True DIY install on Mini Split Air Conditioner through MiniSplit Surplus Save $1500 on HVAC Install

Confortotal USA Mini Split Install 12000 btu 110v 1 ton Ductless Heating & Cooling
These systems have 4 modes FAN, DEHUMIDIFIER, AC, HEAT
We warranty DIY you can order directly from our site
minisplitsupplyhouse.com

Пікірлер: 54

  • @jessevasquez8323
    @jessevasquez83232 ай бұрын

    Awesome video. I talked to Maegan on phone and she walked me through on setting the remote control and converting the Celsius to Fahrenheit in a couple of easy steps she was very professional and I would advice anyone to call their supply house for any questions. Highly Recommendations. Thanks Maegan!

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    We’re always here to help 🙂

  • @jjmonty8090
    @jjmonty809021 күн бұрын

    Good video…love the views of both sides. Easiest video to understand from all I’ve watched. From what I know you aren’t supposed to crank down really tight on the flare fitting because you will crack them. This is true for the vacuum pump too because there is a plastic o ring that gets hyper compressed and ruined if tightened too much. Also the coils need to be coiled horizontally as to not allow a build up of oil in the loops. Great vid

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    11 күн бұрын

    Glad it was helpful, the oil trap has been disproved by engineers, I don’t have the link available now but I will look for it. We coil the excess lines vertically with no issues.

  • @jjmonty8090

    @jjmonty8090

    11 күн бұрын

    @@MiniSplitSupplyHouse Awesome! Thanks for the update!

  • @petrobull2560
    @petrobull2560Ай бұрын

    Great video!👍

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    Thank you!

  • @prepsolar787
    @prepsolar7873 ай бұрын

    awesome i just went and check your store going to order two from you soon

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    2 ай бұрын

    Awesome! Thanks for checking us out! We’ll see you soon, we offer Free Delivery when you’re ready and know what you need let us know and we’ll bring it to you!

  • @huntergcarswell
    @huntergcarswell2 ай бұрын

    This was amazing

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    2 ай бұрын

    🙏

  • @Blammoification
    @Blammoification3 ай бұрын

    thank you

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    2 ай бұрын

    You're welcome!

  • @caru3257
    @caru3257Ай бұрын

    I washed a mini split coil where the homeowner had run the equipment when a renovation had takennplace. What a nightmare.

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    We always discourage installing before the space is complete! The horrors we’ve seen from careless installs or people not understanding the equipment the way we’ve dedicated ourselves to is haunting 😥

  • @redneckpackrat
    @redneckpackratАй бұрын

    Excellent video. Thanks. Only one question, for clarification.... did you start the unit BEFORE you released the refrigerant? Wouldn't that build up an awful amount of head pressure in it, or is this a more-sophisticated compressor than the old 1990s dinosaurs using R22 that I've monkeyed with in the past?

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    We do make sure they power up before we release the refrigerant into the system, you can call Dustin 480-338-6197 for a better explanation on why we do this 🙂

  • @redneckpackrat

    @redneckpackrat

    Ай бұрын

    @@MiniSplitSupplyHouse I did just that earlier this evening, and Dustin did an excellent job of describing his process and reasoning for it. I'll be doing it that way when my adapter shows up and I can evacuate the lines and evaporator! Sure wish I'd come across this vid before making my purchase, it'd've definitely been made through y'all if at all possible!

  • @fredturner1767
    @fredturner1767Ай бұрын

    Great Video! I am considering installing one of these in an RV. I was trying to see on the video, is it possible to run the lines and drain tube out the side of the head unit instead of the back as long as the drain tube is at an downward angle? I would like to run the lines inside the coach and out through the floor to the compressor which would be mounted on a stand in front of the trailer. The lines would run under the trailer and thus not seen until they come up to the compressor.

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    Yes you can I’m trying to share a picture but it only wants to let me upload a video you’re welcome to text me and I can send you some photos 573-410-2769

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    These kits come with 12’ lines

  • @MiniSplitSupplyHouse
    @MiniSplitSupplyHouseАй бұрын

    Hello, this video was made July 2022 we’ve learned a lot since then, pulling a vacuum like this is not a true leak test! We do require our customers follow this step to clear the indoor unit and lines of any air, moisture, potential contaminants that can affect the outdoor unit. You can always reach out if you have additional questions 480-338-6197 Dustin 573-410-2769 Megan MINI SPLIT SUPPLY ROLLA MISSOURI

  • @ChrisSpencer-mr1he
    @ChrisSpencer-mr1heАй бұрын

    Thinking about purchasing two of these and wondering what outside temp will it work down to in winter weather and still heat inside? Thanks

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    We’ve found they will still produce heat at negative temperatures, they lose their BTU output the colder it gets so we size for the heat load at cold temps not the AC

  • @SetitesTechAdventures
    @SetitesTechAdventuresАй бұрын

    So this unit gets power from a plug indoors instead of outdoors? Is that the case for the NG too?

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    The Confortotal is indoor only the NG is not like that, it is opposite power at the compressor only via disconnect

  • @jtheadturner
    @jtheadturnerАй бұрын

    Do you have any videos on the comfortotal 220v installation?

