Troubleshooting Receptacles John Shook, Retired Disney Maintenance Manager: Plug A light into the receptacle not working, bang on wall above each receptacle and switch in the room to see if the light flickers, if not open each receptacle and switch and check the wiring. JS

Пікірлер: 237

  • @obsoleteprofessor2034
    @obsoleteprofessor20344 жыл бұрын

    I practically paid for my entire college with a little tool bag. Thank you Mr. Push-In receptacle!

  • @kenkondert8949
    @kenkondert89493 жыл бұрын

    Wow. I lost 5 lbs running up and down the stairsinto my basement checking and re-checking breakers to see why my outlets didn't work. This was the only video I saw suggesting to bang on the wall around the outlets to see if that would locate the problem and it worked like a charm !!! Thanks so much

  • @ericderosaphotographyvideo398
    @ericderosaphotographyvideo3983 жыл бұрын

    John, THANK YOU!! This was really fantastic. I had 3 daisy-chained outlets that were dead, no tripped breaker. I used your "tapping" the wall above the outlet method and found the loose wires. All fixed up, and more importantly, safe! Thanks again for sharing!

  • @jimlaird4348
    @jimlaird43484 жыл бұрын

    Hi John. Thanks for the video. I had several outlets dead. I verified there was voltage on the breaker output. I checked the outlet nearest the breaker and found a corroded neutral wire. Replaced the receptacle with a good 20 amp and all is now good. By the way credit to my wife for finding your great video.

  • @TheJediChef
    @TheJediChef5 жыл бұрын

    Hi John, you were my instructor at the NCE briefly. You defined the phases to me one day in the lab and that was the first time it actually made sense to me. I just want to let you know that I am still pursuing the electrical field and got into the IBEW apprenticeship. I really appreciate your knowledge and efforts at sharing your electrical wisdom.

  • @zlabfab487

    @zlabfab487

    3 жыл бұрын

    Hey Jason, are you still in your apprenticeship? If so how are you liking it so far?

  • @4usall181

    @4usall181

    Жыл бұрын

    @@zlabfab487; AA d

  • @freddygill3425
    @freddygill34252 жыл бұрын

    Bang on nearby outlets and switches!!! Fantastic logical, early and easy troubleshooting tip!!! So simple and easily overlooked!!! Thank you so much kind Sir!!!

  • @IamGoen
    @IamGoen2 жыл бұрын

    Your banging on the wall hack has saved me from having to call an electrician and from spending a few hundred bucks. Thanks!

  • @user-ju3od5gy5q
    @user-ju3od5gy5q4 жыл бұрын

    Thanks for your no nonsense excellent information. Your electrical 50 yrs knowledge/experience with this stuff is probably "only installed" in a minimum of 200 million existing homes in the US!! Please dont kick the bucket! You guys that have over 35 years experience can offer so much help to people out here who are trying to learn from honest experienced professionals and also trying to not get ripped off by so many crooks out here that seem to be around everywhere (Auto Repair Shops, Electrical, Plumbing, HVAC, Dentist, some Medical Doctors, you name it). What happened to honesty, and integrity? Thanks again for taking the time to help.

  • @ErnestAbell
    @ErnestAbell5 жыл бұрын

    I have hired John to do work on commercial buildings. He knows what he is doing and is very professional about everything. Thanks John

  • @trailhopper45

    @trailhopper45

    3 жыл бұрын

    Tom Henry would be proud...

  • @MrBritrider

    @MrBritrider

    2 жыл бұрын

    I have an outlet that one of the two receptacles (the lower one) displays an issue. When I plug in my hair dryer but don’t switch it on, I lose power on all other receptacles down the stream. If I plug the in the hair dryer in any outlet down the stream this behaviour does not occur. If I plug in the hair dryer into the questionable receptacle but nothing is plugged into any receptacle down the stream the dryer or any other appliance will work as normal. Does this sound like a faulty receptacle?

  • @askledhead
    @askledhead5 жыл бұрын

    Excellent video, straight to the point . No dragged out chatter , very informative . Thank you so much

  • @ManuelSanchez-tj5nu
    @ManuelSanchez-tj5nu5 жыл бұрын

    Greatly appreciated your knowledge and effort and most of all your noble spirit that's willing to share with all of us out here, thank you!

