Пікірлер: 141

  • @duaneafields
    @duaneafields Жыл бұрын

    Very helpful!! 3 ptacs in my home, got rid our our ducting, best thing we ever did (put sleeves in the three main areas of our home), our master bedroom ptac went out 2 days ago, august 103 degrees S. georgia. just took the capacitor out of another bedroom ptac and ours is fixed now. I switched them. btw the other bedroom ptac now does the same thing, so it was the cap. Wife very happy, we'll see tonight! So here[s what it was doing.. on high or low cool, about every minute or so, there was a slight buzz for about 5 seconds, then stops till another minute rolls around, compressor was very hot to the touch, really hot. the fan always ran as normal just no ac. so the cap fixed it. and the compressor was fine all along and we're happy now. cleaned the whole thing too ge digital ptac. thanks for your video.

  • @hemant25787
    @hemant257872 жыл бұрын

    Thank you so much for all the video

  • @DharmeshPatel-rz3hd
    @DharmeshPatel-rz3hd2 жыл бұрын

    Awesome you are a big help 😎

  • @dlcgaming894
    @dlcgaming8943 жыл бұрын

    Thanks for showing me :)

  • @timhopper7148
    @timhopper7148 Жыл бұрын

    Any tricks for islandaire I can’t get the compressor to start in my work shop by putting it local and y and r if I ad g everything starts normal

  • @brandonbentonsr.2620
    @brandonbentonsr.2620 Жыл бұрын

    Can you upload a vid how to pair the remote switch back to the unit after resetting it manually

  • @Bootsiegirl17
    @Bootsiegirl178 күн бұрын

    Hey Dave. I have an Amana PTAC unit installed in 2007. What are the chances of finding a main board to replace one that's not working now?

  • @DanielCardenas-mr8gs
    @DanielCardenas-mr8gs3 жыл бұрын

    What’s up David, I’m starting my first Hvac job in the field with just about a year of only book/school experience. The company mainly works on Ptac units, any tips for my first day to show my employer that I’m easily trainable and tips I should know about ptac units that I can share with him on my first day? Your feedback would be very much appreciated and I’ve been watching all your videos and they’ve already helped me to have a basic understanding of ptac units already. Again thanks David!

  • @PtacSolutions

    @PtacSolutions

    3 жыл бұрын

    Hello, Thank you for watching my videos... I would just recommend to make sure everything is working properly, never assume anything. Make sure coils are clean, and a general inspection of each unit you work on.

  • @DanielCardenas-mr8gs

    @DanielCardenas-mr8gs

    3 жыл бұрын

    @@PtacSolutions thanks David, very much appreciated for the advice!

  • @hellraidersnationwithbigbr1565
    @hellraidersnationwithbigbr1565Ай бұрын

    What about a H5 code on a Garrison P-Tac in. Heat mode??

  • @paullambert1485
    @paullambert1485 Жыл бұрын

    Hey Mr Dave great info thanks I have a question I'm working at a hotel and I'm finding some Amana PTAC units with no over load or pressure switches what is that all about is it that someone took out the over load switch or what could that be I can s send u some pics if u want

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hey Paul Yeah send some pictures, let me take a look

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Davidcardenas@airight.net

  • @Jeff6742Cp
    @Jeff6742Cp Жыл бұрын

    How's it going David. My PTAC Amana A/C works fine and fan. But when I turn on the heat, I hear clicking and the fan just constantly blows and the heat won't turn on. I held down the up and down button, pressed the heat button twice, and let it run in A/C and Heat mode. Everything seemed to work fine. Both the A/C and Heat worked and then it turned off as yours did. But when I turn on heat and put the temperature all the way up to 90, the heat just will never turn on. I double clicked cool and hit "Fan speed" like you said and got to the Set Point option. Everything read similar to yours did but when it showed "I C" for indoor coil, it just showed "1." And then "77". Does that mean 177 degrees or something different? What seems to be the problem and how do I go about fixing it? Thanks man.

