Absolutely amazing that there are still such high quality air conditioning manufacturers like Trane that can build a TXV equipped system that can last 5 whole years before it fails and needs a repair. Just like A coils that total replacement cost as much as half the price of a new unit depending on where you live, like here where our local repairmen charge over $150 per hour labor and 10 to 20 times their cost of the refrigerant and about 200 to 300 percent markup on parts. Give me a standard old fixed orifice unit any day. But I guess I can cry about that all day just like the fact that they don't sell R 22 new units anymore either. But I think I'd like to move to South Carolina just so I can get this guy to charge me a fair price for quality work...either that or Steve Lav's town. Then again, I'd have to move to upstate New York to get my cars worked on by South Main Auto youtuber too, man I'd be movin all over the place just to not get screwed.
@maximusaircompanycuppbaile3273 жыл бұрын
I was at work one day and called you you answered I know you couldn't talk but wow it made me feel so good your a very nice person you don't know how much you do for people like fixing the dryer vent your an HVAC legend in the KZread word your my helper in the field I need to know something I can't go to you Thur your videos thank you Mr cook
@TedCookHVAC
3 жыл бұрын
Any time!
@TheWoodman0645 жыл бұрын
Your videos are tops with my 13 year old grandson! He loves watching with me!
@TedCookHVAC
5 жыл бұрын
Thank You very much for the support !! I really appreciate you watching !! What is his name ? I will give him a shout-out.
@englishruraldoggynerd
5 жыл бұрын
Brilliant... your giving him something precious ~ your time, attention, and love so many young people never know ~ and of course instilling in him confidence, giving him education in electronic things and showing him that university education isn’t necessarily the best way forward for all professions, but highly desirable if that’s what he chooses. You sound like a sound bloke Elwood :)
@sknight03915 жыл бұрын
That's one of the best tech.'s you've had in awhile Ted. Give the man insurance and 401k and see if he'll stick around 👍
@jaybee1930
2 жыл бұрын
He looks like that Geico gecko
@MrMultitool5 жыл бұрын
Glad o see someone else using MAPP gas in an attic. It does a Great job .Jimmy is better than some of the help I've had for sure.
@oddjobz98582 жыл бұрын
Man you are a gentleman and a good technician. I like your style and your videos keep up the good vibes
@Rick-rz1gm5 жыл бұрын
I have always loved this, TXV valve, thermostatic expansion valve valve🤣 . Good video.
@bairfamilyfarm1336
5 жыл бұрын
It's like "PIN number"! Personal Identification Number number.
@djastram5 жыл бұрын
You're kinda the Bob Ross of HVAC it seems. Nice video!
@tommyt5815
4 жыл бұрын
David Jastram what does that mean ? He’s a painter ? Seriosly I’m confused
@picklerix6162
4 жыл бұрын
Bob Ross didn’t mind helicopters.
@Im-not-clever5 жыл бұрын
And here i go thinking you actually got a new helper, i should've known better hahahaa
@BangBang-fj5tv5 жыл бұрын
Lol freaked out when jimmy the lizard jumped on top of the fan
@picklerix6162
4 жыл бұрын
Bang Bang - Apparently, that was not Jimmy’s first rodeo, running across the fan grate.
@jimgill57064 жыл бұрын
Good work and very informative. The only suggestion I have would be to use Stay-Brite8 on the liquid line joint.
@drifter4365 жыл бұрын
I did a change out today and put a XR in. Nice units.
@Chris-wp3ew4 жыл бұрын
bought a couple of those Nebo LED lights you recommended. Very compact and will come in handy!
@jamescook75885 жыл бұрын
Love the videos, keep them coming.
@lee-johnson5 жыл бұрын
Great helper and he can get you good rates on car & motorcycle insurance!
@kevinbennett25655 жыл бұрын
@7:13 awww he's gonna help us....NO JIMMY NO!!!!! Crazy ass Jimmy hahaha
@chrissteene5 жыл бұрын
this is what happens when you are a good guy and treat customers rite they will alowyes want you over any one else because you are the best at what you do
@renecuevas41283 жыл бұрын
We have a lot of Jimmy s here in s Fl. Love ur shoes also and since I m almost retired after 30 summer s of doing AC I enjoy the way u figure stuff,,,,,,we use renew here since day one they figure the sticky txv oil issue We replace so many till the right stuff was added. Yup Jimmy enjoy to see a guy that knows his trade.....ttul. learning and re learning we never get tire ,,,,,,rise my kids doing it.....caiou
@jayva325 жыл бұрын
Those helpers are seasonal, awesome in the summer but cant get them to even leave their house in the winter.
