On The Bench: Coleman 249 Single Mantle Kerosene lantern

This isn't an ordinary 242, oh no. This is the Kerosene version, the 249. Let's take it apart and see what makes it tick!

Пікірлер: 19

  • @chatbotdiaries
    @chatbotdiaries5 ай бұрын

    I have a 249 that I found as a kid, in an old hurricane destroyed cabin waaaaay out in the woods along the Texas Guld Coast 50+ years ago. I sure wish I'd had great videos like this when I was leaning to fettle! Awesome job.

  • @willssmallenginerepairllc5060
    @willssmallenginerepairllc5060 Жыл бұрын

    Excellent as usual! One of my wants someday!

  • @wdglockandroll
    @wdglockandroll Жыл бұрын

    You make some great videos! I’ve never seen that style lantern before. I’m going to keep my eyes open for one at the barn sales now. Have a great week.

  • @woodsmn8047
    @woodsmn804711 ай бұрын

    for years I used a Colman single mantle white gas lantern for doing my chores .. milking my cow etcetera .. I never knew there was a kerosene version ... I loved my lantern and wouldn't have traded for anything .. but now you have my curiosity up ..humph ..?

  • @gasunderpressure9131

    @gasunderpressure9131

    11 ай бұрын

    Coleman also made a big single in the 237 (500 candlepower) and also current production 639. They are a bit more of a production to light with the preheat cup, but they run fantastic and nowadays Kerosene is cheaper than Coleman Fuel.

  • @alexkq2h770
    @alexkq2h770 Жыл бұрын

    I just wanted to make a comment about the “soft start” method. I believe it’s a safer way to pre heat the generator. With no pressure in the lantern and fuel valve open, a generator explosion is unlikely to occur should the cleaning needle be left in the up position or another blockage that causes fuel pressure to build up during the preheat time. There are at least 2 or more videos on KZread in which a kerosene generator exploded during preheat. In one instance the cleaning needle was left in the up position and in the other the brass was softened by excessive heating and quenching cycles during generator cleaning. I always use the soft start method to light my 237’s and 249’s. Keeping the fuel valve open with no pressure in the tank is definitely safer way to preheat IMHO.

  • @gasunderpressure9131

    @gasunderpressure9131

    11 ай бұрын

    Fair enough, and one should absolutely do what they are most comfortable with.

  • @curtiscf1986
    @curtiscf198611 ай бұрын

    My 249 has lost quite a bit of nickel from its fount as well. My theory is that the additional heat has something to do with that. Kerosene burns hotter, and the fount on mine gets quite hot. Mine pushes the 24a mantle beautifully.

  • @gasunderpressure9131

    @gasunderpressure9131

    11 ай бұрын

    Some lanterns just got a really thin nickle coating. This one's in nice enough shape that it might be worth sending it out to be replated. My fount also gets suprisingly hot. Usually don't experience that with the 242's. The 24a mantle just hung down way too far and ended up resting on the cup. Then of course the #21 just looks tiny on there. Oh well.

  • @LanternLooney
    @LanternLooney Жыл бұрын

    Looks great! I just got my first 249 two days ago. I wonder if those little flare ups at the end could be some moisture in the old fuel?

  • @gasunderpressure9131

    @gasunderpressure9131

    Жыл бұрын

    Maybe? It's a BIG generator compared to a 200a, so that's a fair bit of mass to heat, including the burner head. Yellow flareups usually mean liquid fuel is getting through, and I will say that after letting it run for a few minutes after I stopped filming, it stopped doing that. Just weird as my 237 also has a large gen, and it just starts and runs, no flareups.

  • @steveseattle6791
    @steveseattle67919 ай бұрын

    Great vid as always! Out of curiosity, do you have a fuel explainer video? I have been running the white gas lanterns for years, and have some from the 60's running great. But I have a bran new Coleman Kerosene lantern and It's running poorly after only 25 or so hours off Klean-Heat. I would love to know more about fuel options for these and the older ones (next on my list to find)

  • @gasunderpressure9131

    @gasunderpressure9131

    9 ай бұрын

    Hm, no I don't, but that's a good idea for a video coming up.

  • @ronnietucker4943
    @ronnietucker494310 ай бұрын

    With the24a would it help to tie the mantel above the burner cap

  • @gasunderpressure9131

    @gasunderpressure9131

    10 ай бұрын

    That's a good suggestion. I'm just a bit puzzled the 24-A didn't work that well, as they're pretty much a direct replacement for the no longer made #99, which this lantern used. Maybe it's not running as strong as it should, or at least then? It runs pretty dang great now, maybe I need to try again.

  • @scottf4277
    @scottf4277 Жыл бұрын

    What parts do you commonly clean in your ultrasonic cleaner?

  • @gasunderpressure9131

    @gasunderpressure9131

    Жыл бұрын

    Just about anything that fits! Burner tubes, fuel caps after burning out the old gasket, burner caps with clogged screens, air tubes, generators, gas tips, etc. It's pretty handy to have, and the small ones aren't too pricy. Also good for non-latern things too as you'll find out.

  • @pauldeary
    @pauldearyАй бұрын

    Can you leave a link to the guy that makes the generators please. Much appreciate

  • @gasunderpressure9131

    @gasunderpressure9131

    Ай бұрын

    You should be able to contact him via FB: facebook.com/johnny.turvaville