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hello Jeff The Amana units come with a factory preset of 80° anything above that won't work. Try setting your heater to 80 or lower wait the 3 to 5 minute delay, to see if that works

  • @NikoTheDad
    @NikoTheDad8 ай бұрын

    What a badass

  • @gabrieljefferson2591
    @gabrieljefferson2591 Жыл бұрын

    I cleaned my unit with a hose. Now when I plug it in there's no light except when I press reset, the plug blinks green then seemingly switches back of like a safety trigger. It hasn't been 24 hours yet, but near.

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hey Gabriel Sounds like you may have gotten water in the power cord or any electric components. Just let it dry for a few hours and then retry

  • @user-wu2ec2yr9m
    @user-wu2ec2yr9m Жыл бұрын

    I turn my unit on cool to a low 60 degree and it starts off great. Kicks out cold air. Runs about 2 mins and then the capacitor kicks off for a minute or two which causes warm outside air to blow in and then the capacitor kicks back on and a minute of cool air returns but only for a minute until the cool/warm cycle continues. Would that be an old faulty capacitor issue? Or do I need a refrigerant recharge?

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hello, Check if you have a broken fan blade or if the outdoor motor( condenser motor) is working

  • @jeannieramirez9405
    @jeannieramirez9405 Жыл бұрын

    Hi Mr David I purchased a Tpac Centry Comfort air last yr and it didn't come with a remote ,and heater works great but a/c when it's 90"degrees outside it turns off every 15 mins and it keeps showing E9 what does that mean???? Please help

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hello E9 Code is usually a broken fan blade, bad condenser motor or dirty condenser coil. Check out this video: kzread.info2JP2VFQB0pk?feature=share

  • @rollzolo
    @rollzolo2 жыл бұрын

    What brand do you recommend a wall ac from home depot or Lowe's? I want to replace a Friedrich wallmaster. Seems like reviews are hit and miss with all brands. I regret tossing out an old one during remodeling. Seems like new one have issues out of the box or lucky to last five years. Also the sleeves on the wall is 17 ×27..should I insert the new model with a new sleeve in the existing sleeve? Thanks for your time. May the Most High bless you brother.

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Yeah, they don't make them like they used to. Honestly, I haven't tried any of those ac but I have heard good from the ac at home depot. I would recommend to replace that sleeve, due to the air ways, but if there isn't much difference and the old sleeve looks in good shape you can leave it. Thanks for watching!!

  • @Iharry69

    @Iharry69

    2 жыл бұрын

    Pop

  • @EOhh-88

    @EOhh-88

    3 ай бұрын

    I can't get my ptac to blow out air/heat. .. the fan doesn't turn on, can I do anything to try to make it work besides buying another one? I'm not able to do that right now

  • @hugohernandez8783
    @hugohernandez87833 жыл бұрын

    Good job ¡¡¡ what does the words one my ptac "hp " mean one the dashboard??

  • @PtacSolutions

    @PtacSolutions

    3 жыл бұрын

    Hello, its basically sensing that the room is too hot... maybe it could be reading air from the outside coming in, check gaskets around the unit . That code should go away when temperature falls

  • @paullambert1485
    @paullambert14852 жыл бұрын

    Hey Mr Dave got a question I have this Ptac unit when it goes off it blows the filter cover off what could that be it also makes a loud noise when it happens

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hey Paul I would take the unit out of the sleeve, let it run for a few minutes and turn it off to see why it's doing that... check for loose parts

  • @jonahboy6388
    @jonahboy63882 жыл бұрын

    Hello David I really need your help I work a lot a hotel where they have lots of these type of ac’s and several of them are not turning the indoor fan on so they don’t blow cold air, is there a way I can turn them on or it’d be better to bring an electric to check them? Thanks in advance!