@thebluelunarmonkey
5 жыл бұрын
and always leaving a tail behind in the weirdest places
@lengthluther4845 жыл бұрын
Jimmy really likes the hot air coming out of the unit!!!!
@sitanhuang9402
5 жыл бұрын
Cold-blooded
@jaydee26202 жыл бұрын
Obviously Jimmy the lizard knows that system inside and out. Good thing he was there to double check ur work. Yeah I know it sucks servicing units far away, being a good person and Doing the right thing can be a hassle sometimes. But you will sleep good at night
@AMStationEngineer5 жыл бұрын
I'd have had to ask if the homeowner's property was insured thru Geico...
@Sctronic2095 жыл бұрын
Lots of good info 👍👍👍
@lancerudy99344 жыл бұрын
Always like your videos. Keep then commim
@gtrdrejugfde2884 жыл бұрын
Great video I use supco88 oil addictive it works good. Give it I try. Back in the good old days there where no micron gauges just pull a good vac with the valve cores in place and we road with it. The units ran for many years. 🥱
@jmccord07164 жыл бұрын
good video. ya got me when the smoke detector went off though thought mine was going off for some reason lol
@BenTh175 жыл бұрын
Jimmy the lizard is working on his EPA certification
@johnsmithjr54985 жыл бұрын
Could have left the door off and put a wet rag on the valve to prevent a future problem. jmo. Your helper pays attention better than a lot of them!!
@CSHayes5 жыл бұрын
Give Jimmy a big bonus
@hounddoggzgaming69705 жыл бұрын
I luv these videos
@richardheyne22352 жыл бұрын
The more I watch. I'm thinking about going to school for it
@icicleVR155 жыл бұрын
Top notch Mr. Ted
@marklabelle73714 жыл бұрын
Keep these videos Coming!
@MasterTheNEC4 жыл бұрын
I sure wish you were near McKinney TX.....We have a TRANE and has never worked since the day it was installed in 2016.
@dragsterstransmissions4 жыл бұрын
I was just thinking back to when we had our system replaced. The TXV was bad from the start and it had to be replaced. Three years later it had to be replaced again. It's a puron system Recently the big line frosted and I thought here we go again. I cleaned the condenser coil and the A coil (as best as I could still mounted in handler). It needed it. Also cleaned the fan. Seems to be good now it's been a few weeks. Small line is warm the big line is cold and the fan is pumping out slightly warm air
@dpky73332 жыл бұрын
Talks about that lizard the way Bob Ross would talk about a tree.
@yettielusive33705 жыл бұрын
I like that little lizard guy...funny that he wants to be an hvac helper. lol
@necroticagony9355 жыл бұрын
Glad you never did XB units. Glad Trane got out of the entry level units and left them to Goodman.
@OldePhart4 жыл бұрын
I would have liked to hear the commentary during the txv install.
@donnierobertson30885 жыл бұрын
Good job
@sknight03915 жыл бұрын
Good Job Jimmy 🦎
@TheWoodman0645 жыл бұрын
Thank you! His name is Joseph and my name is Woody! We really do appreciate and enjoy your videos! B.l.t.n!
@rolandodelapaz39703 жыл бұрын
Good job sir
@hg2.3 жыл бұрын
Using a doctor analogy, if most of your service calls are sprained ankles, this is brain surgery. We viewers wouldn't mind watching the whole operation at regular speed - I'd like to see every step. But it points to another "genre" I need to study up on. Thanks for making.
@JosephArata5 жыл бұрын
Anything under 102 PSI suction pressure with 410a in a residential system, will cause a condensation freeze over on the evaporator coil 99% of the time.
@Oto_Travel
4 жыл бұрын
Only a pro would of figured that out
@josephbailey39685 жыл бұрын
Would have liked to have seen the valve replacement at regular speed, otherwise, a great video.
@scottk06234 жыл бұрын
That was the Geico Gecko trying to sell them A/C service insurance.
@robertgregory26184 жыл бұрын
Jimmy was the name you gave the mouse that died on an outside condenser in one of your previous vids.
