Socket Outlets - Aussie Wiring Rules & Rough-in/Fit off

G'day, welcome to 'The Electrician's Bible', a new series where I cover something specific within the electrical trade, go through my practices and bring up some relevant clauses from the Australian & New Zealand Wiring Rules.
🔗 Pocket Level Video
• All Electricians shoul...
⏳ TIMESTAMPS
00:00 Intro
00:55 How to Navigate AS/NZS 3000:2018
03:30 Clauses Relevant to Socket Outlets
10:26 Some Trade Practices
12:48 Outro
⚠️ WARNING
Do not attempt DIY Electrical work! All activities in this video have been performed by a Licensed Electrician for educational and entertainment purposes only. All work is done at your own risk. Corey Bruhn will not accept responsibility or liability, for any loss, damage, injury or negligence. Please consult a Registered Electrical Contractor or Electrical Inspector prior to dealing with any electrical installations. For more information visit: esv.vic.gov.au/DDIY

Пікірлер: 99

  • @saxcorp8437
    @saxcorp8437 Жыл бұрын

    Nice to have a Aussie electrician on KZread! Looking forward to some project videos!

  • @tyrellp0359
    @tyrellp0359 Жыл бұрын

    I’m a 2nd year electrical apprentice, enjoyed the video bro! Would love to see more like this

  • @mattwoods8907

    @mattwoods8907

    Жыл бұрын

    Yea 3rd year here that was good way of breaking the book down 👍🏼

  • @WakefieldRyan
    @WakefieldRyan Жыл бұрын

    Data cable can cross over LV at 90 degrees, it is stated in as2009 which is data cabling rules.

  • @somsz11
    @somsz11 Жыл бұрын

    Hey mate I'm a matured aged apprentice and this video helps. Appreciate it. Thumbs up

  • @OneIdeaTooMany
    @OneIdeaTooMany16 күн бұрын

    I'm currently looking into baby proofing electrical sockets because my son keeps pulling out cords but I found your KZread channel and it's awesome.

  • @nessnorimi9896
    @nessnorimi98965 ай бұрын

    You are a credit to your trade Corey!

  • @cheekynandos5706
    @cheekynandos5706 Жыл бұрын

    Sitting my capstone this year and this was helpful, good to see an AU sparky on youtube. Some more vids of the electricians bible would be great. Thanks :)

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Thanks, will do!

  • @mvckie3752
    @mvckie3752 Жыл бұрын

    This is a great informative video, Definitely need more fit off/rough in tips and trips!!

  • @jimic028
    @jimic028 Жыл бұрын

    Great educational video mate, keep up the good work!

  • @stuartrutt9524
    @stuartrutt9524 Жыл бұрын

    Thank you Corey i really enjoyed your lesson. I live in England and been doing a little research for family i have in Oz who have a problem so wanted to check how you do things there and not massively different to here. Great stuff.

  • @mattbates7099
    @mattbates70994 ай бұрын

    6:39 Krone data cabling standards suggest crossing at 90 degrees where necessary in order for the data system to still be certified as a Krone certified installation. Probably came from that.

  • @rainerl100
    @rainerl10010 ай бұрын

    Great video mate. Really helped. Keep them coming

  • @INMATE_0801
    @INMATE_08014 ай бұрын

    Good stuff mate, love to see it!

  • @michaelcostello6991
    @michaelcostello6991 Жыл бұрын

    Great video. Thank you. I hope you put up many more.

  • @andrewhowlett6373
    @andrewhowlett6373 Жыл бұрын

    Great video. More of this the better!

  • @shimarlie1
    @shimarlie1 Жыл бұрын

    Great videos mate. Keep going. You have created a great niche here.

  • @sunshine3187
    @sunshine3187 Жыл бұрын

    I worked as a spark in Australia, so much more relaxed over there than in the UK. Nice video mate.

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Cheers, what's the main differences between here and the UK?

  • @Chrisbishop79
    @Chrisbishop793 ай бұрын

    Wow, you give good video mate, that was truly awesome

  • @SwagScop3d
    @SwagScop3d Жыл бұрын

    I love your series as a one month first year from NZ my man more educational stuff on residential please!

  • @WeftySnowflake69
    @WeftySnowflake6911 ай бұрын

    I’m stuck in Data as an apprentice, I need more videos like this Corey!! 💔😫😂

  • @truthfreedom
    @truthfreedom Жыл бұрын

    Good work Corey

  • @thenewsydneyguy8662
    @thenewsydneyguy86626 ай бұрын

    Bro you're doing Gods work. Keep going!

  • @theonlyjumpyhumpy
    @theonlyjumpyhumpy4 ай бұрын

    Can confirm that the 90 degree rule was in my open cabling licence course. The interference risk is lessened in this format, however unless the cables are fixed, you can't be sure they still stay at 90 degrees so best to segregate or separate.