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hello, I would check to see if the control board is sending power to the motor by checking it from line 1 to either high speed or low speed( depending on what you have it set on)

  • @jonahboy6388

    @jonahboy6388

    2 жыл бұрын

    @@PtacSolutions thanks for replying and ok I’ll try to do that David thanks again

  • @paullambert1485
    @paullambert14852 жыл бұрын

    Thanks for the info I have a question I have amana ptac unit when I put it on it never shuts off I can put the temp up to 85 on cool and it keeps running would that be the control board?

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hey Paul How are you. Thank you much... Question: Is it only the blower motor that keeps working or is it the whole cooling system?

  • @monsieurlaphant603

    @monsieurlaphant603

    2 жыл бұрын

    It's the cooling unit for me. Set to 73 cooling but only blows somewhat cool air but not what it used to. Green light is on during that time. From what I've described, can you figure out a solution 🤔

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    @@monsieurlaphant603 Hello, the green light means there's a error code.. can you check to see what that code is

  • @khalilsanoubar5124
    @khalilsanoubar5124 Жыл бұрын

    👍🏼

  • @paullambert1485
    @paullambert1485 Жыл бұрын

    Hey Mr Dave hope all is well I have a ptac that the heat comes on for a couple minutes then it blows cold then back to heat what could it be

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hey Paul Do you have any airflow restrictions like dirty coil or blocking at the discharge area. That could be setting off the limit switches

  • @sbigballin
    @sbigballin7 ай бұрын

    Hey love the video but I can not get my system to turn on or have any lights come on....I have the green light on on my end of my plug that's it....can u help?? Thanks

  • @PtacSolutions

    @PtacSolutions

    7 ай бұрын

    Hello Sorry for the late reply, it sounds like a bad board. Its pretty common

  • @donp6914
    @donp69142 жыл бұрын

    I have a general electric PTAC unit model number AZ61HO7DADM2 and I can't control the fan it won't switch from high low to auto seems to be stuck in low everything else works great can you help?? there is no absolutely no control over the fan like the button doesn't work

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hey Don I would check the blower capacitor. I have also seen that if the blower wheel is really dirty it prevents it from picking up enough air, there for it seems like its always running on low speed. Let me know

  • @melvinsimmons9909
    @melvinsimmons99096 ай бұрын

    My model is a TC153G35AXXXBA. I am getting 242 Volts at the outlet

  • @PtacSolutions

    @PtacSolutions

    6 ай бұрын

    Ok, so you do have the right voltage. Check the transformer(loose wires, burnt transformer) if possible I would even replace it

  • @paullambert1485
    @paullambert1485 Жыл бұрын

    Hey mister Dave looking to start my own repairing and cleaning PTAC units I'm getting ready to go around to the hotels in my area maybe you can give me some hints on how to start my business I would appreciate it I'm getting ready to retire next year and I want to get into doing something a couple days a week and making some extra money

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hey Paul That's good to hear. Well, the way I started is printing business cards and handing them out to as many hotels as I could. Always be persistent. I had to do some free work from time to time to get owners to trust that I knew what I was doing. It was a slow process, but eventually it picked up.

  • @paullambert1485

    @paullambert1485

    Жыл бұрын

    @@PtacSolutions Thanks Dave I was a into the floor covering business for almost 40 years believe me I've done my share of free stuff but to me it wasn't a job it was just something I did to make a living I kind of enjoy it because I always seen the end result and that was satisfying to me .Thanks again for the info have a great day.

  • @geoffreyyoung5419
    @geoffreyyoung5419 Жыл бұрын

    So having an older Ptac unit with a dial thermostat and selector switch is their way to troubleshoot this board thanks Geoff it is a Trane unit

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hey Geoff I'm not to familiar with that specific unit... but check line 1 and line 2 if you are getting power, check the 24v., also check for burnt marks around or under the board

  • @geoffreyyoung5419

    @geoffreyyoung5419

    Жыл бұрын

    @@PtacSolutions Thanks

  • @dannyclubb4309
    @dannyclubb43092 жыл бұрын

    I have a brand new one that was installed and it won't blow cold. I can hear the compressor turn on but wont get cold.. and suggestions?