@Mike-yh8tv5 жыл бұрын
Thanks for your expertise...learn much form your videos!
@RyanKajtor3 жыл бұрын
The bob ross of hvac
@Sctronic2095 жыл бұрын
He better stay out of the fan blade
@Ravagedsoul19882 жыл бұрын
least it isn't like 30 degrees out. Those days suck when it's raining, cold and having to pull a vacuum.
@RG_sssSMOKING5 жыл бұрын
Thanks Ted
@HanZie823 жыл бұрын
So amazing to see how drains and electrical wire is just there. Here in my country( the Netherlands) that would so not be allowed. Also it looks ugly hehehe. Love your video's, brings back hope that there are actual people willing to put in the (educated) work!
@airmechanical71635 жыл бұрын
Jimmy is undercover youtube police.
@joekerr86345 жыл бұрын
Great video, my only question, if you knew you were going that far out why the heck didn’t you bring the big guns for the evac?
@lengthluther4845 жыл бұрын
I actually have a lizard named jimmy too. My girlfriend really likes to play with him.
@marklabelle7371
4 жыл бұрын
LMAO
@throttlebottle59065 жыл бұрын
something similar to jeopardy music, very fast polka or bluegrass would have been great at the sped up part :))
@mychoclabwinston4 жыл бұрын
2 wrenches, I like this guy already, 1 wrench guys drives me nuts. Watched many of techs try to undo a black iron union with 1 pipe wrench, Me...... woahhhhhh, use to wrenches, there is a reason, and you hand isn’t a wrench
@billsimpson6044 жыл бұрын
'Jimmy' lives in that immediate area, watching out for cats & hawks, with a metal shelter and some water from sweating metal fittings in the hot weather.
@MacMcCabe24563 жыл бұрын
It's a bit hard to here you talking. Love your videos......
@SparkeyDogfish4 жыл бұрын
I used to service telecommunications equipment. Troubleshooting is the same process for most stuff. So I would be interested in having you explain the gauge readings for the non hvac guy.
@hg2.
3 жыл бұрын
Ted does HVAC 102, not HVAC 101. There are lots of guys who do HVAC 101. Try Greyfurnaceman, Ty Branaman, or Word Of Advice channels, to name a few.
@treymanning86335 жыл бұрын
I pull vacuum with the appion 3/8" hoses down to 350 microns in less than 8 minutes.
@marklabelle7371
4 жыл бұрын
Trey Manning is that system vacuum or is that with a pump running?
@lawnmoose4 жыл бұрын
Using a hand held acetylene tank is mint. I guess it only works on 3/8" copper, anything larger would need more heat. What type of silfoss is that, seems low temp also.
@bmorekairful5 жыл бұрын
App ion core removers rated for 20 microns. Evacuate system in minutes.
@rayvoorhies71805 жыл бұрын
Ted you didn't bring a fishing pole?😉 You could have caught dinner while waiting for that 500 number.
@JamesSamples4 жыл бұрын
LOL, People are helicopters, however the lizard that was sent to spy is a "Buddy" & a "Friend"... Homeowner played this one smart!
@549BR3 жыл бұрын
Doesn't Jimmy have a HVAC technician assistant certificate from Spartanburg Tech College? I told the woman that I'd put it in but couldn't service it, and here I am servicing it. Sounds about right. lol 😎
@tomburson57333 жыл бұрын
I’ve had great luck installing the additive, shifting the reversing valve and letting the unit run awhile in both directions and not having toif
@tomburson5733
3 жыл бұрын
Change the valve
@United_HVAC_and_Fans5 жыл бұрын
Cool.
@rpfree4 жыл бұрын
Jimmy makes me laugh.
@mekyleavacadogaming73545 жыл бұрын
Good video!
@clintglasgow56335 жыл бұрын
👍
@hg2.3 жыл бұрын
Min 13:30 Is that a pre-mixed can of ox-acetylene? That's pretty slick! Beats hauling around those 2 tanks, and hoses, and nozzles...
@ogie51944 жыл бұрын
Man. I'd be pissed, if one of my guys set there tools on the customer washer. Big no, no. I do like watching your videos.
@robbrantley69424 жыл бұрын
was that MAP gas and a 15% silver rod? I know MAP gas and Stay Bright # 8 works well, just curious? Love the videos!!!
