Solving the Puzzle - Installing Double Pole RCBOS, MCBs & RCDs?

Ғылым және технология

James Curnow delves into the wiring regulations to help you identify when a double pole protective device should be installed. He also reveals design considerations that need careful attention around applications, earthing and load variations.
================================
🔦 More electrical Q&A videos from eFIXX
👉 www.efixx.co.uk/electricians-...
================================
🆕 FREE CPD Learn about new applications, regulations and best practices with our FREE CPD modules. - New modules are released monthly, covering everything from surge protection to lighting.
👉hub.efixx.co.uk/CPD​
================================
📍SUBSCRIBE TO THE CHANNEL
eFIXX helps electricians, electrical contractors, building services engineers, and electrical apprentices. So if you've been on the tools for years or just starting your electrical journey, we'll help you stay up to date with the latest regulations and developments in the electrical industry.
👉hub.efixx.co.uk/youtube-subscribe
========================================
📺 NEW TO THE CHANNEL?
Watch our essential videos playlist
👉 hub.efixx.co.uk/essentials
=========================================
#electricalwiring #electricalinstallation

Пікірлер: 35

  • @efixx
    @efixx Жыл бұрын

    Learn more about EV chargers and double pole devices 📺 👉 kzread.info/dash/bejne/p6JnrbxxorrfXdY.html

  • @gbelectricks
    @gbelectricks Жыл бұрын

    Nice to see you with an efixx shirt James!! Keep up the good work 👏👍

  • @gardenogauge
    @gardenogauge Жыл бұрын

    Excellent informative video

  • @l3d-3dmaker58
    @l3d-3dmaker58 Жыл бұрын

    Electrician from Argentina here, we're obligated to use double pole equipment for everything, only exception is lighting circuits but it's still recommended, all circuits must be separate as there's a danger of backflow trough the neutral wire into your "off" circuit. been there, its a not so fun tingle. im always left confused as to why almost all european panels i see are mostly single pole with bonded neutrals on a bar, when our normatives derive directly from IEC ones.

  • @efixx

    @efixx

    Жыл бұрын

    What is the standard earthing system in Argentina?

  • @jooproos6559

    @jooproos6559

    Жыл бұрын

    In the Netherlands we switch the neutrals.

  • @rob19632

    @rob19632

    Жыл бұрын

    I think the answer to that is the neutral in the UK is nearly always connected to earth so is always at 0v.

  • @richardhince9764
    @richardhince9764 Жыл бұрын

    I'm an electrician in France. Just for interest: all circuits in this country are protected by double pole RCDs and MCBs: single pole examples don't exist.

  • @efixx

    @efixx

    Жыл бұрын

    Great info thanks Richard

  • @MarkUKInsects

    @MarkUKInsects

    Жыл бұрын

    I suspect that in time, the UK will do the same?

  • @SvenIronhand

    @SvenIronhand

    Жыл бұрын

    Same here in South Africa. I've never seen a single pole RCD. Here we call them Earth Leakages.

  • @NeneExists

    @NeneExists

    Жыл бұрын

    I don't think it's quite so important in the UK, since the socket preserves polarity

  • @paulroberts7561

    @paulroberts7561

    Жыл бұрын

    It's the same here in Spain.

  • @seanthespark
    @seanthespark Жыл бұрын

    Very informative 👏 👌

  • @XYLEMFIXX
    @XYLEMFIXX8 ай бұрын

    nice and detailed explanation

  • @johnwaby4321
    @johnwaby4321 Жыл бұрын

    That's raised some points 👍

  • @sergiofernandez3725
    @sergiofernandez3725 Жыл бұрын

    Can you explain the difference in a domestic setting single phase instalation between Double Pole and SinglePole with switched Neutral?

  • @Pgan803
    @Pgan803 Жыл бұрын

    Good subjects but lack of pictures, diagrams and examples

  • @mauriziodimichele4589
    @mauriziodimichele4589 Жыл бұрын

    hello guys, a warm greeting from Italy, your channel is just great! In our country we generally use 2-pole circuit breakers, the distribution system in the residential sector is T-T. In the UK I still haven't figured out the nature of distribution, what kind of distribution is it? always keep it up on your channel, you are bringing wonderful content. Hi everyone.

  • @efixx

    @efixx

    Жыл бұрын

    Thanks for the feedback - We’ll be exploring some installations in the South of Italy next month. Uk is mainly TNCS for properties built in the last 30-40 years. TT is still found in rural properties. Older town houses TNS.

  • @mauriziodimichele4589

    @mauriziodimichele4589

    Жыл бұрын

    @@efixx nice!

  • @johnburns4017

    @johnburns4017

    Жыл бұрын

    France mandates that all disconnectors in the main panels are _double pole._ This means they use twin L&N busbars (called a comb). It makes it all so much neater inside the main panel and safer. The British are behind. Schneider (French) sell DP RCBOs and RCDs using the comb busbar in the UK, emulating the French system. In fact better as the main panels have to be metal in he UK.

  • @scarydave7
    @scarydave7 Жыл бұрын

    Worth noting that some RCDs and RCBOs have fixed neutral, and that RCBOs can be referred to as "double pole" whether they have over current production on the neutral pole or not. Also, those caravans shown in the video are transportable units rather than caravans for regs purposes. Caravans are driven or towed with their wheels on the road.

  • @drkfuture1305
    @drkfuture1305 Жыл бұрын

    I m confused about Double Pole Circuit Breaker. I have seen a lot of pictures/videos which use one hot/live wire and one neutral wire as input and the corresponding output for each of them, whereas when I see the setup in the service panel box, it doesnt have the neutral input into the breaker itself, it takes two hot/live wires (from the service panel buses/two phases ) and two outputs accordingly. I am confused actually.

  • @doomain6769
    @doomain6769 Жыл бұрын

    Double pole MCBs / RCDs rcbos should really be used as standard tbf. So many neutral to earth faults when they are commoned up when Rcd protects multiple circuits

  • @darrenbone588
    @darrenbone5886 ай бұрын

    Great.... Just as confused as I was before. They don't word it nicely in the regs do they

  • @SME_Ste
    @SME_Ste Жыл бұрын

    Is a switched neutral device true double pole?

  • @1idd0kun

    @1idd0kun

    Жыл бұрын

    I think double pole is only when there's protection in both poles. If the device only has a switch for the neutral but no protection, I don't think it can be considered double pole.

  • @lancearmstrong3252

    @lancearmstrong3252

    Жыл бұрын

    @@1idd0kun Can you clarify what you mean by ''protection'' please? So what does that make a 20A double pole switch?

  • @doomain6769
    @doomain6769 Жыл бұрын

    I've never seen a reduced sized neutral conductor in a single phase or 3 phase installation.?? Where is regulation saying that it's acceptable to install reduced sized neutral conductors?

  • @MorzakEV

    @MorzakEV

    Жыл бұрын

    It is allowed if neutral currents are guaranteed to be lower. Can’t remember the regulation. Consider 3ph AC motor circuits which are perfectly balanced and therefore no neutral is required at all.

  • @rustamsayidif9840
    @rustamsayidif9840 Жыл бұрын

    Ok

  • @russelsprout2155
    @russelsprout2155 Жыл бұрын

    I wish you could have explained in plain English instead of reading directly from the regs.

Келесі