  • @OpaFPV
    @OpaFPV Жыл бұрын

    John, I just diagnosed a GFCI issue using your thoughtful and informative video. Thank you so much for sharing the experience from your career!

  • @mostlikelywedoitservices9743
    @mostlikelywedoitservices97435 жыл бұрын

    John, I like your laid back style. Great information. I never thought of banging to find the break. That would sure speed up finding it vs pulling outlets. Thank you, my friend.

  • @mikehamman7307
    @mikehamman7307 Жыл бұрын

    Wow. I just found this video. I had an outlet just stopped working for no apparent reason. It was powered by a light switch. I banged on the wall above the light switch and the outlet came on! Thank you so much!

  • @sangramsingh3591
    @sangramsingh35915 жыл бұрын

    Old school.. simply awesome...!!! Thanks for posting this.

  • @mgmmason8743
    @mgmmason87433 жыл бұрын

    Thank you John for your knowledge, very much appreciated. God bless.

  • @raymondklucik
    @raymondklucik3 жыл бұрын

    What a great suggestion. Thank you for passing this tip on John!

  • @scottromesburg7935
    @scottromesburg79355 жыл бұрын

    I've always gone to wise owls for knowledge....don't kick to soon! you're very much needed. Thanx!

  • @albey2k
    @albey2k3 жыл бұрын

    Thanks for sharing your knowledge, wisdom, and experience with the world. Four receptacles now working. Much appreciated! :)

  • @thundercrow1965
    @thundercrow19655 жыл бұрын

    Thanks for your clear, concise help. Much appreciated!

  • @McRaeStudios
    @McRaeStudios4 жыл бұрын

    Taping on the outlet worked for me. I found the scoundrel. Thank you.

  • @davidsowder319
    @davidsowder3192 жыл бұрын

    John, your knowledge and video helped me out today. I used a lamp and started tapping and in the second bedroom I found the culprit. Thanks so much.

  • @soyyo5828
    @soyyo58284 жыл бұрын

    As I was watching your video we both said at the same time OUT OF LUCK when wiring a custom home - LOVE YOU MAN - You are definitely a MASTER

  • @Hamfam93
    @Hamfam933 жыл бұрын

    Absolutely great video. Your explanations are done in simple terms and I love the practical advice. Even though I had a voltmeter I used a lamp like you suggested. It was way easier to see and I found the loose connection is another receptacle. Thanks

  • @jeraldgarner1636
    @jeraldgarner16364 жыл бұрын

    Great, very understandable and concise. John's advice is great!

  • @DIRTDIVER882
    @DIRTDIVER8825 жыл бұрын

    I think it would be AWESOME to have someone to pass down their knowledge & a whole life time of wisdom. How nice it must be for those who have parents gransparents etc

  • @alanroberts7916

    @alanroberts7916

    4 жыл бұрын

    My father knew so much stuff about relays, transformers, motors, , counters , air and hydrolic stuff. He worked on pinball machines for a while before WW2 then worked in linen supply machinery manufacturing in Chicago's downtown. He showed and taught me a lot of things. But much of it has become obsolete with time.

  • @SpotWorksLNC
    @SpotWorksLNC Жыл бұрын

    I am back from banging on my outlets with a lamp and it worked instantly. I had a string of 5 outlets that would go out periodically without tripping the breaker. I was about to call an electrician. Thank you very much!

  • @gazoomartian
    @gazoomartian4 жыл бұрын

    Dear John, thanks posting a very useful video. My daughter, who is also the owner of this house, plugged the vacuum cleaner in a power bar. When she turned the cleaner ON all the plugs in three bedrooms lost power. We found all circuit breaker in order. I opened up one dead plug to check the wiring. I had very small shock just like a pin pricking into skin. But now I am going to look at the 'stubbing' point of view today. Funny thing the GFCI breaker is still providing power to one of the plugs. If you wanted to kick the bucket you could have done years ago. Rest assure you are too old to die now like I am haha Jamil in Edmonton, AB, Canada

  • @mvred100
    @mvred1004 жыл бұрын

    John, I really liked your video and appreciate you sharing your knowledge of the electrical trade.

  • @johnallison5712
    @johnallison57125 жыл бұрын

    Thanks John - the video was very helpful. I was able to identify which outlet had a problem by plugging the lamp in and tapping on the outlet!