@geezus12013 жыл бұрын
Another subscriber made a good comment about they must be insured by Geico bc their gecko is hanging around. 😂
@TheGgin5 жыл бұрын
Nice replacement on the TXV, BTW, how did you get that celebrity "gecko" on your channel? You must be getting famous! :-)
@robbygraves7395 жыл бұрын
What type of solder do you use. I noticed you used map gas to braze. Does that work on bigger suction lines as well? I just some stay bright #8 to try out.
@throttlebottle5906
5 жыл бұрын
mapp gas brazing is likely best on 3/8th or smaller, indoor and no wind or air blowing (no fans), obviously not near any valves or anything that doesn't like extended heating times
@christopherscott88533 жыл бұрын
I thought Jimmy was toast when he ran across the outdoor fan blade.
@robh19085 жыл бұрын
When I saw the thumbnail I thought Roy was still alive.
@nathanbelden82695 жыл бұрын
Hey Ted what is that oil treatment you use?
@rtoweprojects90725 жыл бұрын
Great working conditions don't know why you wouldn't want to service them. If it's a little further from your radius service area just charge more travel time.
@octaviomartinez75352 жыл бұрын
I connect a CPS micron gauge to the system when I vacuum n it usually gives a lower reading than my fieldpiece digital manifold
@dwarden34 жыл бұрын
I keep a fishing pole in my truck for just such an occasion.
@oldhandyluke
4 жыл бұрын
Great idea!
@mychoclabwinston4 жыл бұрын
Not sure that I’d ever use map gas for brazing though,
@christopherwasmuth3678
4 жыл бұрын
It works, not sure id ever braze that with out something on the txv though 🤔
@jakelowe3526
3 жыл бұрын
It is nice to be able to hold it at any angle tho
@OleRazzleDazzler
3 жыл бұрын
Lol the longer I watch teds videos I scratch my head. But he’s a lovable guy. He does things a special way. Yeah, some things aren’t practical . But that’s why it helps old guys and young bloods working together and teaching each other stuff
@OleRazzleDazzler
3 жыл бұрын
Hey, if you don’t bubble flare joints, you’re asking for it. Such a risk taker .
@111000100101001
3 жыл бұрын
If used on small lines, like liquid with little heat sinking, you can knock it out if you’re proficient. The TXVs are pretty tolerant, if you don’t jack around and keep pouring heat into them. Yes, not ideal, but it works; ‘put it to bed and move on.’
@bradfordgordon65524 жыл бұрын
My SMAN 3 gauges had a leak around the sight glass. The rubber gasket pulls in when you pull a vacuum on those. I took my sight glass out and sealed the gasket with the clear refrigeration sealer and tighten the brass ring. This is the problem with the sight glass gauges.
@Elfnetdesigns4 жыл бұрын
Oh an anole, very common in the south USA.
@kevinlogan23065 жыл бұрын
How long do you wait after adding Ac renew I usually leave it at least a day
@Mrflash2220065 жыл бұрын
Jimmy is alright, he’s just chill’in
@Kevin-ib4gv4 жыл бұрын
Great videos but I need to chime in on the evac. Something totally wrong there, even if going through your manifold. I just did 60 feet of 3/8 and 7/8 and had it down to 250 microns in exactly 15 minutes and another 15 minutes to 160 microns, through my Titan manifold and Robinair 5 cfm two stage pump. I pull the schrader cores and use a 3/8 vac hose to the manifold which helps a lot. I would suspect your pump is bad and suggest connecting the micron gauge directly to it and see if you pull down to under 250 and how long it takes to get there. My pump with fresh oil gets to 16 (no typo) microns in less than 1 minute.
@Cuzzy420
3 жыл бұрын
Hahahahah my guy had way to much damn time on his hands cringe.
@mdovideo14145 жыл бұрын
You use map gas to braze the copper line set?
@HVACOG5 жыл бұрын
Hey Ted, I'm always paranoid when I braze next to the TXV and I always use thermal paste. Is it not necessary? Those gaskets don't melt?
