Victron Energy SmartSolar MPPT 100/20

Victron Energy SmartSolar charge controller MPPT 100/20. Unboxing and review.
This is a mega quality solar charger. My favorite brand.
Later in the new video I will record the installation in a river boat.
Victron web page:
www.victronenergy.com/
VictronConnect app:
www.victronenergy.com/support...
Victron SmartSolar charge controllers datasheet:
www.victronenergy.com/upload/...

Пікірлер: 78

  • @VictorVictor-hq7ui
    @VictorVictor-hq7ui Жыл бұрын

    No music please.

  • @stevezb
    @stevezb2 ай бұрын

    What’s the music? I don’t understand what you are saying

  • @TopAdvenTours
    @TopAdvenTours2 жыл бұрын

    It’s really nice product, I used to installed it before. Thanks for sharing

  • @HouseMastersTools
    @HouseMastersTools2 жыл бұрын

    Bravo Majstore , dobro odrađeno 🍻

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    Hvala :)

  • @MatzeMaulwurf
    @MatzeMaulwurf2 жыл бұрын

    I'm using one of those (exact Modell) to charge my Battery in my Camper Van (R/V). I have a standard 330W Peak Module on the roof and this charger charges the main Battery. Very good Charger. Nice App.

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    Everything is great from Victron :)

  • @bexraphaela
    @bexraphaela Жыл бұрын

    I really love this video, it show everything i need to know, thanks 🙏🏼

  • @electro_solar

    @electro_solar

    Жыл бұрын

    Thanks

  • @paulswoodshop395
    @paulswoodshop3952 жыл бұрын

    Nice video. I am going to get some Victron's in the near future.

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    Tnx, yeah Victron products are pure perfection! Just try it :)

  • @Supanova70
    @Supanova70Ай бұрын

    Questtion on this MPPT controller. I hae 2 house to start batteries on my boat. Got to the boat and app said they were floating. Showed 20v from 2 100 watt panels 0 amps. When my boat is running my battery monitor shows -1.59 amp draw? Why? The voltage is 14.8 from motors. Shunt is installed correct to a neg bus bar. All house loads are off during readings. This also has a ACR

  • @electro_solar

    @electro_solar

    Ай бұрын

    Something is taking 1.59 amps for sure. U use victron smart shunt? U can alsoo contact me trough email, find it here on my chanel. I can try to help you.

  • @johnmanatt5829
    @johnmanatt58296 ай бұрын

    I’m using the SmartSolar 100/20 Controller and a 200 w mono solar panel to charge 8 6volt deep gel cell batteries. When I connect all wires I get a yellow light instead of a blue light. Initially when I connect the the last wire it lights up blue until I tighten it in place and the light changes to yellow. What does yellow indicate and shouldn’t the light be blue for a regular charge?

  • @electro_solar

    @electro_solar

    5 ай бұрын

    Hi sorry for my late replay. U can read here all what u need, it is very well explained. Green led - Float, Yellow led - Absorption and Blue led - Bulk. community.victronenergy.com/questions/63640/charging-bulk-absorption-and-float.html

  • @igorkvachun3572
    @igorkvachun35722 жыл бұрын

    Yes👍 ⚡🔌💡🔋

  • @abelramos8983
    @abelramos89832 жыл бұрын

    Hi there! can you use one of this with a no hybrid (regular on grid) inverter? Thanks

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    Yes you can

  • @adassociates8235
    @adassociates82352 жыл бұрын

    Will it be hook up to same system with Renogy DC DC charger? As the Renogy won’t be able to run solar panels in series/parallel. Thanks

  • @electro_solar

    @electro_solar

    Жыл бұрын

    U can connect it.

  • @sketcheddraftingdesign6093
    @sketcheddraftingdesign60932 жыл бұрын

    What is the largest size cable that would fit into the battery and PV terminals ? Would 8 B&S fit ?

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    I'm not 100% sure but I think it can be 8

  • @daves543

    @daves543

    9 ай бұрын

    I just installed two 100-20's on two different campers and used 10 gauge wire to go from the solar panel to the Victron and between the Victron and the battery . The stranded 10 gauge wire won't fit in the4 terminals even when twisted really tight. I used a 10 to 12 gauge reducer crimped onto the 10 gauge wire and it fit good.