  • @glenmartin2437
    @glenmartin24372 жыл бұрын

    Thank you, again. Glad this video is still available.

  • @KModica11
    @KModica113 жыл бұрын

    Thank you very much! Great advice and more important - clearly and simply explained. Saved me a lot of time and aggravation on my 4th of July weekend. Thank God for people like you sir. Happy Independence Day.

  • @johnpotter5327
    @johnpotter53272 жыл бұрын

    John just saved me a lot of money. I followed his directions and discovered our outdoor lights on our RV had moisture issues and it kept tripping the GFI on the kitchen island.l after unloading the GFI inside the RV.. and remembering he said it could be attached to someplace weird, I unplugged the cord attached to the underbelly socket servicing the deck lighting --and that was it!

  • @stantaur3
    @stantaur36 жыл бұрын

    Thank you for a great explanation and demonstration of the diagnostics for when your breaker might not be tripped, but you have an outlet that's not working (likely because of push-in connnector fault).

  • @glenmartin2437
    @glenmartin24375 жыл бұрын

    Thank you. This is a time saver.

  • @deezzbeatz8983
    @deezzbeatz89835 жыл бұрын

    Thanks for the knowledge and your wisdom ,it's really what I needed to know ,these other guys where giving up nothing but worthless information,, appreciate you💥💪💥

  • @tm71100
    @tm711005 жыл бұрын

    Thank you very much John , you just fixed my problem.

  • @houseofwisdom3579
    @houseofwisdom35794 жыл бұрын

    Thank you for passing your knowledge along.

  • @es2194
    @es21943 жыл бұрын

    Thank you Mr Shook. Excellent video. I’ve got a game plan now to tackle my issue.

  • @caltax9033
    @caltax90337 ай бұрын

    John, Brilliant video! I have been chasing a bad receptical for a week and you solved my problems. Thanks very much and I am now a subscriber.

  • @montag4516
    @montag45164 жыл бұрын

    Another way, besides a lamp, to know you've turned off the correct breaker for the outlet you're working on is to plug a radio or stereo into it and turn it up. You'll hear when you've cut power to the correct outlet/circuit. This saves you from repeatedly walking back and forth from the outlet area to the breaker box.

  • @geraldhenrickson7472

    @geraldhenrickson7472

    2 жыл бұрын

    I think you missed the point. Finding the correct breaker is an entirely different matter. In this episode we are locating the guilty connection that plagues us.

  • @jerryross5423
    @jerryross54234 жыл бұрын

    Thank you! I had a number of outlets go dead, was getting voltage, but nothing would work when plugged in. I banged the wall over the outlet I had originally thought might be the culprit, but wasn't sure - and it worked. And it's a back stab outlet just like you said it would be!

  • @aaronmaturino5572
    @aaronmaturino55726 жыл бұрын

    Thanks for the quick to the point lesson

  • @Saurous3098
    @Saurous30982 жыл бұрын

    Great stuff...explained like we are in the same room.

  • @emeraldcity9574
    @emeraldcity95743 жыл бұрын

    Thank you for your insight and experience. I was able to make the repair.

  • @theresamoore7634
    @theresamoore7634 Жыл бұрын

    Thank you very much for the video !! Take care 💗

  • @usntheboy1
    @usntheboy15 жыл бұрын

    Excellent video! Saved me a couple hundred dollars! Thanks you so much!

  • @chenlaoding
    @chenlaoding5 жыл бұрын

    Thanks for your very educational and practical videos

  • @phenix1307
    @phenix13074 жыл бұрын

    Thank you Mr. Shook, your advise help me.

  • @martingelter8064
    @martingelter80642 жыл бұрын

    Thank you for this video! I was able to identify two bad outlets using the "tapping" method. I replaced them and now the entire circuit is working.

  • @RiverPlaid
    @RiverPlaid5 жыл бұрын

    Thank you for sharing the valuable insight you have.🌸

  • @MommaheartsMakeup
    @MommaheartsMakeup4 жыл бұрын

    You've been a great help. Thank you so much!!!!!!!!!!!!!!!!!

  • @burritobeserro
    @burritobeserro8 ай бұрын

    I fow your advice after a day changing outlets find out was in my office one outlet was no good with intermittent connection. Thank you John

  • @johnr.6029
    @johnr.60292 жыл бұрын

    Very good. Now I can go to work fixing my problem receptacles. Thank you.