@shawnbologna8281
4 жыл бұрын
Don't really need thermo paste just a wet rag wrapped around the txv and it's only 3/8 " copper...if u are good with ur touching it should only take 10 or 15 seconds to make that solder joint, then quickly turn off ur acetylene and use just the oxygen from ur torches to slowly cool the joint
@ramonestrada38
3 жыл бұрын
@@shawnbologna8281 Good point. Of all my years brazing copper joint's I never thought about cooling the the joints with oxygen. I would always just let it cool down and at some point spray it with water or nothing at all. Good tip. Thk u
@geoffhoweth5 жыл бұрын
Tell that Lizard to stay out of your contactors and caps 😊
@animalcorvair
5 жыл бұрын
an fan
@bboyette10175 жыл бұрын
You should do a video of how to retrofit a r-22 system to a R-410a system
@BenTh17
5 жыл бұрын
Brandon Boyette You can’t put 410a in an existing R22 system, you’d have to replace the indoor and outdoor equipment. They do make some R22 replacements though, some require POE oil to be added to the system.
@sitanhuang9402
5 жыл бұрын
U can't, replace indoors and outdoors
@bboyette1017
4 жыл бұрын
@@BenTh17 my hvac instructor is a dumbass then
@anthonygonzalez74885 жыл бұрын
Does that field piece model of guage set always flicker ? It looks like it could be hard to watch.
@thebluelunarmonkey
5 жыл бұрын
No it won't. LCD displays flicker, but too fast for the human eye to perceive, but a video camera grabs images 30 or 60 times a second, so it can detect the LCD refreshing.
@yepper11654 жыл бұрын
Top Jimmy. You a Van Halen fan?😁
@mekyleavacadogaming73545 жыл бұрын
How are you liking the fieldpiece
@9to5techs5 жыл бұрын
I was wondering did you replace filter dryer off camera or you don't have to do that when replaceing a txv. Thanks.
@joshl.158
5 жыл бұрын
R H drier may be internal to the unit so if he pumped it down then he wouldn’t change it.
@sitanhuang9402
5 жыл бұрын
He should, if drier was slightly blocked
@shawnbologna8281
4 жыл бұрын
Should always change the dryer anytime the system is opened
@mychoclabwinston4 жыл бұрын
Changed one on a Bryant the other day, of course everything on the txv was brazed, when will manufactures learn about ease of service, not lugging tools and torches into a crawl space.
Пікірлер: 206
Absolutely amazing that there are still such high quality air conditioning manufacturers like Trane that can build a TXV equipped system that can last 5 whole years before it fails and needs a repair. Just like A coils that total replacement cost as much as half the price of a new unit depending on where you live, like here where our local repairmen charge over $150 per hour labor and 10 to 20 times their cost of the refrigerant and about 200 to 300 percent markup on parts. Give me a standard old fixed orifice unit any day. But I guess I can cry about that all day just like the fact that they don't sell R 22 new units anymore either. But I think I'd like to move to South Carolina just so I can get this guy to charge me a fair price for quality work...either that or Steve Lav's town. Then again, I'd have to move to upstate New York to get my cars worked on by South Main Auto youtuber too, man I'd be movin all over the place just to not get screwed.
I was at work one day and called you you answered I know you couldn't talk but wow it made me feel so good your a very nice person you don't know how much you do for people like fixing the dryer vent your an HVAC legend in the KZread word your my helper in the field I need to know something I can't go to you Thur your videos thank you Mr cook
@TedCookHVAC
3 жыл бұрын
Any time!
Your videos are tops with my 13 year old grandson! He loves watching with me!
@TedCookHVAC
5 жыл бұрын
Thank You very much for the support !! I really appreciate you watching !! What is his name ? I will give him a shout-out.
@englishruraldoggynerd
5 жыл бұрын
Brilliant... your giving him something precious ~ your time, attention, and love so many young people never know ~ and of course instilling in him confidence, giving him education in electronic things and showing him that university education isn’t necessarily the best way forward for all professions, but highly desirable if that’s what he chooses. You sound like a sound bloke Elwood :)
That's one of the best tech.'s you've had in awhile Ted. Give the man insurance and 401k and see if he'll stick around 👍
@jaybee1930
2 жыл бұрын
He looks like that Geico gecko
Glad o see someone else using MAPP gas in an attic. It does a Great job .Jimmy is better than some of the help I've had for sure.
Man you are a gentleman and a good technician. I like your style and your videos keep up the good vibes
I have always loved this, TXV valve, thermostatic expansion valve valve🤣 . Good video.
