No video

PID REX C100 temperature controller contact connection

A proportional-integral-derivative controller (PID controller or three term controller) is a control loop feedback mechanism (controller) widely used in industrial control systems and a variety of other applications requiring continuously modulated control.
You can buy rex c100 in aliexpress very cheap
got.by/1g435s
got.by/1g432h
KZread Partner Program
www.scalelab.com/apply/agankev...
Watch video together
PID REX C100 temperature controller contact connection
• PID REX C100 temperatu...
Thank you for watching! Like, Comment, and Subscribe

Пікірлер: 50

  • @ernestoaranasanchez1537
    @ernestoaranasanchez15374 жыл бұрын

    Excelente vídeo y gran explicación saludos desde la CDMX (México)

  • @dparham
    @dparham3 жыл бұрын

    Great strait forward Video! :) im adding PID to a countertop comercial pizza oven that had manual controls!

  • @sorinvisan6871
    @sorinvisan68715 жыл бұрын

    Thank you, I wired my C100 as shown by you and works properly

  • @SuperJawadkhanlodhi

    @SuperJawadkhanlodhi

    5 жыл бұрын

    bro what is max set temperature?

  • @johnrizzato9192
    @johnrizzato91923 жыл бұрын

    Wow, great narration!

  • @alexandrevancleeff3148
    @alexandrevancleeff31484 жыл бұрын

    Thank you !! I was very skeptical that this little plastic box can receive 110volt input.

  • @titojrfordan576
    @titojrfordan5763 жыл бұрын

    nice video it will help me now to fix my own pid controller on my powder coating oven.

  • @OnnieKoski
    @OnnieKoski4 жыл бұрын

    This worked great making my solder reflow oven!! Thank you so much!

  • @adeosunfirstman1246

    @adeosunfirstman1246

    3 жыл бұрын

    Thanks for the video, Can I use AC to AC solid state relay instead of DC to AC ?

  • @OnnieKoski

    @OnnieKoski

    3 жыл бұрын

    @@adeosunfirstman1246 I have no idea. Sorry :-/

  • @TeacherBrunoOneil
    @TeacherBrunoOneil5 жыл бұрын

    My friend, the circuit you created and the circuit you showed from google are slightly different.. but what you did is the correct way. Ive been checking around videos like this to make sure that the controlling unit is capable of generating DC for the SSR. I couldn't find this info at EBAY.

  • @TeacherBrunoOneil

    @TeacherBrunoOneil

    4 жыл бұрын

    @irmux skeptic thank you, I already found it.

  • @devanand.m1763
    @devanand.m17636 жыл бұрын

    Tq tq tq for our success

  • @anacgartenimechtennorden7350
    @anacgartenimechtennorden73503 жыл бұрын

    in germany it`s not allowed to connect PE with N. Also RCD dont like it.

  • @btomas225
    @btomas2255 жыл бұрын

    If you wire the A/C 220v to the SSR as shown in the schematic it will blow your house circuit breaker (hopefully). It takes the two lines and shorts them together via the SSR. Not good!

  • @dali2747
    @dali27476 жыл бұрын

    bravo :)

  • @edgarasvas
    @edgarasvas2 жыл бұрын

    So, what controls ssr here if you connect both out wires to the net as input to controller? This will be short circuit directly to the electric source

  • @donjuan7427
    @donjuan74276 жыл бұрын

    thanks very much for teaching

  • @jorgepetrol
    @jorgepetrol2 жыл бұрын

    Prezado companheiro, boa tarde, tudo bem? como faço para controlar a taxa de aquecimento do Rex C100 , preciso aquecer a 190 °C , pois vejo que o aquecimento e muito rápido, gostaria de reduzir essa taxa pela metade , isso é possível?

  • @gayanwaidyaratne5894
    @gayanwaidyaratne58943 жыл бұрын

    Hi, I'm using the same setup to control the temperature of a smoker. But for some reason the fan permanently stops at the set temperature. But it doesn't switch on automatically when it goes below the set temperature. Any idea what I'm doing wrong? Also if I try to reconnect the output cable from the relay it will start to switch on the fan again. Any help please

  • @habtamusium8646
    @habtamusium86463 жыл бұрын

    thanks !