  • @Wayman_Simmang
    @Wayman_Simmang2 жыл бұрын

    Thanks John! Great tips!

  • @dexstjok1
    @dexstjok13 жыл бұрын

    Thank you Sir. Great video.

  • @carsonestes2763
    @carsonestes27634 жыл бұрын

    Your awesome great video to watch with some experience thank you very much sir for the time you and effort you put in to it

  • @martyvanord984
    @martyvanord984 Жыл бұрын

    Thank you sir. I subscribed at the tap the wall tap tip. There is just no substitute for long term hands on expierience that has had time to grow to the point that it becomes part of the intuition of the diagnostic procedure. Sadly when I ask after life time expierience, all to often I get the reply that they were amazing but the guy that I knew retired.

  • @ianmitchell4662
    @ianmitchell46626 жыл бұрын

    Fantastic advise John. Thank you for passing on your knowledge. Had issue where suddenly 2/3 of receptacles/lights on branch circuit stopped working. This video had all the information I needed to troubleshoot and find the issue. Ended up all receptacles were push in connected and one had burned up. All the issues you covered were found, including discovering that the one branch circuit has 3 bedroom lights and 9 receptacles. House was built in 1968 so maybe they could get away with that back then. For now I have replaced the bad receptacle and have reconnected all the other receptacles using the screw terminals rather than push ins.

  • @alwaysforeigner

    @alwaysforeigner

    5 жыл бұрын

    I had the same problem and it turned out that a cable was loose in a bathroom socket, Now is working properly

  • @gl8585
    @gl85854 жыл бұрын

    I had an outlet that stopped working in a bathroom in the back of the house, it was a terminal outlet in the wiring, replaced the outlet, still no current, checked all the wires, all good, so went to breaker panel, all was good, on my way back into the house noticed my solar hot water LED control panel was off. It was plugged into a GIF outlet on the garage wall, GIF outlet had tripped, reset and solar control panel came on and the outlet in the back bathroom now works! So the information about daisy chained outlets was very helpful.

  • @jamesmarshall8373
    @jamesmarshall83732 жыл бұрын

    I'm laughing at this video because I discovered this trick 2 weeks ago purely by accident! A light in my finished basement wouldn't turn on and a few of the nearby outlets were only registering 50 volts. All of them had the push-in wiring with cheap receptacles (had problem with them on other circuits so I've been replacing them and using j-hooks). Replaced all the receptacles and still no light, low voltage. Magically, the light started working again a week or two later. Because of another project I have to do, I had to remove an unfinished (previous owner) corner cabinet that was situated physically between the outlets and the light switch. When I took the top of the cabinet off, I spied another outlet in the wall within the cabinet. As I was pounding a pry bar between the cabinet and the wall just above that outlet, the light went out! Banged the wall above the outlet again, and the light went back on! After removing the cabinet I checked the outlet out and found in addition to the line and load wires (all just push-ins) wires to the light switch j-hooked to the outlet and the hot line to the outlet just sliding in and out of the push-in with no resistance. Replaced the receptacle, pigtailed the load and light switch wires and j-hooked the four to the receptacle. Long story short, I can testify that your advice works!

  • @barbarocaballero9596
    @barbarocaballero95964 жыл бұрын

    Thank You very for the feedback!!🙏🙏

  • @jamescc2010
    @jamescc20102 жыл бұрын

    Always great to learn , tricks and such, from long time experience. POT LUCK. Thank you

  • @josemorgan4524
    @josemorgan45245 жыл бұрын

    Great Video..This Info Helped me fix my Problem ..keep up the good work👌

  • @tonyb4887
    @tonyb48874 жыл бұрын

    Thank you boss, this vedio is very helpful it's as clear as day light .

  • @TheShop.
    @TheShop.5 жыл бұрын

    Great information on testing an outage. Thanks

  • @anilbharat
    @anilbharat5 жыл бұрын

    Thank you! I fixed receptacles problem in my home office...

  • @sergevip
    @sergevip4 жыл бұрын

    Thank you John!!! 👌🏼

  • @cortaza007
    @cortaza0074 жыл бұрын

    Thank you for sharing your time and your knowledge. I recently move to an apartment and I have some receptacles they don’t work.

