SHOCKINGLY BAD ELECTRICAL WORK BY THIS INSTALLER

Ғылым және технология

SHOCKINGLY BAD ELECTRICAL WORK BY THIS INSTALLER.
Join me as I do an EV Charging Installation where everything goes wrong...
Subscribe to our KZread Channel for more great electrical content: kzread.info...
-----Electricians Business Course-----
📩 Sign Up To My Electricians Business Course Here And Get The First 4 Lessons Free 👇
➤ course.electriciansbusinessco...
TIS560 Earth Leakage Clamp Meter Review: • TIS 560 Earth Leakage ...
--MY ENERGY PROVIDER--
Bulb - Use this referral link and we will both receive £50! www.bulb.me/andrew8530
The following ADVERTS help our channel to survive:
Unilite SLR1000 Work Light: amzn.to/2IMZFRi
🔔 Subscribe to TOOLS4SPARKS KZread Channel 👇
I Also Have A Dedicated KZread Channel About Tools:
➤ / tools4sparks
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB/?tag=a...
-----TRADES INSURANCE DISCOUNT-----
If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote
📞 or call 01162437904.
📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
#VehicleCharging #ElectricianLife #ArtisanElectrics

Пікірлер: 507

  • @artisanelectrics
    @artisanelectrics2 жыл бұрын

    Subscribe to our KZread Channel for more great electrical content: kzread.info

  • @mgabrielle2343
    @mgabrielle23433 жыл бұрын

    You got me going there with your Earth leakage tester, I think I know why when you measured leakage on the pair of meter tails, it registered 11 odd mA leakage, and yet when you measured on that earth wire it measured zero mA, so what that means is the earth leakage current is not going through that yellow green conductor, but is getting earthed somewhere else , directly into ground either through pipe work etc, so that should stop you scratching your head. And of course, you need to enclose both live and neutral in the tester jaws, and any common mode load currents would cancel each other giving you any differential mode current read out, so even if you had a load of 5 amps you would be seeing 5.011A in the live conductor and returning exactly 5.000 amps, whereby 0.011A going into the ground through another earth point and not that yellow green earth conductor.

  • @phoenixlogic6927
    @phoenixlogic69273 жыл бұрын

    Videos like this are really helpful for trainee electricians :)

  • @johndevine6288
    @johndevine62883 жыл бұрын

    Great video, keep them coming. Like your way of presenting bad situations and remedial work you have to perform (if you can) to rectify the problems.

  • @carterglover3539
    @carterglover35393 жыл бұрын

    To resolve having 4 conductors in the MCB where you have doubled up the ring you could have connected one leg of ring 1 to one leg of ring 2 with wagos and then you've got one bigger ring 👍

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Lovely idea!

  • @TeamSimpsonRacing

    @TeamSimpsonRacing

    3 жыл бұрын

    True but you may make the circuit to long and then not comply with volt drop 👍

  • @carterglover3539

    @carterglover3539

    3 жыл бұрын

    @@TeamSimpsonRacing Rings can cover 100m2 area and those circuits combined only total the upstairs floor of the house

  • @TeamSimpsonRacing

    @TeamSimpsonRacing

    3 жыл бұрын

    @@carterglover3539 you would think so. Makes you wonder why they did two rings for upstairs 🤔

  • @carterglover3539

    @carterglover3539

    3 жыл бұрын

    @@TeamSimpsonRacingGood point, maybe an old extention?

  • @farmersteve129
    @farmersteve1293 жыл бұрын

    Fundamental mistake there in trusting a supplier... with such a critical part I avoid booking in a job until I have the part in my grubby little hands because if a supplier or courier can mess up there's a high likelihood that it will happen!

  • @robertbritton656

    @robertbritton656

    3 жыл бұрын

    @@r.h.8754 Service engineer as well and that happens far too often.

  • @jean-pierredeclemy7032

    @jean-pierredeclemy7032

    3 жыл бұрын

    And once it is booked don't bother trying to divert it because it ain't going to happen.