  • @Najeb_Dawoodi
    @Najeb_DawoodiАй бұрын

    Really enjoyed this video 🔥🔥🔥🔥 Would like to see more of this videos, really practical 🤙🏼 (Breaking down the rule book) Thanks

  • @dodgeybros76
    @dodgeybros765 ай бұрын

    Great vid! super keen to see another one on something electrical (wiring lights? air cons? ). my tradies show me what they do but you show us the Code too. Very helpful.

  • @bonaminhrasmey42
    @bonaminhrasmey428 ай бұрын

    ❤thanks for sharing your video 😊

  • @alexrobertson232
    @alexrobertson23211 ай бұрын

    Thanks for the great content mate. 2nd year sparky apprentice here.

  • @hw1282
    @hw1282 Жыл бұрын

    Great video, first year apprentice from NZ, much much more clearer explained than my tutor, thanks!

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Glad I could help!

  • @malikbasitjatoi

    @malikbasitjatoi

    Жыл бұрын

    I am electrician need job

  • @malikbasitjatoi

    @malikbasitjatoi

    Жыл бұрын

    I am electrician need job please help form Pakistan

  • @user-oh6nn2gj3x
    @user-oh6nn2gj3x8 ай бұрын

    Good explanation.

  • @TheSimpleLivingAussie
    @TheSimpleLivingAussie2 ай бұрын

    Nice to hear someone talk through the regs. I would have loved to do an electrical engineering degree but my reading is not to good (dyslexic) and getting through those all those work books would do my head in. Plus I am getting to old now to be climbing up inside roofs of houses 😂

  • @mujeebmirza6012
    @mujeebmirza60128 ай бұрын

    Many Thanks, Good Knowledgeable Electric Vd AU standard.

  • @justinfarquhar8299
    @justinfarquhar8299 Жыл бұрын

    Thanks bro! The regs are easy to read but can be a little dry. Nice to have an overview

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Yeah I'm trying to encourage apprentices to regularly look up the regs and not be bored to tears by them

  • @bonaminhrasmey42
    @bonaminhrasmey427 ай бұрын

    ❤your details 😊

  • @kodineill222
    @kodineill2228 ай бұрын

    Bro pls do more videos like this im an apprentice and this was helpful as

  • @u305840
    @u3058408 ай бұрын

    Love the pain explanation of topics - gold! Two questions, generally standard area point are like you said "300mm High" For other people watching, you meaning 300 to the horizontal centre of the plate (i.e. screw fixtures) or to the bottom of the plate? Secondly, when using metal mounting gang plates, are their and different fixing rules between timber and metal studs?

  • @user-hv8iq9cw2p
    @user-hv8iq9cw2p4 ай бұрын

    G’Day Mate. Love your videos. Quick question? What size wire should be run from the house metre box to the shed power box? Just want to make sure my tradie is doing it correctly? The shed is a 9x6 standard size 5xpower points with all standard house hold tools used. Any info would be much appreciated mate

  • @bri200490
    @bri20049011 ай бұрын

    Nice info mate . In NZ we tend to use flush boxes , not just for power points but for the light switches as well at the rough in stage . And hope like hell the gib fitters cut out the points

  • @refaiabdeen5943
    @refaiabdeen59436 ай бұрын

    Cheers Mate

  • @tedmaulassociate4063
    @tedmaulassociate40638 ай бұрын

    Watching this as a layperson because I need to drill into the stud directly to the right of the power point and I want to make sure I don't hit any cable. This video was useful as no one ever covers the rough in stage and typical wiring patterns! I'm still not sure if there's wiring running up the side of the stud that I could hit but it helps anyway. Can you do a video of typical rough in locations of an aussie house for electrical outlets? Like if a power point is located low on the wall, just above baseboard and there's a stud right next to it, where are the no-go zones for drilling? I tried a stud finder with ac detection but of course it detects the whole wall because there's electrical behind there.

  • @michaelsimpson9779
    @michaelsimpson97792 ай бұрын

    Yep, 60mm segregation or 6mm thick barrier between comms/TV and mains. More so for potential vermin damage etc to prevent a contacting fault. Close parallel runs should be avoided due to inductive noise as well.

  • @pistolasnine8389
    @pistolasnine8389 Жыл бұрын

    Hi Cory, what's the standards for wiring an 20amp oven? Does the wire need to be inside a pipe?

  • @Video-ue1vr
    @Video-ue1vr4 ай бұрын

    Hello, just wonder what size cable I should use for electrical socket in Australia?

  • @jacobholland5864
    @jacobholland5864 Жыл бұрын

    Thank you for the educational video. I am looking forward to starting my apprenticeship next year. I presume that throughout my apprenticeship and subsequent career, I will be constantly referring to this bible on a regular basis?