  • @jf5016
    @jf50162 жыл бұрын

    Great way to check your pacemaker! An idiot light! Love it!

  • @kattiablanco4611
    @kattiablanco46113 жыл бұрын

    Thank you! Very helpful!

  • @patcupolo9274
    @patcupolo92745 жыл бұрын

    A ton of information from. A professional, not afraid and sure enough of himself, to pass on his knowledge

  • @tudocervera3764
    @tudocervera37642 жыл бұрын

    WE THANK YOU SIR FOR YOURE KNOWLEDGE..

  • @davidparker2173
    @davidparker2173 Жыл бұрын

    Thumbs up. Thanks. I got lots to learn. I do though know how to use my "idiot light". Got lots that don't work. Thankfully there is a Square D Homeline service panel with AFCI breakers protecting me till I figure it all out.

  • @howardlovecraft750
    @howardlovecraft7505 жыл бұрын

    It doesn't take long watching a video to know if the person is a professional. Thanks for the info.

  • @thirdeye7611
    @thirdeye76112 жыл бұрын

    Nice of you. Thank you.

  • @chhengchhay7300
    @chhengchhay73005 жыл бұрын

    I’m truly Thank you 🙏 so much sir

  • @chhengchhay7300

    @chhengchhay7300

    5 жыл бұрын

    Thank you so much for sharing your experience or your knowledge to all of us .

  • @alwaysforeigner
    @alwaysforeigner5 жыл бұрын

    Great video, thanks for share

  • @geraldhenrickson7472
    @geraldhenrickson74722 жыл бұрын

    Thanks John. Will try the BOW technique to locate my bad outlet/switch that causing my issues.

  • @hotwheelmanraven2289
    @hotwheelmanraven22894 жыл бұрын

    That is a very good idea. I will try that. I have one room that's got four circuits not working and it's driving me crazy panel says all the breakers are on. So I will try that today. I thank you very much. I wish you lived close I had to come over here and fix the damn thing.

  • @entoletao
    @entoletao10 ай бұрын

    Fantastic Info

  • @kevinvt4174
    @kevinvt41748 ай бұрын

    John, You should tell people the correct way to wire the plug after you find the problem. If you have 2 romex wires in your box add a pigtail to each wire - Hot, Neutral & ground then run your pigtails to the plug so if the plug burns out, breaks or anything else it does not effect the plugs downstream.

  • @geocapistrano4364
    @geocapistrano4364 Жыл бұрын

    Thank you 🙏🏽

  • @MichaelPickleball
    @MichaelPickleball3 жыл бұрын

    Thanks for the sound advice. After swapping out 2 outlets on a circuit and no success. I decided to search for answer on KZread. I had my voltage tester plugged in and banged on all the plates and watched for the tester light to go on. It was the 3rd one that I had not swapped out. Took out the socket, had fired wires. Replaced it and all's good.

  • @JohnShook

    @JohnShook

    3 жыл бұрын

    kzread.info/dash/bejne/e4domKmYh9Kxh6Q.html John Shook

  • @dallasmosley7480
    @dallasmosley74803 жыл бұрын

    Thank you for the video

  • @seanprice7729
    @seanprice77294 жыл бұрын

    Just playing you’re doing great guy

  • @astartar5782
    @astartar57826 жыл бұрын

    Thank you, sir🙏🏻🙏🏻🙏🏻

  • @ogearbox6132
    @ogearbox61322 жыл бұрын

    John, neat name Shook Electric lol. I have a 15 yr old house with 6 receptacles in our bedroom where the top receptacles is controlled at the wall switch. Last week the top ones went dead. No tripped breaker no sparks. Today I changed two receptacles and still the same I’ll try the bang on he wall trick and see what turns up thx.

  • @timothygorman6972
    @timothygorman6972 Жыл бұрын

    Thank you Sir

  • @KevinCoop1
    @KevinCoop15 жыл бұрын

    John, As an electrical design engineer that worked for electrical contractors for over 35 years, although I would not design circuits this way, for general purpose receptacles the NEC allows 10 receptacles on a 15 amp breaker and 13 receptacles on a 20 amp breaker. The information is as follows: receptacles are considered 1.5 amperes each for load purposes, this is also considered a non continuous load. So fully loaded would be 15 / 1.5= 10 receptacles. 20 /1.5= 13.3 so 13 receptacles. As I said, this is NEC, not what I would design.