  • @Golommod
    @Golommod3 жыл бұрын

    I love how you big things up what are wrong but it is actually easy fix

  • @mathman0101
    @mathman01013 жыл бұрын

    Some points for future. When using earth leakage meter beware you may not be able to read a value if clamping around the CPC as there are possible other multiple pathways to earth - the gas and water bond, you would have to remove them to see it. Looking at the imbalance on LN was the best approach. On RCD tripping you have to remember the cooker/oven has probably a capacitor built into the electronics which with the long run you had could be causing the tripping. If it was a type AC I would replace with a type A. For EV charging when you have to TT my advice is to carry a soil test kit. This has several benefits in that you put the right type of earth rod in. With soil ph around 8 or more you can get corrosion of a pure copper rod reducing the protection over time in using the charger. Two ways around this either get a copper rod which is anodized with a noncorrosive metal on the surface or get a larger steel rod. I would also surround the copper rod. In concrete as well providing more reliable earthing and reducing the possibility the earth rod resistance would go up in summer. Anyway nice work as always.

  • @sstorholm

    @sstorholm

    3 жыл бұрын

    I was about to say the same thing, earth leakage can be any path to earth and back to the star point on the transformer.

  • @markhoulding1938
    @markhoulding19383 жыл бұрын

    Good vid Like your positive attitude am sure your customer will be grateful 👍

  • @davidjrb
    @davidjrb3 жыл бұрын

    This has been a real joy for me to watch. Definitely liking and subscribing. I love the humility and honesty of your commentary. (Electrician in Iceland)

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Thanks David! Welcome to the channel!

  • @heliharris69

    @heliharris69

    2 жыл бұрын

    You make interesting video's... Shame your prices are so high for installing EV chargers.

  • @Blackf1ngers
    @Blackf1ngers3 жыл бұрын

    Regarding the mess in the top of the Mantel box, we often use a piece of paxolin and a couple of little angle brackets to fix it.

  • @TheChipmunk2008

    @TheChipmunk2008

    3 жыл бұрын

    Yes, that's what I've done in our place

  • @MrGruster
    @MrGruster3 жыл бұрын

    Might have been worth linking out the two ring final circuits to form one ring, to avoid putting four cables away in one terminal. Always enjoy your videos! Hope the job ended well 👍

  • @grahammchardy5531
    @grahammchardy55313 жыл бұрын

    Do love the dentist mirror for checking. A great idea. A phone can sometimes be too big to get in there properly.

  • @delcat8168

    @delcat8168

    3 жыл бұрын

    Oddly, his dentist uses a continuity tester to check his fillings ;-)

  • @ChrisShucksmith
    @ChrisShucksmith3 жыл бұрын

    If your 11mA of leakage isn’t returning via the consumer unit earth block, check the bonds and also clamp the water and gas pipes before and after the bonds, as it might be going out via services. You might have a screw somewhere through a live leaking it to the fabric of the building. Clamp the circuits and see if you can track it down.

  • @marrowsandoug
    @marrowsandoug3 жыл бұрын

    Been let down so many times by deliveries I now only book work when I have the ordered parts in my pocession!

  • @alistair1978utube

    @alistair1978utube

    3 жыл бұрын

    funeral procession? or another kind?

  • @CurvedSlightly

    @CurvedSlightly

    3 жыл бұрын

    @@alistair1978utube *Possession, illiterate tradie.

  • @dextergodfrey7086
    @dextergodfrey70863 жыл бұрын

    Instead of adding two rings into the CB - could you of linked the rings in the board? Making one ring? Obviously considering the total length. Love the videos ;)

  • @Accomplice23
    @Accomplice233 жыл бұрын

    Don't be afraid to name and shame, it's good for consumers. Wel Electrical Services (London).

  • @Fishbait075

    @Fishbait075

    3 жыл бұрын

    WEL.... That escalated quickly.

  • @thesocialhandgrenade8474

    @thesocialhandgrenade8474

    3 жыл бұрын

    not a good place to go for him being a business, indemnity insurance might cover a subsequent deformation court case but not worth it. it is only one opinion versus another

  • @TheChipmunk2008

    @TheChipmunk2008

    3 жыл бұрын

    @@thesocialhandgrenade8474 yes that exactly. It's not a good idea to be poking the bear. if there's a real problem, i'd contact their CPS (have done it before)

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Customer has reported them

  • @ealingwest5750
    @ealingwest57503 жыл бұрын

    Oh dear I can read the details on the WEL Electrical Services sticker at 2:39

  • @UberAlphaSirus

    @UberAlphaSirus

    3 жыл бұрын

    I googled the number, same, French yahoo email too.