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hey Danny If everything is running more than likely is out of refrigerant.. is it a Amana ptac?

  • @hall87668
    @hall876682 ай бұрын

    I sprayed the outside of my PTAC with a hose and the unit stopped working what do you think the issue is? It's totally unresponsive I've checked the voltage at the wall and at the transformer

  • @PtacSolutions

    @PtacSolutions

    2 ай бұрын

    Hello Maybe you got some water into one of the electronics, give it some time to dry and try again

  • @Isaack123
    @Isaack1232 жыл бұрын

    Im In NYC, Do you know someone that can fix my Freidrich Ptac?

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hey Isaac No, but try calling their customer service line they might have techs around your area

  • @tomwooten7206
    @tomwooten72062 жыл бұрын

    I have the same unit. Ac works great when using heater, blower fan will not come on. I can smell and feel heat from the coils but no fan. Any suggestions?

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hey Tom If you have it on auto usually it tends to run on low speed, depending on the room temperature, anyway try turning on the heat and put the blower on high speed and lets see what it does... could be that the low speed relay on the board maybe starting to fail.

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Is the unit a heat pump?

  • @tomwooten7206

    @tomwooten7206

    2 жыл бұрын

    It is not a heat pump. It is a apt size combo just like in the video. It works great on ac side hi, low but no fan when you turn heat on

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    @@tomwooten7206 ok, then sounds like you may have a problem with the board

  • @tomwooten7206

    @tomwooten7206

    2 жыл бұрын

    Wonder if that part is available, if so would you know where to get it?

  • @downer8015
    @downer80159 ай бұрын

    I keep getting a LC code error on a distinction unit but I've literally cleaned the coils and filters and it's still stuck on that code. Any tricks on what I can do ??

  • @PtacSolutions

    @PtacSolutions

    9 ай бұрын

    Hello, Maybe you have a faulty outdoor coil thermistor

  • @downer8015

    @downer8015

    9 ай бұрын

    @@PtacSolutions appreciate it

  • @user-it5qr6mq7s
    @user-it5qr6mq7s11 ай бұрын

    What is the d,5meam or who to clear or fix code

  • @PtacSolutions

    @PtacSolutions

    11 ай бұрын

    Hello It means the outdoor DC motor lost connection with the variable speed board. Check for loose or burnt wires. If not your going to have to change the motor and board

  • @elinsoncanales6634
    @elinsoncanales6634 Жыл бұрын

    I'm getting a d4 and d5 code do you know what is the solution ? I was reading the code manual but they don't appear there

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hey Elinson Those code are usually a variable speed terminal board or the high efficiency motor(outdoor or indoor). I would recommend to replace both since it's a little completed to troubleshoot

  • @elinsoncanales6634

    @elinsoncanales6634

    Жыл бұрын

    @@PtacSolutions Thank you so much !

  • @manuelmarcial2303
    @manuelmarcial23032 жыл бұрын

    My ptac show me 4 dashes on the display ( ==) can you help me please.

  • @ismaeldominguez7806

    @ismaeldominguez7806

    2 жыл бұрын

    please help us David Car. we have this error same.

  • @fpwhisel
    @fpwhisel3 жыл бұрын

    Are these tricks are working on any brand of PTAC ? Is it standard on almost every PTAC unit ? Also i have 3 LG PTAC that someone gave to me and they all having the same problem. When you push on the fan, nothing happen. You can hear 2 click (relays i suppose) but nothing is mooving. Didn't have any error code. Do i have to go into a diagnosis menu to see it ? Thanks in advance.