  • @photog1529
    @photog15298 ай бұрын

    What size wire are you using at the Victron battery connections? I have the same controller, and when I used ferrules on 10AWG stranded wire the ferrules wouldn't fit into the Victron. In my opinion, the terminals on the Victron are pretty anemic.

  • @electro_solar

    @electro_solar

    8 ай бұрын

    I use 10 awg. Terminals are great. Its rated for max 10 awg. Try to use rounded crimp tool for awg 10.

  • @davebruessow6842

    @davebruessow6842

    Ай бұрын

    10 gauge CCA will not fit without breaking strands (making it sloppy). If you use pure copper (THHN or PV wire) it will be smaller in diameter and you can even "tin" the ends with solder making an even stronger connection...

  • @alexanderstrelow3521
    @alexanderstrelow3521 Жыл бұрын

    Hi and thank you for the video. I am willing to buy this charge controller for my two Solar panals to charge a 12v battery. My panels do have 550 watts each and in series they will have ~80v at ~18 ampre. My question is: how much watt of my 1150 max will I be able to youse charging a 12v? Does this only run at 290 watts or can I use everything that is being currently producee?

  • @electro_solar

    @electro_solar

    Жыл бұрын

    You can use full power. Charge more batteries. If i understand your question correctly?

  • @alexanderstrelow3521

    @alexanderstrelow3521

    Жыл бұрын

    @@electro_solar Hi, thanks for your reply. After some research I will maybe use 2 12v batteries to have a 24v system. As per manual maximum watt allowed is 580 I think. Since my system will not have more than the 100/20 I just want to make sure that even if 580 watts are exceeded (1100 In theory...) It will just block at 580 and will not burn or something :D I could also use just one panel to make sure but if there is less sun having a higher peak power is quite nice.

  • @FandFcustomcarts

    @FandFcustomcarts

    Жыл бұрын

    The highest watts is for a 48v battery set up

  • @juanpabloolivachipolina
    @juanpabloolivachipolina Жыл бұрын

    Hello; I have an E-essential Flat 130 Watts Inovtech Monocrystalline solar panel, and a Power Battery 12v 130 ah slow discharge Battery Lead Calcium Technology. Can you please tell me which Victron regulator model would fit, for this setup. Thank you.

  • @electro_solar

    @electro_solar

    Жыл бұрын

    Hi, u can use SmartSolar MPPT 75/15 from Victron. www.victronenergy.com/solar-charge-controllers/smartsolar-mppt-75-10-75-15-100-15-100-20

  • @juanpabloolivachipolina

    @juanpabloolivachipolina

    Жыл бұрын

    Merci

  • @mstgnckmega8019
    @mstgnckmega80192 жыл бұрын

    Hi, thanks for video. Can i monitoring it from over internet away from home? Or only near the device from bluetooth!!!

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    Yes, you can track data in a lot of ways... www.victronenergy.com/panel-systems-remote-monitoring

  • @myresonance8013
    @myresonance80132 жыл бұрын

    Would I be able to run x2 160watt panels with the 100/20 brother ?!??

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    Yes u can, u have alsoo their calculator and data sheet for every product.

  • @myresonance8013

    @myresonance8013

    2 жыл бұрын

    @@electro_solar Awesome thankyou 👌

  • @UKvet246
    @UKvet2462 жыл бұрын

    Hi is there a way to wire this so it charges leisure battery and the vehicle battery

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    Of course, the options are limitless :)

  • @UKvet246

    @UKvet246

    2 жыл бұрын

    @@electro_solar how

  • @UKvet246

    @UKvet246

    2 жыл бұрын

    At the moment I've used the load positive to the starter battery, is that the correct way

  • @ZokiG
    @ZokiG11 ай бұрын

    Pozdrav. Imam jedno pitanje. Sa elektronikom nisam baš na ti. Imam Allpowers SP033 200W prenosni solarni panel. Njegove specifikacije su: Open circuit voltage 22,2V, Short circuit current 12A, Power voltage 18V, Power curent 11A. Je li mi za punjenje 12V 100ah lifepo4 akumulatora treba ovaj 100/20A mptt kontroler ili mogu uzeti i njihov mptt 75/15A?

  • @electro_solar

    @electro_solar

    11 ай бұрын

    Pozdrav, 75/15 regulator podrzava po njihovim specifikacijama panel do 220W tako da bez problema se moze spojiti taj panel na 75/15 blue solar ili smart solar.