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    We do not the install process is the same for all Confortotal unless you have a F MODEL 24000 those are designed to have outdoor power 480-388-6197 Dustin for tech support

  • @platinumf2505
    @platinumf25052 ай бұрын

    I have a confortotal that won’t cool was freezing and another one that blows cool but not cold. Been trying to get the contractor that installed them to come out for months. Would you say it’s probably Freon leak

  • @meganrunyon4498

    @meganrunyon4498

    2 ай бұрын

    Yes that’s been our experience. 9 times out of 10 it is a Freon leak with the issues you’ve mentioned. what state are you located in?

  • @ernestwilson5591
    @ernestwilson55912 ай бұрын

    One thing I missed or it wasn't shown in your video your head unit had a power cord attached? Did you attach that, or did it come with that? Now I am confused, I just bought an Everwell mini split (very similar to the one in your video) and the electrical cover on the condenser has two holes in for power/signal cables, so I was assuming that I had to have an electrician to hook me up some outside power for the condenser unit. It is a 110v system, the handbook that came with it is worthless, that is why I have been watching so many you tube videos. Can someone help with this? Thanks.

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    2 ай бұрын

    Hi Ernest, I’m glad you found us. This unit comes with the power cord from the air handler that’s why people call them “DIY” Your Everwell most likely needs power at the compressor - Megan Mini Split Supply 573-410-2769

  • @ernestwilson5591

    @ernestwilson5591

    2 ай бұрын

    @@MiniSplitSupplyHouse Hi Megan, thanks so much for help.

  • @caseymacgill3428
    @caseymacgill3428Ай бұрын

    Do you have a unit that I can plug into the inside outlet that has a longer line set? I would like to do a second floor installation.

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    Hi Casey all Confortotal come with 12’ Lineset kits, when you need longer lines we recommend getting them from a supply house. The units are Precharged up to 25’ if you plan to go longer it is most likely you’ll need it charged for the added length for optimal performance.

  • @caseymacgill3428

    @caseymacgill3428

    Ай бұрын

    @@MiniSplitSupplyHouse Can you recommend a place for me to order a 30 ft line?

  • @riddecp.2224
    @riddecp.222414 күн бұрын

    Is this unit powered inside through the header (wall plug)? Sorry, looking for an option where I have a full circuit breaker already.

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    11 күн бұрын

    Yes it is, no exterior power is needed. We have higher efficiency units available that require the disconnect at the outdoor only minisplitsupplyhouse.com/collections/ngtrade-mini-splits

  • @crescobar124
    @crescobar124Ай бұрын

    I have a question... I installed one in my house and I followed all the steps in the manual and the video as well and my compressor only turned on for a few minutes and the fan only turned on when I put it in fan mode. Do you know why is that happening

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    There could be many reasons What is the temperature set at, try turning it all the way down in AC mode and letting it run If it is at temp it will not think it needs to kick on

  • @fredrenfro7710
    @fredrenfro771016 күн бұрын

    The entire system, head unit and compressor is powered by the inside 120 V wire?

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    11 күн бұрын

    Yes

  • @Bryan.Nguyen
    @Bryan.NguyenАй бұрын

    Do you know how many seers is this unit?

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    Ай бұрын

    12/13 SEER All systems imported from Mexico that use indoor power only are low seer systems

  • @rojeliom2389
    @rojeliom23892 ай бұрын

    Where's the fuse located?

  • @davidhankins5708

    @davidhankins5708

    2 ай бұрын

    No fuse. IT is a 110 volt plug in unit. Inside handler plugs into wall outlet and provides power to outside compressor.

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    2 ай бұрын

    David is right! If your local codes require a disconnect you can feed the power cord out with the Lineset and wire it that way

  • @johnjackson224
    @johnjackson22418 күн бұрын

    Does anyone have that brackets (inside one) dimensions or an install template?

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    17 күн бұрын

    These kits do not come with an indoor template that’s why we measure to get the accurate placement for the hole

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    17 күн бұрын

    I (Megan) will see about getting the dimensions for you

  • @sarentopi1502
    @sarentopi150213 күн бұрын

    This is an invalid training video. It doesn't show pressure test prior to vacuum. Sustaining vacuum does not guarantee a tiny leak is not present.

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    11 күн бұрын

    You’re right, we made a comment clarifying that this is not a true leak test, this is a good enough vacuum to clear the lines for us to guarantee your warranty when you shop direct with us 🙂

  • @shitzUnotz
    @shitzUnotz2 ай бұрын

    This 110V confortotal systems is designed to be wired to a quick disconnect outside by the compressor, right? I noticed you used a plug-in cord that looked like it was connected to the head unit. I don't want that I just need to make sure that is not how this system works before I buy it.

  • @MiniSplitSupplyHouse

    @MiniSplitSupplyHouse

    2 ай бұрын

    It is not designed to wire into a disconnect, it’s only power source is that gray extension from the air handler that’s why these are considered “DIY” We do offer the style of unit you’re asking about the brand is NG minisplitsupplyhouse.com 5 year warranty direct by us

Келесі