  • @123tinhat123
    @123tinhat1233 жыл бұрын

    I use a dentists mirror on the busbar when connecting up, very handy👍

  • @bramcoteelectrical1088

    @bramcoteelectrical1088

    2 жыл бұрын

    Me too

  • @briansunderland8992
    @briansunderland89923 жыл бұрын

    When I lived in the UK in Luton worked as a washing machine tech 1966 to 1970 went out to Cambridge , Stevenage , North London all villages around Luton and Bedford even at times Canvey Island most I could do any day was 4-5 jobs 70 thousand miles a year 8- 12 hours Monday to Friday over half the time in traffic lasted before I had a minor heart attack so Jordan I know about stress and frustration with parts not delivered

  • @heatpump8566
    @heatpump85663 жыл бұрын

    My pal says most sparkys are frustrated plumbers. Great video again, really enjoyed

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    LOL

  • @BenCos2018

    @BenCos2018

    3 жыл бұрын

    lmao

  • @terrymeade1930

    @terrymeade1930

    3 жыл бұрын

    Plumbers are failed electrician's. Just saying haha.

  • @roceloi

    @roceloi

    3 жыл бұрын

    Im a sparky and I hate plumbing...

  • @labelectrical
    @labelectrical3 жыл бұрын

    Great vid, love your testing and fault finding content. You need to to be sending an invoice to Anderson's Electrical for your lost time due to their incompetence. Glad you called them out though, might make them up their game 👍

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    👍

  • @evguysltdianlawrie2274
    @evguysltdianlawrie22743 жыл бұрын

    The BG garage consumer unit IP65 is the best product they make. The remainder of the consumer unit range is bloody awful! Any attempt to do RCBO’s causes the din rail mountings to fracture 😡 Contactum on the other hand, I do like. I’m glad you said the DNO were going to upgrade the old cable head. I’ve an ace relationship with SP Energy Networks sub contractors IQA. 70% of all EV Chargepoint I fit need the cable head upgraded. Also, came across a new build recently with a series 7 head. Thought it would have an 80Amp fuse, which is standard....Nope! 60Amp! Thankfully, I carry 80Amp Lawson’s in the van.

  • @jonathanstephens7804
    @jonathanstephens78043 жыл бұрын

    Nice work mate not too sure about the 2 rings off one mcb I would of preferred to of replaced the devices with contactum rcbos which would of left 2 spare ways to use. Obviously a cost but a much better install along side the shiny new charger :)

  • @electricery
    @electricery3 жыл бұрын

    I use a dentist mirror as well I covered the handle in heat shrink to give me a bit of protection

  • @Geeraffe
    @Geeraffe3 жыл бұрын

    nice work as always - fyi electricians insulated dentist mirrors are available - Boddingtons UK

  • @lukapopovic6668
    @lukapopovic66683 жыл бұрын

    Same weather here in Singidunum as well

  • @paulmorrey733
    @paulmorrey7333 жыл бұрын

    Thanks Jordan

  • @johnfenlon458
    @johnfenlon4583 жыл бұрын

    Great Job!! Good idea to use a circle mirror to see inspection. I am concerned about 100A of the main black box where brown 16ml wire. I noticed Brown 16ml wire on top touched on Natural (yellow) wire. I think you should take out the Natural (yellow) wire from brown 16ml wire then move above near the Main black box. Can you try this? Need a good safety. Thumb up!! Cheer!

  • @erwintetenburg1474
    @erwintetenburg14743 жыл бұрын

    Really like your videos. I'm learning a lot. Have you ever worked or have some kind of idea about the Heatmiser Neo Electric underfloor hating thermostat and hub.

  • @TheShinnion
    @TheShinnion3 жыл бұрын

    That’s the first time I’ve seen a pvc gland installed upside down 😂😂😂

  • @paulprescott7913

    @paulprescott7913

    3 жыл бұрын

    Yeh how on earth can you get that wrong.

  • @dennisreid4428

    @dennisreid4428

    3 жыл бұрын

    I spotted that and wondered "WTF" and why do it like that?

  • @PurityVendetta
    @PurityVendetta3 жыл бұрын

    That was an interesting thing I didn't know when you mentioned USB sockets creating a relatively high earth leakage current. Personally I hate the things as I think most of them are cheap and nasty chinesium curtain burners but it's a useful bit of knowledge to have.