  • @ZokiG

    @ZokiG

    11 ай бұрын

    @@electro_solar hvala na odgovru. Planoram uzeti smart solar zbog mogućnosti spajanja preko BT

  • @electro_solar

    @electro_solar

    11 ай бұрын

    Najbolji izbor za male sisteme. Nema na cemu.

  • @user-dj1xv7bz6v
    @user-dj1xv7bz6v Жыл бұрын

    Klass

  • @robertbraham5487
    @robertbraham5487 Жыл бұрын

    Mppt 1oo 20 victron

  • @TIMALFA56
    @TIMALFA562 жыл бұрын

    Kad ce novi video

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    Zbog posla nisam stigao nista. Nadam se i ja da ce biti uskoro :)

  • @bc69006900
    @bc690069004 ай бұрын

    No music please and that was a lead battery you connected too

  • @electro_solar

    @electro_solar

    4 ай бұрын

    Yeah just for testing. Now its mounted on river boat with lifepo4.

  • @HansKeesom
    @HansKeesom10 ай бұрын

    Yep this is the goto MPPT for me. It can do 12/24/48 volt batteries and is the largest that has it's own load port. Wicked. That it is Victron speaks for itself, no other brand in my systems ;-)

  • @electro_solar

    @electro_solar

    10 ай бұрын

    Yeah, best for me

  • @mjokser5365
    @mjokser53652 жыл бұрын

    Hm..., poznat mi ovaj uvod 😁

  • @electro_solar

    @electro_solar

    2 жыл бұрын

    Zna se tko me nagovorio na taj hehe

  • @mjokser5365

    @mjokser5365

    2 жыл бұрын

    @@electro_solar Nisam ni sumnjao 😁😁

  • @jeancayer3360
    @jeancayer33607 күн бұрын

    Why do you need to put music ? The subject is interesting enough...

  • @electro_solar

    @electro_solar

    7 күн бұрын

    @@jeancayer3360 I was new to all of this.

  • @arshal5106
    @arshal51064 ай бұрын

    I am here to watch your video on specific item and there was your background music. I am not interested your junk music. Please show and explain about the item only.

  • @electro_solar

    @electro_solar

    4 ай бұрын

    Thanks for the comment, there is no need to spread hatred, you could have said it differently. At that time just started with youtube, still learning, have a nice day.

  • @littleowltelevision1418
    @littleowltelevision14183 ай бұрын

    Absolutely terrible , music totally annoying!!!!!

  • @electro_solar

    @electro_solar

    3 ай бұрын

    I was new to yt, no experience. Thanks for comment.

  • @DavidArroyo78
    @DavidArroyo78Ай бұрын

    Terrible music choice

  • @electro_solar

    @electro_solar

    Ай бұрын

    @@DavidArroyo78 Ok, tnx. I was new to all of this.

  • @DavidArroyo78

    @DavidArroyo78

    Ай бұрын

    @@electro_solar you are good sir. I apologize for coming off harsh with my comment. Thanks for sharing your video. 👍🏼

  • @electro_solar

    @electro_solar

    Ай бұрын

    @@DavidArroyo78 Thanks for being polite in today's modern world. I am currently unable to record new content. when I am able, I will try to correct all the mistakes.

  • @DavidArroyo78

    @DavidArroyo78

    Ай бұрын

    @@electro_solar you be you! You make your videos however you like. Who cares what others think.

  • @electro_solar

    @electro_solar

    Ай бұрын

    @@DavidArroyo78 tnx

  • @kvp5233
    @kvp5233 Жыл бұрын

    Добрый день Здравствуйте вы можете подсказать почему вот эти три лампочки моргают В чём причина спасибо если ответите

  • @electro_solar

    @electro_solar

    Жыл бұрын

    You can find error codes here on page 35 www.victronenergy.com/upload/documents/Manual_SmartSolar_MPPT_75-10_up_to_100-20/MPPT_solar_charger_manual-en.pdf

  • @electro_solar

    @electro_solar

    Жыл бұрын

    It can be: - charger temperature too high - charger over-current - charger or panel over-voltage - VE.Smart networking or BMS issue - internal error, calibration issue, settings data lost or current sensor issue

  • @kvp5233
    @kvp5233 Жыл бұрын

    Здравствуйте

  • @electro_solar

    @electro_solar

    Жыл бұрын

    Hello :D