system.For me a damned good cold mains flush is good enough or certainly should be. We have now fitted 2 050’s Combi boilers And at some stage very soon they will need a strip down service and probably the rubber hoses cleaned out too.

  • @AllenHart999

    @AllenHart999

    5 жыл бұрын

    How did you find the Viessmann Robert?

  • @rwgasservices6764

    @rwgasservices6764

    5 жыл бұрын

    Allen Hart I like them.The 050 is easy to commision and install.I want to try the 100 before too long

  • @AllenHart999

    @AllenHart999

    5 жыл бұрын

    Have you stopped installing Ravenheat?

  • @MrNani71
    @MrNani71 Жыл бұрын

    hát ezt jól szétbarmoltad!....

  • @kb5057
    @kb50576 жыл бұрын

    not flushing obviously and hoses are the biggest problem, like magnets themselves!!

  • @AllenHart999

    @AllenHart999

    6 жыл бұрын

    Such a joy to work on, the rubber hoses are really easy to clean out. Thanks for watching.

  • @AllenHart999
    @AllenHart9996 жыл бұрын

    kzread.info/dash/bejne/iZqKvLidqpjIddo.html

  • @user-yp6fx8ek8i
    @user-yp6fx8ek8i3 жыл бұрын

    OXUENNO

  • @AllenHart999

    @AllenHart999

    3 жыл бұрын

    👍👍👍👍

Келесі