Troubleshooting low voltage shorts

On this video we are looking into a method of troubleshooting low voltage shorts. This equipment is a residential 208-230 volt single phase gas/ac package unit with an ecobee 5 thermostat.

Пікірлер: 23

  • @stephenacman3244
    @stephenacman32448 күн бұрын

    ME TO BROTHER, I ONLY CARRY 5 AMP FUSES AS WELL!! 24 yr exp tech from Va. Love your videos, nice work.

  • @seadeas
    @seadeas5 ай бұрын

    Good job talking people through this, explaining and showing.., Thanks 🙏

  • @andreeriner811
    @andreeriner811 Жыл бұрын

    I’m with you on using 5 amp fuses. Good vidio, I just had one with an intermittent short it would go about a day I hate those its so much easier when it’s a dead short. I had a bad contractor coil and I pretty much felt like that’s what it was when I went out. Lol, I didn’t take the time to ohm out that coil so it cost me having to go back. I knew better that’s one of those live and learn moments. Good vidio thanks.

  • @enriquechavezjr9594
    @enriquechavezjr95942 жыл бұрын

    Thanks for the vid learning slowly but surely.

  • @ronniehvac653
    @ronniehvac653 Жыл бұрын

    Just found your channel and subscribed. I'm in upstate NY about 2 hrs north of NYC. thanks for the info

  • @fermin0614
    @fermin06144 ай бұрын

    What a good explanation thanks 🙏

  • @wesleywaldrop476
    @wesleywaldrop4762 жыл бұрын

    Thanks for the content.

  • @Niegocki28
    @Niegocki28 Жыл бұрын

    Great video

  • @pablocarpio664
    @pablocarpio664 Жыл бұрын

    Cool video man

  • @PBS-nm1uu
    @PBS-nm1uu2 жыл бұрын

    great presentation, please do one on sequence of operation, thanks

  • @marvinsellers4457
    @marvinsellers4457 Жыл бұрын

    Hey Hoss I be doing this since 01 I am licensed but you know every one has different way to do things you know opinions are like arm pits I’m very thankful for what you I’m 65 and still learning mom always if you point your finger you have pointing back at you just saying

  • @jackbrennan8476
    @jackbrennan84768 ай бұрын

    Good video

  • @gods959
    @gods95911 ай бұрын

    New Subscriber just because 👍❤️🙏 Blessing

  • @buckyoufiden2187
    @buckyoufiden2187 Жыл бұрын

    thanks, you know your stuff. i will subscribe and check out your other videos. thanks again for taking the time to help others.You're awesome!

  • @dustinhopper1184
    @dustinhopper11842 ай бұрын

    My fuse will last a month or two. So its hard to find the short and is intermittently happening.

  • @anthonys6187
    @anthonys61875 ай бұрын

    So do you just use a 5 amp popper fuse as well for trouble shooting or do you carry both 3 and 5 for testing purposes?

  • @AIRMANHVAC

    @AIRMANHVAC

    5 ай бұрын

    I haven’t had good results using a popper….transformers getting burnt up. I keep a big box of 5 amps only. No issues using just 5’s.

  • @elvinrodrguez5
    @elvinrodrguez5Ай бұрын

    Can you explain Why Fuse Pops when I connect the Y’s to the furnace control board? Like I can’t power Outdoor unit with 24v because it pops

  • @AIRMANHVAC

    @AIRMANHVAC

    Ай бұрын

    There must be a short of some kind in your wiring or the contactor in the condensing unit.

  • @RW-to2fy
    @RW-to2fy7 ай бұрын

    One problem is the wifi thermostat today time

  • @alvarolucio8264
    @alvarolucio82643 ай бұрын

    Boa Noite sou daqui do Brasil a parte do aquecimento corre risco pra fazer brasagem na tubulação com o tubo perto de gás?

  • @pitbulllife4198
    @pitbulllife41984 ай бұрын

    The case why wouldn't you sell them a surge protector