  • @KX36

    @KX36

    10 ай бұрын

    any modern device will have some earth leakage. Switching power supplies in modern devices have a class Y capacitor across the transformer to suppress EMI. The secondary side is earthed (class I) or double insulated (class II). The primary is live and neutral rectified. capacitor from live/neutral to earth creates earth leakage. Personally I don't like USB sockets because they're like having the cheapest £5 charger permanently plugged in. They won't have modern fast charging features, so they'll be obsolete almost immediately, they probably don't have great isolation from primary to secondary, and they're probably very noisy and wasteful with their standby power.

  • @philipwardle6820
    @philipwardle68203 жыл бұрын

    Very interesting Jordan, thank you. In this case it look like the customer misled you, to some degree, as to their rediness for you to do the installation - of course this may not have been deliberate, thay may have been misled by others. How you fo deal with this situation, for example do you try to negotiate an additional fee for you time in sorting the issues, or do you stand by you original quote and just accept that "some you win, some you lose". I'm thinking that, over time, if wins and losses cancel out maybe you've concluded that you have your estimating strategy about right?

  • @ianbooth5374
    @ianbooth53743 жыл бұрын

    I've been using these soft tails for a while now. They are so much easier to work with. It's best to untwist them a bit before going into the main switch. Does anybody else not have much faith in those small allen key terminals used for the 100a dp switch. I have tried to get a torque version. I use a Boddingtons T bar at the moment.

  • @Cjrelectrical
    @Cjrelectrical3 жыл бұрын

    Shocking work does not shock me it’s an everyday occurrence. 👍

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    I know right! 😂

  • @seandunne2673

    @seandunne2673

    3 жыл бұрын

    Shocking 😂 bad pun.... (probably not intentional though 😂)

  • @lonewolfgeoff

    @lonewolfgeoff

    3 жыл бұрын

    bbzzzzzttt ⚡️⚡️

  • @JamesSherlouk

    @JamesSherlouk

    3 жыл бұрын

    @@artisanelectrics Seriously, what's the best way to find an electrician who's going to do a good job? bout to get my place rewired in Derby but these horror videos scare the life out of me 😅

  • @tanhem5639

    @tanhem5639

    3 жыл бұрын

    @@JamesSherlouk from learnt experience, get a feel and look at their current work. These KZread videos were what sold Artisan to me!

  • @brianoneill350
    @brianoneill3502 жыл бұрын

    Thanks for video. Tidy work

  • @ursamajor6546
    @ursamajor65462 жыл бұрын

    Aside from the rising inflection at the end of every sentence - a good video!

  • @iain7777
    @iain77773 жыл бұрын

    Enjoying your videos, thanks for sharing! Is it the DNO that should be responsible for installing a dual pole isolator switch. I have a similar arrangement to how you described this property originally where there was no isolator switch just the DNO fuse to a Henley block used to feed two different (main and extension) consumer units. The Henley block case is cracked so I know it will need isolating to replace at very least and thought an isolator switch sounds like a good idea anyway. Contacted my DNO and they say they’re only responsible for the fuse and I need to contact my supplier (who I pay my bills to) for an isolator switch quote, does that sound correct?

  • @stevenbrooks8323
    @stevenbrooks83233 жыл бұрын

    Could you not have joined one leg of each ring to make one big ring, if the earth loop wasn't to high.

  • @Graza25

    @Graza25

    3 жыл бұрын

    Thats what i was thinking. I would have probably done that. I suppose there's not much difference.

  • @Sibbe2560
    @Sibbe25603 жыл бұрын

    As a foreigner I have worked on quite a number of electrical installations in the UK. Most of them looked exactly like this one, so it doesn’t surprise me.

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    😂

  • @Liveyourlifewithafatcigar
    @Liveyourlifewithafatcigar3 жыл бұрын

    Jordan can you tell what cable cutter device you used in the consumer unit when you were fitting the tails. I fit smart meters & i am always looking for something better than cable cutters. Thanks

  • @petertallowin6406
    @petertallowin64063 жыл бұрын

    Yep, lower left 4 looks a little loose..... Awesome tip on that mirror. Lovely job Jordan. You have probably mentioned this before but where did you get the cable stripper? Is there a link to it on your tools page?