  • @PtacSolutions

    @PtacSolutions

    3 жыл бұрын

    Hello, these tricks will only work for the Amana ptac units... as for the LG units I have ran across a lot of them with a bad blower motor

  • @andrade24100
    @andrade241003 жыл бұрын

    I'm getting a C7 code. Could you show us how to fix

  • @PtacSolutions

    @PtacSolutions

    3 жыл бұрын

    kzread.info/dash/bejne/iGSBrbmmd6nbfaw.html That's usually a indoor coil thermistor

  • @mohammadhanif1564

    @mohammadhanif1564

    3 жыл бұрын

    @@PtacSolutions hi I have a question my Amana p tech unit on display green light blinking unit not going on Please reply me ASAP thanks My email address mhanif736@gmail .com

  • @PtacSolutions

    @PtacSolutions

    3 жыл бұрын

    @@mohammadhanif1564 is the ac unit not working at all?

  • @bluestory26
    @bluestory262 жыл бұрын

    Hello David, I have four dashes on my ac ,and I can't go to remote programing mode. Can you help please?

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hello, are those four dashes on all the time or only when you are trying to program the unit?

  • @bluestory26

    @bluestory26

    2 жыл бұрын

    @@PtacSolutions only when I am trying to go to program mode. Otherwise the unit is working fine.

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    @@bluestory26 ok I have gotten those before where I'm trying to program but it won't let me.. unfortunately you are going to have to replace the control board

  • @bluestory26

    @bluestory26

    2 жыл бұрын

    @@PtacSolutions I fixed with the help of Amana Reset PTAC security code 1. Switch off AC 2. Turn [MASTER SWITCH] off 3. Press and hold [FAN SPEED] button. 4. While keep [FAN SPEED] button down, turn on the [MASTER SWITCH] 5. Count slowly to at least 10 6. While fan button is down, press and release [COOL] button. 7. Release the fan button. 8. Wait a bit and try to enter REMOTE mode.

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    @@bluestory26 thanks a lot for that info!!

  • @eddiefaison2621
    @eddiefaison2621 Жыл бұрын

    What does it mean when you're constant fan light is on and where it says high low or auto light is on can't turn it off only way to turn it off is unplug it

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hello Eddie You may have to turn off the setting manually, like this kzread.info/dash/bejne/Y3arytSaerSclLA.html

  • @eddiefaison2621

    @eddiefaison2621

    Жыл бұрын

    It didn't work

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    @@eddiefaison2621 ok, you may have a problem with touch pad. Do you have access to any other unit?

  • @eddiefaison2621

    @eddiefaison2621

    Жыл бұрын

    No someone post to come out tomorrow it's just really hot in here tonight

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    @@eddiefaison2621 oh wow, sorry to hear that... really hope they can take care of that for you

  • @bigjohnny6245
    @bigjohnny62453 жыл бұрын

    My unit is reading a Eo what does that mean?

  • @PtacSolutions

    @PtacSolutions

    3 жыл бұрын

    That means it needs to be programmed to either- cooler only or heat pump.... to do so go to the settings( press and hold plus and minus, while holding press off twice) you should see to lines, go C3 by navigating with the heat button. While in C3 navigate with plus button to set either heat pump or cooler only

  • @marciagrant6687
    @marciagrant66872 жыл бұрын

    My mini split is not turning on. I already unplugged the device and plugged it back in and turned off and on the power from the fuse box. How do you reset the device?

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hey Marcia Question-- is there a green light on the power cord?

  • @marciagrant6687

    @marciagrant6687

    2 жыл бұрын

    @@PtacSolutions Hi there! There is a light, but it is not on. I see a reset button and a test button on the side of the power cord.

  • @marciagrant6687

    @marciagrant6687

    2 жыл бұрын

    I pressed both buttons. I got a br and a F1 on the display. And the light on the power cord turned green.

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    @@marciagrant6687 is there a way you can check how much power is coming into the unit from line 1 to line 2?

  • @marciagrant6687

    @marciagrant6687

    2 жыл бұрын

    @@PtacSolutions I will have to contact Statewide remodeling. They placed it.

  • @claudettecarmichael9005
    @claudettecarmichael90052 жыл бұрын

    How do I disconnect the unit from the thermostat

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hello Claudette Do you know how to get into the settings?