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Good luck mate! You won't really be referring to it on the job because the A-Grade Electrician you're working with will already be on top of most wiring rules, however it's good practice to look up the AS 3000 in your spare time, especially in regards to what you've been doing at work

  • @wurlabyscott
    @wurlabyscott11 ай бұрын

    Aussie house wiring, how much power is on one power leg?

  • @jiovannifuria451
    @jiovannifuria4512 ай бұрын

    Good day mate ,where can I buy the modules for electrical standards installation in Australia.because I’m planning to take electrical course next year and I want to have an advance study

  • @geoffgeoff143
    @geoffgeoff1435 ай бұрын

    It depends where a socket outlet is used as to whether it is a GPO or SPO.

  • @hungnguyenquoc9487
    @hungnguyenquoc9487 Жыл бұрын

    Hello thanks for the video. You said that the sockets are rated at 10amps, but the rcbo is 16 or 20amps. Why is it much more than 10amps? Also, with a heavy appliance such as washing machine which uses more than 10 amps, can it be used for this 10 amps socket? I have heard that more power can still go throught the 10amps socket. Thanks

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    You usually have multiple 10A socket outlets on the one power circuit, a lower rated circuit breaker will cause nuisance tripping. The RCBO is also rated to protect the cable, which for power circuits it's generally 2.5mm. Appliances that draw more than 10A will have a 15A or higher plug, meaning they won't plug into your standard 10A socket outlet and will need a higher rated outlet

  • @shrestha201
    @shrestha2019 ай бұрын

    Where can I download the PDF? Could you share the link please?

  • @johnpatterson9669
    @johnpatterson9669 Жыл бұрын

    Can you do a video explaining looped at the light vs looped at the switch?

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Thanks for the idea man

  • @blairwilson9272
    @blairwilson9272 Жыл бұрын

    very educational! Any tips on not nicking the copper with the Marvel's? Just got a pair and wow they are so damn sharp!

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Yeah I might make a video on other ways to strip sheathed cable. Start by just making a course line where you want to strip and then pull the inner insulation from the end. Yeah it'll take longer but you'll know you're not unintentionally nicking any of the conductors

  • @blairwilson9272

    @blairwilson9272

    Жыл бұрын

    @@coreybruhn yeah that is also a good technique, was doing that with round cable so will give it a go with flat. Thanks for your reply and content, very appreciated!!

  • @aussietingles4699

    @aussietingles4699

    Жыл бұрын

    Been using marvel cross cuts for 7 years now, my biggest tip when getting new ones is cut the shit out of 6mm² until they aren't razor sharp.

  • @blairwilson9272

    @blairwilson9272

    Жыл бұрын

    @@aussietingles4699 Thanks for the suggestion, will get cutting!

  • @jasondevine6014
    @jasondevine6014 Жыл бұрын

    The crossing isnt in wiring rules but I the data standards for emf. Conduit over one of them as you did is the go.

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Yep crossing is only allowed for undercarpet cabling as stated in AS/CA S009:2020

  • @sovietrazors
    @sovietrazors3 ай бұрын

    Do a video on installing lighting

  • @syrus1233
    @syrus1233 Жыл бұрын

    Hey I’m going to start my apprenticeship but my company only does industrial and telecommunications work. My boss just told me I won’t get the residential and commercial experience. Is this a bad idea should I get and apprentership somewhere else.

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    I reckon go with it! You can always move companies later on if you're wanting experience elsewhere

  • @XvTOASTvX
    @XvTOASTvX Жыл бұрын

    do you think youd be able to film roughing in some lights power etc and also fit off that be good to watch even if youre not talking just like a time laspe of it or something

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    I'm planning to eventually! (I like the timelapse idea) When I obtain my REC next year I'll be able to work for myself and I'll record everything, however atm I can't really film myself on the job because I'm being paid to actually do work, not make youtube videos haha

  • @XvTOASTvX

    @XvTOASTvX

    Жыл бұрын

    @@coreybruhn fair will be great to see mate as I am a industrial electrician in nsw just moved to solar commercial/ residential with residential work mostly solar at the moment but would be great to see how to go about the residential side of things

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    @@XvTOASTvX Sick! How are you finding solar? I just did the grid connect course a couple of weeks ago

  • @XvTOASTvX

    @XvTOASTvX

    Жыл бұрын

    @@coreybruhn I’m doing design and install course for CEC clean energy council at the moment lot of course work in short time frame but the actual work is good day goes quick but isn’t exhausting it’s rather rewarding the system at its core is quite simple. I wouldnt say just do solar would get boring eventually but it has been fun so far!