  • @westinthewest
    @westinthewest3 жыл бұрын

    Those red and black tails rising into the consumer unit might turn out to be compliant. I've seen similar ones where there are two layers of PVC, with the sheath using the same colour as the insulation. It can be tricky to be sure without stripping a small section and seeing if it comes off in separate layers. I wonder if the cable can be confirmed as sheathed if it has the usual markings on it like BS6004 6181Y?

  • @Thegardener87
    @Thegardener873 жыл бұрын

    I really like your videos but the motion sickness is real!

  • @danf6491
    @danf64913 жыл бұрын

    I would have joined the lighting circuits on this one to free up a spare way with it being a single rcd board. Does the ev charger have a type s rcd as I was wondering about the high earth leakage already

  • @robswingler
    @robswingler3 жыл бұрын

    Earth leakage clamp is always best to put round the tails for an accurate reading as the main earth will probably have abit of diverted neutral current going through it . That’s why it was overloading on the mil amp range.

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Thanks

  • @Moletrouser

    @Moletrouser

    3 жыл бұрын

    Is that (unmeasured, but apparently more 20mA) earth current inductively coupled then? It would seem to be much larger than the live-to-neutral imbalance.

  • @sambothebold
    @sambothebold Жыл бұрын

    The DNO fuse was still in right? But you had the main tails isolated via that low level isolation switch?. But there was no lock off on the switch as far as i could see. Ive had main switches that switch almost with the touch of a feather. I was getting twitchy bum hole syndrome when i saw you working on the tails 💩 I also love the mirror for breaker/bus bar inspection. Absolutely great tip Jordan. You are a real inspiration and a bit above the rest when it comes to sharing your business on social media. Well done, hope i can be as good as you one day

  • @donnierobertson3088
    @donnierobertson30883 жыл бұрын

    Nice job and video like always

  • @ericrawson2909
    @ericrawson29093 жыл бұрын

    When I moved into my house there was a 4mm2 SWA cable connected to the henley blocks. That was definitely a fire risk.

  • @keithquestedelectrical9785
    @keithquestedelectrical97853 жыл бұрын

    Boddington do a really good insulated mirror Good video Jordan

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Cool thanks

  • @dirkus3722
    @dirkus37223 жыл бұрын

    Hello from US (please send help). Thanks for the video; always cool to see interesting differences between US and UK.

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    👍😁

  • @TBFSJjunior

    @TBFSJjunior

    3 жыл бұрын

    Same from me here in Germany. Even though UK wiring is similar, we have 3 phase most of the time over here.

  • @grahamwise5719
    @grahamwise57193 жыл бұрын

    The metal box is original to the house, the consumer box is where the main switch and fuses were. This would have been the rubber cables usually in the wall cavity dating from the 1950s.

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Thanks

  • @MalcolmCrabbe
    @MalcolmCrabbe3 жыл бұрын

    I watch quite a few channels like this, and there seems a trend where when poor workmanship is found that doesn't meet code those who discover it don't want to name and shame or report them to the authorities that govern the installation standards. Maybe if there was some form of reporting, and some for of registration like in the gas industry there would be less cowboys around and installations would be a lot safer as anyone cutting corners would be "struck off" or have to pass some form of exam

  • @m.bmaintenance7834
    @m.bmaintenance78343 жыл бұрын

    unfortunately work like that seems to becomng the norm, and until someone gets a grip on the industry it wont change

  • @julieannecharters6132

    @julieannecharters6132

    3 жыл бұрын

    yep fast track courses and no on job experience its only going to get worse.that work is piss poor

  • @mfx1
    @mfx13 жыл бұрын

    You may not have measured anything on the earth cable as that might not be the route the leakage was taking. A conductor leaking due to damp may not show anything on the main earth cable.

  • @steve83803
    @steve838033 жыл бұрын

    Metering cupboards are just that...for metering equipment, cut out, meter and DPI when fitted. Now getting more and more crammed with PV isolator and associated wiring but never (yet) found a CU in one! Surprised how the DNO fitted a 100A fuse in an 80A at best cut out.

  • @steve83803

    @steve83803

    3 жыл бұрын

    Consumer unit within 150mm of a live gas supply.......oooops!

  • @paulsutton5896
    @paulsutton58963 жыл бұрын

    The modern consumer unit is a thing of beauty.

