Pico Scope 7 What is a waveform sample interval? Why is it important? What is the correct setting?

Автокөліктер мен көлік құралдары

Pico Scope 7 What is a waveform sample interval? Why is it important? What is the correct setting? Learn all this and more.

Пікірлер: 13

  • @alexismarcyting5340
    @alexismarcyting5340 Жыл бұрын

    nice tutorial i watched all your picoseries video. would you mind if you could make a video about reference waveform? if you’d like to.

  • @DrivelineMaster

    @DrivelineMaster

    Жыл бұрын

    Reference waveforms and meters are on my list. I have just been to busy lately to get back to making more videos.

  • @Yawasapyaahla
    @Yawasapyaahla Жыл бұрын

    @DrivelineMaster how do I reach you directly?

  • @DrivelineMaster

    @DrivelineMaster

    Жыл бұрын

    drivelinemaster@gmail.com

  • @mandytuning
    @mandytuning8 ай бұрын

    Not sure if is cause later version of software but using your example of 1ms/s sample and 20 ms/div gives me sample interval of 41us. Sample interval only stays at 1us when ms/div is over 100.

  • @DrivelineMaster

    @DrivelineMaster

    8 ай бұрын

    Go to time stamp 7:44 in the video. Change your sampling mode from Buffered to Sample Rate. then your sample rate will be stable across multiple time sweep settings.

  • @mandytuning

    @mandytuning

    8 ай бұрын

    @@DrivelineMaster thats exactly how i have it, but from 100ms/div up, its stay in 1us sample interval. When i go under 100msdiv,it start changing, i tried reinstalling the software and didn't help,thanks for your response

  • @DrivelineMaster

    @DrivelineMaster

    8 ай бұрын

    This is very strange. I just downloaded the most recent early release of Pico Automotive and double checked. 1us sample interval stays consistent all the way from 5us/div all the way to 20s/div . I'm doing this in demo mode today but I believe I had my scope connected to a simulator board when I made the video. Try resetting everything by going to Settings and click on Factory under Start-up settings. close and reopen Pico 7. Return to Settings and change Start-up settings to User. Return to the time base Setting and reset Sampling to "Sample Rate, Custom, Target Number of Samples to 1M, Progressive mode to 200ms/div and Previous Progressive Waveform Off. Then test the sample interval again and let me know.

  • @mandytuning

    @mandytuning

    8 ай бұрын

    @@DrivelineMaster tried and same issue, funny thing it works on demo mode,. Also,it doesn't have the custom ,low , high for the sampling. I installed the software in another laptop and exact same issues, I wonder if the scope have some firmware issues. Any way for factory reset?

  • @DrivelineMaster

    @DrivelineMaster

    8 ай бұрын

    Hmm, Which Pico scope do you have because it could be scope hardware that is causing these limitations. I will connect my scope later today and test it again.

  • @nickayivor8432
    @nickayivor8432 Жыл бұрын

    My Mentor DrivelineMaster 👍 PRODIGY DrivelineMaster From Nick Ayivor from London England UK 🇬🇧