Piping Engineering : Valve Testing - body, seat, backseat & seat pneumatic

G. S. Samanta : Engineering & Educational

Пікірлер: 15

  • @sen-ow7ub
    @sen-ow7ub Жыл бұрын

    Very nice video you have explained with very basic simple practical explanations I have never seen such a clear video with such explanations. in future we all request you to keep sharing such excellent video.

  • @jose941978
    @jose941978 Жыл бұрын

    Truly detailed and precise explanation

  • @heshammatoug4860
    @heshammatoug4860 Жыл бұрын

    Hi Gouri We need you to explain to us how to inspection test plan for valves Thanks 🙏

  • @CarlosAndresRomeroToscano
    @CarlosAndresRomeroToscano Жыл бұрын

    Excelente video. Muchas gracias

  • @rajeshmavia5424
    @rajeshmavia5424 Жыл бұрын

    Thank you so much sir.. belated teachers day wishes. For bigger size valves, how we lift weight and test will be done in larger test benches ah sir?

  • @aghilmoghbeli7626
    @aghilmoghbeli7626 Жыл бұрын

    Very good video

  • @akurathinaveenkumar
    @akurathinaveenkumar6 күн бұрын

    Can you please send the drawing of air-hydro test bench... please

  • @rajeshmavia5424
    @rajeshmavia5424 Жыл бұрын

    Pneumatic pressure 5.5 bar is mandatory sir? Or we can go beyond or reduce this pressure level

  • @ajay_constantine
    @ajay_constantineАй бұрын

    Sir during the seat testing shouldn't the valve be in horizontal position? Because even if there is any tiny leak which is in the acceptable range we could identify it easily?

  • @gourisankarsamanta7670

    @gourisankarsamanta7670

    Ай бұрын

    Yes

  • @raviv9157
    @raviv9157 Жыл бұрын

    Dear Sir, Why gland bolts are loosed incase of hydro testing which is not going to do when valve installed in the line in the industry?

  • @gourisankarsamanta7670

    @gourisankarsamanta7670

    Жыл бұрын

    Gland bolts are loosened only during backseat testing to ensure that there is no leakage through the gland so that at site when the valve is under operation, gland packing can be removed or replaced without closing the valve.

  • @shika-ri
    @shika-ri5 ай бұрын

    Sir , as per API 598 during shell test valve shall be partially open but your valve is fully open , can you explain why?

  • @gourisankarsamanta7670

    @gourisankarsamanta7670

    5 ай бұрын

    During valve body or shell testing, valve can be kept partially open or full open. Requirement is, valve body and bonnet should be pressurize together.