  • @alanmason2383
    @alanmason23839 ай бұрын

    Got a question about a PTC unit ...

  • @PtacSolutions

    @PtacSolutions

    9 ай бұрын

    What's going on

  • @devonsandner5362
    @devonsandner5362 Жыл бұрын

    I run the diagnostics and get no codes. Still no heat

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hello Devon Can check for continuity from the two heater wires connected at the control board?

  • @soccer22kestay57
    @soccer22kestay572 жыл бұрын

    Br code how do you fix that

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hello, Try this and let me know if this helped kzread.info/dash/bejne/eWqusbZ6qK3dY7Q.html

  • @melvinsimmons9909
    @melvinsimmons99096 ай бұрын

    How fo I clear my high voltage code on Ptac

  • @PtacSolutions

    @PtacSolutions

    6 ай бұрын

    Can you tell me the model number of the unit and how much power is coming out of the outlet, that usually happens when your unit is not made for the building voltage

  • @PtacSolutions

    @PtacSolutions

    6 ай бұрын

    For example The unit would be for a 230/208v. and your power supply is 265v

  • @melvinsimmons9909

    @melvinsimmons9909

    6 ай бұрын

    I have tried everything. Changed parts. Still nothing is fixing the unit. Not powering on. Thank you

  • @caroljean1708
    @caroljean1708 Жыл бұрын

    Unit is plugged in but no green or red light on panel

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hey Carol Do you have a green light on the power cord?

  • @raymondmcclendon5206
    @raymondmcclendon52068 ай бұрын

    Why can't I change my temperature settings

  • @PtacSolutions

    @PtacSolutions

    7 ай бұрын

    Hello, Try resetting the unit and try again

  • @CcC-qc8en
    @CcC-qc8en2 жыл бұрын

    Hi! My ptac is giving me an error code of d4 but I can't find error code any where. Just wondering if anybody knows.

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hello What brand name is the unit?

  • @user-it5qr6mq7s

    @user-it5qr6mq7s

    11 ай бұрын

    Ananon

  • @user-it5qr6mq7s

    @user-it5qr6mq7s

    11 ай бұрын

    Amana

  • @barbitasdeoro4095
    @barbitasdeoro40952 жыл бұрын

    Cómo se quita ese foquito verde

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hola, que tal... ese foco prende cuando hay un código.

  • @barbitasdeoro4095

    @barbitasdeoro4095

    2 жыл бұрын

    @@PtacSolutions ok muchas gracias yo creo es la resistencia se quemó

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    @@barbitasdeoro4095 Que código salio?

  • @PeaceSAAAN
    @PeaceSAAAN2 жыл бұрын

    My PTAC unit won’t turn off, the fan will always stay on

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hello Peace Is it an Amana ptac?

  • @nicklopez5774
    @nicklopez5774 Жыл бұрын

    Have you ever seen error code d4 d5

  • @PtacSolutions

    @PtacSolutions

    Жыл бұрын

    Hey Nick Yes that's usually the high efficiency motor(indoor or outdoor)or the variable speed board. I usually replace both

  • @shamarr81
    @shamarr812 жыл бұрын

    HELLO I have a question what if the PTAC HAVE A WEIRD SMELL 👃🏼 CAN THEY GIVE OUT Carpet monoxide poisoning

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hello, Did the the smell start when you turned on the heater?

  • @dorapacheco2438
    @dorapacheco24382 жыл бұрын

    My just flashing

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hello Dora Is it two lines flashing?

  • @derwoodgreene253
    @derwoodgreene2532 жыл бұрын

    Code d6

  • @PtacSolutions

    @PtacSolutions

    2 жыл бұрын

    Hey Derwood That would be a indoor DC motor problem. Check the connections from that DC motor to the small board inside the electrical compartment., if that's good more than likely you'll have to change out that motor and board

  • @1meancyberbully329
    @1meancyberbully329 Жыл бұрын

    Non worked