  • @sumanpalinepali3182
    @sumanpalinepali3182 Жыл бұрын

    Nice

  • @Angel1B79
    @Angel1B794 ай бұрын

    Hi, why your lamp is off when you turn on the pid and switched off when you get the temperature? Shouldn't be the opposite way?

  • @andeyocalientemart1379
    @andeyocalientemart1379 Жыл бұрын

    hi can you say me what parameters are on menu set+up buttoms after 3 seconds?

  • @henrikhansen1023
    @henrikhansen10233 жыл бұрын

    Have you any idea how inaccurate the temperature measuring is with this product? Tin melts at 449,42 °F....and according to the BERM REX C-100 the temperature was at 298.4 °F when it did....some tolerance, huh?

  • @stephenho6007

    @stephenho6007

    2 жыл бұрын

    maybe you are using the wrong thermo couple?

  • @marvinloka1246
    @marvinloka12464 жыл бұрын

    Hello what's this thermostat accuracy?

  • @KrishnaSingh-gz5zl
    @KrishnaSingh-gz5zl5 жыл бұрын

    Pid can use for galley hot plate for 4 kW load

  • @TeacherBrunoOneil

    @TeacherBrunoOneil

    5 жыл бұрын

    yes, but your SSR will have to be more powerful... 4000w goes up to 40 Ampers, most SSR ( relays ) are coming only for 25A. The SSR will need a heatsink to discipate the heat, ok? Your wire will invitably need to be way thicker than that of the video.. if I'm not wrong, 40A will require a wire of approximately 6mm ( considering the ( hot plate ) is not really far away from the SSR. You need a little understanding of how the relay works to see that the load is not going through the controller.. The temperature controller is only turning the relay on and off according to the temperature limits you set.. the load is going through the relay ( SSR ) that is why it will need to resist the 40 ampers that your hot plate will take... got it ? so, good end connectors, soldering preferably, thick wires, a good heatsink ( and if you can use a cooler to give support to the heatsink of the SSR ) and you are good to go.

  • @stephenho6007

    @stephenho6007

    2 жыл бұрын

    @@TeacherBrunoOneil He might be using 220V, 4000W is only about 20A in this case.

  • @TeacherBrunoOneil

    @TeacherBrunoOneil

    2 жыл бұрын

    @@stephenho6007 that's true.

  • @jeanpapinou5541
    @jeanpapinou55415 жыл бұрын

    wire blue for + ????

  • @jbiliHacker
    @jbiliHacker9 ай бұрын

    what are they eating? can you please tell me? 0:07

  • @user-qq8bp9rc2m
    @user-qq8bp9rc2m4 жыл бұрын

    بكام وفين

  • @SanjayGupta-6264
    @SanjayGupta-6264 Жыл бұрын

    Give a solution

  • @md.aliakbar5646
    @md.aliakbar56464 жыл бұрын

    dear honourable madam, I'm talking from Bangladesh (South asian country). I want to you,please you use Bengali or English language. Because, this language is very complex....!!!

  • @viz8390
    @viz83905 жыл бұрын

    Depressing music

  • @melodysmootty
    @melodysmootty4 жыл бұрын

    งงจาด

  • @nolinicolas4237
    @nolinicolas42373 жыл бұрын

    Gudday sir. How about i will use for cooling sir, all i need is 16-17 C means, 16C below it will turn-off and if 17C up it will turn-on. I will use as a switch(i will pluge my refrigerator) for restoring my pig semen. Thank u and God bles

  • @namikagasiyev8013
    @namikagasiyev80135 жыл бұрын

    Men mütləq nəsə elemeliyem

  • @deepakkumarkatariya4988
    @deepakkumarkatariya49885 жыл бұрын

    Please Hindi ma samjha kar video banayo

  • @SanjayGupta-6264
    @SanjayGupta-6264 Жыл бұрын

    Sv- blink at

  • @marcsaveursdesdeuxsud5120
    @marcsaveursdesdeuxsud51203 жыл бұрын

    No blue fou relay ! Blue = neutral only !