@bairfamilyfarm1336
5 жыл бұрын
It's like "PIN number"! Personal Identification Number number.
You're kinda the Bob Ross of HVAC it seems. Nice video!
@tommyt5815
4 жыл бұрын
David Jastram what does that mean ? He’s a painter ? Seriosly I’m confused
@picklerix6162
4 жыл бұрын
Bob Ross didn’t mind helicopters.
And here i go thinking you actually got a new helper, i should've known better hahahaa
Lol freaked out when jimmy the lizard jumped on top of the fan
@picklerix6162
4 жыл бұрын
Bang Bang - Apparently, that was not Jimmy’s first rodeo, running across the fan grate.
Good work and very informative. The only suggestion I have would be to use Stay-Brite8 on the liquid line joint.
I did a change out today and put a XR in. Nice units.
bought a couple of those Nebo LED lights you recommended. Very compact and will come in handy!
Love the videos, keep them coming.
Great helper and he can get you good rates on car & motorcycle insurance!
@7:13 awww he's gonna help us....NO JIMMY NO!!!!! Crazy ass Jimmy hahaha
this is what happens when you are a good guy and treat customers rite they will alowyes want you over any one else because you are the best at what you do
We have a lot of Jimmy s here in s Fl. Love ur shoes also and since I m almost retired after 30 summer s of doing AC I enjoy the way u figure stuff,,,,,,we use renew here since day one they figure the sticky txv oil issue We replace so many till the right stuff was added. Yup Jimmy enjoy to see a guy that knows his trade.....ttul. learning and re learning we never get tire ,,,,,,rise my kids doing it.....caiou
Those helpers are seasonal, awesome in the summer but cant get them to even leave their house in the winter.
@thebluelunarmonkey
5 жыл бұрын
and always leaving a tail behind in the weirdest places
Jimmy really likes the hot air coming out of the unit!!!!
@sitanhuang9402
5 жыл бұрын
Cold-blooded
Obviously Jimmy the lizard knows that system inside and out. Good thing he was there to double check ur work. Yeah I know it sucks servicing units far away, being a good person and Doing the right thing can be a hassle sometimes. But you will sleep good at night
I'd have had to ask if the homeowner's property was insured thru Geico...
Lots of good info 👍👍👍
Always like your videos. Keep then commim
Great video I use supco88 oil addictive it works good. Give it I try. Back in the good old days there where no micron gauges just pull a good vac with the valve cores in place and we road with it. The units ran for many years. 🥱
good video. ya got me when the smoke detector went off though thought mine was going off for some reason lol
Jimmy the lizard is working on his EPA certification
Could have left the door off and put a wet rag on the valve to prevent a future problem. jmo. Your helper pays attention better than a lot of them!!
Give Jimmy a big bonus
I luv these videos
The more I watch. I'm thinking about going to school for it
Top notch Mr. Ted
Keep these videos Coming!
I sure wish you were near McKinney TX.....We have a TRANE and has never worked since the day it was installed in 2016.
I was just thinking back to when we had our system replaced. The TXV was bad from the start and it had to be replaced. Three years later it had to be replaced again. It's a puron system Recently the big line frosted and I thought here we go again. I cleaned the condenser coil and the A coil (as best as I could still mounted in handler). It needed it. Also cleaned the fan. Seems to be good now it's been a few weeks. Small line is warm the big line is cold and the fan is pumping out slightly warm air
Talks about that lizard the way Bob Ross would talk about a tree.
I like that little lizard guy...funny that he wants to be an hvac helper. lol
Glad you never did XB units. Glad Trane got out of the entry level units and left them to Goodman.
I would have liked to hear the commentary during the txv install.
Good job
Good Job Jimmy 🦎
Thank you! His name is Joseph and my name is Woody! We really do appreciate and enjoy your videos! B.l.t.n!
Good job sir
Using a doctor analogy, if most of your service calls are sprained ankles, this is brain surgery. We viewers wouldn't mind watching the whole operation at regular speed - I'd like to see every step. But it points to another "genre" I need to study up on. Thanks for making.
Anything under 102 PSI suction pressure with 410a in a residential system, will cause a condensation freeze over on the evaporator coil 99% of the time.
@Oto_Travel
4 жыл бұрын
Only a pro would of figured that out
Would have liked to have seen the valve replacement at regular speed, otherwise, a great video.
