Sub-Zero Sealed System Leak or Restriction?

Тәжірибелік нұсқаулар және стиль

This video shows how to diagnose and repair sealed system problem, includes recovery, repair, and recharge.

Пікірлер: 13

  • @BUY.YOUTUB.VIEWS.314
    @BUY.YOUTUB.VIEWS.3145 ай бұрын

    better than most of the popular youtubers

  • @turtlebutt55
    @turtlebutt555 ай бұрын

    I think I remember somebody having a hydraulic pump to clear cap tubes but never tried it.

  • @SubZeroSpecialists
    @SubZeroSpecialists5 ай бұрын

    I have one but never use it

  • @dnpsubzro
    @dnpsubzro3 ай бұрын

    Hi ! Great Videos … I’ve been repairing Sub Zero’s for about 25yrs. You actually look familiar. Is this Arron ? NYC ? Nevertheless I have a question. 700 , BI’s and now I’m Seeing the IT’s with that extremely small drain hole. I went on an IT - 36 refrigerator not draining. I couldn’t find anything as of yet to get that angle to blow it out. I’m sure you’ve seen this. Any suggestions on what I can use to blow out that drain ? The angle doesn’t allow for a straight up blowout like on a 500 , 600 series. The 700’s were hard enough but this IT-36 is mind boggling.

  • @SubZeroSpecialists

    @SubZeroSpecialists

    3 ай бұрын

    Yes this is Aaron, I made a special tool using the 1/4” copper tubing that comes with the 500-600 series water valves, it has 90 degree bend in it. Send me your contact info and I’ll send you a pic.

  • @rajinramroop9572
    @rajinramroop95722 ай бұрын

    Hi - have a question. I have a 632 and my freezer temp fluctuates between 0 and 20 from time to time throughout the day. Have you encountered that before? Thanks

  • @SubZeroSpecialists

    @SubZeroSpecialists

    2 ай бұрын

    Many times

  • @mikhailtronik4322
    @mikhailtronik43225 ай бұрын

    Let's say your evaporator or accumulator is full of oil. Do you think blowing nitrogen through suction and out the cap tube at the filter would resolve the restriction? Thanks.

  • @SubZeroSpecialists

    @SubZeroSpecialists

    5 ай бұрын

    Yes I believe so, but then your compressor will need oil otherwise you might burn it out. There’s no way to check the oil level. If you can measure the amount of oil you blow out then you can add the same amount, that in my opinion would be the way to treat this problem.

  • @appliancedude63

    @appliancedude63

    5 ай бұрын

    ​@@SubZeroSpecialists Do you recommend any liquid flush to remove that oil or just dry nitrogen?

  • @SubZeroSpecialists

    @SubZeroSpecialists

    5 ай бұрын

    If you suspect acid or moisture in the system then flush it. It may eliminate problems afterwards.

  • @appliancedude63

    @appliancedude63

    5 ай бұрын

    @@SubZeroSpecialists what liquid do you suggest flushing it with?

  • @SubZeroSpecialists

    @SubZeroSpecialists

    5 ай бұрын

    Any HVAC flush