  • @irqanonimous3278
    @irqanonimous3278 Жыл бұрын

    In Holland we have to use a splitter on the rcb when we have more then 1 incoming cable

  • @markshaw1413
    @markshaw14133 жыл бұрын

    Can you advise me how you undertake the maximum demand calculation. Would this property not be over 100a?

  • @christopherjones9570
    @christopherjones9570 Жыл бұрын

    Hi Jordan, love following your channel I have a question for you, why don't you like BG? I've fitted loads of BG boards and never had an issue my wholesaler stocks BG and Fusebox, twice I've used fusebox both times I've broken the lid clips, I've also noticed I have to cut the conductors quite short to fit them into the main switch and rcbo's, however I really like the blank mcb's they supply, keep doing the videos they're very entertaining and make me feel justified in taking pride in my work, there are lots of dodgy sparks in swansea.

  • @sosurko
    @sosurko3 жыл бұрын

    The dentist mirror you can get plastic ones. I use a plastic one its really handy

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Nice

  • @johnclapshoe8059
    @johnclapshoe80593 жыл бұрын

    Another issue having this armoured cable wired directly from the mains means there is no discrimination from the other circuits. In other words, you can't isolate it, even if the mains switch is open/off. I really don't like installing load centres (consumers units) under kitchen bench tops, as main switches are meant to be readily available. (Australian prospective)

  • @Vintagesoundz14
    @Vintagesoundz143 жыл бұрын

    Why didnt you connect one of the lives from the downstairs ring with one of the upstairs, same for neutral and earth then you would have one big house ring. solves the problem of having 4 cables in a breaker.

  • @HenryLoenwind
    @HenryLoenwind3 жыл бұрын

    No spares? I see 2 spares---if you replace the all breakers with rcbos. ;)

  • @glossamano1899

    @glossamano1899

    3 жыл бұрын

    And extra time involved to segregate the neutrals from the neutral bar.

  • @damienstewart4736
    @damienstewart47363 жыл бұрын

    That is a mantel cupboard, these are used in a lot of council properties or on conduit systems👍

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Thanks

  • @ItzD3fW1sH
    @ItzD3fW1sH3 жыл бұрын

    I'm on a looped supply and we managed to get 80amp fuse put in but that's the max (UKPN said as next door had 60 we were clear for the 80). Good news is the main supply comes into our house so any future work will be on her side and drive. Still think that's going to be a big big problem for the power networks in the coming years.

  • @HenryLoenwind

    @HenryLoenwind

    3 жыл бұрын

    It will only be a problem if people continue to upgrade to 100A "just because". A charger that's limited to e.g. 10A still can charge 12km/h or 120km overnight (10h). For most people who can park in their driveway every night that's more than enough. (Meaning they can charge to the full range of their car on normal days and only run into issues if they need the full range on two consecutive days.) Yes, a nice 32A charger will give you 380+ km/night each and every night, but how many people (aside from taxis and other business vehicles) actually need that? Many people seem to think they need to be able to charge their 600+km battery from completely empty to full in half a night at home. And if they drive 150,000km a year (600km*5days*52weeks) that's even true. But otherwise it's just not needed.

  • @nntpdump

    @nntpdump

    3 жыл бұрын

    @@HenryLoenwind overnight cheap rates from special "EV tariff" would suggest wanting the faster charge rates as possible

  • @jamesmillward6286
    @jamesmillward62863 жыл бұрын

    Love the dentist mirror, just ordered one 👍

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Cool

  • @evzenhedvabny6259
    @evzenhedvabny62593 жыл бұрын

    The weird leakage might be via gas or water pipe. On one of my jobs i found 2Amps running in a water pipe . Even when main circuit breaker was off.

  • @biaelectric9066
    @biaelectric90662 жыл бұрын

    15:13 - You have the lovely VDE allen keys there for show and then use the bicycle kit to do the job. Are you always missing the 2.5mm like me? I have three sets in the toolbag and no 2.5mm.

  • @kjd1972
    @kjd19723 жыл бұрын

    Can I ask, why no earth rod for this EV charge point? Thanks

  • @johnadams1976
    @johnadams19762 жыл бұрын

    I'd definitely have chosen to have a new hole and carefully fill the old one... Hopefully with some sanding of a brick somewhere, some like coloured dust could be used to patch

  • @somewaresim
    @somewaresim2 жыл бұрын

    Just wondering why the charger wasn’t obtained before installation date? Relying on on-the-day deliveries seems a bit risky.