That was the Geico Gecko trying to sell them A/C service insurance.
Jimmy was the name you gave the mouse that died on an outside condenser in one of your previous vids.
Thanks for your expertise...learn much form your videos!
The bob ross of hvac
He better stay out of the fan blade
least it isn't like 30 degrees out. Those days suck when it's raining, cold and having to pull a vacuum.
Thanks Ted
So amazing to see how drains and electrical wire is just there. Here in my country( the Netherlands) that would so not be allowed. Also it looks ugly hehehe. Love your video's, brings back hope that there are actual people willing to put in the (educated) work!
Jimmy is undercover youtube police.
Great video, my only question, if you knew you were going that far out why the heck didn’t you bring the big guns for the evac?
I actually have a lizard named jimmy too. My girlfriend really likes to play with him.
@marklabelle7371
4 жыл бұрын
LMAO
something similar to jeopardy music, very fast polka or bluegrass would have been great at the sped up part :))
2 wrenches, I like this guy already, 1 wrench guys drives me nuts. Watched many of techs try to undo a black iron union with 1 pipe wrench, Me...... woahhhhhh, use to wrenches, there is a reason, and you hand isn’t a wrench
'Jimmy' lives in that immediate area, watching out for cats & hawks, with a metal shelter and some water from sweating metal fittings in the hot weather.
It's a bit hard to here you talking. Love your videos......
I used to service telecommunications equipment. Troubleshooting is the same process for most stuff. So I would be interested in having you explain the gauge readings for the non hvac guy.
@hg2.
3 жыл бұрын
Ted does HVAC 102, not HVAC 101. There are lots of guys who do HVAC 101. Try Greyfurnaceman, Ty Branaman, or Word Of Advice channels, to name a few.
I pull vacuum with the appion 3/8" hoses down to 350 microns in less than 8 minutes.
@marklabelle7371
4 жыл бұрын
Trey Manning is that system vacuum or is that with a pump running?
Using a hand held acetylene tank is mint. I guess it only works on 3/8" copper, anything larger would need more heat. What type of silfoss is that, seems low temp also.
App ion core removers rated for 20 microns. Evacuate system in minutes.
Ted you didn't bring a fishing pole?😉 You could have caught dinner while waiting for that 500 number.
LOL, People are helicopters, however the lizard that was sent to spy is a "Buddy" & a "Friend"... Homeowner played this one smart!
Doesn't Jimmy have a HVAC technician assistant certificate from Spartanburg Tech College? I told the woman that I'd put it in but couldn't service it, and here I am servicing it. Sounds about right. lol 😎
I’ve had great luck installing the additive, shifting the reversing valve and letting the unit run awhile in both directions and not having toif
@tomburson5733
3 жыл бұрын
Change the valve
Cool.
Jimmy makes me laugh.
Good video!
👍
Min 13:30 Is that a pre-mixed can of ox-acetylene? That's pretty slick! Beats hauling around those 2 tanks, and hoses, and nozzles...
Man. I'd be pissed, if one of my guys set there tools on the customer washer. Big no, no. I do like watching your videos.
was that MAP gas and a 15% silver rod? I know MAP gas and Stay Bright # 8 works well, just curious? Love the videos!!!
Another subscriber made a good comment about they must be insured by Geico bc their gecko is hanging around. 😂
Nice replacement on the TXV, BTW, how did you get that celebrity "gecko" on your channel? You must be getting famous! :-)
What type of solder do you use. I noticed you used map gas to braze. Does that work on bigger suction lines as well? I just some stay bright #8 to try out.
@throttlebottle5906
5 жыл бұрын
mapp gas brazing is likely best on 3/8th or smaller, indoor and no wind or air blowing (no fans), obviously not near any valves or anything that doesn't like extended heating times
I thought Jimmy was toast when he ran across the outdoor fan blade.
When I saw the thumbnail I thought Roy was still alive.
Hey Ted what is that oil treatment you use?
Great working conditions don't know why you wouldn't want to service them. If it's a little further from your radius service area just charge more travel time.
I connect a CPS micron gauge to the system when I vacuum n it usually gives a lower reading than my fieldpiece digital manifold
I keep a fishing pole in my truck for just such an occasion.
@oldhandyluke
4 жыл бұрын
Great idea!