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    @@XvTOASTvX Yeah the one week course was a lot to take in, I've still got to submit some modules online, that's why I've decreased my uploads a bit

  • @jobkaa2243
    @jobkaa22434 ай бұрын

    I am doing third year studying in electrical engineering and need a soft copy of wiring

  • @MINIDISK111111
    @MINIDISK111111 Жыл бұрын

    your still crossing at 90s even if your running a bit of corrro, The corro is because the sleeve of most cat cables isnt rated at 240. the 90 degree thing is about interference

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Regardless our cat and LV cables still need to be separated by a barrier if they're within 50mm of each other in order to comply with AS/CA S009:2020 Clause 16.3.1

  • @MINIDISK111111

    @MINIDISK111111

    Жыл бұрын

    @@coreybruhn yeah what i said.

  • @pukarpoudel3284
    @pukarpoudel3284 Жыл бұрын

    Hi Corey how are you there.from where,I can get your book please??

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    You can access the wiring rules through trade school, your employer, NECA, MEA or pay for it on the standards website (which is expensive af)

  • @MyRedStallion
    @MyRedStallion Жыл бұрын

    New amendments regarding rcds you need to always use an rcd unless it causes damage to the equipment being protected eg sensitive equipment.

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    You're right in regards to domestic situations only in Australia. RCDs in 32A circuits or less is non-domestic, I should have made that more clear

  • @user-xh7xj5lf8k
    @user-xh7xj5lf8k Жыл бұрын

    Bro tafe teachers have always been telling us the data cable must cross the power cable 90 degrees lol , I’m sure its in the Philips as well man

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    The only way I can see that you can cross power 90 degrees is with pink c-bus data cable as that particular cable can run with power but in terms of your normal cat6 you can't. Look it up in the communications regs and let me know where it says you can and I'll correct myself

  • @shibuabraham7305
    @shibuabraham7305 Жыл бұрын

    Hi My name is Stephen from Kerala, India. I have started my migration process to Australia as a skilled migrant. As a part of the program, I was assessed by the vetassess and Got positive skill assessment results and electro technology 111 electrician certificate. Based on the certificate, can I get a job as an apprentice in Australia.

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Haha I'm getting a lot of comments from people wanting to migrate and become a sparky here and I honestly don't know the answer. Try Googling around, I'm sure there's plenty of resources out there Also I ain't a boss lol

  • @shibuabraham7305

    @shibuabraham7305

    Жыл бұрын

    Thanks for the reply. My doubts is that having certificate 111 is allow to work as a apprentice electrician in Australia

  • @stuartjlee1351
    @stuartjlee1351 Жыл бұрын

    Most based man on youtube

  • @JohnSmith-ms2cl
    @JohnSmith-ms2cl3 ай бұрын

    NEEEEEEEERD

  • @geoffgeoff143
    @geoffgeoff1435 ай бұрын

    You have a LOT to learn.

  • @markrainford1219

    @markrainford1219

    4 ай бұрын

    Do you mean he has a lot to learn, or a lot to learn? 🤔

  • @manishreddy1788
    @manishreddy17886 ай бұрын

    Hi... could you share the link to download AS/NZ 3000??

  • @adelaideprecisioncarpentry2555
    @adelaideprecisioncarpentry25555 ай бұрын

    I'm a piece of shit carpenter. Cheers for the tips

  • @RogerRoger15
    @RogerRoger153 ай бұрын

    Do you guys make good money in australia. I know you have a housing crisis but can you easily afford a decent life.

  • @BackyardRussia

    @BackyardRussia

    Ай бұрын

    Electricians make plenty.

  • @user-ej5rq9gj9b
    @user-ej5rq9gj9bАй бұрын

    Bro can U send me pdf version plis🙏

  • @mrseanpride6449
    @mrseanpride6449 Жыл бұрын

    Love the vids. I can’t be bothered looking at the standards but im pretty sure there is a note about using 1.5 for socket outlets if they are 15amp or dedicated circuits. Also, im pretty sure if you get the actually communications standards it mentions that extra low voltage and low voltage can cross over. They use the wording something like cables must not run parallel no less than 150mm. Also, I hate those new Clipsal mounting blocks. They look slick but the support on the fixings is piss weak and the thread for the gpo screws is just plastic and can Fuck out. Doesn’t happen often but annoying as fuck when it does.

  • @coreybruhn

    @coreybruhn

    Жыл бұрын

    Thanks mate! I think you're talking about Table 3.3 Exception 1? "Smaller conductors may be used on subcircuits supplying socket outlets, based on their suitability, in accordance with this Standard, and taking account of voltage drop, current-carrying capacity and reliability of connections" I had a look at AS/CA S009:2020 and you can only cross data over at a right angle for undercarpet power cable. Yeah I agree! You just gotta be real gentle otherwise you'll crack the plastic.