  • @CrazySparkie63
    @CrazySparkie633 жыл бұрын

    You are the only person (that I know of) apart from me that calls it Londinium lol!

  • @johndufton9686
    @johndufton96863 жыл бұрын

    What tool do you use for stripping the tails?

  • @garethg2501
    @garethg25013 жыл бұрын

    Regarding the ring circuit, instead of connecting all 4 legs into the breaker, could you just Wago one leg of each ring together to form one big ring? Also do you have any tips for sizing (visually) meter tails? I struggle so much with this. P.S. You can actually get VDE "Dentist mirrors" lol

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Yeah that could have worked

  • @jamesfoxley6038

    @jamesfoxley6038

    3 жыл бұрын

    @GarethG, I hear ya man I have same issue! Everyone else seems to have better eyes 🤣, and know instantly haha

  • @nigellewis4686
    @nigellewis46863 жыл бұрын

    Luke uses contactum i like the colored switches

  • @ashmanelectricalservices4318
    @ashmanelectricalservices43183 жыл бұрын

    It's not an outdoor meter cupboard Jordan, it's a mantel unit and cupboad, very common in flats and tower blocks in London.

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Thanks, you can tell i'm not from London!

  • @ashmanelectricalservices4318

    @ashmanelectricalservices4318

    3 жыл бұрын

    @@artisanelectrics The previous installer should have just fitted another mantel unit, they're not that hard to come by. The whole stuffing glands on top of the consumer unit is complete gabage. On a side note, I probably would have waited till the EV charger to have been delivered before travelling all the way down to London, did you estimate for 2 days labour?

  • @mlugggy
    @mlugggy3 жыл бұрын

    thanks for the insightful videos. quick question, is it never possible to just use an existing, nearby socket and pull new wires through it?

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    No. An electric vehicle charging point has to be on its own individual circuit.

  • @mlugggy

    @mlugggy

    3 жыл бұрын

    @@artisanelectrics thanks, yes, a socket with its own individual circuit - theoretically, can its wires be replaced so we don't have to wire it above the tiles?

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Potentially yes if the wires are big enough to cope with the heavy load of an EV charging

  • @HeresMo
    @HeresMo3 жыл бұрын

    Couldn’t you join the legs from each ring together making a bigger ring with only 2 cables in the mcb? Return leg of front to outward leg of back?

  • @dariuszderecki635
    @dariuszderecki6353 жыл бұрын

    Garage BG consumer unit is very nice in my opinion. The bigger ones are nightmare

  • @luisbranco9260
    @luisbranco92602 жыл бұрын

    The box is original, not an outside box. It was fitted to council houses, I managed to get a consumer unit that was made for those boxes no longer made!!

  • @ashokpatel2700
    @ashokpatel27003 жыл бұрын

    Great video. Thank you. Andersen should really offer you some compensation. Why should it cost yo u money and your client the inconvience! I have seen your other videos on Zappy. What's your recommendation? Are you able to compare/contrast these EV chargers if you have not done so before please.

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Thanks yeah I think a comparison video would be a good idea

  • @ishkebab
    @ishkebab3 жыл бұрын

    For the ring, why not connect one original leg to the other ring leg and vise versa so you only have two cables entering the mcb, but the 2 rings have been extended to 1?

  • @elsdonsparks

    @elsdonsparks

    3 жыл бұрын

    the length of the making it one ring may have been to long for the max Zs ?

  • @ishkebab

    @ishkebab

    3 жыл бұрын

    @@elsdonsparks it’s on an rcd so Zs will not be an issue, not great relying on the rcd for fault protection but there you go.

  • @AndyK.1

    @AndyK.1

    3 жыл бұрын

    No advantage

  • @davidwynn6832
    @davidwynn68323 жыл бұрын

    Why is swa cable being used internally for the car charging circuit when you could run twin and earth to the isolation box and swa connected to it for the outside cable run? Then you could separate the earth at the box.