  • @hornetd
    @hornetd4 жыл бұрын

    This may seem a minor quibble but the National Electric Code forbids the installation of 20 ampere receptacles on 15 ampere circuits. That's because the 20 ampere receptacle will except both a 15 ampere plug and a 20 ampere plug. 20 ampere plugs are installed on equipment that will draw more than 15 amperes but not a whole lot more. Circuit breakers open much more quickly on a dead short than they do on overloads. While the thermal sensor of the circuit breaker is getting hot enough to trip the breaker damage may occur on some weak point on the circuits wiring. It may not be enough damage to prevent the receptacles and luminaires; which is the code term for lighting fixtures; to continue working but it may well be enough to cause a problem later. High quality receptacles are available in the fifteen ampere receptacle pattern. 15 ampere receptacles will not allow a 20 ampere plug to be inserted so you have less likelihood of a damaging overload. I agree completely that the back entry screw clamping receptacles are superior in many ways to side wired binding screw terminals. I also agree completely that any other type of terminal is superior to the back wired spring terminal terminals. Spring contact terminals have a far higher rate of failure per 100,000 installations than either of the 2 other types of terminals. -- Tom Horne

  • @johnt890
    @johnt8903 жыл бұрын

    Great instruction

  • @ernthun2
    @ernthun25 жыл бұрын

    Thanks john

  • @carlosmartinezreborned6403
    @carlosmartinezreborned64035 жыл бұрын

    Awesome video, great knowledge, and I appreciate you passing all of this information on before you kick the bucket my friend.

  • @skipd9164
    @skipd91644 жыл бұрын

    Wow loved your advice and I'm hoping it will help me. I have a good knowledge of electrical systems but not an electrician. I'm an appliance repair tech that helps friends save money. I'm going to put this to use and hope to reply with a thank you.

  • @chaos8327
    @chaos83275 жыл бұрын

    John! I installed new ceiling fans in the bedroom that previously had not had any light fixtures wired? The circuit box was wired to the plug and the switch controlled one half of the plug. After wiring new fixture to the switch, i got done weird results and the fan's lights wouldn't come on. And the lamp plugged at the wall controlled the fan. So I replaced the plug and now the outlet has power but the ceiling fan does not! What did I do wrong? Should I have wired the fan to the outlet?

  • @KENNETHEMorse
    @KENNETHEMorse3 жыл бұрын

    Very helpful

  • @gregorymorris8343
    @gregorymorris83435 жыл бұрын

    Awesome video, don't kick the bucket anytime soon thanks for your expertise.

  • @ottoroth9377
    @ottoroth93775 жыл бұрын

    Great info from one old guy to another. What I do when I rewire either for remodel or new work..I put each room on its own circuit and I supply each room with a single 20 amp circuit along with the 15 amp run. Makes it easier to troubleshoot and see which breaker goes to what...the 20 amp is for a space heater and will have a single round plug. I cannot stand a wiring job connecting two or three rooms, or sharing an outside outlet. Also...all outside outlets I install are 20 amp and separate from anything else. Bathrooms too..a 20 amp. I also keep the proper outlet according to the amp circuit I run. Another point is I use Insure connectors (because I can see the connection where in a wire nut, you cannot) and run a separate pig tail to the outlet, that way the outlet is not being stressed

  • @jenko701
    @jenko7016 жыл бұрын

    I like to pigtail behind the outlet so the outlet it self is never Carrey’s pass through current. Great video.

  • @1575murray

    @1575murray

    4 жыл бұрын

    That is good practice but is more time consuming. Builders are very cost sensitive so in many places I have seen the push in terminals used as it saves a lot of money. If I replace a receptacle in that situation if I don't pigtail the new one I use the side screw terminals as they are more reliable. Also he talks about using 20 amp receptacles on a 15 amp circuit what he really means is 15 amp receptacles rated to pass through 20 amps which is available on commercial grade receptacles not inexpensive residential grade ones. It would be an electrical code violation to use a receptacle which can accept a 20 amp plug on a 15 amp circuit as using a load which exceeds 15 amps will overload the wiring and trip the circuit breaker.