Not sure that I’d ever use map gas for brazing though,
@christopherwasmuth3678
4 жыл бұрын
It works, not sure id ever braze that with out something on the txv though 🤔
@jakelowe3526
3 жыл бұрын
It is nice to be able to hold it at any angle tho
@OleRazzleDazzler
3 жыл бұрын
Lol the longer I watch teds videos I scratch my head. But he’s a lovable guy. He does things a special way. Yeah, some things aren’t practical . But that’s why it helps old guys and young bloods working together and teaching each other stuff
@OleRazzleDazzler
3 жыл бұрын
Hey, if you don’t bubble flare joints, you’re asking for it. Such a risk taker .
@111000100101001
3 жыл бұрын
If used on small lines, like liquid with little heat sinking, you can knock it out if you’re proficient. The TXVs are pretty tolerant, if you don’t jack around and keep pouring heat into them. Yes, not ideal, but it works; ‘put it to bed and move on.’
My SMAN 3 gauges had a leak around the sight glass. The rubber gasket pulls in when you pull a vacuum on those. I took my sight glass out and sealed the gasket with the clear refrigeration sealer and tighten the brass ring. This is the problem with the sight glass gauges.
Oh an anole, very common in the south USA.
How long do you wait after adding Ac renew I usually leave it at least a day
Jimmy is alright, he’s just chill’in
Great videos but I need to chime in on the evac. Something totally wrong there, even if going through your manifold. I just did 60 feet of 3/8 and 7/8 and had it down to 250 microns in exactly 15 minutes and another 15 minutes to 160 microns, through my Titan manifold and Robinair 5 cfm two stage pump. I pull the schrader cores and use a 3/8 vac hose to the manifold which helps a lot. I would suspect your pump is bad and suggest connecting the micron gauge directly to it and see if you pull down to under 250 and how long it takes to get there. My pump with fresh oil gets to 16 (no typo) microns in less than 1 minute.
@Cuzzy420
3 жыл бұрын
Hahahahah my guy had way to much damn time on his hands cringe.
You use map gas to braze the copper line set?
Hey Ted, I'm always paranoid when I braze next to the TXV and I always use thermal paste. Is it not necessary? Those gaskets don't melt?
@shawnbologna8281
4 жыл бұрын
Don't really need thermo paste just a wet rag wrapped around the txv and it's only 3/8 " copper...if u are good with ur touching it should only take 10 or 15 seconds to make that solder joint, then quickly turn off ur acetylene and use just the oxygen from ur torches to slowly cool the joint
@ramonestrada38
3 жыл бұрын
@@shawnbologna8281 Good point. Of all my years brazing copper joint's I never thought about cooling the the joints with oxygen. I would always just let it cool down and at some point spray it with water or nothing at all. Good tip. Thk u
Tell that Lizard to stay out of your contactors and caps 😊
@animalcorvair
5 жыл бұрын
an fan
You should do a video of how to retrofit a r-22 system to a R-410a system
@BenTh17
5 жыл бұрын
Brandon Boyette You can’t put 410a in an existing R22 system, you’d have to replace the indoor and outdoor equipment. They do make some R22 replacements though, some require POE oil to be added to the system.
@sitanhuang9402
5 жыл бұрын
U can't, replace indoors and outdoors
@bboyette1017
4 жыл бұрын
@@BenTh17 my hvac instructor is a dumbass then
Does that field piece model of guage set always flicker ? It looks like it could be hard to watch.
@thebluelunarmonkey
5 жыл бұрын
No it won't. LCD displays flicker, but too fast for the human eye to perceive, but a video camera grabs images 30 or 60 times a second, so it can detect the LCD refreshing.
Top Jimmy. You a Van Halen fan?😁
How are you liking the fieldpiece
I was wondering did you replace filter dryer off camera or you don't have to do that when replaceing a txv. Thanks.
@joshl.158
5 жыл бұрын
R H drier may be internal to the unit so if he pumped it down then he wouldn’t change it.
@sitanhuang9402
5 жыл бұрын
He should, if drier was slightly blocked
@shawnbologna8281
4 жыл бұрын
Should always change the dryer anytime the system is opened
Changed one on a Bryant the other day, of course everything on the txv was brazed, when will manufactures learn about ease of service, not lugging tools and torches into a crawl space.