  • @dennisphoenix1
    @dennisphoenix13 жыл бұрын

    Fit a piece of trunking between the top of the board and the meter box , this covers the single insulation issue

  • @JOSHIMEOW
    @JOSHIMEOW3 жыл бұрын

    I would of doubled up on the lighting circuit mate

  • @TheChipmunk2008

    @TheChipmunk2008

    3 жыл бұрын

    Problem with that is that you lose the whole house with one trip

  • @MSGaddicts
    @MSGaddicts Жыл бұрын

    Random question... Why was amoured cable used since most of the install was inside of the property. Would standard 10mm be ok?

  • @pineappleroad
    @pineappleroad3 жыл бұрын

    for some reason, I can't stop thinking about the light switch cable at our house that has a soldered connection (literally) in the wall, where it is impossible to get to without tearing the wall open, and so the two light switches only have a single 3 core and earth cable going to them (the reason for this bodge was that the light switch needed to be moved from one side of the door to the other, as the door was being re-hinged)

  • @jimconnelly9245
    @jimconnelly92453 жыл бұрын

    am I wrong or is the supply providers isolator two seperate switches as apposed to one double pole isolator ?

  • @ashikarfan166
    @ashikarfan1663 жыл бұрын

    Nice bro

  • @muzikman2008
    @muzikman20083 жыл бұрын

    I feel your pain Jordan, nightmare jobs are what makes you wiser as you grow older... Trust me 😉 great video... The original install was a right bodge. Nothing surprises me anymore.

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Thanks

  • @delcat8168
    @delcat81683 жыл бұрын

    That look like the same original wall box as in our 1960s property... don't think it was ever an outside meter box. Maybe it wasn't "rewired" maybe it was just a new consumer unit put in? That would account for the scruffy wiring.

  • @MarkSaeys
    @MarkSaeys2 жыл бұрын

    I've seen several of your video's, great work Jordan! In most of your installs, I see you guys struggling with these tiny tiny distribution boards ... is that typical of the UK ? (Mine is 80cmx160cm by comparison. I live in Belgium) Even my secondary distribution board in the shed is bigger than the typical boards I see in your video's :-)

  • @JasperJanssen

    @JasperJanssen

    2 жыл бұрын

    I saw a video about a Belgian board, it was gigantic. It had like 5 rails of 16 units each or something. Here in the Netherlands typical is 220mm wide by 330 or 380 high with 2 rails of 12.

  • @carlvinjosephs4774
    @carlvinjosephs47743 жыл бұрын

    It’s time there is some sort of way to report and get electricians plumbers and other registered tradesmen and women to be accountable for bad bodge jobs. There is no accountability and compensation for homeowners. It’s terrible for what is quite an expensive and safety focused profession

  • @trevorpreston6351
    @trevorpreston6351 Жыл бұрын

    Hi again Just a thought why didn't you change all mcbs to rcbo plenty of space and contactum are cheaper than most and it could be left as is that would of been my suggestion Thanks

  • @keepthemhonest2
    @keepthemhonest23 жыл бұрын

    That's not an old outside meter box. It's an old style indoor meter box. It most likely had an integrated fuse board when first pin in and when there was a CU change they ripped it out (it would have been at the top)

  • @wolfe1970
    @wolfe19703 жыл бұрын

    6:50 that really messes with my OCD

  • @flori707125
    @flori7071253 жыл бұрын

    Dam i'm happy that i work in germany as electrician. 1 Phase oh boi i lough about that we got three 400 V means much smaller fuses. I don't wana go to much in detail but the pre installed stuff ist horrible. Next thing to close a hole wich goes straight to the outside of the building you have to seal it. It's a simple job. But so far your work is much better as this pre installed stuff.

  • @Deiphobuzz

    @Deiphobuzz

    3 жыл бұрын

    You have three 230v lines. Not three 400v. That would be what, 680v at the outlet? 😂

  • @flori707125

    @flori707125

    3 жыл бұрын

    @@Deiphobuzz you should go back to school measure between 2 phases and you habe a little bit under 400 v

  • @Deiphobuzz

    @Deiphobuzz

    3 жыл бұрын

    No you. Your phase voltage is always 230+-. Your line voltage is 380/400.

  • @thewhizard
    @thewhizard3 жыл бұрын

    under ther breaker box is the electric mter then under that the dno?

  • @michael_mouse
    @michael_mouse3 жыл бұрын

    ... DPD couriers are absolute shite... something always goes wrong them... Interesting video... subbed!

  • @artisanelectrics

    @artisanelectrics

    3 жыл бұрын

    Thanks for joining us!

Келесі